1. Installed Whole System Maximum 52 6 Rack Depth cm UPS Shipping Dimensions hwd 32 3 x 59 9 x 73 9 cm ENVIRONMENTAL AC Economy Mode BTU Hr Full 707 Load AC Mode Efficiency Rating 100 90 Load AC Economy Mode Efficiency Rating 96 100 Load Operating Elevation ft 0 3000m 0 to 10 000 ft 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8 ms typical power failure response in optional economy mode Low Voltage Transfer to Battery 156V full load 100V 50 load or less derates linearly Power Setpoint High Voltage Transfer to Battery 280V full load 300V 90 load or less Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode bs During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries Green Energy Saving Features High efficiency economy mode operation Support for daily startup and shutoff Schedulable daily hours of econom
2. as low as 100 lt 50 load and 155V full load derates linearly USER INTERFACE ALERTS amp CONTROLS Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options Front Panel LCD Display LED LCD panel rotates for viewing in rack tower formats see manual Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions A manual bypass Switches switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD LED Indicators ais screen offers additional information and control options SURGE NOISE SUPPRESSION 4 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Time PHYSICAL Included Mounting Accessory Includes 4 post rackmount installation accessories Description Installation Form Factors Supported 2 post rackmount 22OSTRMKITHD Tower 2 9USTAND with Optional Accessories UPS Power Module Dimensions 6 85 x 17 5 x 20 7 hwd in i UPS Power Module Dimensions 17 4 x 44 5 x 52 6 hwd cm Installed Whole System Maximum 20 7 Rack Depth in
3. without user interaction after lengthy power outages even when batteries are expired and require replacement e BP192V12 3U external battery packs are field replaceable and hot swappable e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Frequency conversion mode enables conversion of 60Hz to 50Hz or 60Hz to 50Hz no de rating Specifications OUTPUT Output capacity de rates to 4992 watts when used at 208V nominal Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as the overload is cleared Output Volt Amp Capacity VA 6000 Output kVA Capacity kVA Output Watt Capacity Watts 5400 Output Capacity Details Output kW Capacity kW 5 4 3 1 Crest Factor Nominal Output Voltage s 200V 208V 240V Supported Nominal Voltage Details Voltage selection via front panel LCD interface Frequency Compatibility 50 60 Hz Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating Output Voltage Regulation Line 41 2 Mode Output Voltage Regulation JEN Economy Line Mode 10 Output Voltage Regulation Battery 2 Mode Output Receptacles 2 L6 20
4. R 2 L6 30R Frequency Compatibility Details Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot swappable power module replacement Output Receptacle Details Output Circuit Breakers 20A breaker protects L6 20R outlets L6 30R outlets are unbreakered INPUT Rated input current Maximum Load 31 9A 200V 30 6A 208V 29A 220V 27 7A 230V 26 6A 240V Nominal Input Voltage s Supported 200V AC 208V AC 240V AC 3 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com BATTERY Full Load Runtime min 2 minutes 5400 watts Half Load Runtime min 8 5 minutes 2700 watts Expandable Battery Runtime Runtime is expandable with external battery packs BP192V1037C 1PH BP192V12 3U BP192V1407C 1PH BP192V557C 1PH BP192V787C 1PH BP192V5RT2U limit 1 External Battery Pack Compatibility Battery Recharge Rate Included 6 hours from 10 to 90 typical full load discharge Batteries Internal UPS Replacement Battery RBC5 192 Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable user replaceable internal batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Overvoltage Correction Corrects overvoltages as high as 300V lt 90 load and 280V full load Undervoltage Correction Corrects undervoltages
5. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com TRIPP LITE SmartOnline 200 240V 6kVA 5 4kW On Line Highlights Double Conversion UPS Extended Run SNMP eres pein Dae Webcard 4U Rack Tower USB DBI Serial Bypass ot swappable no service ca Switch MODEL NUMBER SU6000RT4UHV or technician needed e Included maintenance bypass switch enables live replacement of UPS with zero downtime e Protects rackmount servers telecom systems and other networking equipment in high voltage environments with true on line operation pure sine wave output and zero transfer time e 4AC outlets 2 L6 20R 2 L6 30R with 200 208 220 230 240V 50 60Hz output e 6kVA 5400W capacity in 4U form factor with power module and independent detachable PDU e Hot swappable power and Description Featuring true on line operation with pure sine wave output zero transfer time to battery and complete UPS replacement capability with no downtime the SUBN00RT4UHV provides the highest level of protection available paliely modules for mission critical equipment from power outages voltage fluctuations and transient surges It converts o Seen ime sac uslec el laa incoming AC power to DC and re converts it back to filtered AC output with a pure sine wave isolating ainat expandable connected components from all power problems in high voltage environments The SU6000RT4UHV has a runtime wil
