1. Tripp Lite 1111 W 35th Street J Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 208 120V or 240 120V 16kVA 14 4kW Highlights On Line Double Conversion UPS N 1 Extended ues pian Sate Run SNMP Webcard 14U Rack Tower USB DB9 spate ss yaa amiga i 0 9 power factor Se rial e 208 120V or 240 120V 60Hz MODEL NUMBER SU16KRT 1TF Sy aa a i Economy mode option e Hot swap power and battery modules N 1 fault tolerance at loads up to 8kVA e USB RS232 amp EPO ports support for SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire L6 30R C19 5 15 20R amp 5 15R outlets Description Tripp Lite SU16KRT 1TF 16 000VA 16kVA 14 400 watt online double conversion UPS system offers complete power protection for critical server network and telecommunications equipment in a 14U rack tower Package Includes e Two SU8000RT3UPM UPS power modules e Two BP240V10RT3U battery packs e One SU6000XFMR2U 208 240V to 120V transformer e SUPDMB20K parallel PDU with Bypass switch configuration This system delivers complete N 1 redundancy when used at loads up to 8kVA and non redundant operation at loads between 8 and 16kVA Fault tolerant auto bypass prevents unexpected service interruptions during UPS overload or internal fault conditions Included parall
2. cluded 2U 3U module Installation Form Factors Supported 2 post rackmount 22OSTRMKITHD Tower 2 9USTAND with Optional Accessories Optional Mounting Accessory Notes Qty 52POSTRMKITHD required for 2 post rackmount installation Qty 2 2 9USTAND required for tower installation UPS Power Module Dimensions 5 14 x 17 5 x 25 82 hwd in UPS Power Module Dimensions 13 1 x 44 5 x 65 6 hwd cm Installed Whole System Maximum 395 Rack Depth in Installed Whole System Maximum 82 6 Rack Depth cm UPS Dinen on Daai Includes 2 SU8000RT3UPM UPS Power modules and 2 BP240V10RT3U Battery packs Listed weights and dimensions for UPS Power module and Included battery pack each refer to a single unit Stepdown Transformer Dimensions 35x17 5x 218 hwd in Stepdown Transformer Dimensions 889x444x554 hwd cm Included Battery Pack Dimensions 5 25x 17 5x25 hwd in Included Battery Pack Dimensions 13 3 x 44 5 x 63 5 hwd cm Included Battery Pack Weight Ibs 158 7 UPS Shipping Dimensions hwd in 36 x 40 25 x 51 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS Shipping Dimensions hwd 91 4 x 102 2 x 129 5 cm Shipping Weight Ibs O N N Shipping Weight kg 307 4 Cooling Method Fans UPS Housing Material Steel ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Stora
3. eet amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Cold Start Startup in Battery Mode i During a Power Failure Cold start operation supported Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of Economy Mode Operation 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries Green Energy Saving Features eaa mode operation Support for daily startup and shutoff Schedulable daily hours of economy CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance oa U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement High Availability UPS Features Specifications are subject to change without notice Photos may differ slightly from final products 6 6
4. el PDU with manual bypass switching enables hot swappable replacement of all major UPS system components in both N 1 and combined operating modes Enhanced availability fault tolerance and simple hot swap replacement options make this UPS ideal for advanced networking applications in data centers computer rooms network closets and rugged industrial locations e 4 post rackmount installation rails e PowerAlert software and cabling Features e Tripp Lite SU16KRT 16kVA 16 000VA 14 400 watt on line double conversion UPS system in 14U total rack tower configuration e Unique configuration offers 16kVA non redundant operation and automatic N 1 redundancy at load levels of 8kVA and under e Included Parallel PDU with manual bypass switch enables hot swap replacement of power modules at any supported load level e Hardwire input 2 L6 30R 208 240v 8 C19 208 240v 8 5 15 20R 120v and 4 5 15R 120v outlets e Maintains full time sine wave output within 2 of selectable 200 208 220 230 240V amp 120V nominal e Expandable runtime with optional external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Battery independent restart e Highly efficient economy mode option e Optional SNMPWEBCARD RELAYIOCARD and RELAYIOMINI interface modules available RELAYIOMINI requires removal of USB interface module e Applications utilizing the optional network communications card
5. former module is set to match the 208 or 240V power module setting Frequency Compatibility Details Output frequency regulation 0 05Hz free running Output Voltage Regulation Line 2 Mode Output Voltage Regulation 10 Economy Line Mode Output Voltage Regulation Battery 2 Mode Output Receptacles 4 5 15R 8 5 15 20R 2 L6 30R 8 C19 Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input Additional 120V capacity is available by adding a second SU6000XFMR2U step down transformer Output Receptacle Details 2 6 Tripp Lite 1111 W 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com POWER MODULE Two built in 30A breakers protect one L6 30R outlet each Eight built in 20A breakers protect Output Circuit Breakers one C19 outlet each TRANSFORMER MODULE Two 15A breakers protect 2 5 15R outlets each Two 20A breakers protect 4 5 15 20R outlets each INPUT Recommended Electrical Service 100A 208V or 240V L1 L2 G Input Phase Single Phase BATTERY Expandable Runtime Description For best results add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs Battery Recharge Rate Included Batteries Battery Replacement Description Hot swappable user replaceable external battery packs VOLTAGE REGULATION Voltage Regulation Description 2
6. ge Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 5456 AC Economy Mode BTU Hr Full Load AC Mode Efficiency Rating 100 90 Load AC Economy Mode Efficiency Rating 96 100 Load Operating Elevation ft 0 3000m 0 to 10 000 ft Audible Noise 60 dBA at front side 1 meter 2046 Operating Elevation m 0 3000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Applications utilizing the optional network communications card require two SNMPWEBCARD accessories install Network Monitoring Port Description one per included power module Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports PowerAlert Software Included Communications Cable USB DB9 serial and EPO cables included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8 milliseconds typical power failure response in optional economy mode Low Voltage Transfer to Battery 100V Power Setpoint High Voltage Transfer to Battery 300V Power Setpoint SPECIAL FEATURES Tripp Lite 1111 W 35th Str
7. output voltage regulation in standard online double conversion mode Overvoltage Correction Corrects overvoltages up to 300V Undervoltage Correction Corrects undervoltages as low as 100V USER INTERFACE ALERTS amp CONTROLS Less than 6 hours from 10 to 90 typical full load discharge Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options Front Panel LCD Display LED LCD panel rotates for viewing in rack tower formats LCD Display supports ENGLISH FRENCH GERMAN ITALIAN SPANISH and PORTUGUESE see manual 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and Switches execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 3 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com FED indicas 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options SURGE NOISE SUPPRESSION UPS AC Suppression Response Instantaneous Time EMI RFI AC Noise Suppression Yes PHYSICAL ea Pea 5 sets of adjustable 4 post rack rails included one for each in
8. require two SNMPWEBCARD accessories install one per included power module 1 6 Tripp Lite 1111 W 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e HID compliant USB interface e Includes Free PowerAlert monitoring software PowerAlert LOCAL PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 6 required e Optional 2 9USTAND supports upright tower placement 2 required e Supports Emergency Power Off EPO via built in interface e Front panel LEDs and LCD readout with scroll controls e LED LCD display panel rotates for viewing in rackmount or tower configurations e External battery packs are field replaceable and hot swappable Specifications General Info OUTPUT Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Output Capacity Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less a Nominal Output Voltage s 120V 208V 240V Supported This configuration requires the Power Module be set to 208 or 240V output voltage included step down transformer Nominal Voltage Details supports 120V output when the voltage selection switch on the trans