Eaton KIT-CABLRES-01 rack accessory

image

Contents

1. e 19 x 3 4 2U x 14 5 e Electromagnetic breakers with e Activated Locally or Remotely PH X including 2 5 recess a long time delay curve provide both powers up followed 4 seconds later by e Approximate shipping weight 29 Ib manual on off switching and trips PH Y which is followed 4 seconds later automatically in an overload condition PH Z then 4 seconds later the EMI RFI FILTERING sequenced remote activates the next e Common Mode line to ground LOCAL OFF REMOTE SWITCHING system in line e Differential Mode line to line e Local Power on or off to the switched e Refer to Chart 9 on page 20 outlets 0 1 0 PORTS e Off When breaker is on but this switch Remote on off and EPO control EPO SPIKE SURGE SUPPRESSION 15 in the off mode you will have power overrides remote and local control 270V MOV L N to the unswitched outlets only e Sequence power up additional e Refer to Chart 1 on page 20 e Remote Power on or off to the equipment down line standard on all units switched outlets via a remote device e atching remote N C 11 NEMA OUTLETS e When using the Latching remote option momentary start LT systems e 2 Unswitched outlets the selection switch is wired for e 1 Duplex and 1 twist lock per phase Remote Off Remote There is no local POWER INPUT control Power cable with plug is attached to unit 4 INDICATOR LIGHTS through the front panel cable grip e Main breaker pow
2. 2U x 14 5 recessed e Approximate weight 29 Ib 14 NEMA OUTLETS e 2 unswitched outlets e 12 switched outlets 4 per phase e 4 INDICATOR LIGHTS e Main breaker power on to system and unswitched duplex e Power on to PH X Y Z outlets SPIKE SURGE SUPPRESSION e 320V MOV L N e Refer to Chart 1 on page 20 EMI RFI FILTERING Common Mode line to ground e Differential Mode line to line e Refer to Chart 9 on page 20 LOCAL OFF REMOTE SWITCHING Local Power on or off to the switched outlets Off When breaker is on but this switch is in the off mode you will have power to the unswitched outlets only Remote Power on or off to the switched outlets via a remote device When using the Latching remote the selection switch is wired for Remote Off Remote There is no local control MULTIPLE TIME DELAY MTD PH X powers up immediately followed 4 seconds later by PH Y which is followed 4 seconds later PH Z then 4 seconds later the sequenced remote activates the next system in line PC2641 D MTD and PC2641 D LT only models PC2641 D Rear POWER INPUT e Power cable with plug is attached to unit through the front panel cable grip BRANCH CIRCUIT PROTECTION e UL498 Listed electromagnetic breakers with a long time delay curve provide both manual on off switching and trips automatically in an overload condition 4 REMOTE 1 0 PORTS e Remote on off and EPO control
3. G 1 120 240V 30A 2 2 pole 15A NA 24A Output UL489 L14 30P 120 240V 30A 2 2 pole 15A NA 24A Output UL489 L14 30P J 1 120 240 30 2 2 pole 15A NA 24A Output 01489 L14 30P 20A twist lock outlets are not available to fit a standard duplex opening so 15A outlets are used in these versions 6 15R L6 15R e The 982F3 is pictured at the left e his version features IEC C13 computer style outlets e he power input is 30A WWW EPDU COM 1 800 356 5794 Intelligent Power Control IPC3600 Series 1 20V or 240 15 20 30A Single Phase 50 60 Hz IPC3601 Rear IPC36XX Front Please refer to 18 for power cable assemblies to match your country specific requirements 5 E IPC3602 Rear CHASSIS 1 72 1U x Depth 