6. nada and Puerto Rico only 2 year warranty Package Includes e SU6000RT4UHVPM Power Module e SUPDMB6K Detachable PDU with Maintenance Bypass Switch e PowerAlert software and Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com The SUG000RT4UHV features a USB port and a DB9 port that when used with Tripp Lite s included PowerAlert software provide comprehensive network power monitoring and control An optional SNUPWEBCARD complete cabling e 4 post rackmount installation accessory can enable the UPS to operate as an IP managed device hardware The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2 post rack using the 2POSTRMKITHD accessory or in a tower configuration with the 2 9USTAND accessory The SU6000RT4UHV comes with 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only for connected equipment and a 2 year warranty Features e Tripp Lite SUGOOORT4UHV 6000VA 6kVA 5400 watt online double conversion UPS system in a single 4U rack tower compatible housing at 208V nominal output is limited to 4992 watts e Full time active power conditioning maintains clean continuous dual conversion AC output free of voltage fluctuations power interruptions and line noise e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Detachable back panel PDU contains input line c
7. ord connection and output receptacles plus manual bypass switch to support hot swappable whole UPS replacement with no interruption to connected equipment e L6 30P input plug two L6 30R and two L6 20R outlets e Included rail kit supports 4U 19 inch rackmount installation in 4 post racks e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 1 required for SU6000RT4UHV e Optional 2 9USTAND supports upright tower placement 1 required for SU6N0D0RT4UHV e Maximum installed rack depth of only 20 7 in 52 6cm e Maintains full time sine wave output within 2 of selected 200 208 220 230 240V nominal in double conversion mode e Corrects brownouts to 156V at full load 100V at 50 load or less e Corrects overvoltages to 290V at full load 300V at 90 load or less e Supports 50 60Hz operation for worldwide frequency compatibility e Double conversion operation offers full time AC to DC then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types e High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs e Network grade AC surge and noise suppression e Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 USB and optional SNMP card slot interfaces e UPS card sl
8. ot supports one card based network interface option part SNMPWEBCARD or dry contact monitoring accessory part RELAYIOCARD e Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces e Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification e Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Includes Free PowerAlert monitoring software packages PowerAlert LOCAL for desktops and small business networks PowerAlert NSA Network Shutdown Agent for larger networks and PowerAlert NMS Network Management System for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Front panel LEDs and LCD readout with scroll controls support front panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations e LED LCD display panel rotates for viewing in rackmount or tower configurations e Supports Emergency Power Off EPO via built in interface 2 6 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Battery independent restart ensures automatic UPS power up
9. t extemallbaliety 6kVA 5400W capacity and 4 AC outlets 2 L6 20R 2 L6 30R packs e Front panel LEDs with detailed With its detachable PDU the SU6000RT4UHV is easily hot swappable by a user of any skill set no need for PEE no ntonngend conte lengthy and expensive service calls and no downtime if a repair or battery replacement is needed In bypass anion e USB RS232 and SNMP communication ports with mode the PDU passes power to equipment without the use of the power and battery modules allowing them to be removed while keeping your application in operation included PowerAlert software for UPS battery backup keeps connected equipment operational through short power failures and provides time to Sele Eo metvoii power save data and perform an orderly system shutdown in case of a prolonged blackout The SU6000RT4UHV s runtime can be expanded with optional external battery packs The SU6000RT4UHV features a highly efficient 96 economy mode setting that can significantly reduce a facility s energy costs by minimizing heat output reducing cooling requirements and consuming less electricity An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions The LCD LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions 1 6 management and control e 250 000 Ultimate Lifetime Insurance U S Ca
10. y mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6