Tripp Lite SmartOnline 208/120V or 240/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, LCD, USB, DB9 Serial
Contents
1. Economy Line Mode Output Voltage Regulation Battery 4 50 Mode Output Receptacles 4 5 15R 8 5 15 20R 1 L6 30R Hardwire Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot swappable power module replacement Output Circuit Breakers Low voltage 20A breakers on the transformer module protect 4 5 15 20R outlets each Low voltage 15A breakers protect 2 5 15 20R outlets each INPUT Input Phase Single Phase Output Receptacle Details 3 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com BATTERY Full Load Runtime min 2 minutes 5400 watts Half Load Runtime min 8 5 minutes 2700 watts Expandable Battery Runtime Runtime is expandable with external battery packs BP192V1037C 1PH BP192V12 3U BP192V1407C 1PH BP192V557C 1PH BP192V787C 1PH BP192V5RT2U limit 1 Battery Recharge Rate Included 6 hours from 10 to 90 typical full load discharge Batteries Internal UPS Replacement Battery RBC5 192 Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable user replaceable internal batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Overvoltage Correction Corrects overvoltages as high as 300V lt 90 load and 280V full load Undervoltage Correction Corrects undervoltages as low as 100 l
2. e Supports Emergency Power Off EPO via built in interface e Battery independent restart ensures automatic UPS power up without userinteraction after lengthy power outages even when batteries areexpired and require replacement e BP192V12 3U external battery packs are field replaceable and hot swappable e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only Specifications 2 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com OUTPUT Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Output Capacity Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as the overload is cleared a Nominal Output Voltage s 120V 208V 240V Supported This configuration requires the Power Module be set to 208 or 240V output voltage included step down transformer Nominal Voltage Details supports 120V output when the voltage selection switch on the transformer module is set to match the 208 or 240V power module setting Frequency Compatibility Details Output frequency regulation 0 05Hz free running Output Voltage Regulation Line 2 Mode Output Voltage Regulation 10
3. TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 208 120V or 240 120V 6kVA 5 4kW On Line Double Conversion UPS Extended Run SNMP Webcard 6U Rack Tower LCD USB DB9 Serial MODEL NUMBER SU6000RT4UTFHW Description Tripp Lite SU6OOORT4UTFHW 6000VA 6kVA 5400 watt on line double conversion UPS system offers complete power protection for critical server network and telecommunications equipment in a 6U rack tower compatible configuration Full time active power conditioning provides clean continuous dual conversion AC output free of voltage fluctuations power interruptions and line noise Fault tolerant auto bypass prevents unexpected service interruptions during UPS overload or internal fault conditions Detachable back panel PDU with manual bypass switch supports hot swappable UPS power module replacement with no interruption to connected equipment 4U UPS power module and included 2U low voltage transformer install in only 6 rack spaces total 6U with a maximum installed depth of only 21 8 in 55 3 cm Maintains full time sine wave output within 2 of selectable 208 240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V Expandable runtime is supported with optional BP192V12 3U external battery packs Battery independent restart ensures automatic UPS power up without userinteraction after lengthy power outag
4. es even when batteries are expired and require replacement Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types Highlights e 6kVA 6000VA 5400W on line double conversion UPS 0 9 power factor e 208 120V or 240 120V 60Hz output Economy mode option e 6U Rack Tower installation Hot swappable power and battery modules e USB RS232 amp EPO ports SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire NEMA 5 15R 5 15 20R amp Hardwire outputs Package Includes e SU6000RT4UHVPM Hot swappable UPS Power Module SUPDMB6KHW Detachable PDU with Maintenance Bypass Switch e SU6000XFMR2U Low voltage transformer e PowerAlert Software CD e 1x6 ft USB Cable e 1x 6 ft Serial Cable e 4 Post Rackmount Hardware 2 sets Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs Network grade AC surge and noise suppression Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 and USB interfaces Optional SNMP Web and contact closure communica