9 5 x Width 19 0 Weighs approximately 12 Ib OVERLOAD PROTECTION e Push button circuit breaker pops out when an overload occurs SOFTWARE SECURITY e User name password security e Settings allow the administrator to e Powder coated black steel e Detachable mounting brackets allow for several mounting options NEMA or IEC 320 OUTLETS e PC3601 has 8 IEC 60320 type C13 computer style outlets e PC3602 has 8 NEMA 5 15R 3 prong outlets 12 INDICATOR LIGHTS Main power system on e Power on to outlets 1 8 e 2 Data and ethernet link POWER INPUT e EC 60320 Type C20 Inlet
4. WWW EPDU COM 1 800 356 5794 Single Phase Systems North American TPC115 10 Series 120V OR 240V 15A 20A and 30A 50 60 Hz RACK MOUNTED e 19 x 1 72 1U x 8 0 TPC115 10 D Front e Approximate shipping weight 14 Ib 10 NEMA OUTLETS e 2 unswitched on front and 8 switched on rear panel Unswitched outlets tied to the SW II outlet section POWER INPUT e Power cable with plug is attached through the rear panel cable grip 3 INDICATOR LIGHTS are to unit e Main breaker power on and power to the unswitched outlets e Power to the SW l outlets e Power to the SW II outlets SPIKE SURGE SUPPRESSION N L G N G e Refer to Chart 1 on page 20 NA US Approvals Voltage Input Output 50 60 Hz Current Input Current Output Full Load VA NEMA Outlets Circuit Breaker with Kick Guard EMI RFI Filter Multi Stage Surge Suppression Power Cord Length NEMA Power Input Plug Remote Control Panel refer to pages 16 17 EMI RFI FILTERING Common mode line to ground e Differential mode line to line e Refer to Chart 4 15A 20A units and Chart 5 30A units on page 20 OVERLOAD CIRCUIT PROTECTION e Electromagnetic breaker provides manual on off switching and trips in an overload condition LOCAL OFF REMOTE SWITCHING e local Power on or off to the switched outlets e Off When breaker is on but this switch is in the off mode you will have p
5. off mode you will not have power to the outlets Remote Power on or off to the switched outlets via a remote device Latching remote on LT models only the selection switch is wired for Remote Off Remote There is no local control Refer to page 16 for remote configurations REMOTE INTERFACE Remote on off and EPO control overrides remote and local control sequence Power Up additional equipment down line standard on all units Latching remote LT models only normally closed momentary start MULTIPLE TIME DELAY MTD Optional e Activated Locally or Remotely section 1 powers up followed 4 seconds later by Section 2 which is followed 4 seconds later Section 3 then 4 seconds later the sequenced remote activates the next system in line INDICATOR LIGHTS 5 e Power to Section 1 2 and 3 e 115 Vac or 230 Vac input selected OVERLOAD CIRCUIT PROTECTION e Electromagnetic breaker provides manual on off switching and trips in an overload condition AUTO VOLTAGE SELECTION e The AVS system automatically senses the input voltage and adjusts the internal components to use that voltage for the output RoHS EOMP AMT O07 9 SEC cTUVus CE cTUVus CE cTUVus CE NA NA 110 125V 110 125V 110 125V 110 125V 200 240V 200 240V 200 240V 200 240V 200 240V 20A 20A 20A 30A 30A 16A 16A 16A 24A 24A 1920 VA 3840 VA 1920 VA 3840 VA 1920 VA 3840 VA 2880 VA 5760 VA 5760 VA 2 Pole 20A 2 Pole 20
