1. System Manual Part 1 System Overview 24 1 1 6 Housing And Module Frames The robust IP Video Door Station can be installed in both on wall and in wall systems it is weatherproof IP 65 and cannot be stolen The system consists of a housing and a frame The frame for mounting the modules is simply screwed on to the housing used On Wall Housing Fig Triple Housing A Wall mount 4x Mounting points for terminal board or IO module 3x 5 E z Mounting points o e 6 e for cable binders a 2 8x marked yellow 3 D O 9 B gt 2 Cable guide 6 2 gt 9 o a N 2 E N g amp 9 Mounting points 8 for module frames Z oli 8x marked green 8 5 Eg E 5 Mounting points for seal i MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Outdoor Station 131 mm 327 mm double housing 227 mm single housing 138 mm 333 mm double housing 233 mm single housing 143 mm 44 mm 76 mm MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 3 8 1 48 24 System Manual Part 1 System Overview In Wall And Cavity Housing Fig Triple Housing The blue housing is firmly connected to
2. System Manual Part 1 System Overview 24 11 4 Info Module T24 Info The standard info module provides the option to attach the house or building number and or name to the door station The module is equipped with permanent backlighting using energy saving and long lasting LED technology 99 mm _ 4 B 4 Info field can be labeled behind cover Security Vision Systems Sealing plug Seal MxBus terminal power supply for the LED MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Outdoor Station 31 148 Technical Specifications T24 Info Functions Information for visitors on nameplate name street number etc Interfaces MxBus User interfaces Backlit printable foil UV protected Protection class IP65 DIN EN 60529 Operating temperature 30 C to 50 C 22 F to 122 F DIN EN 50125 Power supply MxBus Power consumption typically 0 2 W Dimensions W x H 99 mm x 99 mm Technical Specifications Terminals Used On The Info Module Cable cross section fixed min 0 14 mm max 0 5 mm E Cable cross section min 0 2 mm max 0 5 mm flexible Cable cross section min 0 25 mm max 0 5 mm flexible with wire end sleeves without plastic sleeves Cable cross section min 24 max 20 AWG kcmil AWG according to UL CUL min 26 max 20 Note On Labeling
3. MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 MOBOTIX Glossary 24 Opening Contact On moveable building elements window door a magnetic contact Reed contact is attached to the fixed part and a magnet is attached to the moveable part When the door is closed the magnet is located in direct proximity to the contact and keeps it closed When the door is opened the magnet is removed and the contact opens PIR Sensor Passive infrared sensor for motion detection Pixel Picture Element One of the many tiny image dots that make up a digital image Each pixel determines through its color and intensity a tiny part of the overall image Perimeter Protection Perimeter protection outdoor protection serves to protect an object through measures in its surroundings or in the surrounding free space usually up to and including the site boundary line This includes mechanical building measures perimeter security electronic detection measures and or organizational staffing measures perimeter surveillance PoE Power over Ethernet Power over Ethernet enables power to be supplied to a network device using the same cable that is used for connection to the network This is particularly beneficial in the case of IP and remote surveillance in places where laying a power cable from the nearest outlet would be too costly or time consuming Product Liability U
4. Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 5 3 Mounting Instructions Solid Concrete Or Stone Wall MOBOTIX recommends using a deep in wall socket more space for cables Standard in wall sockets with a depth of 43 mm are not suitable for the T24 DoorMaster Deep in wall socket 68 mm 67 mm in depth Cavity Wall e g Plasterboard 7 mm to 35 mm Use the supplied 61 mm deep cavity socket for the T24 DoorMaster Cavity socket 6 68 mm 61 mm in depth MOBOTIX offers two orange cavity sockets of different depths 48 mm and 61 mm The 61 mm deep socket is designed for the T24 DoorMaster and the 48 mm deep socket is intended for the T24 Info2wire indoor unit Determining The Installation Position The T24 DoorMaster must always be installed indoors protected from weather and moisture If in doubt use the normal installation conditions of a standard socket with no cover as a guide The anti theft protection connection cables pre fitted to the frame of the outdoor station do not need to be extended if the T24 DoorMaster is mounted on the same wall behind the outdoor station next to the entrance door MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 100 Drill hole for cavity socket 6 68 mm Maximum MxBus cable length between T24 DoorMaste door station 50 m
5. Alarm notify cam remote control VideoMotion Multiple windows precision pixel based 22 10 140 F Weatherproof 30 to 60 C IP65 no heating necessary HD Super Panorama From wallto wall without any blind spots IEEE 802 3of PoE Network power even in winter HiRes Video Innovations Robust No moving parts The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its glass housing decentralized concept has made high resolution video systems cost efficient MxCC MxEOSy Licence free Video Management Softwore MOBOTIX AG D 67722 Langmeil Tel 49 6302 9816 103 Fax 49 6302 9816 190 sales mobotix com 2 05 2012 9 E z 5 5
6. T24 System Manual The HiRes Video Company MO BOTIX HiRes 3 Megapixel 2048 x 1536 Software zoom Skyline Format free Each image format freely definable Part 1 System Overview And Installation Installation and cabling for the installer 30 Frames s VGA 640 x 480 30 F s Mega Virtual PTZ Digital pan tilt zoom Part 2 Start Up And Configuration Software and network for the system administrator Backlight Safe using CMOS without mechanical iris Part 3 Operating Manual Modules and remote stations for the user Internal DVR Intemal via Flash external via Network Win Lin Mac Recording via Network on PC up to Terabyte Microphone amp specker Audio bi directional via IP variable framerates SIP Client with video IP Telephony Alarm notify cam remote control VideoMotion Multiple windows precision pixel based 22 10 140 F Weatherproof 30 to 60 C IP65 no heating necessary HD Super Panorama From wallto wall without any blind spots IEEE 802 3of PoE Network power even in winter HiRes Video Innovations Robust No moving parts The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its glass housing decentralized concept has made high resolution video systems cost efficient MxCC MxEOSy Licence free Video Management Softwore MOBOTIX AG D 67722 Langmeil
7. You will find some PDF templates which you can print out yourself on the MOBOTIX website www mobotix com MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com System Manual Part 1 System Overview 24 11 5 124 Info2wire Info Module With Indoor Unit T24 Info2wire Info Module The info module with Mx2wire technology combined with a second Mx2wire unit to be mounted inside the building offers users not only the standard info module functions but also the option to connect and supply power to the door station via two wire cabling instead of a network cable see Section 1 1 4 Advantage Simple and cost effective installation thanks to reuse of already existing two wire cabling 99 mm _ 4 A LED orange data Security Vision Systems LED green power supply E E o MOBOTIX 8 Info field can be labeled behind cover y View with housing cover removed Sealing plug Seal Ethernet PoE injector Two wire 48 V DC optional additional connection power supply To activate the LED illumination ofthe module you need to cautiously remove the small black jumper on the circuit board using tweezers or small pliers before mounting the module itself LED illumination LED illumination deactivated activated MOBOTIX AG Security Vision Systems Made in Germany www mobotix com
8. MOBOTIX provides two different types of housing for these installation methods The modules and the frame fitted to the housing are suitable for all installation options MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com System Manual Part 1 Installation 24 68 148 2 3 2 Inserting All The Cables On Wall Housing The housing has cable guides made of elastic rubber to ensure the cable entry points are waterproof Use only one cable guide for each cable Pierce the cable guide you require using a screwdriver or other similar tool and feed the cable into the housing If the cable is multi wire separate the individual wires once the cable is in the housing S e 1 H nt Pierce required guide holes e g Do not open the cable with rebel n diner s le r guides up too wide for 1 HOOO example if you are using a cutter as cables fed inside the housing must be tightly enclosed to ensure a tight seal Guide cable through hole one cable per inlet In Wall And Cavity Housing Remove the insert and use a screwdriver or similar tool to pierce through all the openings on the rear or on sides required for inserting cables As the housing is embedded in the brickwork this usually makes for a tight seal If in doubt or when using a cavity housing you should additionally seal the cable guides with silicone Pierce required guide
9. Silicon matt C Info module D 5 Position the protective cover at the bottom of the info module D and press the top of the cover until i Familie Schmidt it clicks in place Now you can click the info module den Gena back into the door station frame Stee Anna Schmid Info_Panel pdf available at www mobotix com Here are a few examples of doorbell labels that were created using the PDF file template To open the file requires Adobe Acrobat Reader free Familie Schmidt Klaus Schmidt Familie Mayer Peter Mayer Klaus Schmidt Peter Mayer 2e Susanne Schmidt 2e Simone Mayer Susanne Schmidt 20 Simone Mayer Anna Schmidt ved Nina Mayer dm WELCI ONECLLIILIL xXx N C Familie Schmidt Familie Mayer 1 Schmidt Mayer Anna Schmidt Peter Mayer 16 2 EL m gt U S Familie Familie Schmidt Mayer TIER om MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 6 Removing And Exchanging Modules If anti theft protection has been activated see Section 2 3 7 you will need to switch this off before you can remove and exchange the modules Hold at the same time until the blue LED flashes Switching off anti theft
10. Simply add your personal data to the template and print it onto a sheet of A4 paper Then simply cut out your doorbell label and insert it into the info module Before you do this you will need to remove the info module from the door station frame see Section 2 4 6 that follows To create a doorbell label that goes with a keypad please make sure to familiarize yourself beforehand with how to configure and operate the door station see Part 2 of the System Manual Proceed as follows 1 Make your personalized doorbell label To do this 1 customize the PDF template Info Panel pdf provided Pine on the MOBOTIX website www mobotix com Susanne Schmidt Anna Schmidt 4 6 2 Loosen the transparent protective cover on the info module by hand or using a screwdriver which you position on the side as shown in red and use as a lever 3 Tilt the protective cover downwards and remove the silicone mat and paper insert Security Vision Systems MOBOTIX MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 Modules 4 Place your completed doorbell label B behind the transparent protective cover A Insert the silicone mat C so that its smooth side is behind the label Familie Schmidt O rect order 2 6 Susanne Schmidt B Anna Schmidt H 4e Protective cover A Doorbell label B
11. lens meaning that they are only able to capture visitors standing directly in front of the lens However much of the time the door station is not mounted in the immediate vicinity of the door so the camera is at an angle to the visitor see image Even in this case thanks to its 180 image angle the T24 delivers perfect images Right Orig nal MOBOTIX T24 image Direct Views Up And Down Original MOBOTIX T24 mage enlarged mage section And the hemispheric camera can do much much more it can record the area on the floor in front of the door for example even the often overlooked area underneath the door station And the T24 does all of this using only its software without the need for moving parts or motors This camera is silent discreet and unobtrusive Also this quick look down is incredibly practical when checking for example whether the daily paper is already in front of the door Of course it is also possible to look upwards under the ceiling as well MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com T24 System Manual Part 1 Overview Of Modules Product Overview T24 Modules In addition to the hemispheric HiRes camera the latest MOBOTIX development also includes a multifunctional keypad module with transponder technology for keyless access and control of message functions T24 KeypadRFID A particular advantage of the T24 is the minimal amount of
12. nominal resistance 10 ohm no support for closed circuit current function can be connected directly to the T24 DoorMaster and powered by its integrated battery pack It is not necessary to connect an additional power supply unit By integrating an additional power supply unit door openers with up 24 V AC DC max or a self locking door lock e g Mediator can be connected MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com 44 148 24 System Manual Part 1 System Overview 1 3 Remote Stations 13 1 Grandstream IP Video Telephone GXV3140 MOBOTIX recommends the GXV3140 from Grandstream as a remote video station for the T24 door station This modern IP video telephone is based on the world standard in telephony VoIP SIP with H 264 and provides a large color LCD display with excellent image quality The device is conveniently operated via a MOBOTIX user menu GRANDSTREAM Display Bas c T24 functions can also be controlled using the phone keys SD card slot USB Audio output Video output Connector for telephone receiver connection 1 Power supply Network s connection 2 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 45 148 See also www grandstream com Remote Stations Extensive Multimedia Facilities The GXV3140 from Grandstream includes impor
13. sales mobotix com purposes wit first 15 minu A PoE switch an external connectio 600 mA can Outdoor Station 3 3 148 Technical Specifications T24 Info2wire Info Module Data transfer rate Up to 50 Mbps net depending on distance Ethernet PoE injector Mx2wire indoor unit 48 57 V DC 600 mA Interfaces optional additional supply Certificates EMV EN55022 EN55024 EN61000 6 1 FCC part15B AS NZS3548 Protection class IP65 DIN EN 60529 Operating temperature 30 C to 50 C 22 F to 122 F DIN EN 50125 Connecting wire thickness Cable cross section 0 14 to 2 5 mm diameter 0 4 to 1 6 mm Dimensions W x 99 mm x 99 mm Note On Labeling You will find some PDF templates which you can print out yourself on the MOBOTIX website www mobotix com Standard Two Wire Cabling Already Laid In Buildings Analog Telephone Line Or Bell Wire e Cable type JY A2Y and YR telephone and low voltage cable e Very good availability in buildings Core diameter 0 6 to 0 8 mm e Range at 50 Mbps 100 m 0 6 mm 200 m 0 8 mm Power Line Should No Longer Be Live e Cable type NY installation cable e Widespread availability of cables e Cables must be disconnected from the power supply e Wire cross section max 1 5 mm e Range at 40 Mbps 300 m Safety Warning Use this product in compliance with the applicable legal regulations Electrical sys
14. 124 IP Video Door Station from MOBOTIX offers an innovative powerful solution that is easy to install and takes a different approach to the solutions available on the market up to now The T24 is based on the international video telephony standard VoIP SIP with 4 264 and G 711 All of the modules offered for outdoor use are weatherproof maintenance free and can be used in temperatures ranging from 30 C to 50 C 22 F to 122 F Here are the most important system advantages at a glance Allround View With No Blind Spots With 3 1 megapixels and an internal memory this hemispheric door camera records the entire entrance area No blind spots from wall to wall and from floor to ceiling Two Way Video Communication Worldwide When the doorbell rings a connection is established with an IP video phone or a standard computer via the network For two way video communication and for opening the door Recording With Sound The camera in the door station can record events automatically For example when someone rings the doorbell or if something moves in front of the door Keyless Access Who has access and who doesn t The door opener can be controlled tamper proof using the T24 KeypadRFID with a PIN code or an RFID transponder Integrated Message Function Digital voice messages for residents can be left directly at the door station and played back after authentication Very Simple Installation The door station is connected to the network via an
15. Deactivating The Anti Theft Protection Lock Turn the red rotary button so that the arrow points to the opened lock symbol MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 Installing The T24 Modules Beware of short circuits When you install the modules the MxBus cable should not be live which means that the network cable should still be disconnected from the PoE switch 2 4 1 Installing The Camera Module T24 CamCore Standard Network Connection The Ethernet terminal board is used to connect the door station for the T24 version without Mx2wire technology It connects the short pre installed camera patch cable with the eight split out wires of the network installation cable for installation see Section 2 2 5 1 Ensure that the seal is fitted to the camera module Seal 2 Connect the supplied MxBus cable to the push terminal on the rear wall of the camera Remove approximately 5 mm of insulation from the cable ends and pus into the terminal e Red wire to terminal e Blue wire to terminal To connect the MxBus cable of the T24 DoorMaster the two free MxBus terminals of the camera module can be used as an alternative to the MxBus terminals on the keypad or info module see Section 2 5 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com
16. Ethernet cable or via two wire cabling thanks to Mx2wire technology MOBOTIX integrates hemispheric technology into existing p Siedle Vario Systems for added security thanks to superior overview images and event controlled recording of video and sound MOBOTIX TIX AG gt Security Vision Systems Made in Germany www mobotix com sales mobotix com 10 148 The 24 modules are available ndividually or in a set 11 148 What Advantages Does MOBOTIX Offer Over Other Video Door Stations Thanks to its HiRes image quality decentralized technology and a wide range of features MOBOTIX offers not only an outstanding door camera but also a professional security camera in a single device MOBOTIX Hemispheric Video Technology was successfully introduced to the network video market in 2008 This technology is an important component of the MOBOTIX video door stations which provide perfect high resolution overview images thanks to fisheye lens with a 180 image angle This allows the camera to cover the entire entrance area from wall to wall and from floor to ceiling without any blind spots and without ever needing to mechanically pan or tilt Fisheye view But the camera with its unrivaled image quality and panoramic view is much more than just a modern door spy The camera has an integrated high speed processor that provides a range of functions similar to those available in MOB
17. If the intended use of the device is at an unprotected outdoor location you should only install white or silver colored modules and frames Do Not Remove Lens Cover The camera module of the door station may not be operated without the installed transparent lens cover The camera is no longer weather proof when operated without the lens cover the removal of the cover exposes the metal ring around the lens which is especially prone to overheat in high temperatures Therefore anyone who touches the ring with their bare hand is at risk of being burned MOBOTIX AG Security Vision Systems Made in Germany www mobotix com info mobotix com 7 148 Security Vision Sysiems MOBOTIX AG Security Vision Systems Made in Germany www mobotix com info mobotix com System Manual Part 1 Foreword 24 FOREWORD Dear MOBOTIX customer Congratulations on your decision to purchase an exceptionally versatile and innovative IP Video Door Station made in Germany The T24 system contains a hemispheric door camera with a 3 1 megapixel color sensor T24 CamCore and captures the entire room 180 from wall to wall and from floor to ceiling without any blind spots Chapter 1 of the System Manual Part 1 contains all product details and the technical information of the system Chapter 2 deals with the installation of the T24 with a direct network connection or the optional connection via two
