image

Contents

1. Libretto di Istruzioni Instructions Manual Manuel d lnstructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning 75 75 75 INDICE SUGGERIMENTI AEE acs cris ceva a Guia ra ofthe conn 4 CARATTERISTICHE al ot ea at ti 5 INSTAR TAZIONES Foca 6 ee ae ren Sore 9 ENZA ONE Nan 10 INDEX RECOMMENDATIONS AND SUGGESTIONS 13 CT NG Na ott ag en aul oan 14 ING PAU TON ce eet are he tae en 15 Ne wl 18 SUPINE NIN atl bs 19 SOMMAIRE ET SUGGES TIONS steers ance cer hte cores eevee ene eu eure 22 CARACTER TI UES a PN oh ara Deas ln Te 23 re ce 24 27 28 INHALTSVERZEICHNIS EMPFEHLUNGEN
2. 72 YXO GA es er ah a a an ea a 73 INNEHALL REKOMMENDATIONER OCH TIPS 76 EGENSKAPER trad Sat a ad a ce NG ne ae a Misael wale 77 INSTALLA ION a ain caret A RE ed a 78 IIMs 81 sc a Saat 82 RECOMMENDATIONS AND SUGGESTIONS A The Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from in correct or improper installation e The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please re fer to the paragraphs on working dimensions and installation e Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood e For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diame ter 120 mm The route of the flue must be a
3. minutes after which the system returns to the speed that was set before Suitable to deal with maximum levels of cooking fumes Press and hold the button for approximately 5 sec onds with all the loads turned off Motor and Lights to turn the Activated Charcoal Filter alarm On and Off 24H function Turns the suction motor on at speed one and effects one 10 minute extraction every hour F Delay function Activate automatic switch off with a 30 delay Suit able to complete elimination of residual odours Can be activated from any position and is disabled by pressing the button or turning the motor off Press and hold the button for approximately 5 sec onds with all the loads turned off Motor and Lights to turn the Remote Control On and Off G When the filters alarm is triggered the alarm can be reset by pressing and holding this button for approxi mately 3 seconds These indications are only visible when the motor is turned off Displays HI and the time remaining once every sec ond FC Dot 2 flashes Alarm FC Dot 1 flash Alarm Off Displays 24 and the dot at the bottom right flashes once every second while the motor is running It is disabled by pressing the button Displays the operating speed and the dot at the bot tom right flashes once a second IR Dot 2 flashes Alarm IR Dot 1 flash Alarm Off FF flashes three times When the procedure terminates the indication shown
4. 7 2 1 on the wall at X mm below the first bracket X height of the upper chimney section aligning the centre notch with the vertical line Mark the wall at the centres of the bracket holes Drill 8 mm holes at all the marked centre points Insert the wall plugs 11 in the holes Fix the brackets using the 12a screws 4 2 x 44 4 supplied with the hood Fitting the hood body Open the panels see the paragraph on Maintenance Remove the Metal grease filters using the handles provided Adjust the two screws Vr in the brackets 11a so that they are at the start of their travel Hook the hood body to the two brackets 11 From the inside of the hood body turn screws Vr to level the hood body itself Fasten safety screw 11 29 Close the panels Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the 22 chimney using either flexible or rigid pipe 9 150 120mm choice of which is left to the installer To install a 150 pipe To install the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied To install 120 pipe To install a 120 mm air exhaust connection insert re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied e Remove any activated charcoal filters RECYCLIN
5. UND HINWEISE 31 CHARAKTERISTIKEN PNK E a O ees a Fa tect INHOUDSOPGAVE MAN 40 EIGENSCHAPPEN a 41 42 45 ONDERHOUD 46 INDICE CONSEJOS Y SUGERENCIAS aie eens 49 CARACTER STICAS nna 50 NE ee E E N SN ray ne ne 51 E E E OR ney E 54 INDICE CONSELHOS SUGESTOES e 58 CARACTERISTICAS 59 INSTALACAO 60 UTILIZACAO e EEE 63 MANUTENCAO is ate cut dal ee i Wa ESS cht SL cat 64 eden tale 67 68 69
6. lower part of the hood Metal grease filters They can be washed in the dishwasher and need to be cleaned whenever the FG sign appears on the display or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn Lights and the Suction Motor off Press button and hold it for at least 3 seconds see Use paragraph Cleaning the Filters Open the Panels by pulling from the centre see Maintenance paragraph e Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing If the surface of the filter changes colour as time goes by this will have absolutely no effect on the efficiency of the filter itself e Replace taking care to ensure that the handle faces forwards Close the panels Activated Charcoal Filter Recirculation Version It cannot be washed or regenerated and must be changed when the FC symbol on the display appears or at least once every 4 months The Alarm signal if it has been activated only appears when the Suction motor is turned on Activating the alarm signal e In Recirculation Version Hoods the Filter Saturation Alarm must be activated on installation or at a later date Turn the Lights and the Suction Motor off Press D and hold for approxi