6. 1 CONDITION 1 A maintained contact between pins 2 amp 3 will turn off the switched outlets regardless of the position of the on off remote switch 6 9 MAINTAINED CONTACT START MAINTAINED CONTACT STOP EPO oo COMMON NOT GROUND SEQUENCED REMOTE Connect pins 1 2 3 of the sequence port to pins 1 2 amp on any remote port of the slave unit Do not connect to another sequence port The sequence port of the master unit activates 4 seconds after the final set of outlets turn on Additional units may be daisy chained in this fashion CAUTION THIS TYPE OF REMOTE IS NOT TO BE SUBSTITUTED FOR A SAFETY INTERLOCK EPO is normally open so removing the EPO connection will not shut down the power to the unit Latching Remote LT Control Interface START POWER REQUEST 1 EPO POWER OFF PIN COMMON NOT GROUND REMOTE START REQUIRES 2 CONDITIONS 1 A maintained contact between pins 2 amp 3 2 Amomentary contact between pins 1 amp 3 REMOTE POWER OFF OR EPO REQUIRES 1 CONDITION 1 Opening the maintained connection between pins 2 amp 3 Additional EPO or stop buttons can be connected in series between pins 2 amp 3 This will turn off the switched outlets regardless of the remote switch position 2 NIO MOMENTARY CONTACT START NIC MAINTAINED CONTACT STOP EPO COMMON NOT GROUND SEQUENCE REMOTE Connect pins 1 amp 2 of the sequ
7. 9 foot 12AWG 3 wire Bare Wire Pig Tail to C19 010 9334 NEMA 5 15P to C19 125V 15A Straight Blade 8 foot 14AWG 3 wire 010 9335 NEMA 5 20P to C19 125V 20A Straight Blade 8 foot 12AWG 3 wire 010 9336 NEMA 6 15P to C19 250V 15A Straight Blade 8 foot 14AWG 3 wire 010 9337 NEMA 6 20P to C19 250V 20A Straight Blade 8 foot 12AWG 3 wire 010 9338 NEMA L5 15P to C19 125V 15A Twist Lock 8 foot 11AWG 3 wire 010 9339 NEMA L5 20P to C19 125V 20A Twist Lock 8 foot 12AWG 3 wire 010 9340 NEMA L6 15P to C19 250V 15A Twist Lock 8 foot 14AWG 3 wire 010 9341 NEMA L6 20P to C19 250V 20A Twist Lock 8 foot 12AWG 3 wire 010 9342 C20 Male to C19 20A 8 foot 12AWG 3 wire wt 2 EATON CORPORATION ePDU Industrial Products Catalog 010 9343 CEE7 7 to C19 250V 16A EUROPE Schuko 2 5 1 5mm 3 wire Harmonized 010 9344 BS546A to C19 250V 15A BRITISH Old standard 2 5M 1 5mm 3 wire Harmonized 010 9345 AS NZS 3112 to C19 250V 15A AUSTRALIAN 2 5M 1 5mm 3 wire Harmonized 010 9346 132 to C19 250V 16A ISRAELI 2 5M 1 5mm 3 wire Harmonized 010 9347 CEI23 16 to C19 250V 16A ITALIAN 2 5M 1 5mm 3 wire Harmonized 010 9351 BS1363A to C19 250V 13A BRITISH 2 5M 1 5 mm 3 wire Harmonized 010 0025 8 foot 010 0027 6 foot 010 0028 4 foot 010 0029 2 foot C14 Harmonized 1 mm 3 wire to C13 100 240V
8. EPO overrides remote and local control e Sequence power up additional equipment down line standard on all units e latching remote normally closed momentary start Units with LT in part number i e PC2641 D LT or LT C US LISTED Voltage Input Three Phase 50 60 Hz 120 208V 120 208 Voltage Output Single Phase 50 60 Hz 120V 120 Current Input Per Phase 30A 30A Current Output Per Phase 24A 24A Full Load Per Phase 2880 VA 2880 VA NEMA Outlets 5 20R 5 20R Main Circuit Breaker on off switch 30 30 30A 30 30 30A Secondary Circuit Breakers Per Phase 20 20A 20 20A Unswitched Duplex Circuit Breaker 20A 20A EMI RFI Filter 30A 30A Surge Suppression 320V 320V Power Cord Length Plug Remote Control Multiple Time Delay 10 5 15 L21 30P Standard Remote NO 10 5 15 L21 30P Latching Remote NO 6 120 208 120 208V 120V 120V 30A 30A 24A 24A 2880 VA 2880 VA 5 20R 5 20R 30 30 30A 30 30 30A 20 20A 20 20A 20A 20A 30A 30A 320V 320V 10 5 15 L21 30P Standard Remote YES 10 5 15 L21 30P Latching Remote YES This system is designed to be controlled Locally or Remotely via a remote control panel refer to pages 16 17 WWW EPDU COM 1 800 356 5794 11 Three Phase Systems North American PC975 Series 120 208V Three Phase WYE 30A 50 60 Hz x 80 B 41 975 RACK MOUNTED OVERLOAD CIRCUIT PROTECTION MULTIPLE TIME DELAY MTD