18. cable binders 8x marked yellow un 8 mm MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Mounting The Frame And Housing The T24 housing on wall in wall provides sufficient space for cable reserves see the blue dashed line in the figure The red areas are off limits areas No cables should be placed in this area risk of damage to cables when module is mounted Cable guide dotted blue Off limits for cable guide MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 5 Mounting The Terminal Board And Fitting The Network Cable Mounting The Ethernet Terminal Board Screw the board into the housing flattened side is at the bottom The terminal board must be placed behind the camera module This step is not necessary for the T24 version with Mx2wire technology two wire cable replaces Ethernet cable as an Ethernet terminal board is not required Attachment of board for vertical and horizontal installation 2 9 2 e E DS 9 e 9 e 0 3S SSS SSS Stripping And Fitting The Network Cable The Ethernet terminal board provides a link from the network installation cable to the special patch cable of the camera module mounted directly above Connect the eight wires of t
19. cable with 0 8 mm core diameter even in the 10 Gbit Ethernet case of smaller installations to make future expansion more convenient As a rule however when maximum cable lengths are kept low YSTY telephone cable with only a 0 6 mm core diameter may also be used When laying the cable ensure that sufficient length remains in reserve on the door station end for later extensions or for swapping modules lay a cable loop All two wire cables should be fed in through a in wall socket on the inside of the door with sufficient space for cable reserves Both the network cable and other cables must be stripped at the ends MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 9 4 IO Module And Terminal Connectors MOBOTIX IO Module T24 OPT IO The central connection unit for the door station is available from MOBOTIX as an accessory and is required in the Siedle Vario system e Bridge circuit from Ethernet installation cable to camera patch cable e Connection to Siedle transformer contact b and c e Connection to Siedle modules for example call buttons Connection of a door opener e Connection to the door and door lock switches Connection for external light Ethernet connector with PoE supply 1 x Cable sheath contact Camera connector MOBOTIX patch cable Terminal connector for Siedle modules power do
20. cover plate back on 6 First of all insert the right side of the module into the frame Then press firmly on the left side until the module audibly clicks into place de gt S6 omy TD 9e Gow Control click If you do not hear a click sound this means that the module is not properly locked into place In this case repeat the last steps making sure that no cable or foreign object in the housing is preventing the module from properly clicking into place MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 4 Installing The Info Module T24 Info2wire The info module with integrated Mx2wire technology is used to connect the door station to the network via a two wire cable such as a bell wire and has an info field with permanent LED backlighting 1 Ensure that the seal is fitted to the info module Seal 2 Loosen the rear cover plate using a small screwdriver or similar tool and remove it You now have a clear view of the connectors located directly on the info module board 3 Remove approximately 5 mm of insulation from each of the cables to be connected and feed each cable through one of the wire apertures the housing piercing the rubber membrane with the cable 4 Connect the two wire cable which leads to the separate T24 Info2wire unit in the building to the boa
21. installed correctly using matching MOBOTIX housings and frames 2 3 1 Determining The Installation Position Before installing the door station you need to decide exactly where fo install it In addition to being mounted vertically most popular installation option the door station can also be mounted horizontally MOBOTIX Vertical installation Horizontal installation In a vertical layout the camera module T24 CamCore is normally positioned right at the top The keypad is located directly underneath followed by the info module Position the housing directly above the cables that come out of the wall network two wire cables None of the connection cables should remain visible as this would make them vulnerable to manipulation MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Mounting The Frame And Housing 67 148 To ensure ease of use the system should be installed to accommodate people of different heights The height from the ground to the upper edge of the frame should be at least 1 60 m 1 LA lisom Unlike conventional door cameras the T24 CamCore with its 180 image angle is also able to record visitors when they are NOT standing directly in front of the lens This means that the door station can be mounted quite flexibly which is particularly useful with wide doors The installation can be on wall in wall or using a cavity socket
22. is running is often also known as a server In practice the server computer can run a very large number of server and client programs The program that provides the requested HTML pages or files for the client browser is known as a web server Signal Inputs and Outputs Using the digital inputs and outputs on the T24 any device that can switch between an open and closed circuit can be connected Signatures for Video Images Digital video images can be transferred as well as jointly edited and deleted via data networks In order to prevent unwanted manipulation and to ensure the validity of digital video sequences in the case of investigations it is necessary to faultlessly identify the time of recording the origin of the images camera ID and the authenticity of the images no changes after recording This is only possible if the images are labeled using MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 MOBOTIX Glossary 24 cryptographic methods In the case of digital video cameras with integrated analysis it is possible to integrate a unique camera ID and the precise time of day and to encrypt this data so that any change to or manipulation of the video sequence can be traced during later analysis SIP Session Initiation Protocol Network protocol for setting up controlling and terminating a communication connection via computer network SIP is fr
23. lt q Note slot for key MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 8 Mechanical Anti Theft Protection Lock In the default configuration of the door station anti theft protection is not activated in the frame This allows modules that have already been integrated to be removed again during the installation just using the special key that has been supplied Insert the key into the opening provided and apply light pressure The red retaining collars on the left or lower side of the frame depending on whether the frame is mounted vertically or horizontally loosen and release the modules To activate the mechanical anti theft protection lock the module above the red rotary button triple frame center module double frame upper left module must be released from the frame Important After the installation check the wiring see Section 2 8 1 and only then activate the anti theft protection lock Retaining tabs MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com 78 Special key Mounting The Frame And Housing Activating The Anti Theft Protection Lock Use a screwdriver to turn the red rotary button inside the frame 90 degrees clockwise When anti theft protection is activated the arrow points to the closed lock symbol
24. mobotix com sales mobotix com System Manual Part 1 Installation 24 Floor Call The integrated floor call function presents a convenient option to assign directly at the apartment door each of the bell buttons at the building door to an additional bell button floor call button To connect the floor call buttons first connect eLi c to c connect one contact of the floor call button with ERT in order to reloop ERT from unit to unit and the other contact with the terminal belonging to the apartment 7 1 7 2 7 3 or 7 4 00 000 65 0 the IO module relay between eLi c and eLi is to be isolated and simultaneously used for the floor call function an external accessories diode for example Siedle ZD will be needed c is connected to the anode of the diode while the cathode 061 10 is connected to the floor call button diode conduction direction from c to the floor call buttons the other contact of the floor call button is connected to the terminal associated with the apartment 7 1 7 2 7 3 or 7 4 Door Opener Connect the electromagnetic door switch opener to IO module Do connect second connector to c 1 2 M 2 gt g 0 L LJ bi 2 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Module Bell button 4 Bell button 3 Bell button 2 Bell button 1 Bell bu
25. mounting inside the building offers users not only the standard info module functions but also the option to connect and supply power to the door station via existing two wire cabling instead of a network cable MX 2wire Infol EXT Frame Single frame 131 x 143 x 18 mm W x Hx D Integrated electromagnetic anti theft protection Includes special key for module unlocking housing seal and installation material Double frame 131 x 233 x 18 mm W H Integrated electromagnetic anti theft protection Includes special key for module unlocking housing seal and installation material MX OPT Frame 2 EXT 1 Triple frame 131 x 333 x 18 mm W H x DJ Integrated electromagnetic anti theft protection Includes special key for module unlocking housing seal and installation material x En 5 5 gt lt AG Security Vision Systems Made in Germany www mobotix com sales mobotix com The ndoor unit i always part T24 Info2 info module On wall housing Single on wall housing 126 x 138 x 31 mm W x H x D Metal reinforced housing MX OPT Box 1 EXT ON Double on wall housing 126 x 227 x 31 mm W x H x D Metal reinforced housing z E gt lt q x e en a S Triple on wall housing 126 x 327 x 31 mm W H D Metal reinforced housing MX OPT
26. note that you will need the stainless steel screw in the front panel again later Safety Warning Use this product in compliance with the applicable legal regulations Electrical systems and equipment may only be set up changed and maintained by a qualified electrician or under the management and supervision of a qualified electrician in accordance with electrotechnical regulations MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 4 Insertthe housing and circuit board into the socket The two cable clamps on the rear of the housing are located at the top For a cavity socket make sure you only use the stainless steel screws provided Using different larger screws could damage the circuit board 5 Attach the frame Place the selected frame concave convex or flat onto the board and press down gently until it automatically snaps into place MOBOTIX is printed on the bottom of the frame 6 Insert the panel Hook the front panel onto the frame as shown in the figure and then press it down 7 Screw the panel on tightly Secure the front panel using the panel s stainless steel screw MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The Indoor Unit T24 Info2wire 1 1 1 148 2 6 4 Installation With Surface Mounted Socket 4 20 mm 1 Prepare t
27. optimized for use with mobile devices and touch panels Incorrect settings can be easily reversed using the automatic backup feature Security MxEasy provides you with four different access levels Guest User Owner Administrator allowing people with different levels of authorization to access the camera images MxEasy can be installed on several computers at the same time Optional HTTPS encryption using certificates generated by the camera or created by the administrator helps you to prevent unauthorized users from accessing MxEasy MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 1 4 Accessories 1 4 1 NPA PoE Set The MOBOTIX Network Power Adapter Set NPA PoE set is a high quality robust ultra compact and above all multifunctional PoE injector with three connectors network camerd PoE device PC and a universal power supply unit with adapter plugs The Network Power Adapter Set supplies the T24 door station and all other PoE devices with power in accordance with the IEEE 802 3af standard It is therefore possible to secure the power supply for distances up to 100 m 300 ft using the network cable As a result the T24 IP Video Door Station can be supplied with PoE power via the adapter and connected directly to a remote station integrated crossover function PoE injector PC VoIP video telephone or POWER LA
28. protection on the T24 DoorMaster Press both buttons on the T24 DoorMaster at the same time for ten seconds to deactivate the anti theft protection for 90 seconds blue LED blinks After this the protection will be automatically reactivated Switching off anti theft protection when there is no T24 DoorMaster Connect the two cables of the anti theft protection to the 12 V power supply of the electric door opener via a switch Anti theft protection is deactivated for as long as the Indoors Power supply 12 V The anti theft protection must be disconnected from the voltage again switch off after no more than five minutes in order to avoid an overload voltage is applied switch on Outdoors MOBOTIX MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 1 sn Gp ALIA d y U Installing The T24 Modules 3 Removing the modules Insert the special MOBOTIX key provided into the split opening on the module frame bottom left or bottom right depending on how it has been mounted and release the modules from the frame by pushing the key in All the modules in the frame move slightly forward and can be removed Click listen for click sound any modules that you do not wish to remove back into place Insert and press Make sure that the anti theft protection has been deactivated before you insert the key otherwise you ri
29. the subsurface or brick work It can also be used to ensure easy installation in cavities Drill opening position housing and screw tightly in place the retaining wings which automatically swing out secure the housing while the plastic bars at the edge of the housing prevent it from sliding into the cavity 52mm 117 mm The nsert prevents the in wall hous ng from gett ng dirty or be ng deformed dur ng installation Plastic bars 6x Mounting points for module frames 4x marked green Mounting points for terminal board or IO module 3x Mounting points for cable binders 8x marked yellow The required integration open ng has the follow ng dimensions width x height Cable guide 14x Do not use the four red holding fixtures for module frames Single hous ng 117 x 129 mm Double hous ng 117 x 218 mm Triple housing 117 x 318 mm 318 mm double housing 218 mm single housing 129 mm Mounting points for seal Retaining wings for cavity installation 4x MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 39 148 Permissible wall thickness for cavity installation min 7 mm max 27 mm 7 27 mm Outdoor Station 131 mm 50 mm 318 mm double housing 218 mm single housing 129 mm 333 mm double housing 233 mm single housing 143 mm 69 mm 97 mm MOBOTIX AG Secu
30. 101 148 Installing The T24 DoorMaster Preparing The In Wall Socket Solid Wall A in wall socket must usually be fitted first Make sure that the socket you use is as flush with the wall as possible to ensure proper installation Also make sure that the socket and T24 DoorMaster are aligned correctly After connecting the cables there are two ways to attach the door opener board to the in wall socket Secure the housing and board directly to the socket by fastening two small screws in the a and b positions see fig However this requires that the socket is properly aligned in the wall Thanks to the elongated shape of the screw holes it is possible to make small adjustments to the left and to the right when tightening the screws fa ib Use four or two Torx screws screw anchors diagonally opposite one another to tightly screw the housing and board to the wall We recommend using this procedure if the installed in wall socket is not properly aligned or is not flush with the wall or if the T24 DoorMaster could easily be pulled out together with the in wall socket 1 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 Preparing The Cavity Socket Cavity Wall The T24 DoorMaster can be mounted to a cavity wall for example plasterboard up to a thickness of 35 mm using either the supplied cavity socket or an existing socke
31. 48 The figure above the connection sections represents the number of cable w res Black YSTY 0 8 recommended or 0 6 mm Orange Ethernet Cat 5 or higher The external 12 V power supply including a cable from the switch box is required here for an optional Mediator www mobotix com sales mobotix com MOBOTIX AG Security Vision Systems Made in Germany ctly 810 D198 V INO WOOD _ WOOD 6 NI pun Ajddns A ZL p 6 NI LNI JuDi puJejxe Jo uoipeuuo L NI XW XW XW nected hrough 5 6 g ng uoy3 401d 4eui Huy q V 7 HA3XW 1 0 lt c c 0 6 INO L INO 1 6 NI 005 01 dn pesn y uo spuedep aster is g pasamod jas Jeuedo 100q UDIIMS J00q 1000 4 u iod Joys p YIMS 309 0 GO er iagrams D iring Connection And Wi Overview System Manual Part 1 Installation 24 2 1 4 Recommendation
32. 7 1 7 3 PES 1st doorbell button L 73 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 7 2 Using The Keypad Signal Outputs the T24 door station is used with the T24 DoorMaster and a standard door opener all the keypad connectors apart from the MxBus connector remain unused see Section 2 5 2 Version 1 _ 4 Example Connecting A Lamp That Is Supplied With 230 Connect power relay for lamp e First wire to COM terminal e Second wire to OUT A terminal e Third wire to lamp e Fourth wire to 230 V Connect external power supply for relay e g 12 V AC e First wire to OUT B terminal e Second wire to COM terminal Connect lamp e First wire to power relay e Second wire to 230 V Relay Lamp MX MX 4 MX IN 1 IN 1 IN 24 Power supply 230 V e g 12 V AC MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Connecting External Devices To The Door Station Example Connecting Up To Two Bell Buttons Connect first bell button e First wire to terminal e Second wire to INT terminal Connect second bell button e First wire to IN2 terminal e Second wire to IN2 terminal The voltage required by the bell buttons low voltage is supplied by the keypad No additional p
33. 80 148 Secunty Visor MOBOTIX Do not swap the and w res When using a different colored cable make sure the correct polarity is routed Installing The T24 Modules 3 Guide the MxBus cable to be shortened accordingly into the housing and under the frame so that it can be easily connected to the keypad later on Insert the pre installed camera module patch cable into the RJ45 port on the terminal board Patch cable MxBus cable for the keypad 4 First ofall insert the right side of the module into the frame and then press firmly on the left side until the module audibly clicks into place Control click If you do not hear a click this means that the module is not properly locked into place In this case repeat the last steps making sure that no cable or foreign object in the housing is preventing the module from properly clicking into place MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 8 2 1 48 24 System Manual Part 1 Installation Network Connection Via Mx2wire Technology An Ethernet terminal board is not required for the T24 door station with Mx2wire technology Instead the camera module is connected to the T24 Info2wire info module via MOBOTIX patch cable 1 Ensure that the seal is fitted to the camera module Seal 2 Remove the pre installed camera module patch cable and instead inse
