LevelOne IPS-0008

image

Contents

1. IE 5 0 Netscape 6 2 Opera 6 Mozilla 1 5 FireFox 1 0 Other browser which is compatible to above Network Protocols TCP IP UDP IP SNMP V1 SNTP DNS DHCP SMTP HTTP Telnet TFTP SSL V3 SSH V1 Sensor amp Detector support Universal any device with normally open or closed Example Humidity amp Temperature Vibration Airflow Water Leak Smoke Door Glass Broken and etc EMD Box Size 57 4 W x 37 6 D x 29 2 H mm Power No need for external power supply Function 1 IPS 0008 supports 1 EMD device 1 EMD device supports up to 2 sensors Product Diagram Ethernet Cable RJ 45 Fiber 7 i FE Motion Door Open Smoke Detector Detector Detector op Mobile D SMS WAP 7 NMS Browser a Telnet Email PDA Internet n e tp T Ea Local User Router Cable DSL Modem Up to 8 Server Device IPS 0008 IP Power Switch IPS 0008 IP Power Switch Rack mount Brackets U type Handle amp Screws CD Manual Rubber Feet Quick Installation Guide Power Cord Console Cable Order Information Package Contents Optional Accessories EMD Environmental Monitored Device EMD All mentioned brand names are registered trademarks and property of their owners Technical specifications are subject to change without notice Copyright 2009 Digital Data Communications GmbH All Rights Reserved V1 0
2. level il Zn an E one IP Power Switch H W Version 1 LevelOne IPS 0008 provides users with the ability to turn power On Off to any combination of network equipment which is locked up and thus requires power down to reboot Remotely Power On Off from Web Browser IPS 0008 gives users the ability to perform this function from anywhere anytime over the Internet with the Internet Explorer browser This IP power switch is ideal for rebooting servers and other network equipment in server farms and for use as part of remote management systems in office industry environments Intelligent Power Management Each IPS 0008 provides eight individual outlet switches The IPS 0008 is designed to remember the configuration of each outlet should there be a power loss thus providing the ability to power on power off or reboot a remote E waged Key Features Turns power On Off any AC powered device Group or Schedule via IP network console and by manual Intelligent turn on off devices based on event occurrence or planned schedule Support management via web browser NMS Telnet SNMP and console Administrator and multiple users with password protection for double layer security Supports two digital outputs to trigger extended devices Monitor Temperature Humidity Snoke Detector via EMD Environmental Monitoring Device Optional IPS 0008 network device whenever the power cable is plug
3. al IPS 0008 220V 10 Amps each Outlet or 15 Amps Total Breaker IPS 0008 110V 15 Amps IPS 0008 220V 10 Amps Console RS 232 Dry Contact UPS Male DB9 RS 232 Status Indicator Remote Control Indicator 1 Red LED X 8 Channels Outlet Power Indicator 1 Green LED X 8 Channels Current Meter 6 Orange LED X 9 Channel Input Status Indicator Green 7 Segment X 3 Buttons 8 Remote Control Buttons and 1 Reset Button Digital Output 2 Channels switch voltage 48VDC 10A max Operating Environment Temperature 0 C 40 C Humidity 10 80 non condensed Dimensions 436 W mm x 270 D mm x 44 H mm Weight 3 8 kg 8 41bs Network Security Administrator and multiple users with password protection for double layer security Address specific IP security masks to prevent unauthorized access Secure Socket Layer SSL V3 128 bit encryption Secure Share SSH V1 3DES encryption Web Smart Switches a Power Management Eight power outlets that can be turned on or off in multiple ways with easy monitoring of current consumption Intelligent turn on off devices based on event occurrence or planned schedule Comprehensive power management and flexible configuration through web browser NMS Telnet SNMP or HyperTerminal console Status Report Detailed data logging for statistical analysis and diagnostics Event notification through SNMP or Email alerts Daily history report through Email Supported Web Browser
4. ged into the IPS 0008 outlet Easy Maintenance and Configuration the IPS 0008 provides event triggered or schedule based control to turn On Off connected equipments The IPS 0008 is protected against unauthorized access with SSL and SSH encryption Administrator and users who have been properly designated can control and view the switching state of any specified combination of sockets EMD Environmental Monitoring Device Optional the EMD is a connectivity device that allows you to remotely monitor the temperature humidity smoke detector motion detector and universal any device with normally open or closed Ethernet port Console port Operation mode Reset Remote control button Output power Status Input power Status Status Input power 10 Breaker 11 Power Outlet 12 Dry contact port 13 digital Output ee ae Works Well With a peptide 8 port D sub PS 2 KVM Switch EMD Environmental Monitored Device EMD www level1 com one world one brand_one level_ Technical Specifications Hardware Network Interface 10 100Mbps RJ 45 Ethernet port x1 Input Power Interface IPS 0008 110V 100 125VAC 50 60 Hz 15A IPS 0008 220V 200 250 VAC 50 60 Hz 10A Output Power Interface Socket IPS 0008 110V 8 Channels NEMA 5 15R IPS 0008 220V 8 Channels IEC C13 Voltage IPS 0008 110V 100 125VAC 50 60 Hz IPS 0008 220V 200 250 VAC 50 60 Hz Load IPS 0008 110V 15 Amps each Outlet or Tot

Download Pdf Manuals

image

Related Search

Related Contents

Auto Blogging Software User Manual  もくじ セーフティバー取扱説明書 施工説明書  GE JV966DSS Use and Care Manual    RBSS 0003-1 - 公益社団法人 日本防犯設備協会  User manual - Electrolux  

Copyright © All rights reserved.
Failed to retrieve file