9. KIT CABLRES 24 2235 Series Black 9 5 T2235 Fx Series Black 9 5 TPC4100 Series KIT CABLRES 01 KIT CABLRES 01 KIT CABLRES 01 VPC1917 1 KIT CABLRES 23 VPC1917 4 5 KIT CABLRES 23 You must purchase VPC1917 6 KIT CABLRES 24 cables separately VPC1917 7 KIT CABLRES 23 VPC2769 A2 KIT CABLRES 24 VPC2769 B2 KIT CABLRES 23 VPC2864 Series KIT CABLRES 23 VPC3106 Series KIT CABLRES 23 WWW EPDU COM 1 800 356 5794 19 20 Environmental Surge Suppression and EMI RFI Filter Performance CHART 1 TVSS Transient Voltage Surge Suppression MOV SPECIFICATIONS Continuous AC Voltage Continuous DC Voltage Max DC Leakage Low Varistor Voltage Limit High Varistor Voltage Limit Nominal Varistor Voltage Current For Varistor Voltage Max Clamp Voltage 8x20us Max Clamp Voltage Test Current Peak Current Rating 1 Pulse Peak Current Rating 2 Pulse Energy Rating 10x1000ys Energy Rating 8x20us Capacitance Impulse Response Time CHART 2 001 3000 150 Vac 200 Vdc 200 212 243 Vdc 236 1 360V 100A 12000A 9000A 170J 170J 1700pF 50 ns 270 Vac 360 Vdc 200uA 389 Vdc 453 Vdc 424 Vdc 1 mA 680V 100A 10000A 6500A 325J 325J 970pF 50 ns 320 Vac 420 Vdc 200 462 Vdc 540 503 Vdc 1 mA 810V 100A 10000A 6500A 385J 385J 820pF 50 ns EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 2 1 0 2 0 10 0 dB 15 25 45 50 DIFFERENTIAL INSERTION LOSS Mhz
10. both manual on off switching and open trip automatically with an overload condition 3 INDICATOR LIGHTS e Provided for each phase power ON via breaker E 1 TPC4100 AB Rear 12 NEMA OUTLETS e 4 Per phase PH Y and PH Z on the rear panel and PH X has two on the rear and 2 on the front panels POWER INPUT e Power cable with locking plug is attached to the unit through the rear panel cable grip KIT CABLRES 01 Optional Cable Restraint And Management System refer to page 19 UL cUL Listed UL cUL Listed UL cUL Listed UL cUL Listed NA 120 208V WYE 120 208 WYE 120 208V WYE 120 208V WYE 120 208V WYE 208V 120V and 208V X 120V 120 120 30A 30A 30A 30A 30A 24A 24A 24A 24A 24A 2880 VA 2880 VA 2880 VA 2880 VA 2880 VA 12 6 15R 6 5 15R 6 6 15R 12 5 15R 12 5 20R 6 5 20R 6 6 20R 3 2 pole 15A 3 2 pole 15A 3 2 pole 15A 3 2 pole 20A 3 2 pole 20A NO NO NO NO YES Latching 30A 30A 30A 30A NO 270V 150V 150V 150V 150V 10AWG 5wire 10AWG 5wire 10AWG 5wire 10AWG 5wire 10AWG 5wire 9 9 9 9 9 L21 30P L21 30P L21 30P L21 30P L21 30P B 1 3 111111141 41 TPC3474 RCP100 BLK LT The TPC3474 is compatible with the RCP100 BLK LT EATON CORPORATION ePDU Industrial Products Catalog Three Phase Systems North American PC2641 Series 120 208V Three Phase WYE 30A 50 60 Hz RACK MOUNTED e 19 x 3 4
11. 15A N A N A 8 5 15R 10 8 6 L5 30P 240V 30A 24A 5760 VA N A N A N A 4 L6 30R 10 8 6 L6 30P 2872 1 100 240V 20A input via C20 power inlet On Off switch with green power on light 6 IEC 60320 C13 receptacles 2 67 H x 11 L x SW 240V 120 240V 30A 30A Per Phase 24A 24A Per Phase 5760 VA 2880 VA Per Phase 3 2P 20A 6 15A N A N A N A N A 3 L6 20R 1 L6 30R 12 5 15R 10 3 6 10 4 6 L6 30P L14 30P LPC208 1P 240V 30A input and output 6 cable 10 3 terminated with a NEMA L6 30P There are 4 NEMA L6 30R outlets 7 75 W x 3 H x 10 Lx 3 H x 10 L LPC208 2P 240V 30A input and output 6 cable 10 3 terminated with a NEMA L6 30P There are 3 NEMA L6 20R outlets each with a 2 pole 20A breaker and kick guard and 1 L6 30R unswitched