34. Abbreviation for Joint Photographic Experts Group responsible for the development of the JPEG standard method for image compression JPEG is the most common lossy image format for photos on the Internet Loss in image quality is barely noticeable at compression rates ranging from 60 to 99 LAN Local Area Network A LAN consists of a series of computers and associated devices that use the same communication resources in a restricted geographical area LED Abbreviation for Light Emitting Diode an electronic semiconductor component built into MOBOTIX cameras and add on modules that emits light when a current flows through the component in the correct direction Lux The unit for measuring the quantity of light MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 142 148 143 148 Mbps megabits per second Unit for measuring the bit rate i e the speed at which bits are transferred to a particular location Network speed is usually stated in Mbps LANs are often operated at 10 Mbps or 100 Mbps See also bit rate Mediator Lock A self locking door lock with an electrical door opener Can also be retrofitted on existing doors People can exit through the door at any time despite the fact that the door is constantly locked Exiting is possible in the case of danger during normal operations and without a key safeguarding of escape routes Megapixel Images that have more than 1 m
35. Advantage flexible voltage connection option and direct connection of a router switch for connecting remote stations for example Fritz Box WLAN Extending The Range A further advantage of Mx2wire is that it allows the range of a connection to be extended considerably using a two wire cable up to 500 m long a T24 connection using a network cable is limited to 100 For detailed technical information on the T24 version with Mx2wire technology see Section 1 1 5 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 6 2 Mounting Instructions Mounting Options In addition to an on wall installation using the supplied surface mounted socket you can also choose to install the T24 Info2wire indoor unit using a standard in wall socket or a cavity socket for wood or plasterboard for example Included in the delivery is a cavity socket of very high quality with soft rubber gaskets on the rear that need to be punctured by the two wires that feed in The tight seal provided here is far superior to that offered by standard cavity sockets without this feature 2 Surface mounted socket In wall socket Cavity socket Please follow the installation instructions in Section 2 5 3 They also apply to the T24 Info2wire indoor unit Preparing And Testing The Two Wire Cable In general Mx2wire is used with existing cables bell wire Whe
36. Box 3 EXT ON In wall housing incl plasterwork protection Single in wall housing 123 x 138 x 52 mm W x H The in wall housing is securely connected with the subsurface or brick work It can also be used to ensure easy installation in cavities MX OPT Box 1 EXT IN Double in wall housing 123 x 228 x 52 mm W H x D The in wall housing is securely connected with the subsurface or brick work It can also be used to ensure easy installation in cavities MX OPT Box 2 EXT IN Triple in wall housing 123 328 x 52 mm W x H x D The in wall housing is securely connected with the subsurface or brick work It can also be used to ensure easy installation in cavities MX OPT Box 3 EXT IN MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Individual Components Indoors 24 T24 Components Indoors T24 DoorMaster With Backup Power Supply The T24 may be coupled with the MOBOTIX T24 DoorMaster with internal access code memory and battery for back up power supply making it impossible to open the door by forcibly removing the system and bypassing the connecting cable MxX Door INT T24 Info2wire Indoor Unit An Mx2wire set always consists of two devices that communicate with one another For this reason the T24 Info2wire info module in the door station also requires a corresponding un
37. Devices And Siedle Vario In addition to general technical specifications for the signal inputs and outputs the table also shows the precise layout of the 16 wire terminal connector when the external devices are modules from the Siedle Vario series see Section 2 9 3 x signal outputs General Funcion Siedle Vario Function Comment MX MxBus Direct connection to camera MxBus module MX MxBus tb b Gnd Ground Reference potential 2 ERT HW Signal from eLi c half wave rectified Floor call when c fits eLi c N z gt Relay switches b door opener ii 5 still connected to 2 d gt 5 Relay switches b iLi S Internal lights of Siedle modules modules each Z 5 still connected to c gt lt gt t eli c 5 gt Control for external light 238 e g over the entrance door Isolated relay NO type eli 5 5 5 Bpc Door lock switch Bolt Position Contact Contact switches c Dpc Door contact Door Position Contact Contact switches c Auth S2 Transponder Fingerprint Module switches c gt N gt PIR g u PIR module motion sensor Module switches c gt 4 gt 7 4 a Bell button 4 SDE 7 3 9 Bell button 3 Bell switches 6 full wave c 5 5 floor call switches ERT 225 half wave 7 2 Bell button 2 6 5 gt gt gt 71 Bell button 1 MOBOTIX AG Security Vision Systems Made in Germ
38. For Cabling Depending on the model the door station and its remote stations require one of the following cabling configurations Please take note of our cabling recommendations and the maximum cable lengths Both the network cable and other cables must be stripped at the door station ends Network cable from the Ethernet terminal board behind the camera module to the switch injector Recommendation Category 5 Cat 5 Ethernet installation cable or higher Cat 7 cable is designed for 10 Gbit Ethernet max future compatibility Max cable length 100 m Two wires from the door station to the T24 DoorMaster for the MxBus connector Recommendation YSTY telephone solid wire core diameter 0 6 to 0 8 mm Max cable length 50 m Cables from the T24 DoorMaster to the electric door opener the door contact and the door lock switch Recommendation YSTY telephone solid wire core diameter 0 6 to 0 8 mm Max cable length depending on the manufacturer max 50 m Two wires from the T24 DoorMaster to an additional power supply for example 12 V for Mediator operation Recommendation YSTY telephone solid wire core diameter 0 6 to 0 8 mm Max cable length depending on the manufacturer Two wires from the keypad to the 230 V light relay if present Recommendation YSTY telephone solid wire core diameter 0 6 to 0 8 mm Max cable length depending on the manufacturer Two wire cable from th
39. Germany www mobotix com sales mobotix com 18 148 The ndoor unit is always part of the T24 Info2wire info module Free download at www mobotix com The Custom Made IP Video Door Station 24 The 24 product line is a modular system that can be adapted to any customer needs This highly robust and weatherproof outdoor station IP65 suitable for 30 C to 50 C 22 F to 122 F is available in four attractive colors white silver dark gray black and amber T24 CamCore T24M Sec D11 PW MOBOTIX white PW silver SV dark gray DG black BL amber AM You will find the T24 online configurator tool on the MOBOTIX website which you can use to plan your individual T24 door station You can choose the individual components step by step so that no individual component is forgotten Accessories required for your selected components are automatically added by the configuration tool After you have finished the configuration the system creates a preview image of the system as well as a parts list which you can hand to your electronics specialist for an installation quote The web configurator can be found on the MOBOTIX website under the main menu item Products gt T24 configurator obotix com gt lt 4 rator T24 A Future Oriented System With the T24 MOBOTIX offers a new product range for the home automation market
40. In principle there is no need for a computer to handle configuration or operation when there is a simple application scenario one door station only IP video telephone as remote station pv Sf est 5588 1 n END 2 by IM ANY allows you to quickly and efficiently implement and control a video security system of 1 to 16 MOBOTIX cameras making it the perfect choice for all small and mid sized surveillance systems and the T24 IP Video Door Station The program automatically detects all installed cameras door stations even in non administered networks and carries out the initial configuration You are not required to have an in depth knowledge of network technology MxEasy enables the user to conveniently control the most important functions of the connected door station Virtual zooming panning and tilting in the live image is just as easy as using the live two way video communication with the visitor opening the door or activating recording The video data recorded by the cameras can then be viewed and exported in different formats such as H 264 at a later time MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com MxEasy free from www mo Remote Stations Easy Operation MxEasy is easy to understand and simple to use Descriptions for each graphical button tooltips are displayed automatically The user interface was also
41. M MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 21 148 Security Vision Systems OBOTIX MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Image 24 SYSTEM OVERVIEW T24 IP VIDEO DOOR STATION What does a typical system look like and what components are included This section describes the setup for a complete system with a video door station including a T24 DoorMaster T24 KeypadRFID and T24 Info2wire info module with Mx2wire technology to connect the door station using existing two wire cabling In newer buildings it is preferable to lay an Ethernet cable directly to the door Hemispheric camera with LEDs Two way video communication e Lip synchronous sound e Event controlled recording e Outdoor light and doorbell button Keypad integrated e Open lock door e Keyless access RFID and PIN Operate voice mailbox Info module backlit e With Mx2wire technology optional Data transfer and power supply via two wire connection MxBus encrypted Two wire cabling Data and power Cat cable Data and power OR MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Standard PC remote station e Free MOBOTIX MxEasy software e 124 configuration and operation gt Allfunctions including
42. N or POWER J MOd NV1 PC Power Integrated and patented crossover function T24 door station camera module This device is especially practical because the supplied power supply unit can be used around the world by changing the adapters as required in just two simple steps The E U version of the NPA PoE Set is supplied as standard with a European adapter while the INT version includes four adapters EU USA UK AUS Another product benefit is the option to connect to power sources from 12 V to 42 V that are independent of the network which is ideal for solar and battery operation of the door station e g in a holiday home gt 5 lt 5 x 5 E M 5 s MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 48 148 MX NPA PoE Set EN and MX NPA PoE Set INT incl adapter for EU US UK and AUS E 7 148 Accessories 1 4 2 T24 OPT IO Extended Terminal Boards In addition to the ethernet terminal board T24 OPT ETH MOBOTIX offers an IO module T24 OPT IO with extended connection options for the door station e g doorbell buttons light garage door opener etc The board provides 8 switch inputs and 3 switch outputs The network cable and the camera module T24 CamCore are connected in the same manner as the Ethernet terminal board Ethernet connector with PoE supply Cable sheath Camera connector contact RJ45 Extended co
43. OTIX security cameras used in banks and airports Thanks to the integrated Video Motion Detection when the camera registers movement in ihe image or detects suspicious noises it automatically starts recording smooth video with sound while simultaneously sending an e mail or SMS to the residents of the building or to a security company In addition a message may be left for the residents at the door station it works just like a telephone answering machine with the addition of video and audio recording by the camera module Additionally an audio message for visitors can be played back automatically when the doorbell button is pushed The camera captures the entire hemispherical area in front of the camera lens and displays it n user fr endly format as a corrected mage or image section or as an HD Super 180 panorama HD Super 180 AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 2 24 System Manual Part 1 Allround View With No Blind Spots Hemispheric HiRes Camera Thanks to the fisheye lens with its 180 image angle the camera records the entire entrance area without having to be mechanically panned or tilted without any blind spots from wall to wall floor to ceiling It s impossible to slip by this camera On the monitor located at the remote station the operator can change the current image section in seconds from a close u
44. T24 Info2wire info module which connected to the camera module via a patch cable becomes a PoE injector for the entire outdoor station and the T24 DoorMaster Network Connection And Power Supply Data And Power The T24 Info2wire indoor unit has an 145 port and is connected by patch cable to a switch or router and thus also to the local network and the remote stations In order for Mx2wire to power the T24 a voltage source is required There are two ways to achieve this 1 Power supply from a PoE switch Class 4 IEEE 802 3at max 30 W Connection via patch cable on the T24 Info2wire indoor unit With T24 Info2wire info module T24 Info2wire indoor unit Two wire cable Ss Data and power PoE switch IEEE 802 3at Advantage The PoE switch directly connects the T24 remote stations as well and depending on the number of available ports it can also power further PoE devices door stations IP cameras MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 106 Installing The Indoor Unit T24 Info2wire 2 Power supply from an external 48 V DC power supply unit Connection via two contact terminals either on the T24 Info2wire info module or on the indoor unit With T24 Info2wire info module m T24 Info2wire Switch e g indoor unit Fritz Box a Two wire cable Data and power Power supply 48 57 6
45. Tel 49 6302 9816 103 Fax 49 6302 9816 190 sales mobotix com 2 05 2012 9 E z 5 5 System Manual Part 1 Contents 24 T24 CamCore camera module e Allround view with no blind spots e Internal memory e Speaker e Microphone T24 KeypadRFID access module e Keyless access RFID and PIN e Operate voice mailbox e Contact remote stations Incl RFID transponder cards T24 Info T24 Info2wire info module e With integrated Mx2wire unit optional e Data and power PoE via two wire connection e Instead of connection via network cable e For two wire cables up to 500 m T24 DoorMaster indoors Opens door doorbell on off e Status LEDs for door and messages Backup power supply with battery e Connects to door opener and sensors MOBOTIX AG Security Vision Systems Made in Germany www mobotix com e info mobotix com SYSTEM MANUAL PART 1 SYSTEM OVERVIEW AND INSTALLATION This T24 System Manual Part 1 system overview and installation is complemented by 4 System Manual Part 2 start up and configuration If you no longer have a manual at your disposal you can download a PDF file from the MOBOTIX website www mobotix com gt Support Manuals 10 12 14 16 18 20 22 24 24 24 26 28 30 32 36 42 44 44 46 48 48 49 50 51 51 51 Foreword Hemispheric IP Video Door Statio
46. V power supply unit LED green network connection power supply Status display LED orange data transfer via AB conductor is active door station connected Operating conditions 30 C to 50 C 22 F to 122 F Connecting wire thickness Cable cross section 0 14 to 2 5 mm diameter 0 4 to 1 6 mm 80 mm 80 mm x 38 mm in wall version Dimensions W x H x D 80 mm x 80 mm 45 mm on wall version Max Cable Lengths Of Usable Cable Types As Two Wire Cable Of A T24 Door Station Cable type Cable thickness Max cable length mene d 0 6 mm inner core 100 m 50 Mbps coaxial cable Telephone line a 96mm 100 m 50 Mbps bell wire 0 8 mm 200 m 50 Mbps Installation cable 1 5 mm 300 40 Mbps Network installation cable Cat7 500 m 45 Mbps The Mx2wire set consisting of two units info module and indoor unit contains all the components required to establish an Ethernet connection via a two wire cable nfo2wire info ule with indoor unit Please note that the two Mx2wire units are matching pairs and preconfigured at the factory The use of a different Mx2wire unit that was not supplied in the original packaging is therefore technically not possible In case of a defect both units must always be exchanged for a new Mx2wire pair that has been configured by MOBOTIX MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com
47. a 5 SB gt 5 1 gt REUS ox X T es 5 VO o E E e x o t dz SF xoc lt 2 2 8855 Ea O O __ Ajddns samod A Z pub 249 4uDi JO MX 8 12 MX 4 MX D MxETH MX MX 8 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com e sales mobotix com System Manual Part 1 Installation 24 2 1 3 With T24 Info2wire And T24 DoorMaster To be able to use a bell wire already laid in the building to connect the T24 door station to the network and supply it with power the T24 version with Mx2wire technology is required The two wire cable must be conducted from the door station info module to a second Mx2wire unit inside the building to which data and power is supplied for example via a PoE switch Installing a T24 DoorMaster with decentralized access code memory makes it impossible to open the door by bypassing the connection cable and therefore protects against unauthorized access A battery kept fully charged via MxBus at all times supplies power to the electric door opening mechanism even in the case of a power failure Outdoors Indoors Power supply Power supply 48 57 6 AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 56 1
48. a storage for approx 250 one minute video clips or 60 000 VGA images 99 mm Integrated 4 GB MicroSD card 4 Speaker LEO LEDs Light button 99 mm Door bell Lens Microphone MxBus connector Seal Mini USB for future expansion modules Network connection Bayonet catch MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Outdoor Station Technical Specifications T24 CamCore Model versions Secure Secure Night T24M Sec Night NTT Lens options L11 Hemispheric 360 Sensitivity Color version 1 lux t 1 60 s 0 05 lux t 1 1 s B W version 0 1 lux t 1 60 s 0 005 lux t 1 1 s Image sensor 1 2 CMOS progressive scan Color 2 048 x 1 536 3MEGA B W 1 280 960 MEGA Selectable image formats 160 x 120 to 2 048 x 1 536 color Image formats PTZ view Quad view Panorama widescreen image Double Panorama Panorama Focus with 3 views Max image resolution Max frame rate M JPEG live recording Max video stream MxPEG live recording audio VGA 25 fps TV PAL 18 fps MEGA 8 fps 3MEGA 4 fps VGA 30 fps TV PAL 30 fps MEGA 30 fps 3MEGA 20 fps Image compression MxPEG M JPEG JPEG H 263 and H 264 only with Video VoIP Internal DVR 4 GB MicroSD card camera internal recording max 32 GB usable i Directly on NAS and PC Server without additional Exter
49. agement and supervision of a qualified electrician in accordance with electrotechnical regulations Legal Aspects Of Video And Audio Recording When using MOBOTIX products privacy and data protection regulations regarding video and audio recording must be observed Depending on the country and ins tallation site of the IP Video Door Station the recording of video and audio data may be subject to special constraints or may be prohibited All users of MOBOTIX products are therefore requested to inform themselves of and comply with all currently applicable regulations MOBOTIX AG will not assume any responsibility for product use that does not comply with the local laws Network Security MOBOTIX products combine all necessary configuration options for operating in Ethernet networks in a manner that complies with data protection regulations The operator is responsible for the data protection concept across the entire system The necessary basic settings to prevent misuse can be configured in the software and are password protected This prevents unauthorized access by unknown parties Risk Of Overheating When Exposed To Direct Sunlight When mounting black dark gray or amber colored T24 IP Video Door Stations in locations where the device is exposed to direct sunlight the housing temperature can exceed the maximum allowed temperature limit This can result in electronic failures and injuries especially when touching exterior metal parts