7. previously turns off FG indicates need to wash the metal grease filters The alarm is triggered after the Hood has been in operation for 100 working hours FC indicates the need to change the activated char coal filters and also to wash the metal grease filters The alarm is triggered after the Hood has been in operation for 200 working hours Button is pressed in cycle al nl intensity Button is pressed in cycle Keyboard Lock it is possible to lock the keyboard for example when cleaning the Glass surface when the Hood has Motor and Lights turned off Press A for approximately 5 Seconds to enable or disable the Keyboard Lock which is always confirmed by flash of 00 Keyboard lock Enabled 2 flashes of 00 Keyboard lock Disabled MAINTENANCE REMOTE CONTROL OPTIONAL The appliance can be controlled using a remote control powered by 1 5 carbon zinc alkaline batteries of the standard LR03 AAA type not included Do not place the remote control near to heat sources e Used batteries must be disposed of in the proper manner Opening and locking the Panels Open the Panels by pulling from the centre The top panel is locked by means of a rod the mobile end of which is inserted into the hole provided on the side of the Hood body The lower panel is opened by pulling and is fitted with a safety cable to prevent it from dropping down and hitting the
8. G VERSION AIR OUTLET To install the hood in recycling version the optional charcoal filter kit must be purchased Remove the chimney angle bracket Screw the filter cover onto the air outlet using four screws 12 2 9 x 12 5 Fix the air outlet grid 8 on the recirculation air outlet using the 2 screws 12d 2 9 x 9 5 provided ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hood Upper exhaust flue e Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12 2 9 x 6 5 supplied Lower exhaust flue Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood body using 2 screws 12 2 9 x 6 5 supplied Control panel Display Displays the set speed Decreases the working speed Displays the set speed Displays the set speed Activate intensive speed from any other speed in cluding motor off This speed is set to operate for 10
9. mately 5 Seconds The message FC Puntino flashes twice A C Filter saturation alarm ACTIVATED The message FC Puntino flashes once A C Filter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button and hold it for at least 3 seconds see Use para graph Changing the Filter Open the Panels by pulling from the centre see Maintenance paragraph e Remove the Metal grease filters Remove the saturated Activated Charcoal Filters as indicated A e Fit the new Filters as indicated Replace the Metal grease filters Close the panels Lighting LIGHT REPLACEMENT 20 W halogen light e Remove the snap on lamp cover by levering it from under the metal ring supporting it with one hand e Remove the halogen lamp from the lamp holder by pulling gently e Replace lamp with a new one of the same type making sure that you insert the two pins properly into the housings on the lamp holder Replace the snap on lamp cover
10. ore carrying out any maintenance work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol A on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 550 mm min CHARACTERISTICS Dimensions 300 MIN 530 MAX 990 500 Min Min 450mm 450mm Components Ref Q ty Product Components 1 1 Hood Body complete with Controls Light Blower Filters 2 1 1 Upper Section 2 2 1 Lower Section 8 1 Directional Air Outlet grille 10 1 Dumper 16 1 Filter cover Ref Installation Components 7 21 2 Upper Chimney Section Fixing Brackets 11 6 Plugs 11a 2 Plugs SB 12 10 12a 6 Screws 4 2
11. s short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to elimi nate kitchen smells Never use the hood for purposes other than for which it has been designed e Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flamb under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern ing use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appli ance MAINTENANCE Switch off or unplug the appliance from the mains supply bef
12. x 44 4 12 10 Screws2 9x6 5 12d 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual INSTALLATION Wall drilling and bracket fixing 2 124 ito _ 4 210 210 4 ae 5 if 1004 482 400 A As a first step proceed with the following drawings a vertical line up to the ceiling or up to the upper limit at the centre of the area in which the hood is to be fitted a horizontal line minimum 1004 mm above the cooker top Mark a point 1 on the horizontal line 247 mm to the right of the vertical reference line Repeat this operation on the other side checking that the two marks are levelled Mark a reference point 2 as indicated at 210 mm from the vertical reference line and 482 mm above the cooker top Repeat this operation on the other side checking that the two marks are levelled Drill at the marked points 1 using a 12 mm drill bit Drill at the marked points 2 using a 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and tighten the screws Insert plug 11 into holes 2 To install a decorative chimney optional Place bracket 7 2 1 on the wall about 1 2 mm from the ceiling or from the upper limit aligning the centre notch with the vertical reference line Mark the wall at the centres of the bracket holes Place the bracket

Download Pdf Manuals

image

Related Search

Related Contents

Service Address: www.carromco.com  - TRIUMPH BOARD as  Patriot Memory microSDHC 16GB  TS0866 Four-Door Controller Installation Manual  SPEEDFLOW UL BRADLEY 05_10_09.FH11  Guía de instalación  HP 12c Platinum - Calculatrices-hp  Dettaglio Scheda PDF  OM, 355 FX, 355 FXT, 355 RX, 355 FRM, EPA, 2008-01  