outlet 7 75 W x 3 H x 101 100 240V 20A 15A 120V 10A 240V 1800 VA 2400 VA N A N A N A 6 C13 IEC C20 Inlet NA WWW EPDU COM 1 800 356 5794 15 16 Sample Remote Circuits Standard Remote Control Interface START POWER REQUEST PIN 1 EPO POWER OFF PIN2 COMMON NOT GROUND REMOTE START REQUIRES 2 CONDITIONS 1 he on off remote switch must be in the remote position 2 Amaintained closure between pins 1 amp 3 will turn the unit on REMOTE POWER OFF REQUIRES 1 CONDITION 1 Opening the maintained connection between pins 1 amp 3 will turn off the switched outlets REMOTE EPO REQUIRES
12. Front 6 69 FC Qus LISTED Remote access via WAN LAN TCP IP Modem or Direct RS 232 Prevent costly site visits with remote reboot and power management HS IPC3402 2756 Rear Sequence power up and down with Eaton s patented Multiple Time Delay circuitry Prevent inrush current problems such as system lock ups and automatically control the order in which equipment within your network powers up or down Strap up to 10 IPC34XX systems together for control of 80 outlets Use one IPC34XX NET unit as the main system and strap nine less expensive IPC34XX non NET units together to save money and increase overall control of your network equipment 100 240 15A or 20A input IPC3401 or IPC3401 NET One unit to purchase stock and utilize worldwide Ethernet Strapping Switch Remote access disable and Local on off control When you need to work locally with the IPC34XX systems the push of a button will prevent anyone from coming in remotely and the individual outlet on off switches are also located on the front panel Cross platform compatible with Telnet and Browser Control RS485 Strapping Connectors You can easily access and control the IPC34XX with either PC Mac Linux or Unix platforms RS232 Serial DB9 Connector running Telnet or via your Web browser IE i i 4 Equipment Equipment Up To 10 IPC Units Can Be Stacked Toget
13. can be created to perform an action on multiple outlets Outlet control includes individual group and all outlet global control Outlet actions include on or off and reboot Global sequence allows all the outlets to be turned on or off in a preset sequence up to 999 seconds Outlet reboot automatically turns an outlet off and back on with one command at a preset time up to 999 seconds E mail notification allows up to two e mail addresses to receive notifications of alerts or events AUTO EVENT SCHEDULING e Administrator can configure on or off events for outlets or groups The event occurs at the preset time daily or weekly Approvals CB CE UL cUL Listed FCC UL cUL Listed FCC NA Voltage Input Output 50 60Hz 100 240V 120V 200 240V Current Rating 16A 16A 24 Full Load V 1920 VA Q 120V 1920 VA 5760 VA 3840 VA 240V Ethernet Serial YES YES YES Outlets IEC C13 NEMA 5 15R IEC C13 Circuit Breaker 20A 20A 2 15 15A EMI RFI Filter 20 20 NO Surge Suppression YES YES YES Power Input C20 Inlet C20 Inlet Attached Power Cable Plug Not Included Not Included 10 L6 30P EATON CORPORATION ePDU Industrial Products Catalog Intelligent Power Control IPC3400 Series 1 20V or 240V 15A Single Phase 50 60 Hz INTELLIGENT POWER LER TABLE e Height 3 4 x Depth 7 5 x Width 5 75 e Approximate shipping weight is 6 Ib OUTLETS e 3400 1 has 4 NEMA outlets e 3400