50. all MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 6 length for the battery opener cont nues nin the event failure T24 DoorMaster Technical Specifications T24 DoorMaster Functions Security door opener with internal access code memory Interfaces MxBus max 50 m distance to door station User interfaces 2 status LEDs 2 function buttons integrated speaker doorbell 2 galvanically separated inputs with shared ground connection AC DC self powered 50 V lisolated relay output AC DC 24 V 1 A or Outputs 1 connector for standard door opener 6 12 V AC 1 output for MOBOTIX anti theft protection 12 V DC Inputs Protection class IP 20 DIN EN 60529 Operating temperature 5 C to 40 C 23 F to 104 F DIN EN 50125 Power supply MxBus Power consumption typically 1 W Output max 10 W Switch time max 5 5 Connecting wire thickness Cable cross section 0 14 to 2 5 mm diameter 0 4 to 1 6 mm Dimensions W x H x D 80 mm x 80 mm x 41 5 mm The battery pack supplies the electrical door opener and in the event of a power failure the keypad which continues to guarantee that the door can be unlocked multiple times For installations in living areas the T24 DoorMaster functions also as a doorbell Supported Door Versions An electrically operated standard door opener 6 to 12 V AC min
51. and it will be extended and complemented with other new products For example a suitable bell module with up to four keys and integrated RFID technology will soon be available And the best part for all MOBOTIX customers all future T24 innovations are also compatible with T24 systems that have already been purchased MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Configuration Examples 24 examples in all MOBOTIX colors Only white and silver colored IP Camera Camera Camera Camera Camera in single frame in single frame in single frame in single frame in single frame Video Door S PW SV DG BL AM should be exp to direct sunlig risk of overh on dark surfa Camera and Camera and Camera and Camera and Camera and keypad keypad keypad keypad keypad in double frame in double frame in double frame in double frame in double frame PW SV DG BL AM Camera and Camera and Camera and Camera and Camera and info module info module info module info module info module in double frame in double frame in double frame in double frame in double frame PW SV DG BL AM Camera keypad Camera keypad Camera keypad Camera keypad Camera keypad and info module info module info module and info module info module in triple frame in triple frame in triple frame in triple frame in triple frame PW SV DG BL A
52. anel on tightly Secure the front panel using the panel s stainless steel screw s Make sure not to block the holes in the front panel air circulation Following installation and inital operation the T24 DoorMaster batteries should be charged continuously for the first 12 hours This takes place automatically via the PoE powered T24 door station using the MxBus two wire cable During this time the electric door opening function should not be used except for a short functional test This will maximize and extend the battery life of the high quality NiMH battery industry standard to several years at normal use When replacing the batteries always be sure to use original batteries You can purchase these directly from MOBOTIX or your MOBOTIX partner MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 6 Installing The Indoor Unit T24 Info2wire 2 6 1 Overview Of Mx2wire Technology And Connectors The Mx2wire technology that is optionally available with the T24 is used to connect the door station to the network via a simple two wire cable such as the connection cable of an existing doorbell An Mx2wire set always consists of two devices that communicate with one another the T24 Info2wire info module in the outdoor station and the compact indoor unit In addition to data power is also supplied via the two wire cable to the
53. any www mobotix com sales mobotix com 8 x signal inputs System Manual Part 1 Installation 24 Example Connecting A Lamp That Is Supplied With 230 V Connect power relay for lamp e First wire eLi terminal e Second wire to power supply e Third wire to lamp e Fourth wire to 230 V Connect external power supply for relay e g 12 V AC e First wire to eLi c terminal e Second wire to power relay Connect lamp e First wire to power relay e Second wire to 230 V Power supply 230 V AC e g 12 V AC b ERT Do i Lamp clive a eli Bpc Dpc Auth S2 Caution Electrical systems and equipment may only be set up changed and maintained by a qualified electrician or under the management and supervision of a qualified electrician in accordance with electrotechnical regulations MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Connecting External Devices To The Door Station Example Connecting Up To Four Bell Buttons Connect bell buttons e First wire to terminals 7 1 to 7 4 1 to 4 bell buttons e Second wire to power supply Connect power supply e First wire to terminal b e Second wire to bell buttons power supply e g 12 V AC MX MX ERT Do eLi c eLi Bpc Dpc Auth S2 PIR Connect 2nd to 4th doorbell buttons 7 4 to 7 1 7 4 similar to
54. as a doorbell The device features two status LEDs and two function buttons doorbell door opener MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Individual Components Outdoors 24 T24 Components Outdoors Terminal boards 24 Securely connects the camera module with the mounted 8 wires of the network patch cable via RJ45 connector Only for T24 versions without Mx2wire MX OPT IO2 T24 OPT IO The board provides an additional 8 signal inputs and 3 signal outputs to connect external devices doorbell light etc MX OPT IO1 Modules T24 CamCore Fisheye lens for 360 panorama view and inte grated live image correction high resolution 3 1 megapixel color sensor speaker microphone and 4 GB data storage for approx 250 one minute video clips or 60 000 VGA images T24 KeypadRFID Keyless and scheduled access This requires the user to enter a code or it can open the door in response to an RFID transponder card The voice mailbox can also be operated via the keypad MX KeypadI EXT MX T24M Sec D11 T24 Info Provides the option to display the house number and or name to the door station The module is equipped with permanent backlighting using energy saving and long lasting LED technology MX Info1 EXT T24 Info2wire The info module with Mx2wire technology and a second Mx2wire unit for
55. ash card up to 64 GB without requiring an external storage device or computer and with no additional network load The storage space is for up to 800 000 panorama images or 66 hours of video recordings Keypad With Contactless RFID Technology T24 KeypadRFID This MOBOTIX developed module can be used for several functions Outdoors it functions as the access control interface either by entering a code on the keypad or by means of keyless access using a transponder as a check card The module can also be used by visitors and residents to record and play back messages Info Module With Without Mx2wire Technology T24 Info T24 Info2wire MOBOTIX The info module features a backlit house number field and may also include an optional Mx2wire unit This unit is needed if the outdoor station is to be connected to the PoE switch with an existing bell wire via a second Mx2wire indoor unit instead of directly using an Ethernet cable T24 DoorMaster With Backup Power Supply Battery The door station may be coupled with a T24 DoorMaster with access code memory making it impossible to open the door by forcibly removing the system and bypassing the connecting cable A built in rechargeable battery powers both the electrical door opener and the keypad in the outdoor station and guarantees that the door can be accessed using a transponder or PIN even in the case of power failure For indoor installations the T24 DoorMaster also functions
56. ble to open the door from the outside MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com System Manual Part 1 Installation 24 2 9 Installation In The Siedle Vario System 2 9 1 Integrable Modules When used together with the expanded IO terminal board T24 OPT IO the hemispheric camera module T24 Cam Core of the T24 IP Video Door Station can also be integrated into a Siedle Vario system to work with the Siedle modules described here Siedle products modules frames network devices and so on cannot be ordered from MOBOTIX In contrast to the MOBOTIX system the Siedle Vario system has no tamper proof door opener control Call Buttons TM 612 1 2 3 4 The modules differ by the number of call buttons 4 max The label fields also have different sizes The call buttons are offset from the illuminated label field and marked by an illuminated bell symbol Polycarbonate front panel and transparent name labels that can be replaced from the front without tools 99 x 99 mm W x H Individually printable 91 x 84 mm LED backlit operating Security Vision Systems current 25 mA label field with insert for house number company logo business hours etc 99 x 99 mm W x H LED Spot LEDS 600 0 For illuminating house numbers or call buttons for example Featuring an energy saving and long lasting LED bulb IP54 weatherproof The spotlight may not be positi
57. cabling involved either a standard Ethernet cable for example CAT7 or existing bell wire is sufficient to connect the door station to the network in the building and to supply it with power Only a PoE Switch is necessary to connect remote stations VoIP video phone or computer and supply power The PoE switch can be located in an electrical cabinet for example Hemispheric camera Allround view with no blind spots with internal co Ss memory speakerand microphone Keypad Keyless entry RFID amp PIN voice mailbox operation Info module Optionally with integrated Mx2wire unit fo connect the T24 via bell wire data and power MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 15 148 Hemispheric Door Camera With Allround View And No Blind Spots T24 CamCore With 3 1 megapixels and an internal memory this hemispheric door camera records the entire entrance area No blind spots from wall to wall and from floor to ceiling The camera can record events automatically For example when someone rings the doorbell or if something moves in front of the door The camera module with a remote station can be used as a compact basic video door station thanks to the integrated doorbell and light buttons The camera saves high resolution video with lip synchronous sound directly to the integrated MicroSD fl
58. d electromagnetically The door at the exterior entrance can now be opened As soon as the door is fully closed again the latch in the door opener is automatically blocked The door is locked once again The approval to open the door can be indicated by various means e g dialing tone Door openers are primarily intended for daytime use At night the door in question should be locked using the bolt lock MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 140 148 141 148 DynDNS Abbreviation for Dynamic DNS or DDNS Dynamic Domain Name Service Similar to DNS this links domain names e g mydomain com with IP addresses whereby the IP addresses may change at any time This service provides a convenient method to access your MOBOTIX cameras from home or work if the camera Internet connection is not through a router that assigns a fixed IP address but instead over a DSL connection with a dynamically assigned IP address from the provider A well known provider of this free of charge service is www dyndns org DVR Abbreviation for Digital Video Recorder Ethernet Ethernet is the most widely used LAN technology Twisted wire pairs with special quality features are normally used for Ethernet LANs The most widely used Ethernet systems are TOBASE T and 100BASE T10 which enable data transfer rates of up to 10 Mbps and 100 Mbps Factory Defaults These are the settings with whic
59. e from diecast zinc and a combination frame including a circumferential seal made from extruded aluminum sheathing 132 Frame dimensions in mm for one to four modules vertically right or up to three modules each in a grid horizontally and vertically left 432 332 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 126 148 The ntegrated on wall casing has a depth of 36 5 mm The combination frame located above the wall has a depth of 15 mm Frame dimensions in 127 148 Installation In The Siedle Vario System MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 2 8 148 T24 System Manual Part 1 Installation 2 9 2 Determining The Installation Position Before installing the door station you need to decide exactly where to install it The system is generally installed so that the height from the ground to the upper edge of the frame is at least 1 60 m 5 ft 3 in Depending on the frame size and orientation the camera module T24 CamCore must always be placed in the top left position in the Siedle frame Always install the camera module in the upper left position inicr ir MOBOTIX The system offers options for both on wall and in wall installation Different installation sets are available for the two different options The camera module T24 CamCore can be used un
60. e Station Network Connection With Multiple Remote Stations Mounting The Frame And Housing Determining The Installation Position Inserting All The Cables Attaching The Housing Cabling In The On Wall Housing Mounting The Terminal Board And Fitting The Network Cable Sticking The Seal In Place Attaching The Frame And Connecting The Anti Theft Protection Mechanical Anti Theft Protection Lock Installing The T24 Modules Installing The Camera Module T24 CamCore Installing The T24 KeypadRFID Installing The Info Module T24 Info Installing The Info Module T24 Info2wire Labeling The Info Modules Removing And Exchanging Modules Installing The T24 DoorMaster Overview Of Connectors Connection Diagrams For Door Opener Versions Mounting Instructions Installation Using Cavity Or In Wall Socket Installing The Indoor Unit T24 Info2wire Overview Of Mx2wire Technology And Connectors Mounting Instructions Installation Using Cavity Or In Wall Socket Installation With Surface Mounted Socket Function Of Mx2wire Status LEDs MOBOTIX AG Security Vision Systems Made in Germany www mobotix com info mobotix com 2 1 Zl 2 12 23 24 24 9 2 2 2 2 1 22 2 2 2 3 2 3 2 3 2 3 2 2 3 3 2 3 4 1 3 5 2 3 6 23 7 2 3 8 2 4 2 4 1 2 4 2 2 4 3 2 4 4 2 4 5 2 4 6 2 5 2 5 1 2 5 2 2 9 9 2 5 4 2 6 26 1 2 0 2 2 6 3 2 6 4 2 6 5 2 7 Connecting External Devices To The Door Station 114 2 71 Usin
61. e Stations And Network Connection 2 2 3 Network Connection With Multiple Remote Stations If the door station is to be connected for operation with multiple remote stations computers with MxEasy or VoIP videophones in an existing network for example via an Internet box MOBOTIX again recommends using a MOBOTIX PoE adapter MX NPA PoE or a switch with multiple ports to supply power to the door station Connect the devices as shown in the following connection diagram Connection With PoE Switch Outdoors Indoors Connection With MOBOTIX PoE Adapter Outdoors Indoors LAN Power 5 MOBOTIX Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 Connection With Mx2wire And Optional 48 V Power Supply For a door station with integrated Mx2wire technology an external voltage source 48 V DC connected via two wires directly to one of the two T24 Info2wire units info module or indoor unit can also be used to supply power via the network cable Power supply Switch amp Router LAN Internet _ 4 MOBOTIX Door station T24 Info2wire VoIP video phone PC indoor unit Connection With Mx2wire And PoE Switch Switch amp Router LAN Internet t MOBOTIX Door station T24 Info2wire VoIP video phone PC indoor unit MOBOTIX AG Security Vision Syste
62. e T24 Info2wire info module to the indoor unit as an alternative to the outdoor station being directly connected to the network Recommendation existing previously laid bell wire core diameter 0 6 to 0 8 mm Max cable length 200 m JY A2Y YR 300 m NY 500 m Cat 7 Two wires from the door station to the T24 DoorMaster for connecting the MOBOTIX anti theft protection for unlocking when exchanging modules Recommendation black two wire cable already fitted to the frame possibly extended with YSTY telephone solid wire core diameter 0 6 to 0 8 mm Max cable length 50 m MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 0 58 148 The maximum configuration is specified for these cabling recommendations The suppl ed patch cable is used to connect the T24 Info2wire nfo module to the camera NY installation cable not live 59 148 Cable 6 may be used instead of cable 1 alternative connection option Overview Connection And Wiring Diagrams 12 V DC for Mediator 12 42 392 49 54 b Im 89 9 gt 0 way PoE switch remote station connection D 8 Cat 5 installation cable or higher Max length 100 m MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 1 5 Insta
63. enna is at the heart of this technology It is integrated into a carrier object for example an adhesive label or a plastic card The chip is normally used to store a numerical code This encrypts information that is stored in a database As a result every object with an RFID transponder has a unique identity When close to the antenna of a reading device passive transponders that do not have their own power supply are powered by means of inductive or capacitive coupling The data is also read out by means of coupling in the inductive field RoHS Abbreviation for Restriction of Hazardous Substances Directive refers to EC Directive 2002 95 EC which prohibits the use of certain hazardous substances when manufacturing products and components The goal of this directive is to prevent these substances from harming the environment when the products are disposed of later Router A device that determines the next network node to which a package is to be forwarded on its way to the target participant The router creates or maintains a special routing table which provides information on how particular destinations can be best reached Routers are sometimes integrated into network switches Search Monitoring of recordings or searching for a particular event Server Generally speaking a server is a computer program that provides services for other programs either on the same computer or on a different one A computer on which a server program
64. ensions for installation opening W x H x D flush with wall e Single housing 117 x 129 x at least 52 mm gt Double housing 117 x 218 x at least 52 mm 318 mm e Triple housing 117 x 318 x at least 52 mm 117 mm Make sure to install the in wall housing carefully using the inserted protective cardboard so that it is not deformed by any pressure from the surrounding material Otherwise the frame may not be installed properly and may not be sealed against the weather To prevent cement or plaster from soiling the inside of the housing insert the supplied protective cardboard again before installing the housing in the subsurface of the wall After you have secured the in wall housing you can easily remove the protective cardboard by pushing through the pre punched opening and simply pulling out the cardboard Pierce opening hole and pull through cardboard MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 4 Cabling In The On Wall Housing To prevent cables from being damaged when you mount the frame or the T24 modules make sure that the cables are routed correctly Please refer to the example cabling shown in the figure below The packaging material contains four blue cable binders that can be secured to eight designated cable receptacles using screws recommendation cross slot PH 2x100 Mounting points for