5. nversion AC output free of voltage fluctuations power interruptions and line noise e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Detachable back panel PDU contains input line cord connection output receptacles and manual bypass switch to support hot swappable whole UPS replacement with no interruption to connected equipment e Hardwire input 208 240V L1 L2 G e Hardwire high and low voltage output plus 8 5 15 20R and 4 5 15R 120V outlets e Included rail kit supports 4U 19 inch rackmount installation in 4 post racks e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 2 required for SU6N0D0DRT4UTFHW e Optional 2 9USTAND supports upright tower placement 1 required for SUGOOORT4UTFHW e Maximum installed rack depth of only 21 8 in 55 3 cm e Maintains full time sine wave output within 2 of selected 208 240V and 120V nominal at 60Hz in double conversion mode e Corrects brownouts to 156V at full load 100V at 50 load or less e Corrects overvoltages to 290V at full load 300V at 90 load or less e Double conversion operation offers full time AC to DC then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types e High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating ene
6. ower Module Dimensions 6 85 x 17 5 x 20 7 hwd in UPS Power Module Dimensions 17 4 x 44 5 x 52 6 hwd cm Installed Whole System Maximum 21 8 Rack Depth in i Installed Whole System Maximum 55 4 Rack Depth cm f Rack Height U Spaces UPS Power Module Weight Ibs 116 2 Stepdown Transformer Dimensions 3 5 x 17 5 x 21 8 hwd in Stepdown Transformer Dimensions 8 8 x 44 5 x 55 4 hwd cm i UPS Shipping Dimensions hwd in 22 2 x 23 6 x 29 1 UPS Shipping Dimensions hwd 56 4 x 59 9 x 73 9 cm ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 1767 AC Economy Mode BTU Hr Full 765 Load AC Mode Efficiency Rating 100 90 Load AC Economy Mode Efficiency Rating 96 100 Load 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Operating Elevation ft 0 3000m 0 to 10 000 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8ms
7. rgy costs e Network grade AC surge and noise suppression e Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 USB and optional SNMP card slot interfaces e UPS card slot supports one card based network interface option part SNMPWEBCARD or dry contact monitoring accessory part RELAYIOCARD e Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces e Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification e Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Includes Free PowerAlert monitoring software packages PowerAlert LOCAL for desktops and small business networks PowerAlert NSA Network Shutdown Agent for larger networks and PowerAlert NMS Network Management System for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Front panel LEDs and LCD readout with scroll controls support front panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations e LED LCD display panel rotates for viewing in rackmount or tower configurations
8. t 50 load and 155V full load derates linearly USER INTERFACE ALERTS amp CONTROLS Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options Front Rane ECO Display LED LCD panel rotates for viewing in rack tower formats see manual External Battery Pack Compatibility Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions A manual bypass Switches switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD LED Indicators i 5 i screen offers additional information and control options SURGE NOISE SUPPRESSION Time PHYSICAL Included Mounting Accessory Description 4 post rackmount installation accessories included 2 sets 4 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Installation Form Factors Supported 2 Post rackmount 2POSTRMKITHD Tower 2 9USTAND with Optional Accessories Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate UPS and transformer components UPS P
9. tions card accessories available HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto shutdown of connected systems as UPS batteries become depleted Included software packages include PowerAlert Local PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types Supports Emergency Power Off EPO via built in interface Front panel LEDs and LCD readout with scroll controls support front panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations LED LCD display panel rotates for viewing in rackmount or tower configurations Hardwire input Hardwire UPS output plus 1 L6 30R 8 5 15 20R and 4 5 15R outlets External battery packs are field replaceable and hot swappable 250 000 1 6 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Ultimate Lifetime Insurance U S Canada and Puerto Rico only Features e Tripp Lite SUGOOORT4UTFHW 6000VA 6kVA 5400 watt on line double conversion UPS system in a 6U rack tower compatible configuration 4U power module plus 2U low voltage transformer e Full time active power conditioning maintains clean continuous dual co
10. typical power failure response in optional economy mode Low Voltage Transfer to Battery 156V full load 100V 50 load or less derates linearly Power Setpoint High Voltage Transfer to Battery 280V full load 300V 90 load or less Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries Green Energy Saving Features High efficiency economy mode operation Support for daily startup and shutoff Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance A U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6