Home
Tripp Lite SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
Contents
1. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 200 240V 5kVA 4 5kW On Line Highlights Double Conversion UPS Extended Run SNMP ge toga Webcard 4U Rack Tower USB DB9 Serial ee MODEL NUMBER SU5000RT4UHV e 200 208 220 230 240V 50 60Hz output high efficiency economy mode option e 4U Rack Tower compatible Hot swappable batteries e USB RS232 amp EPO ports support for SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e NEMA L6 30P input 3 wire L6 30R amp L6 20R outputs Description Tripp Lite SUS5000RT4UHV 5000VA 5kVA 4500 watt on line double conversion UPS system offers complete power protection for critical server network and telecommunications equipment in a single 4U rack tower Package Includes e SU5000RT4UHV UPS System e 4 post rackmount rails compatible housing Full time active power conditioning provides clean continuous dual conversion AC output p 9 p gp p e PowerAlert software and free of voltage fluctuations power interruptions and line noise Fault tolerant auto bypass prevents unexpected amesem service interruptions during UPS overload or internal fault conditions Single all in one rack tower housing installs in only 4 rack spaces 4U with a maximum installed depth of only 20 7 in 52 6 cm Mainta
2. double conversion power conditioning Overvoltage Correction 2 output voltage regulation during overvoltages to 280V full load 300V 90 load or less Undervoltage Correction 2 output voltage regulation during undervoltages to 156V full load 100V 50 load or less USER INTERFACE ALERTS amp CONTROLS Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options FrontiPanel LON Display LED LCD panel rotates for viewing in rack tower formats see manual 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and Switches execute scrolling LCD functions A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD LED Indicators He screen offers additional information and control options SURGE NOISE SUPPRESSION UPS AC Suppression Response Instantaneous Time PHYSICAL Included Mounting Accessory 4 post rackmount installation accessories included Description Installation Form Factors Supported 2 post rackmount 2POSTRMKITHD Tower 2 9USTAND with Optional Accessori
3. e sine wave output within 2 of selected 200 208 220 230 240V nominal in double conversion mode Corrects brownouts to 156V at full load 100V at 50 load or less Corrects overvoltages to 290V at full load 300V at 90 load or less Supports 50 60Hz operation for worldwide frequency compatibility Double conversion operation offers full time AC to DC then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network grade AC surge and noise suppression Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 USB and optional SNMP card slot interfaces UPS card slot supports one card based network interface option part SNMPWEBCARD or dry contact monitoring accessory part RELAYIOCARD Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module HID compliant USB interface enables integration with built in power mana
4. es UPS Power Module Dimensions 6 85 x 17 5 x 20 7 hwd in i i UPS Power Module Dimensions 17 4 x 44 5 x 52 6 hwd cm UPS Power Module Weight Ibs 113 6 UPS Power Module Weight kg 51 6 4 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS Shipping Dimensions hwd in 12 7 x 23 6 x 29 1 UPS Shipping Dimensions hwd 32 3 x 60x 73 9 cm f Shipping Weight Ibs 151 8 UPS Housing Material Steel ENVIRONMENTAL 5 to 90 non condensing AC Economy Mode BTU Hr Full 638 Load AC Mode Efficiency Rating 100 90 Load AC Economy Mode Efficiency Rating 96 100 Load ft Operating Elevation ft 0 to 6560 ft 0 to 2000 m Audible Noise 65 dB at 1m front side Operating Elevation m 0 2000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Two contact closure monitoring options available RELAYIOCARD with six configurable contact closure outputs Network Monitoring Port Description uses UPS card slot and RELAYIOMINI with 3 configurable contact closure outputs requires removal of USB port module PowerAlert Software Included Communications Cable USB DB9 serial and EPO cables included LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8 ms typical power failure respon
5. from mains power Double conversion mode is automatically restored as the overload is cleared 2 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Power Factor Nominal Output Voltage s 200V 208V 240V Supported Frequency Compatibility 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating Output Voltage Regulation Line 2 Mode Output Voltage Regulation ANo Economy Line Mode Sato Frequency Compatibility Details Mode INPUT BATTERY Full Load Runtime min 3 5 minutes 4500 watts Half Load Runtime min 11 minutes 2250 watts Expandable Battery Runtime Supports extended runtime with optional external battery packs BP192V1037C 1PH BP192V12 3U BP192V1407C 1PH BP192V557C 1PH BP192V787C 1PH BP192V5RT2U limit 1 External Battery Pack Compatibility 3 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Battery Recharge Rate Included 6 hours from 10 to 90 typical full load discharge Batteries Internal UPS Replacement Battery Cartridge RBC5 192 qty 1 Battery Access Front panel battery access Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online
6. gement and auto shutdown features of Windows and Mac OS X Includes Free PowerAlert monitoring software packages PowerAlert LOCAL for desktops and small business networks PowerAlert NSA Network Shutdown Agent for larger networks and PowerAlert NMS Network Management System for monitoring up to 250 SNMP enabled UPS PDU and other networking devices Front panel LEDs and LCD readout with scroll controls support front panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off EPO via built in interface Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement BP192V12 3U external battery packs are field replaceable and hot swappable Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating 250 000 connected equipment insurance Specifications General Info OUTPUT Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Output Capacity Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly
7. ins full time sine wave output within 2 of selectable 200 208 220 230 240V nominal during brownouts as low 100V and overvoltages as high as 300V Expandable runtime is supported with optional BP192V12 3U external battery packs Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs Network grade AC surge and noise suppression Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 and USB interfaces Optional SNMP Web and contact closure communications card accessories available HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto shutdown of connected systems as UPS batteries become depleted Included software packages include PowerAlert Local PowerAlert Network Shutdown Agent and PowerAlert Network Management System fo
8. r complete support for a wide variety of application types Supports Emergency Power Off EPO via built in interface Front panel LEDs and LCD readout with scroll controls support front panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations LED LCD display panel rotates for viewing in rackmount or tower configurations L6 30P input plus two L6 30R and two L6 20R outlets External battery packs are field replaceable and hot swappable 250 000 connected equipment insurance Features e Tripp Lite SU5000RT4UHV 5000VA 5kVA 4500 watt on line double conversion UPS system in a single 4U rack tower compatible housing e Full time active power conditioning maintains clean continuous dual conversion AC output free of voltage fluctuations power interruptions and line noise 1 6 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions L6 30P input plug 2 L6 30R and 2 L6 20R UPS supported outlets Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 1 required for SU5000RT4UHV Optional 2 9USTAND supports upright tower placement 1 required for SU5000RT4UHV Maximum installed rack depth of only 20 7 in 52 6cm inches Maintains full tim
9. se in optional economy mode Low Voltage Transfer to Battery 156V full load 100V 50 load or less derates linearly Power Setpoint High Voltage Transfer to Battery 280V full load 300V 90 load or less Power Setpoint 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SPECIAL FEATURES Cold Start Startup in Battery Mode i f During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries Green Energy Saving Features a mode operation Support for daily startup and shutoff Schedulable daily hours of economy CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance ree U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6
Download Pdf Manuals