65. equently used in conjunction with IP telephony Structured Cabling Structured cabling is a standardized schematic diagram for the cabling of different services voice or data It facilitates the extension of a data network to allow for the subsequent installation of new components and therefore supports current and future communication systems This is generally based on a valid structure that contains reserves and can also be used independently of a particular application Structured cabling must be failsafe to ensure data protection and data security Subnet Subnet Mask A subnet is an identifiable separate part of an organization s network A subnet often represents all the computers within a geographical location building or LAN By dividing a network into subnets every subnet can be connected to the Internet using the same shared network address The subnet mask is that part of the IP address that is used by a network router to identify the subnet to which a data package is to be transferred The subnet mask saves the router from having to process the entire 32 bits of the IP address this way it can very quickly process only the bits indicated by the mask Switch Hardware used to connect multiple network devices computers cameras printers etc within a network A PoE switch can also supply the door cameras with power over an Ethernet cable Certain switches also function as routers Transponder A transponder is a device u
66. es securely back into the frame The modules can only be removed now after deactivating the anti theft protection Before operating the door station the batteries in the T24 DoorMaster must be fully charged maximum charging time 12 hours Finish the installation with Section 2 8 2 that follows MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 8 2 Configuring The T24 DoorMaster Before using the T24 DoorMaster it is essential to configure the signal output option to be used see Section 2 5 2 Three Options Are Available Option 1 Power Supply From T24 DoorMaster Battery Self Powered The door opener is supplied with a pulsed 12 V voltage max 10 W from the battery This state is signaled by a green LED in configuration mode As this is the factory default setting no further configuration is required for this connection option Option 2 Power Supply From External Power Supply Unit Internal Relay Function The relay integrated into the T24 DoorMaster switches an external voltage that powers the connected door opener This is signaled by a red LED in configuration mode Configuration is required here see below Option 3 Self Locking Mediator Door Lock Including UPS Via Battery Pack A DC control signal is switched to the control input of the Mediator special door opener that keeps the door permanentl
67. es that appear in this manual Manufacturer Executive Board MOBOTIX AG Dr Ralf Hinkel Kaiserstrasse 67722 Langmeil Germany Registration Office Kaiserslautern Local Court Germany Registration Number HRB 3724 Tel 49 6302 9816 103 Tax Code 44 676 0700 4 Fax 49 6302 9816 190 Tax Office Worms Kirchheimbolanden http www mobotix com VAT ID sales mobotix com DE202203501 You can find the latest version of this document at www mobotix com under Support CE Technical specifications subject to change without notice MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com T24 System Manual The HiRes Video Company MO BOTIX HiRes 3 Megapixel 2048 x 1536 Software zoom Skyline Format free Each image format freely definable Part 1 System Overview And Installation Installation and cabling for the installer 30 Frames s VGA 640 x 480 30 F s Mega Virtual PTZ Digital pan tilt zoom Part 2 Start Up And Configuration Software and network for the system administrator Backlight Safe using CMOS without mechanical iris Part 3 Operating Manual Modules and remote stations for the user Internal DVR Intemal via Flash external via Network Win Lin Mac Recording via Network on PC up to Terabyte Microphone amp specker Audio bi directional via IP variable framerates SIP Client with video IP Telephony
68. existing wires Part 2 of the System Manual will demonstrate how you operate the door station and configure it to meet your specific needs The two System Manuals are supplemented by an Operating Manual for the T24 IP Video Door Station If you would like to use a computer for the installation or as a remote station make sure to use the free MOBOTIX operating software MxEasy You can download MxEasy and its manual free of charge under Support on the MOBOTIX website Securty Vision Systems MOBOTIX If you have any questions our support and international sales staff are available at intl support mobotix com and sales mobotix com Monday to Friday 8 a m to 6 p m German time Calling support is free of charge not including your connection costs We would like to thank you for your trust and wish you all the best with your new high performance MOBOTIX T24 IP Video Door Station Security Vision Systems MOBOTIX WOBOLIX Made in Germany 2ecnujA AreioU 2Aejeuue alesemobotix com MOE 8 148 9 148 inside MOBOTIX The HiRes Video Company More security thanks to a maximum overv ew x HD 360 FullImage EMitire scene one view MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Hemispheric IP Video Door Station 24 What Are The Specific Advantages Of A MOBOTIX IP Video Door Station The new
69. f llt das bezeichnete Produkt die Bestimmungen der im Folgenden aufgef hrten Richtlinien The product oe Road above complies with the essential requirements of the relevant standard when used for ils intended purp Le brodul d sign rp PRA est conforme aux exigences fondamentales des normes s y rapportant EMV Richtlinie 2004 108 EG EMC directive Directive CEM Angewendete harmonisierte Normen EN 55022 2006 41 2007 CISPR 22 2005 1 Harmonised standards applied EN 55024 1998 A1 2001 A2 2003 Normes harmonis es EN 501 21 4 2007 EN 61000 6 1 2007 EN 61000 6 2 2005 Weitere angewendete Normen CFR 47 FCC Part 15B Other harmonised standards applied C Tick AS NZS 3548 Autres normes harmonis es Anschrift MOBOTIX AG Address Kaiserstrasse Addresse 67722 Langmeil Germany TK Nr Phone number de communication Fon 49 6302 9816 0 Fax 49 6302 9816 190 E Mail info mobotix com Dr Ralf Hinkel A il 06 04 2010 Vorstand CEO MOBOTIX AG Name und Unterschrift Ort Datum Place amp date of issue day month year Lieu et date Nom et signature MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Media Library MOBOTIX The HiRes Video Company Security Vision Systems MOBOTIX To demonstrate our confidence in the quality of our products MOBOTIX cameras were used to capture all the imag
70. f an image This is particularly important when transferring and saving files IP Address The IP address refers to the address of a computer or device in an IP network Using IP addresses all computer devices connected to the network can be identified and data can be transferred in both directions Every IP address must be unique to the network in question in order to prevent conflicts IP addresses can be assigned as fixed addresses so that they are never changed or they can be allocated dynamically and automatically via DHCP Every IP address consists of four groups or quads of decimal digits which are separated from one another by full points such as 130 5 5 25 Each quad within the address provides different information One quad represents the network number or address another the address of the local computer IP Camera An IP camera is a special type of video camera This kind of camera differs from other video cameras in that it forwards its images via IP networks Network cameras also include a computer in addition to the actual camera components The integrated computer deals with compressing the image data and ensures that data is sent via the network It mainly consists of a CPU Flash memory and DRAM memory The network camera software enables the device to appear in the network as a web server FTP server as well as an FTP client or e mail client IP Network Data network based on the Internet protocol TCP IP JPEG
71. fo2wire indoor unit to switches or routers that support the 10 100 Mbps network interface Check the LED activity of the corresponding port at the switch or router 2 2 2 Direct Connection Of One Remote Station If the door station is to be connected for operation to one remote station only computer with MxEasy or VoIP videophone MOBOTIX recommends using a MOBOTIX PoE adapter MX NPA PoE to supply power to the door station Connect the devices as shown in the following connection diagram Connection With MOBOTIX PoE Adapter Outdoors Indoors 2 gt Ta Il O camera fi The Grandstream videophone has two ETH connectors and it can alternatively be connected wirelessly to a network using a WLAN stick USB port MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 62 148 The MOBOTIX PoE adapter MX NPA PoE SET features a crossover function for direct computer connection and can either be connected to the mains supply or to other voltage sources 12 42 V 63 148 If multiple PoE supplied end devices such as several IP cameras are to be operated you should consider us ng a PoE switch The 124 with additional PoE power supply for example us ng the MOBOTIX PoE adapter and its remote stations can also be connected to an exist ng WLAN router with integrated switch function DSL box Remot
72. g The IO Module T24 OPT IO 114 2 7 2 Using The Keypad Signal Outputs 118 2 8 Finishing The Installation 120 2 8 1 Checking The Wiring And Activating The Anti Theft Protection 120 2 8 2 Configuring The T24 DoorMaster 122 2 9 Installation In The Siedle Vario System 124 2 9 1 Integrable Modules 124 2 9 2 Determining The Installation Position 128 2 9 3 Preparing Network And Power Connections 129 2 9 4 O Module And Terminal Connectors 130 2 9 5 Connections In The Door Station 132 2 9 6 Connecting Securing And Removing Modules 138 Download the latest version of this manual as a PDF file from www mobotix com Support gt Manuals All rights reserved MOBOTIX and MxEasy are registered trademarks of MOBOTIX AG Microsoft Windows und Windows Server are registered trademarks of the Microsoft Corporation Apple the Apple logo Macintosh OS X and Bonjour are trademarks of Apple Inc Linux is a trademark of Linus Torvalds All other marks and names mentioned herein may be trademarks or registered trademarks of the respective owners Copyright 1999 2011 MOBOTIX AG Langmeil Germany Information subject to change without notice MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com info mobotix com 6 148 T24 System Manual Part 1 Inhalt Important Notes Electrical Installation Electrical systems and equipment may only be set up changed and maintained by a qualified electrician or under the man
73. h a device leaves the manufacturer s factory when it is shipped If it is necessary to restore a device to its factory defaults all the settings changed by the user will usually be lost fps Abbreviation for frames per second See Frame rate Frame Rate The frame rate specifies how many frames per second fps are generated and sent by the camera 16 fps and higher is perceived by the human eye as a fluid video sequence G 711 The process or processes by which analog audio signals are encoded and decoded This codec enCOder DECoder is used in classic telephone systems and in IP telephony H 264 The processes by which the video image is coded compressed and decoded HDTV Abbreviation for High Definition TV which has a much higher resolution than conventional TV signals HiRes Abbreviation for High Resolution Refers to high resolution images above 1 megapixel Illumination In general a camera does not require additional lighting for use in daylight However some basic rules must be observed for use in the dark or under artificial light A suitable light source or supporting lighting must be selected depending on whether a general overview is required or whether people or objects have to be accurately identified MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 MOBOTIX Glossary 24 Image Compression Image compression reduces the file size o
74. h is also capable of connecting to the Internet such as the Fritz Box In this case and if only one T24 door station needs to be supplied with power it is sufficient to purchase one PoE injector When purchasing a switch with an additional PoE power supply make sure that a sufficient number of ports are supported this is especially important if other PoE supplied devices apart from the T24 are connected to the switch Furthermore it is crucial that the switch fulfils all the requirements for using the PoE supplied door station outdoors electromagnetic compatibility lightning and surge protection through galvanically separated ports MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 50 148 T24 Info2wire nfo module with indoor unit MOBOTIX Accessories 1 4 4 Additional Video Remote Stations Thanks to the use of network technology the T24 is not bound to just one expensive manufacturer dependent remote station It can be connected to any suitable VoIP video phone video H 264 sound G 711 in the world In addition to supporting the two way video communication feature with video and sound these devices support additional features such as door light control image search quick recording and PTZ functions So called SIP softphones are also suitable as remote video stations 1 4 5 Door Sensors Connection options are also provided on the door station for conventio
75. he installation cable with stripped ends to the corresponding contacts on the terminal board in accordance with the sticker fig standardized color coding according to TIA 568B Fasten the network cable so that its shielding rests on the terminal board contact field Using the enclosed cable tie X 5 6 0 Network cable retainer MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com sales mobotix com Mounting The Frame And Housing 75 148 2 3 6 Sticking The Seal In Place Remove the protection film and stick the supplied seal all the way round the inner housing frame ensuring it fits exactly and taking care not to leave any gaps Use a pair of scissors to remove any surplus material Please ensure that the adhesive surface is clean dry and free of grease On Wall Housing St ck the seal to the inner frame as Shown in the figure In Wall And Cavity Housing St ck the seal to the inner frame as Shown in the figure 1 1 1 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 7 Attaching The Frame And Connecting The Anti Theft Protection Before the T24 modules can be clicked into the frame you must screw the frame onto the housing recommendation cross slot PH 2x100 and lay the black anti theft protection cable to the inside of the building according to
76. he surface mounted socket Preparation Please refer to the figure on the right and use the surface mounted socket as a template to mark the drill holes Make sure that the alignment and position ofthe socketin relation to the two wire cable are correct TOP OBEN arrows Suppl ed rubber plug for 2 Feed in the two wire cable plus optionally the 48 V r sealing the two wire cable connector and screw on the surface mounted socket Feed the two wire cable through the opening provided that is sealed with a rubber plug Use the 8 wire plug for multi wire cables You only require two of these wires for T24 Info2wire The other two plugs with only one opening are ideally suited to insulated two wire cables of varying thickness Now use the four Torx screws to securely fasten the surface maximum mounted socket to the screw anchors or directly to of eight w res the wooden surface Please ensure that you only use the existing four drill holes of the surface mounted socket For cables with a 3 5 mm e d For cables with a 5 7 mm O 3 Remove the front panel and frame In order to protect the circuit board the board is attached to the front The screw does not need to be removed completely panel and frame in the original packaging To continue SEER front panel with the installation however you must first separate BS the board and housing from the panel and frame MEM Loosen the scre
77. holes MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com The nsert prevents the in wall housing from getting d rty and be ng deformed dur ng installation in a wall it must be removed and then positioned aga n when preparing the cables Mounting The Frame And Housing Important Pay Attention To The Position Of The Cables When installing the door station make sure that all the required cables network MxBus anti theft protection and so on are laid in such a way that they protrude from the wall directly below the housing openings provided This particularly applies to the on wall housing that has up to six cable guides triple frame Only one cable multi wire cables may be used should be inserted into each cable guide The cables should be long enough so that sufficient cable reserves remain to allow easy cabling within the housing see Section 2 3 4 Network cable e Position the housing in the center above the cables e Only use one cable in each cable guide e Make sure sufficient cable reserves are provided e Hint If longer cable reserves are required you can mount an additional in wall socket underneath the on wall housing see the dashed line in the figure above MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 3 Attaching The Housing On Wa
78. illion pixels MicroSD Card SD Memory Card Secure Digital Memory Card A digital storage medium based on Flash storage modules Motion Detection Detection and identification of movements within a particular area MOBOTIX cameras use algorithmic methods to detect changes from image to image in predefined areas while taking into account preset conditions If a camera detects a movement it signals an event and triggers an alarm MPEG Motion Pictures Expert Group Standard for compressing and saving image and video data resulting in quality loss Originally created for playing entertainment content on computers MPEG concentrates on displaying still image material and compromises the quality of moving image material in order to increase the transmission speed MxControlCenter MOBOTIX video management software for professional control of medium and large sized camera networks MxEasy Free of charge MOBOTIX video management software for small and compact camera networks of up to 16 cameras door stations MxPEG Method developed by MOBOTIX to compress and store image and video data with low network load and high image quality The MxPEG ActiveX control element allows video and audio data from MOBOTIX cameras to be displayed in other applications including Internet Explorer Network A group of end devices such as computers that are connected via various cables and share access to data and devices such as printers and IP cameras
79. inal Board T24 OPT ETH The ethernet terminal board T24 OPT ETH is used to connect the door station for the T24 versions without Mx2wire technology It securely connects the camera module with the 8 connected wires of the network patch cable via RJ45 connector for installation see Chapter 2 Ethernet connector with PoE supply Connector for the special patch cable Cable sheath of the T24 CamCore contact Only use original MOBOTIX cables to connect the camera Standard cables purchased from other suppliers do not meet the necessary specifications for proper fastening not impermeable weatherproof Ethernet patch cable MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 26 T24 OPT ET Outdoor Station The Ethernet terminal board is screwed on to the housing on wall or in wall behind the camera module AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 11 3 Access Module T24 KeypadRFID This module is used for keyless and scheduled access to the house or building with an access PIN or RFID transponder card Voice messages can also be spoken and played back using the keypad LED blue 9 LED green red 6 99 mm cy e Open door messages doorbell 10 key keypad 2 function ke
80. inal b to b connect module terminals c and G ground to c connect module terminal B motion to IO module PIR 9 Siedle Info Module For switchable internal module lighting iLi connect module terminal to connect module terminal b to module iLi e J e v 0 gt 5 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 134 148 Module Module Motion Detector PIR Info Module iLi 135 148 Installation In The Siedle Vario System Siedle LED Spotlight For switchable internal module lighting iLi connect module terminal 6 to connect 0 LED Spotlight module terminal b to IO module iLi Module LaL b The protruding casing of the spotlight can slightly limit the maximum area recorded by the camera External Light Via 230 V Relay For switching an external lamp above the door station at the entrance for example you need a connection from c to the IO module isolated output connect relay input A1 to b connect IO module eLi c to c control voltage connect relay input A2 to module eLi signal Board Transformer eLi c C Board Transformer signal b hy EJ L L AG Security Vision Systems Made Germany www