14. has 4 IEC outlets SPIKE SURGE SUPPRESSION e 1 1 0 N G e Refer to chart 1 on page 20 POWER INPUT e EC C14 power inlet e Power cable included ATER TE Pret fi 95 ADDRESSING e he IPC comes with a default address but you can also create your own with any four alphanumeric characters WATCH DOG AUTO REBOOT e he IPC will monitor the control connection 6 INDICATOR LIGHTS AB version has 8 C13 to C14 and automatically reboot itself if the e 1 Main power A1 version has 9 C13 to 5 15P connection locks up The auto reboot is e 1 Data light activated by the time out period running e 4 Power on to outlets 1 4 COMMUNICATIONS 15232 Serial 9600 baud only e Optional ethernet control RJ45 connector add NET to part number e Data terminal emulation software is required OUTLET STATUS e Query the IPC for Outlet and Watchdog status i e outlets are on or off MULTIPLE TIME DELAY MTD e Turn outlets on or off at one time e Sequence power up and power down to down to zero When this occurs the IPC will shut down all outlets for four seconds and restart in the default or user defined sequence set the Time Out Period to any number 0 9 where each digit represents 30 seconds i e 3 120 seconds user defined to communicate with the IPC internal outlets 1 4 with a four second time delay COMMANDS AVAILABLE command codes such a Telnet or f
15. 0 systems together over CAT 5 cable e local one on off switch for each outlet e NET SYSTEMS ONLY RJ45 for network connections Ethernet REMOTE DISABLE e With the push of a button disable remote access to the IPC when needed POWER SUPPLY e The IPC3401 series features a full range power supply for operation at 100 240 Vac input output UL cUL FCC UL cUL FCC UL cUL FCC 120V 120V 120V 20A 20A 20A 16A 16A 16A 1920 VA 1920 VA 1920 VA 5 15 5 15 5 20R 20 20 20 20 20 20 2101 2101 2101 Type C20 Inlet Type C20 Inlet Type C20 Inlet NO YES NO YES YES YES BAUD RATE e Default 9600 baud EMI RFI FILTERING Common Mode Line to Ground e Differential Mode Line to Line e Filtered inlet isolates noise before entering the system e Refer to chart 3 on page 20 e P3402 2756 and IPC3402 2930 do not have filtering SPIKE SURGE SUPPRESSION TVSS e Line to Line e Refer to chart 1 on page 20 e Multi stage both MOVs and SAPs BRANCH CIRCUIT PROTECTION e UL498 Listed Main Disconnect Breaker and guard with a long time delay curve provides manual on off switching and trips in an overload condition POWER INPUT e EC 60320 Type C20 EMI RFI Filtered Inlet e Mating power cables must be ordered separately page 18 e PC3402 2756 attached 10 cable and NEMA L5 30P OUTLET STATUS Query the IPC for Outlet and Watch Dog status i e outlets are on or off STRAPPING e Strapping all
16. 2 1 0 2 0 10 0 dB 10 22 32 50 CHART 3 010 0317 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 01 1 10 20 50 100 dB 8 29 40 50 68 40 DIFFERENTIAL INSERTION LOSS Mhz 01 1 10 20 50 100 dB 8 23 45 58 32 28 CHART 4 025 2023 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 15 50 1 0 5 0 10 0 30 0 dB 6 19 28 42 45 50 DIFFERENTIAL INSERTION LOSS Mhz 15 50 1 0 5 0 10 0 30 0 dB 6 6 30 50 30 30 EATON CORPORATION ePDU Industrial Products Catalog CHART 5 025 3021 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 15 50 1 0 5 0 10 0 30 0 dB 6 19 20 42 45 50 DIFFERENTIAL INSERTION LOSS Mhz 419 90 1 0 5 0 10 0 30 0 dB 2 40 60 65 57 59 CHART 6 025 2833 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 5 10 50 100 200 50 0 dB 18 40 48 62 80 70 60 DIFFERENTIAL INSERTION LOSS Mhz D 1 0 5 0 10 0 20 0 dB 21 33 41 50 50 50 CHART 8 025 4000 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 05 20 1 0 5 0 20 0 100 0 dB 0 35 71 15 66 48 DIFFERENTIAL INSERTION LOSS Mhz 05 20 1 0 2 0 5 0 10 0 dB 20 30 72 63 58 51 CHART 9 025 3031 EMI RFI FILTERING COMMON MODE INSERTION LOSS Mhz 05 419 50 1 5 5 0 20 0 dB 4 18 38 44 50 50 DIFFERENTIAL INSERTION LOSS Mhz 05 15 1 0 1 5 5 0 20 0 dB 12 20 40 60 50 50 CHART 10 Environmental Operating Temperature is 0 to 50 C Storage Temperature is 40 to 70 C Altitude Maximum 10 000 ft Relative Humidity is 95 Max Non Condensing UNITED STAT
