Home
Dyson AM02 fan
Contents
1. on its own centre of gravity staying put without clamping Airflow control Oscillation control Dimmer switch control Independent motor drives Precisely adjusts smooth 90 oscillation airflow power Air Multiplier technology eS Remote control dyson A jet draws in surrounding air amplifying it 16 times On off control No blades No buffeting High speed jet Loop amplifier Variable airflow control Push button to quickly adjust airflow power Oscillation control Independent motor eer drives smooth oscillation Surrounding air drawn into airflow Magnetic location m A Variable 7 airfoil shaped ramp Curved and magnetised f Y er TH airflow control Generates maximum airflow to store neatly on velocity and volume the machine a F Safe i No fast spinning blades an Easy to clean No awkward grilles or blades Safe lis aperture Air is forced out to create the jet Easy to assemble No tools required ar a 13mm airflow projector hag i i Directs more air towards you by focusing its exit angle Air inlet pay j 7 Mixed flow impeller 4 Up to 33 litres of 1 j T A combination of the technologies de a air drawn in per Easy to clean Y F used in turbochargers and jet second generating oy engines generates powerful airflow primary airflow 1007mm gt z Brushless motor Low centre of gravity Id Energy efficient Variable Heaviest compo
2. dyson James Dyson Blades cause buffeting The blades on conventional fans cause unpleasant buffeting because they chop the air before it hits you No blades No buffeting Air Multiplier technology amplifies surrounding air giving an uninterrupted stream of smooth air Fast spinning blades Conventional fans have fast spinning blades that have to be guarded by a safety grille Safe The Dyson Air Multiplier fan has no blades It s safe Awkward to clean Conventional fans are complicated to dismantle and clean Easy to clean The Dyson Air Multiplier fan has no awkward grilles or blades Limited settings Conventional fans only have 3 or 4 settings and one of those is off You wish you could adjust it a little Dimmer switch The Dyson Air Multiplier fan has dimmer switch control to precisely adjust airflow power Awkward to adjust Conventional fans are top heavy and awkward to adjust Touch tilt The Dyson Air Multiplier fan pivots on its own centre of gravity staying put without clamping How it works Airfoil shaped ramp Entrained air ve ur Air Multiplier technology Air is accelerated through an annular aperture This creates a jet of air that passes over an airfoil shaped ramp channelling its direction Surrounding air is drawn into the airflow amplifying it 15 times this is called inducement and
3. entrainment Inside out Dyson engineers always start with the core problem then work outwards So our machines look the way they look because of how they work One engineer had the original idea But it took every discipline from Dyson s 650 strong team of engineers and scientists to develop Air Multiplier technology Design engineers electrical engineers fluid dynamics technicians prototype engineers test engineers software engineers motor engineers microbiologists mechanical engineers dyson No blades No buffeting Mixed flow impeller A combination of the technologies used in turbochargers and et engines generates powerful airflow Brushless motor Energy efficient Variable power rather than the limited settings on conventional motors Air inlet Up to 27 litres of air drawn in per second generating primary airflow Easy to assemble Just push fit loop amplifier to base then twist On off control LED for use in the dark 16 airfoil shaped ramp Generates maximum airflow velocity and volume Safe No fast spinning blades Easy to clean No awkward grilles or blades 1 3mm annular aperture Air is forced out to create the annular jet 10mm airflow projector Directs more air towards you by focusing its exit angle Pie amp y Low centre of gravity Base mounted motor Not top heavy and unstable like conventional fans i Touch tilt Pivots
4. nents id power rather than the positioned low down limited settings on for improved stability conventional motors Variable Air Multiplier technology Remote control dyson airflow control A jet draws in surrounding air amplifying it 18 times i On off control No blades No buffeting SED amplifier Variable airflow control Push button to quickly adjust airflow power om Safe Oscillation control High speed jet Fe IN Safe Independent motor a No fast spinning blades drives smooth oscillation Easy to clean Magnetic location 7 airfoil shaped ramp No awkward grilles Curved and magnetised f f A to store neatly on Generates maximum airflow or blades 4 yo velocity and volume the machine Easy to clean E gt Easy to assemble No tools required T T l Easy to tilt an eas ON projector Stays put without clamping Directs more air towards 1mm annular aperture you by focusing its j Air is forced out to create exit angle l Easy height adjust ge the annular jet i Mixed flow impeller A combination of the Easy height adjust technologi i l Tee B The stand uses a constant force ne ek tensator spring to resist the Ie ee u force of gravity So it stays ea put without clamping ge Brushless motor Easy to tilt Energy efficient Variable power a rather than the limited settings a on conventional motors Ei em io Low centre of gravity 1408mm Air inlet Heaviest comp
5. onents Up to 33 litres of air drawn in per positioned low down for second generating primary airflow improved stability dyson air multiplier No blades No buffeting Blades cause buffeting Guaranteed for 2 years Parts and labour For advice and support call Dyson experts 7am 10pm 7 days a week UK 0800 298 0298 ROI 01 475 7109 Learn more at www dyson co uk See reviews at www dysonairmultiplier com No blades No buffeting JN 35513 17 06 10
Download Pdf Manuals
Related Search
Related Contents
Meet Our Student Workers Controller GE AEE12 User's Manual Operating Instructions Fujitsu LIFEBOOK AH552 A Guide to Biosafety & Biological Safety Cabinets FR - Intex Clicca e scarica il manuale relativo al prodotto selezionato LBT-ESP01_UM_2_OL Krachtbediende klauwplaat Type ROTA THWplus Mandrin Maestro Administrators Manual - L Copyright © All rights reserved.
Failed to retrieve file