81. it to connect to the network and to supply power Remote Stations IP video telephone MOBOTIX recommends the GXV3140 from Grandstream as a remote video station for the T24 door station This modern IP video telephone is based on the world standard in telephony VoIP SIP with H 264 and provides a large color LCD display with excellent image quality Grandstream GXV3140 MxEasy video management software MOBOTIX provides the MxEasy software for Windows Mac and Linux free of charge to configure and operate the T24 IP Video Door Station with a network enabled desktop or notebook computer Free of charge Accessories NPA PoE Set The MOBOTIX Network Power Adapter Set NPA PoE set is a high quality robust ultra compact and above all multifunctional PoE injector with three connectors network camera PoE device and a universal power supply unit with adapter plugs The Network Power Adapter Set remotely supplies the T24 door station and all other PoE devices with power in accordance with the IEEE 802 3af standard It is therefore possible to secure the power supply for distances up to 100 m 300 ft using the network cable As a result the T24 IP Video Door Station can be supplied with PoE power via the adapter and connected directly to a Grandstream video telephone or to a computer integrated crossover function amp x AG Security Vision Systems Made in
82. ium sized business premises The most important usage options are residential buildings apartment buildings offices and business premises as well as other entrance and gateway areas that are not visible or are difficult to see from inside personal security checks for public authorities institutions and for other exposed areas e g EDP VoIP Voice over IP Telephony using computer networks Wizard Refers to a software component that helps the user to install or set up a particular program and guides the user through the configuration process by means of simple questions WLAN Wireless LAN A wireless LAN that transfers data over the mobile radio network The end user is wirelessly connected to the network while data transfer across the network s main structure usually remains cable based MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Declarations Of Conformity 24 T24M Hemispheric Camera Konformitatserklarung Declaration of Conformity D claration de conformit Hersteller MOBOTIX AG Manufacturer Fabricant Produkt Netzwerk Kamera Product Network camera Produit Cam ra de r seau Typ T24M inkl evtl verbautem IO Modul oder Ethernet Type Anschlussplatine Type incl optionally installed IO module or Ethernet connector board avec module IO ou platine de connexion Ethernet optionnellement Bei bestimmungsgema8er Verwendung er
83. iversally for both installation options In addition to the most popular vertical mounting option horizontal mounting of the Vario frame is also possible by rotating the camera module correspondingly when placing it into the installation frame Detailed instructions for in wall and on wall installation of the Vario system are included in the Siedle packaging MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installation In The Siedle Vario System 1 2 9 148 2 9 3 Preparing Network And Power Connections The door station requires the following basic cabling e Ethernet cable from the PoE switch or from a router with additional PoE power supply e Two wires for powering the Siedle modules from the transformer in the electrical cabinet gt C Two wires for the anti theft protection controller in the electrical cabinet optional D Two wires for the 230 V light relay e Cables to the external door opener door contact and door lock switch Safety Warning Never connect or handle live cables for example a 240 V power supply on your own always have a trained electrician do the installation Recommendation For Cabling As a specification for cable line A network MOBOTIX recommends using a category 5 BE cable is Cat 5 Ethernet installation cable or higher For cable lines B C and D we recommend designed for laying an 8 or 10 wire YSTY telephone
84. ll Fig Triple Housing Drill the four holes and insert the screw anchors drilling template is included Ensure that the Oben Top label points upwards Hs TOP 55 applies to horizontal and vertical installation Attach the on wall housing using four Torx screws and the supplied Torx wrench HO 6 9 4 9 Ce e war Horizontal installation Ve t al instalation Cavity Fig Triple Housing When installing the housing in a cavity wall tighten the cross head screws embedded in the housing corners until the four retaining wings swing out and clamp the housing tightly to the cavity wall Retaining wings for cavity installation 318 mm 117 mm MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com sales mobotix com 70 148 The required installation open ng has the following d mensions width x height Single hous ng 117 x 129 mm Double hous ng 117 x 218 mm Triple housing 117 x 318 mm Permissible wall th ckness m n 7 mm max 27 mm 7 27 mm Mounting The Frame And Housing 7 148 In Wall Fig Triple Housing Hint Turn the n wall socket over and use it as a template to mark the hole Connect the housing with the subsurface so that the bars fitted to the edge are still visible The required opening should be 116 x 318 mm Turn the housing over and use it as a template to mark the holes Lead ng edge of housing Dim
85. llation Tip Replacing An Existing Doorbell With The T24 The MOBOTIX T24 IP Video Door Station in particular the version with integrated Mx2wire technology for network connection with simultaneous power supply via the same two wire cable is an ideal retrofit solution that is very easy and quick to install The following two installation steps are normally all that is required to replace an existing simple doorbell with a complete T24 set including a T24 DoorMaster Step 1 Connect The T24 Via The Two Wire Cable Unscrew and remove the doorbell Connect the wire pair to the T24 Info2wire info module T24 is mounted directly above the cable This wire pair is conducted directly to the electrical cabinet from where it is connected to the power supply and remote stations via the T24 Info2wire indoor unit Outdoors Indoors T24 Info2wire indoor unit 25 4 sal MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 60 148 61 148 Overview Connection And Wiring Diagrams Step 2 Install And Connect The T24 DoorMaster Install the T24 DoorMaster in a in wall socket on the wall behind the door station inside the building Besides the in wall socket only two holes are required for the entire cabling Hole A Use a long drill bit to drill a hole from the door station downwards at an angle through the brickwork to the in wall socket of the T24 DoorMaster on the interi
86. module MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 6 Connect all the other connection cables if present Standard door opener or relay for lights etc e First wire to COM terminal e Second wire to OUT A terminal External power supply for door opener or power relay for example 12 V AC e First wire to OUT B terminal Second wire to COM terminal Door opened closed door contact reed switch e First wire to IN 1 terminal e Second wire to IN 1 terminal Door lock unlocked locked door lock switch e First wire to IN 2 terminal e Second wire to IN 2 terminal x di FID Door contact Door ooo MX Door lock switch MX MX ay MX x IN 1 IN 1 2D Door opener power relay 8 7 IN 2 S 25 IN 2 co g i C COM p 5 2 COM gt Power suppl O Wer SU Sa OUTA Pply Se 12 V AC OUT B ZLD e g MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 148 Installing The T24 Modules 7 Put the cover plate back on 8 First of all insert the right side of the module into the frame Then press firmly on the left side until the module audibly clicks into place Control click If you do not hear a click this means that the module is not properl
87. ms Made in Germany www mobotix com sales mobotix com 64 148 An exist ng DSL box can also be used to connect the T24 Info2wire indoor unit instead of a switch Although a PoE Switch compl es with the IEEE 802 3at standard using a 48 V unit to supply power is normally the more economical option if only one end device powered via PoE is to be operated 65 148 Remote Stations And Network Connection Connecting Multiple T24 Door Stations In general a PoE switch can be used to connect several T24 door stations to the same remote stations However only one T24 can be connected to a T24 DoorMaster Each transponder card can be programmed in such a way that it can be used on all the existing T24 door stations for opening the door Outdoors Indoors MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 3 Mounting The Frame And Housing A complete T24 door station system includes components that are mounted next to the entrance door which means they are usually installed outdoors as well as components such as the T24 DoorMaster remote stations and power supplies that are installed inside a building Please note that only the T24 camera keypad and info module are suitable for outdoor installation IP65 30 C to 50 C 22 F to 122 F The modules will only be weatherproof if they have been
88. n Allround View With No Blind Spots Overview Of Modules Individual Components Outdoors Individual Components Indoors Configuration Examples System Image System Overview Outdoor Station Hemispheric Camera T24 CamCore Ethernet Terminal Board T24 OPT ETH Access Module T24 KeypadRFID Info Module T24 Info T24 Info2wire Info Module With Indoor Unit Housing And Module Frames T24 DoorMaster Remote Stations Grandstream IP Video Telephone GXV3140 MxEasy Video Management Software Accessories NPA PoE Set T24 OPT IO Extended Terminal Boards Additional Devices For PoE Power Supply Additional Video Remote Stations Door Sensors Electrical Door Opener 1 1 1 1 1 11 2 11 3 11 4 11 5 11 6 1 2 1 3 1 3 1 1 32 1 4 1 4 1 1 4 2 1 4 3 1 4 4 1 4 5 1 4 6 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com e info mobotix com 2 52 52 54 56 58 60 62 62 62 63 66 66 68 70 72 74 75 76 78 80 00 84 88 90 92 94 96 96 98 100 103 106 106 108 109 113 System Manual Part 1 Contents 24 Installation Overview Connection And Wiring Diagrams With A T24 DoorMaster Without A T24 DoorMaster With T24 Info2wire And T24 DoorMaster Recommendation For Cabling Installation Tip Replacing An Existing Doorbell With The T24 Remote Stations And Network Connection Notes On Cable Lengths And Power Supply Direct Connection Of One Remot
89. n cables have more than two wires make sure color coding that the same cable pair is used for both Mx2wire units see figure Approximately 5 mm of insulation must be stripped from both ends of the two wire cable T24 Info2 wire info module T24 Info2 wire indoor unit Prior to installation test the cable connection to ensure that it is functioning properly if necessary draw up a test chart MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 108 148 Cable with wire end sleeves for flexible cores Installing The Indoor Unit T24 Info2wire 2 6 3 Installation Using Cavity Or In Wall Socket 1 Prepare the cavity or in wall socket see Section 2 5 3 2 Screw the two wire cable to terminals 1 and 2 The cable does not necessarily need to be attached to the terminal with the same number on both T24 Info2wire units The device continues to function if connectors 1 and 2 are swapped Connectors 3 and 4 are only assigned if an external voltage source 48 57 V DC is used 3 Remove the front panel and frame In order to protect the circuit board the board is attached to the front panel and frame in the original packaging To continue with the installation however you must first separate the housing and board from the panel and frame Loosen the screw in the front panel and lift the panel forwards Now remove the attached frame from the circuit board Please
90. nal door and door lock switches open close door open close lock 1 4 6 Electrical Door Opener The T24 Door Station should always be connected to an electrical door locking system which can be activated via the T24 DoorMaster in a tamper proof manner Product Information Self Locking Door Lock Traditional door openers only electromechanically release a locking tab on the door In order to open an additional key locked door without using the key and as described above a door lock that can be locked unlocked electrically is required instead of a traditional door opener e g Mediator www assaabloy de This also applies when the door in question has to be locked at all times for insurance reasons and the keyless door opening function of the T24 is to be used as well transponder PIN MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 5 2 148 T24 System Manual Part 1 Installation 2 INSTALLATION 2 1 Overview Connection And Wiring Diagrams The following diagrams are an overview of the wiring plans that will allow you to connect the T24 IP Video Door Station as intended Please refer closely to the configuration that best suits your particular needs 211 With A T24 DoorMaster Using a T24 DoorMaster with decentralized access code memory makes it impossible to open the door by bypassing the connection cable thereby protecting your system against unauthorized access A batte
91. nal video storage recording software Software included MxEasy video management software Backlight compensation automatic white balance Image processing image correction incl panorama image correction video sensor motion detection Virtual PTZ Digital pan tilt zoom continuous 8x zoom Triggering of events through integrated multiple window motion detection temperature sensor notification over email FTP IP telephony VoIP SIP visual acoustic alarm pre and post alarm images Audio Microphone speaker G 71 lip synchronous sound Video telephony VoIP SIP two way video communication remote controlling with key code event notification Security User group management HTTPS SSL IP address filter IEEE 802 1x intrusion detection digital image signature Certificates EMV EN50121 4 EN55022 EN55024 EN61000 6 2 58 AS NZS3548 Power over Ethernet PoE in accordance with IEEE802 3af PoE Power supply class variable depending on operating mode power consumption typically 3 W via PoE switch MOBOTIX PoE adapter Mx2wire Operating conditions IP65 DIN EN 60529 30 C to 50 C 22 F to 122 F Interfaces MxBus USB Ethernet Dimensions W x H 99 mm x 99 mm MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 1 1 2 Ethernet Term
92. nder the German Product Liability Act the manufacturer or retailer is liable for the product that they have brought to market Claims are only possible when the product is used in accordance with its intended use and there is no evidence of misuse The technical specifications and information described in the T24 System Manual must be observed Otherwise the manufacturer is released from their product liability in accordance with the German Product Liability Act PTZ Abbreviation for Pan Tilt Zoom Refers to the movement of a video camera to the left and right up and down and to the camera s ability to enlarge an image Resolution Indicates the number of pixels used to produce an image The more pixels an image has the more recognizable the details remain when the image is enlarged The resolution is expressed as the number of pixel columns by pixel rows or as a total number of pixels A VGA image has 640 columns and 480 rows 640 x 480 which equals 307 200 pixels or approximately 0 3 megapixels The T24 has 3 1 megapixels MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 144 148 145 148 RFID Radio Frequency Identification RFID enables data to be transferred contact free and out of sight using radio waves An RFID system infrastructure comprises a transponder a transceiver device and an IT system operating in the background The transponder a tiny computer chip with an ant
93. nerally be mounted in the MOBOTIX T24 frame MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 For power supply to supported Siedle modules Transformer in switchboard casing Voltage 230 V AC 10 50 60 Hz output voltage 12 V AC output current max 2 5 A protection secondary short circuit proof protection class IP 20 ambient temperature 0 to 40 C 32 F to 104 F Transformer TR 602 01 Electronic Anti Theft Protection DSC 602 0 With ZDS 601 0 Additional protection against unauthorized removal of modules The module consists of the Anti Theft Protection ZDS and the Controller DSC The ZDS is fitted to the bar s of the installation frame and securely seals off access to the opening mechanism The anti theft protection controller is located in the distribution box inaccessible from outside On Wall Casing GA 612 XX With Installation Frame MR 611 XX Siedle Vario on wall casing made from extruded aluminum sheath with diecast zinc corner connectors and steel base plate for a maximum of six function modules Completely powder coated or painted suitable for horizontal and vertical mounting Matching installation frame included Siedle Vario casing for in wall installation The system includes in wall casing constructed from robust plastic for a maximum of six function modules a matching installation frame mad
94. nnector Please read further information on the connection details and on using this product in Section 2 7 1 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 1 4 3 Additional Devices For PoE Power Supply By default power is supplied to the T24 IP Video Door Station via the network cable that is connected to the Ethernet terminal board behind the camera module PoE injectors or switches with integrated PoE power supply according to IEEE 802 3af can be used to supply power to the network PoE switch PoE According To IEEE 802 3at For Mx2wire the T24 version with Mx2wire technology is installed data and power are supplied to the door station via a two wire cable which is connected to the network via an Mx2wire indoor unit Due to the increased energy requirements of the Mx2wire technology PoE supply according to IEEE 802 3af is not sufficient A PoE injector switch performance class PoE according to IEEE 802 3at has to be used instead or an external voltage source 48 V DC must be connected to one of the two Mx2wire units info module or indoor unit Switch Or PoE Injector A switch connects individual network enabled devices to one another and delivers data In the case of a home network this function is normally performed by an existing router with multiple network ports whic
95. obotix com Integrated e unlocking funct Installing The T24 DoorMaster T24 DoorMaster System Overview Door station T24 DoorMaster e Door contact me Sa 2 Door opener 2 Door lock switch MxBus 2 Anti theft protection 2 Anti theft protection Anti theft protection OUT 1 Door opener OUT Door opener OUT 2 Door lock switch Door contact IN MxBus MX Door lock switch IN 2 MxBus MX Door contact IN 1 Supported Door Opener Versions A standard door opener operated with 6 to 12 V AC can be connected directly to the T24 DoorMaster and powered by its integrated battery pack There is no need to connect an additional power supply unit A door opener with an external power supply of up to 24 V AC DC max 1 A may also be connected as may the self locking Mediator door lock MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 5 2 Connection Diagrams For Door Opener Versions Version 1 Power Supply From T24 DoorMaster Battery Self Powered The T24 DoorMaster s permanently charged battery pack provides a supply voltage to the door opener and therefore also bridges power failures T24 DoorMaster EU SW IN 1 21 Door contact IN 2 Door lock switch OUT 1
96. oned directly above the camera module 99 x 99 x 36 mm W x D MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Siedle info mod without Mx technology Installation In The Siedle Vario System Motion Sensor BMM 611 0 Detects within a terminable range max horizontal detection angle 180 infrared rays as emitted by people and can activate the light for example The system contains a E highly sensitive infrared sensor The horizontal detection area and the detection range may be adjusted as necessary 99 x 99 x 25 mm N XH x D Electronic Key Reader ELM 611 01 with EK 601 0 or EKC 601 0 Contactless access control system with function LED For use Ss avis as a reader unit for a maximum of 9 electronic keys LEE EK 601 0 or key cards EKC 601 0 to open doors gates etc 4 Keys and cards do not require a battery 99 99 mm W Fingerprint Reader FPM 611 01 In this system the unique biometric features of the human finger are used to gain keyless access Never worry about lost misplaced forgotten or stolen keys again Several fingers may be read from each person A maximum of five groups may be configured With function LED 99 x 99 x 17 mm WxHxD Placeholder BM 611 0 Dummy module to cover empty slots or placeholder for future expansions 99 99 mm W Siedle Vario modules can also ge