17. A 2 Pole 20A 3 2 Pole 10A 3 2 Pole 10A YES NO YES YES YES YES 20A YES 20A YES 20A YES 30A YES 30A 320V 320V 320V 320V 320V IEC 60320 60320 IEC 60320 IEC 60320 IEC 60320 Type C13 Type C13 Type C13 Type C13 Type C13 Standard Latching Latching Latching Latching Not Included Not Included Not Included 10 3 15 10 3 15 C20 Inlet C20 Inlet C20 Inlet Bare Wire L6 30P Remote Control Panel refer to pages 16 17 KIT CABLRES 08 Optional Cable Restraint System refer to page 19 WWW EPDU COM 1 800 356 5794 Three Phase Systems North American TPC4100 Series 120 208V Three Phase WYE 20A and 30A 50 60 Hz CHASSIS e 19 x 1 72 1U x 9 5 e Approximate shipping weight 19 Ib e Detachable mounting brackets allow for several mounting options EMI RFI FILTERING e Common Mode line to ground e Differential Mode line to line e Refer to Chart 8 on page 20 SPIKE SURGE SUPPRESSION e Line to line e Refer to Chart 1 on page 20 C US LISTED Approvals UL cUL Listed AC Voltage Input 120 208V WYE 50 60 Hz AC Voltage Output 120 Current Input Per Phase 20 Current Output PerPhase 16A Full Load Per Phase 1920 VA NEMA Outlets 12 5 20R Listed Circuit Breaker 3 1 pole 20A Remote NO EMI RFI Filter 30A Surge Suppression 150V Cable 12AWG 5wire g NEMA Power Input L21 20P BRANCH CIRCUIT PROTECTION e UL489 Listed electromagnetic breakers with a long time delay curve provide
18. A 30A 270V 150V 320V 270V 10 3 15 10 3 15 L5 30P L6 30P KIT CABLRES 08 Optional Cable Restraint System refer to page 19 Single Phase Systems International TPC2365 Series 110 125V 200 240V 16A Single Phase 50 60 Hz RACK MOUNTED e 19 x 1U 1 72 x 7 e Approximate shipping weight 9 Ib e 2365 2980 and 2365 3732 are 9 5 deep EMI RFI FILTER e Differential Mode line to line e Common Mode line to ground e Refer to Chart 4 on page 20 SPIKE SURGE SUPPRESSION e Line to Line e Refer to Chart 1 on page 20 IEC 60320 C20 Power Inlet e Power inlet is on the rear panel e Rated by UL CSA at 125 Vac 20A or 250 Vac 16A Rated by TUV at 250 Vac 16A IEC 60320 OUTLETS 12 e Three sections of 4 switched outlets on the rear panel Each group of four outlets are Rated by UL CSA up to 250 Vac 15A Rated by VDE at 250 Vac 10A Approvals Voltage Input Output 50 60 Hz Current Input Current Output Full Load VA Circuit Breaker Multiple Time Delay EMI RFI Filter Surge Suppression Outlets Remote Control Power Cable Power Input M cTUVus 110 125V 200 240V 20A 16A 1920 VA 3840 2 Pole 20A NO YES 20A 320V IEC 60320 Type C13 Standard Not Included C20 Inlet RCP100 GRY REMOTE SELECTION SWITCH Local Power on or off to the switched outlets Off When breaker is on but this switch is in the