97. onitors in a specific environment for example within a building The term CCTV is often used for video surveillance systems CIF 2CIF ACIF acc to PAL Common Intermediate Format CIF 1 4 TV image with 288 lines and 352 pixels 0 1 megapixel 2CIF 1 2 TV image also with 288 lines but 704 pixels 0 2 megapixel 4CIF quality of a conventional TV image with 576 lines and 704 pixels 0 4 megapixel CMOS Sensor Abbreviation for Complementary Metal Oxide Semiconductor sensor Sensor for energy efficient digitization of image information CMOS sensors are used as image sensors in digital cameras DHCP Abbreviation for Dynamic Host Configuration Protocol Allows a server to automatically assign devices in the network with the appropriate configuration including the IP address DNS server and gateway as opposed to static IP addresses on the individual network devices DNS Abbreviation for Domain Name Service Allows the domain names of servers on the Internet for example www mobotix com to be linked resolved to their corresponding IP addresses for example 212 89 150 84 Door Opener The door opener also known as e opener electric door opener is installed complementary to the door lock The door opener has a closing latch which connects with the door closer and keeps the door locked until contact is made from the interior of the building This contact raises the lock of the door opener latch and the latch is unlocke
98. or wall surface Insert a 4 wire cable for MxBus and the anti theft protection see Section 2 1 4 Recommendation For Cabling Hole B Use a shorter drill bit to drill a hole through the brickwork from the door lock door opener to the in wall socket of the T24 DoorMaster Feed the connectors for the door opener door contact and door lock switch through this hole see Section 2 5 Installing The T24 DoorMaster Indoors Please contact a specialist e g a locksmith for the installation and selection of any components that may be required door opener magnetic sensors Door openers and door contacts are available as accessories from other suppliers e g www assaabloy com MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 2 Remote Stations And Network Connection 2 21 Notes On Cable Lengths And Power Supply The 24 door station can only be powered using the Ethernet port of the door camera A MOBOTIX PoE adapter MX NPA PoE or other similar high quality PoE product conforming to IEEE 802 3af is required to supply the T24 with power PoE switch A PoE switch IEEE 802 3at or a 48 V power supply unit can be used to supply power to the T24 version with Mx2wire technology The maximum length of the network cable for power supply over an Ethernet cable is 100 m Make sure that you only connect the door station or T24 In
99. or opener door and door lock switches floor call and external light Module retainer in Siedle Vario housing MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installation In The Siedle Vario System Mounting The IO Module And Terminal Connectors After installing the on wall or in wall frame note the Top Oben indicator fasten the individual module terminal connectors by positioning and simultaneously rotating them by hand from approx 10 to 12 o clock Fasten the IO module which must always be placed behind the camera module in the same manner To simplify installation we recommend connecting the IO module to the network cable first see the following section The figures show the correct final position of the connector terminals and IO module for both vertical and horizontal mounting of the door station Connecting The Network Cable To The IO Module See Section 2 3 5 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 132 T24 System Manual Part 1 Installation 2 9 5 Connections In The Door Station Circuit Overview Diagram Modules And Power Supply For an external 12 V AC power supply first run b and c in parallel from the Siedle transformer to the module terminal connectors and finally b to b on the IO module The b signal is not always switched to the
100. orrect 4 Screw on the anti theft protection coming from the T24 door station e First wire to OUT 1 terminal e Second wire to OUT terminal The device still functions properly if the wires are swapped 5 Screw on the electric door opener coming from the door e First wire to OUT 2 terminal e Second wire also to OUT terminal The device still functions properly if the wires are swapped MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 1 04 48 T24 System Manual Part 1 Installation 6 Screw on the door lock unlocked locked door lock switch coming from the door e First wire to IN 2 terminal e Second wire to IN terminal 2 4 The device still functions properly if the two wires used here operating contact and changeover contact are 2 swapped 8 7 Screw on the door opened closed door contact reed switch coming from the door 2 e First wire to IN 1 terminal e Second wire also to IN terminal d osos 5 The device still functions properly if the two wires used gl gp j here operating contact and changeover contact are 1 swapped 8 Remove the front panel and frame In order to protect the board the board is attached to the front panel and frame in the original packaging To continue with 2 2 the installation however you must first separate the A ho
101. ors are connected directly to the keypad In addition an external 12 V voltage is applied to the door mechanism Mediator and bridged over to the keypad The two cables for the electromagnetic anti theft protection integrated into the T24 frame otherwise connected to and powered by the T24 DoorMaster should be conducted inside the building so that they can be connected to a 12 V supply in case modules are exchanged later on Door Station Switch box Power supply MOBOTIX PoE switch Sry VoIP video phone The anti theft protection is connected to the DC power supply of the door opener via a switch switch on gt current is flowing gt protection deactivated If the door opener works with an AC power supply the anti theft protection requires its own DC voltage source MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com sales mobotix com 54 148 The figure above the connection sections represents the number of cable w res Black YSTY 0 8 recommended or 0 6 mm Orange Ethernet Cat 5 or higher The external 12 V supply can be bridged over from the Mediator to the keypad to avoid hav ng to use an additional 12 V cable to the keypad Overview Connection And Wiring Diagrams icm Sg v gt 5 gt 5 v Q c o c 5 gt TE i ee 5 0 o 5 8 9 5 5 5 5 a A a gw
102. ow Anti theft protection OUT OUT 2 Door opener Version 2 Power Supply From External Power Supply Unit Internal Relay Function The T24 DoorMaster s integrated relay function switches a maximum external voltage of 24 V SELV max 1 A T24 DoorMaster 972 4 IN 1 21 Door contact Door lock switch OUT 1 e L Anti theft protection Door opener Power supply MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 DoorMaster Version 3 Self Locking Mediator Door Lock Including UPS Via Battery Pack In this connection option the T24 DoorMaster s battery pack powers the system in the event of a power failure and allows the door to be opened without a key In this case however anti theft protection must be controlled using an additional switch to be ordered separately In the following diagram for example anti theft protection is used together with a Mediator power supply The modules can then be released by pressing the switch The anti theft protection must be disconnected from the voltage again after no longer than five minutes in the example switch S is off in order to avoid an overload T24 DoorMaster Mediator I 12 V DC SELV we Original Mediator Door station Power supply MOBOTIX AG Security Vision Systems
103. ower supply is necessary T24 KeypadRFID MX MX MX 4 MX IN 1 j IN l IN 2 Ist doorbell button IN 2 Connect 2nd doorbell button to IN 2 and IN 2 similar to 1st doorbell button MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 20 148 T24 System Manual Part 1 Installation 2 8 Finishing The Installation 2 8 1 Checking The Wiring And Activating The Anti Theft Protection After installing and connecting the door station you will need to test the power supply to the individual modules and the T24 DoorMaster Connect all the installed components T24 outdoor station T24 DoorMaster door opener Mediator door sensors light and so on and connect the power supply switch on PoE switch router and all power supply units used The MOBOTIX IP Video Door Station starts up after the power supply is connected The entire system starts up The buttons on the T24 CamCore light up for four seconds Without pressing a button wait until the lights go out after a few minutes and then light up again T24 CamCore keys light up T24 KeypadRFID LEDs flash green and blue T24 DoorMaster LEDs flash green and blue MOBOTIX The blinking of the green LED on the keypad and T24 DoorMaster indicates that data is communicated between the individual modules via Mx Bus but the data communication is still unencrypted After the system is started u
104. p see Part 2 of the System Manual the green LED lights up continuously MxBus data communication is encrypted The LED on the keypad lights up red when the communication of data via MxBus is interrupted for example if the camera module stops working MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Finishing The Installation Checking The Wiring Check LED on T24 Info2wire info module indoor unit Info module Green and orange LEDs light up Indoor unit Green LED flashes orange LED lights up Check lights on T24 Info info module LEDs on the info module light up Check camera lights T24 CamCore Buttons and light strips light up after boot phase Check LED signal on T24 KeypadRFID Blue and green LEDs flash Check LED signal on T24 DoorMaster Blue and green LEDs flash Y Check connection of door sensors S7 Close and lock door Blue LED of the T24 DoorMaster Rud 4 lights up green LED flashes Activating Anti Theft Protection Test the anti theft protection module by pressing and holding down the two buttons on the T24 DoorMaster until the blue LED blinks This deactivates the anti theft protection in the frame for 90 seconds see Section 2 4 6 Use the special key to release the module above the mechanical anti theft protection lock and turn the red button to the closed lock symbol see Section 2 3 7 Insert all the modul
105. p of the visitor all the way to an overview panorama The hemispheric T24 door camera T24 CoreCam has a virtual purely digital PTZ feature pan tilt zoom The image captured by the hemispheric camera can be zoomed smoothly and you can See ng simultaneously move to any section of the image in seconds for example using the scene with mouse or the four large arrow keys on the Grandstream video telephone left right up down This is similar to a mechanical PTZ camera but without the maintenance and wear A Superior Overview Increases Security The fisheye lens of the camera records the entire hemisphere of the scene without any blind spots and displays this image as the first part of the 360 full image Here there are technical limitations predominantly at the edges of the image where the geometric shape of the objects is heavily distorted making them difficult to for the human eye to evaluate T24 360 Full Image HD Super 180 Panorama For this reason the camera uses its integrated software to correct the images in the live view so that it can deliver user friendly images at the remote video station The operator can now digitally tilt pan and zoom the image from the comfort of the remote station MOBOTIX AG gt Security Vision Systems Made in Germany www mobotix com sales mobotix com 13 148 180 Field Of View With No Blind Spots Conventional door cameras have a standard 90
106. r Station A power relay can be connected to the door station via an external power supply max 24 V AC DC for the purpose of switching different types of devices for example outside lights garage doors alarm systems additional doorbells and so on Connection is either via the MOBOTIX IO module accessory T24 OPT IO or the keypad The T24 camera software is used to configure the switching of external devices and can be accessed via a standard web browser such as Internet Explorer For additional information on this topic see Part 2 of the System Manual 2 7 1 Using The IO Module T24 OPT IO Connect the IO module to the camera module T24 CamCore via MxBus which connects it the network It has eight physical signal inputs that allow it to distinguish in AC operation between a pending full wave and half wave This makes it possible to connect two switches to each signal input terminal so that 16 button inputs are made available The inputs can be used for e g bell buttons The outputs can be used for external devices such as a doorbell or for outdoor lights or garage door openers via a power relay 2 B I2V AC tp Ld Z T 0 9 s S e e MOBOTIX AG Security Vision Systems Made in Germany www mobotix com salesemobotix com see Section 2 T24 OPT I diagram with with a relay Connecting External Devices To The Door Station Terminal Connector Functions External
107. rd e First wire to Data 1 terminal e Second wire to Data 2 terminal MOBOTIX AG e Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 Modules 5 Remove the blue sealing plug on the module Feed the RJ45 connector of the extended camera patch cable into the housing and insert it into the RJ45 port Make sure that the rubber sealing ring on the patch cable is in the correct final position de a SD 6 49 Pe 8e un 6 Put the cover plate back on 7 Firstofall insert the right side of the module into the frame Then press firmly on the left side until the module audibly clicks into place Control click If you do not hear a click this means that the module is not properly mounted In this case repeat the last steps making sure that no cable or foreign object in the housing is preventing the module from properly clicking into place MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 5 Labeling The Info Modules The info module allows you to place a paper label or printer label behind the transparent cover You can use the enclosed permanent marker to personalize the paper insert by adding your name contact number house number and so on You will find a PDF template on the MOBOTIX website to help you create your own label
108. rity Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 Module Frame Fig Triple Frame 18 mm 131 mm Installation of module 333 mm Connection of anti theft protection Activation of anti theft protection Key to release the modules from the frame press upwards only possible after anti theft protection has been deactivated MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Outdoor Station T24 Modules Frame Terminal board Housing T24 CamCore With integrated Ethernet terminal On wall or T24 KeypadRFID anti theft board or in wall T24 Info T24 Info2wire protection IO module housing MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 12 1724 DoorMaster The T24 may be coupled with the T24 DoorMaster with internal access code memory making it impossible to open the door by forcibly removing the system and bypassing the connecting cable 80 mm LED blue LED green red 9 Speaker 80 mm Door opener emergency unlocking in the event of a power failure Volume of doorbell Connector for battery pack OUT 1 lt OUT OUT 2 5 er IN c 4 Oor 2 MX 5 2 J W
109. rt the supplied longer patch cable into the camera housing Make sure that the blue rubber sealing ring is in the correct final position Attach the longer patch cable for the T24 Info2wire info module 3 Feed the MxBus two wire cable from the camera installation as described in Section 2 4 1 together with the newly fitted patch cable into the housing and under the frame so that the MxBus cable can be fastened to the keypad board and the patch cable to the info module MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 Modules 4 First of all insert the right side of the module into the frame and then press firmly on the left side until the module audibly clicks into place Control click If you do not hear a click this means that the module is not properly locked into place In this case repeat the last steps making sure that no cable or foreign object in the housing is preventing the module from properly clicking into place MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 2 Installing The T24 KeypadRFID Please pay attention to the different system wiring configurations that apply described in Section 2 1 depending on whether or not the T24 DoorMaster and external devices such as a light are used 1 Ensure that the seal is fi
110. ry kept fully charged via MxBus at all times supplies power to the electric door opening mechanism even in the case of a power failure Outdoors Indoors The figure above the connection sections represents the number of cable w res Black YSTY 0 8 recommended or 0 6 mm D de d 4e SD 6 Orange Ethernet TD ED 9 Cat 5 or higher 2 09 VoIP videophone MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Overview Connection And Wiring Diagrams i 5 5 5 E 5 25 E amp 5 2 5 5 Ot m 5 d 5 5 E LO x o EM 5 2 d 5 2 gt zZ 5 m g 4 LO x o 5 WE x lt x lt Y EE lt 55 n BEES 5 E3 D Ges vo ge c 4 ME Z Meese SF lt 85 5 5 5 5 z 2 Z D 2 2 2 zZz 0008 8 Ajddns A zi pup 21e Jo 5 x E ar co E lt c MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 1 2 Without A T24 DoorMaster When a T24 DoorMaster is not used the electric door opener or Mediator including the door and door lock sens
111. sed for wireless communication for example as a key fob or a check card The device detects the incoming signal and automatically responds to it or forwards it The term transponder is made up of the terms transmitter and responder Passive transponders do not require their own power source but they only work over short distances UPS Uninterruptible Power Supply Refers to devices that temporarily continue to supply power in the event of a sudden power failure These devices usually operate using a battery UPS is installed on the power lines of devices and systems in order to protect them in the event of a power failure MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 146 148 148 USB Universal Serial Bus Plug and play interface between a computer and peripheral devices scanners printers etc Video Voice System The video voice system is usually able to capture outdoor areas visually The system has an intercom or duplex intercom option as well as an electrical door opening device The basic hardware consists of the door station exterior monitoring station interior and control center In the broadest sense it is an access control system that can be extended to include several door and or monitoring stations but always requires human intervention It is intended for use in visitor control predominantly for entrances and gateways in private areas and med
112. sk damaging the frame MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 5 Installing The T24 DoorMaster 2 5 1 Overview Of Connectors The T24 DoorMaster is connected to the door station via the MxBus two wire cable and the two wires of the anti theft protection cable In addition the four cables of the door signal contacts and the two cables of the electrically operated door opening components standard door opener Mediator can also be connected to the T24 DoorMaster see Section 1 2 Technical Specifications OUT 1 OUT OUT 2 IN MX IN 2 MX IN 1 The main function of this innovative device is to control the door opener in a tamper proof manner and record the status of the door open closed closed and locked The T24 DoorMaster with its speaker that can be switched off also functions as a doorbell furthermore allows the door to be opened using a button and controls the anti theft protection in the T24 housing Thanks to its built in batteries which are kept fully charged via the MxBus cables the T24 DoorMaster is able to power both the keypad in the outdoor station and a connected door opener for several hours in the case of power failure therefore ensuring that the door can still be accessed without a key MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales m
113. t Push the cavity socket into the prepared drill hole 68 mm in the cavity wall and secure it by tightening the clamp screws The metal claws automatically pop out and clamp the socket firmly B N After connecting the cables secure the housing and board directly to the cavity socket by fastening two small screws in the a and b positions see fig This requires that the socket is properly installed in the wall H nt Use a cavity Socket cutter counters nk hole cutter When the screws are tightened the metal claws automat call pop out and clamp the socket to the cavity wall made of wood or plasterboard for example As in the case of the in wall socket you can also use four or two screws screw anchors diagonally opposite one another to tightly screw the housing to the wall MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 DoorMaster 2 5 4 Installation Using Cavity Or In Wall Socket l Prepare all the required cabling and the cavity or in wall socket See previous sections 2 Remove the battery pack connect the connector A guide the cable under the battery pack and replace the battery pack B The red LED indicates that the battery is low 3 Screw on the MxBus cable coming from the 4 door station e Red wire to MX terminal e Blue wire to MX terminal When extending the MxBus cable make sure the polarity is c
114. tallation instructions are included in the Siedle Anti Theft Protection package MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 9 6 Connecting Securing And Removing Modules Connecting And Securing For detailed installation instructions for Siedle products see the documents provided by Siedle directly 1 Mount the Siedle installation frame Position the Siedle installation frame and snap it into place Ensure that the two wire cable with the MxBus push terminal is routed through and not jammed The MxBus cable must be secured to both of the MxBus terminals on the terminal board red wire to blue wire to For more information see the circuit overview diagram in the last section The MxBus cable must be secured to both of the MxBus terminals on the terminal board red wire to blue wire to a For more information see the circuit overview diagram in the last section 2 Connect cable Connect the camera patch cable to the RJA5 connector on the terminal board Connect the MxBus push terminal with the camera module Ensure that the camera patch cable is positioned under the middle bar of the brass installation frame 3 Mount the camera module Place the camera module onto the installation frame from above and snap into place MOBOTIX AG Security Vision Systems Made in Germany www mobo
115. tant features such as transfer hold and conference calling for use in a professional environment in addition to numerous multimedia functions The full duplex speaker phone is equipped with an acoustic echo canceller for noise suppression The integrated camera can be switched on or off at the touch of a button Additional multimedia features include a multimedia player for data from a USB stick or SD card display of RSS feeds and access to Internet radio The device also includes two Fast Ethernet connectors a USB port for external keyboards etc and an SD card slot so you can easily transfer and use your own data with the phone The integrated 2 5 mm connector allows you to attach a headset and the video images can be displayed on an external monitor using the A V jack In principle other IP video telephones with H 264 and G 711 can also be used as a T24 remote station Due to the technical specifications of a particular device display size audio functions etc however it cannot be guaranteed that all T24 remote station functions of the Grandstream GXV3140 are available MOBOTIX AG gt Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 1 3 2 MxEasy Video Management Software MOBOTIX provides the MxEasy software free of charge to configure and operate the T24 IP Video Door Station with a network enabled desktop or notebook computer
116. tems and equipment may only be set up changed and maintained by a qualified electrician or under the management and supervision of a qualified electrician in accordance with electrotechnical regulations MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 T24 Info2wire Indoor Unit An Mx2wire set always consists of two devices that communicate with one another For this reason the necessary unit to connect to the network and to supply power is included with the Mx2wire info module in the door station 80 mm LED orange data LED green power supply RJ45 network connection 80 mm SC 4 48 57 6 M optional a Two wire connection additional 24 Info2wire power supply B info module IOOSLS dO MESEM any MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Outdoor Station Technical Specifications T24 Info2wire Indoor Unit Data transfer rate Up to 50 Mbps net depending on distance Ethernet PoE Class 3 Mx2wire info module 48 57 V DC 600 Interfaces mA optional additional supply Certificates EMV EN55022 EN55024 EN61000 6 1 FCC part15B AS NZS3548 PoE PoE IEEE802 3af performance related 7 Watt Power supply own consumption or 48 57 V DC 600 mA SEL
117. terminal marked as b on the Siedle terminal connectors For modules for which the internal light is active the iLi signal must be connected to terminal b MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installation In The Siedle Vario System 13 3 148 Siedle Bell Button Module 1 To 4 Connect module terminals c and 6 bell button base voltage to c connect module 1 to 4 buttons terminal b to module iLi connect module terminals 7 1 to 7 4 to IO module 7 1 to 7 4 Module iLi b 2 gt 71 71 H 7 2 72 e 2 73 7 3 74 74 9 fl Siedle Fingerprint Module And Electronic Key Electronic Key Connection for both modules is identical Connect module terminal bv to b connect module terminals cv and 51 to c connect module terminal S2 to module Auth S2 Module Auth S2 S2 b h3 Y 0 o LI EJ MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 Siedle Motion Detector Module The module here is used as a motion sensor and no longer as an illumination sensor as the system uses the illumination sensor feature built into the camera Connect module term
118. tix com sales mobotix com Installation In The Siedle Vario System 4 Mount the Siedle modules Connect the modules with the associated terminal connector Place modules such as the camera module onto the installation frame from above Removing For detailed installation instructions for Siedle products see the documents provided by Siedle directly 1 Deactivating Siedle anti theft protection If the anti theft protection accessory has been installed it must first be switched off at the controller before the modules may be removed 2 Removing the camera module and Siedle modules Take the special key which was included with the Siedle installation frame Insert the key into the small opening between the modules and release the modules from the installation frame by pushing the key in MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 MOBOTIX Glossary 24 MOBOTIX GLOSSARY Bonjour Also known as Zeroconf network Bonjour enables automatic identification of computers devices and services in IP networks Bonjour also enables the automatic identification of devices among one another without the user having to enter IP addresses or configure the DNS server Bonjour was developed by Apple Computer Inc CCTV Abbreviation for Closed Circuit Television A television system in which the analog video signal is only transmitted to m
119. tted to the keypad Seal 2 Loosen the rear cover plate using a small screwdriver or similar tool and remove it You now have a clear view of the connectors located directly on the keypad board 3 Remove approximately 5 mm of insulation from each of the cables to be connected and feed each cable pax E through one of the wire apertures in the housing mo piercing the rubber membrane MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 Modules 8 5 148 4 Connect the two MxBus cables that come from the camera module to the keypad board e Red wire to MX terminal EE overv ew e Blue wire to MX terminal diagram on the next page 5 Connect two new MxBus cables to the keypad board and subsequently connect these to the info module to power its backlighting Make sure that the cables are of the required length and that they are routed correctly does not apply to T24 Info2wire info module e Red wire MX terminal e Blue wire MX terminal Do not swap the polarity of the and MxBus wires If the info module is connected to the MxBus connector of the door camera T24 E CamCore the two MxBus cables of the T24 DoorMaster can be connected to the a keypad instead gt lt 4 no lighting function is required for the info module at all the MxBus cables do not need to be connected to this
120. tton x Transformer signal 6 Module Door opener 136 148 Board 7 4 7 3 7 2 7 1 ERT optional Board eLi c Board Do Installation In The Siedle Vario System 137 148 Door Contact And Door Lock Switch Connect both with one connection each to c connect the second connector of the door contact to IO module Dpc Door Position Contact connect the second connector of the Serre Module door lock switch to module Bpc Bolt Position Contact Door contact Dpc Door contact Board Door lock switch 0 000006 0 TEE The contacts can generally also be installed in existing doors To do so use a long drill bit to drill a conduit in the door frame leading directly to an in wall socket on the wall facing the door inside the building then lay a cable from here to the door station Siedle Anti Theft Protection The separately available Siedle Anti Theft Protection module DSC 602 0 with ZDS 601 0 provides additional protection by electromagnetically locking the installation frame so that the individual modules can no longer be mechanically removed using the supplied Siedle key from the door station The lock ZDS 601 0 mounted in the installation frame is connected to the associated controller DSC 602 0 in the electrical cabinet Anti theft protection can only be activated or deactivated using this controller Ins
121. two way video communication e Connection via Ethernet WLAN 7T24 DoorMasfter Door contact er Open door doorbell on off 4 e Status LEDs for door messages Door opener M AD e Backup power supply with battery S E 4 Connection of door opener and sensors Door lock switch T24 Info2wire4 Indoor Unit e Remote station for unit in the info module e Data transfer and power supply via two wire connection e Alternative to standard Ethernet cable e Power input with PoE switch or 48 57 V DC 600 mA power supply unit Nefwork connection Connection to switch router PoE switch PoE with Mx2wire Network connection Connection to switch router Internet connection Worldwide access VoIP video phone ground floor remote station Two way video communication open door turn light on off e Operate camera including image correction e Monitor door status open closed locked e Recording and event search e Voice mailbox player MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 System Overview 24 1 SYSTEM OVERVIEW 11 Outdoor Station 111 Hemispheric Camera T24 CamCore The hemispheric camera with its fisheye lens for a 360 panorama view and integrated live image correction boasts a high resolution 3 1 megapixel color sensor or megapixel black and white sensor speaker microphone and 4 GB dat
122. ty Vision Systems Made in Germany www mobotix com sales mobotix com 8 Installing The Indoor Unit T24 Info2wire 2 6 5 Function Of Mx2wire Status LEDs Each Mx2wire unit has two status LEDs green and orange which provide information on the current state of the PoE power supply and on the transfer of data The LEDs can either light up continuously ON or they can blink BLINK T24 Info2wire indoor unit Two wire cable Data and power ON Network connection to the switch has been established BLINK Data is transferred from the indoor unit Green LED Orange LED ON Power is supplied to the indoor unit BLINK Outdoor station is receiving power is connected Orange LED ON Network connection to the outdoor station has been established BLINK Data is transferred to the outdoor station Green LED ON Power is supplied to the outdoor station BLINK never The two status LEDs orange green in the outdoor station s T24 Info2wire info module are only active for test purposes for the first 15 minutes after the power supply has been established After the LEDs have gone out they can be reactivated by interrupting the power supply for a short time MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 7 Connecting External Devices To The Doo
123. using and board from the panel and frame Loosen V sos Se A ihe screw in the front panel and lift the panel forwards Now remove the attached frame from the board Please note that you will need the stainless steel screw in the front panel again later 9 Insert the housing and circuit board into the socket The two cable clamps on the rear of the housing are located at the top When using a cavity socket make sure you only use the stainless steel screws provided Using different larger screws could damage the board Caution Electrical systems and equipment may only be set up changed and maintained by a qualified electrician or under the management and supervision of a qualified electrician in accordance with electrotechnical regulations MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 105 148 Select the type of frame requ red When a battery is almost completely discharged a functional test can only be carried out after the red LED has gone out after approx mately 15 minutes Installing The T24 DoorMaster 10 Attach the frame Place the selected frame concave convex or flat onto the board and press down gently until it automatically snaps into place MOBOTIX is printed on the bottom of the frame Insert panel Hook the front panel onto the bottom of the frame as shown in the figure and then press it down 12 Screw the p
124. w in the front panel and liftthe panel forwards Now remove the attached frame from the circuit board Please note that you will need the stainless steel screw in the front panel again later MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 4 Screw the two wire cable to terminals 1 and 2 The cable does not necessarily need to be attached to the terminal with the same number on both T24 Info2wire units The device continues to function if connectors 1 and 2 are swapped Connectors 3 and 4 are only assigned if an external voltage source 48 V DC is used 5 Insert the housing and circuit board into the surface mounted socket The two cable clamps on the rear of the housing are located at the top Attach the housing and board to the surface mounted socket by fastening the four stainless steel screws in the four existing drill holes 6 Attach the frame Place the selected frame concave convex or flat onto the board and press down gently until it automatically snaps into place MOBOTIX is printed on the bottom of the frame 7 Insert the panel Hook the front panel onto the frame as shown in the figure and then press it down First hook panel on underneath then press down the top 8 Screw the panel on tightly Secure the front panel using the panel s stainless steel screw MOBOTIX AG Securi
125. y locked This is signaled by a blue LED in configuration mode Configuration is required here see below LED green red LED blue 0 Doorbell Door opener and emergency unlocking in the event of a power failure MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com 12 Z2 4 Self powered standard v il SE Q as o em Mediator Finishing The Installation The signal output option is set on the T24 DoorMaster in three steps as part of system startup Step 1 Press both buttons at the same time for 5 seconds until double beep You are now in administration mode red LED turns off shortly every 3 seconds gt fe ae Step 2 Press door opener button right to configure the signal output option You can switch between signal output options 1 to 3 by pressing the right button repeatedly The flashing pattern of the blue LED signals the currently selected setting e Blue flashing 1x every 3 seconds Self powered e Blue flashing 2x every 3 seconds Relay e Blue flashing 3x every 3 seconds Mediator ere EE 0 Ld Je m m Step 3 Press both buttons at the same time for 5 seconds until double beep The setting has been saved and you are exiting administration mode Test that the T24 DoorMaster is functioning by pressing and holding the door opener button for 3 seconds It should now be possi
126. y locked into place In this case repeat the last steps making sure that no cable or foreign object in the housing is preventing the module from properly clicking into place Do not activate the anti theft protection lock until you have checked the wiring see Section 2 8 1 Also test the functionality of the anti theft protection see Section 2 4 6 MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com System Manual Part 1 Installation 24 2 4 3 Installing The Info Module T24 Info The info field in the info module of the T24 door station without Mx2wire technology is equipped with permanent LED backlighting supplied via MxBus 1 Ensure that the seal is fitted to the info module Seal 2 Loosentherear cover plate using a small screwdriver or similar tool and remove it You now have a clear view of the connectors located directly on the info module board 3 Remove approximately 5 mm of insulation from each of the cables to be connected and feed each cable 1255 L rar through one of the wire apertures in the housing piercing the rubber membrane with the cable MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Installing The T24 Modules 4 Connect the two MxBus cables that come from the keypad to the info module board e Red wire to MX terminal e Blue wire to MX terminal 5 Put the
127. your selected connection option for example to the T24 DoorMaster you may also need to extend the cable When you attach the frame make sure that the two openings for the special MOBOTIX key which is used to remove the door station modules are located either on the bottom left vertical mount or on the bottom right horizontal mount and that the maximum torque for the frame screws is not exceeded On Wall Fig Triple Housing Screw 8x marked red max 100 Ncm TT 12 mm Guide anti theft protection cable for T24 DoorMaster directly or extend with the two individual wire connectors Insert wire not stripped 1 and press down cutting clamp with pliers 2 Note slot for key MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Mounting The Frame And Housing 77 148 Cavity And In Wall Fig Triple Housing Please note that in this case the module frame may only be screwed onto the four outermost positions on the housing max torque 40 Ncm Screw 4x marked red max 40 Ncm TT 30 mm NOT USABLE Frame alignment for vertical and horizontal mounting Guide anti theft red arrow points protection cable to to the keyhole the T24 DoorMaster directly or extend with the two individual wire connectors Ry 2 Insert wire not stripped 1 and press down cutting clamp ae o
128. ys View with housing cover removed Sealing plug Seal MxBus terminal 7 ncn tie FE C X com moo gt 99 mm e IO terminal MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com Additional MOBOTIX Keyless access using RFID card and PIN MxBus RFID 13 56 MHz Mifare DESFire EVI illuminated keys acoustic feedback 2 galvanically separated inputs AC DC self powered up to 50 V 1 isolated relay output AC DC 50 V 60 W 2 Illumination sensor IP65 DIN EN 60529 30 C to 50 C 22 F to 122 F DIN EN 50125 MxBus typically 1 W 99 mm x 99 mm min 0 14 mm max 0 5 mm min 0 2 mm max 0 5 mm min 0 25 mm max 0 5 mm n 24 max 20 m n 26 max 20 m Technical Specifications T24 KeypadRFID Technical Specifications Terminals Used On The Keypad Outdoor Station Functions Interface User interfaces Inputs Outputs Sensors Protection class Operating temperature Power supply Power consumption Dimensions W x H Cable cross section fixed Cable cross section flexible Cable cross section flexible with wire end sleeves without plastic sleeves Cable cross section AWG kcmil AWG according to UL CUL MOBOTIX AG Security Vision Systems Made in Germany www mobotix com sales mobotix com