19. ES 8609 Six Forks Road Raleigh NC 27615 U S A Toll Free 1 800 356 5794 www epdu com ETN Powering Business Worldwide CANADA Ontario 416 798 0112 Toll Free 1 800 461 9166 LATIN AMERICA Brazil 55 11 3616 8500 Caribbean 1 949 452 9610 M xico amp Central America 52 55 9000 5252 South Cone 54 11 4343 6323 EUROPE MIDDLE EAST AFRICA Denmark 45 3686 7910 Finland 358 94 52 661 France 33 1 6012 7400 Germany 49 0 7841 604 0 Italy 39 02 66 04 05 40 Norway 47 23 03 65 50 Sweden 46 8 598 940 00 United Kingdom 44 1753 608 700 iat PowerChain Management ASIA PACIFIC Australia 61 2 9693 9366 New Zealand 64 0 3 343 3314 China 86 21 6361 5599 HK Korea Taiwan 852 2745 6682 India 91 11 4223 2300 Singapore SEA 65 6825 1668 Eaton Powerware PowerChain Management and ePDU are trade names trademarks and or service marks of Eaton Corporation or its subsidiaries and affiliates 2009 Eaton Corporation All Rights Reserved Printed in USA September 2009
20. Electromagnetic circuit breakers to prevent unit through the rear panel cable grip temperature from affecting the trip point CURRENT MONITORING Optional e UL listed branch circuit breakers are 12 NEMA OUTLETS e Front panel display shows current provided where required by UL 60950 1 e Straight blade or twist lock are optional draw of connected equipment standards e Optional cable restraint system with e Two digit display shows current from cable management P N KIT CABLRES 03 0 30 amps with x1 amp accuracy e Monitor will help to prevent system EMI RFI FILTERING Optional overload and ease installation e Filtering is both common mode line ground and differential mode line line e Refer to Chart 4 15 204 Chart 5 30A on page 20 TOTAL SYSTEM CURRENT DRAW MN 2 Optional cable restraint system Refer to page 19 C US LISTED Optional Current Monitoring KIT CABLRES 03 Color Black WWW EPDU COM 1 800 356 5794 1982 design your own part number guide Visit www epdu com for stock configurations 1982 Hi LIT UI a T T Option 1 1 120V 15A input 15A outlets A2 120V 20A input 20A outlets B1 240V 15A input 15A outlets B2 240V 20A input 20A outlets B3 240V 20A input 15A outlets C1 120V 30A input 15A outlets C2 120V 30A input 20A outlets F1 240V 30A input 15A outlets F2 240V 30A input 20A outlets F3 240V 30A input 15A outlets G1 120 240V 30A input 5 15Rs H1 120 240V 30A
21. LTERING e Common Mode line to ground e Differential Mode line to line e Refer to Chart 9 on page 20 Uus LISTED C C Voltage Selectable Input Three Phase 50 60 Hz Voltage Output Single Phase on C13s 50 60 Hz Voltage Output Single Phase on C19s 50 60 Hz Voltage Output Three Phase on IEC 309 50 60 Hz Current Input Per Phase Current Output Per Phase Full Load VA Per Phase Main Listed Breaker Secondary Listed Breakers 1 Each For The C19 Outlets Secondary Listed Breakers 1 Each For A Pair of C13 Outlets IEC 60320 Type C13 Outlets IEC 60320 Type C19 Outlets IEC 309 Outlet EMI RFI Filter Power Cord Length Plug CABLE ASSEMBLY OPTIONS CBL113 10 5 cable 9 long terminated with a NEMA L21 30P at one end and a mating IEC 60309 connector at the other end For use in North America at 120 208 CBL114 5x4 0 mm harmonized cable 9 long with an IEC 60309 connector at both ends For use in Europe at 230 400V EATON CORPORATION ePDU Industrial Products Catalog 120 208V input the output is 208V e 230 400V input the output is 230V 1 IEC 309 3 Phase 30A 120 208V input the output is 120 208V e 230 400V input the output is 230 400V 3 INDICATOR LIGHTS e Power on to PH X Y Z e 120 208V Input the output is 120V e 230 400V input the output is 230V BRANCH CIRCUIT PROTECTION e UL489 Listed Main Disconnect breakers with a long time delay curve provide manual on off switching and automatical
22. PowerChain Management solutions Eaton Industrial Products Catalog Se 1 SECTION 1 SECTION 2 1 CON OH E CEH 1 m oO Fi n SECTION 1 SECTION 2 T PHASE X PHASE Y PHASE 7 eN A EN 23 H J2 DONT I 15 18 OFF m ON at OM OFF 05 E a o E T CAJ CES TOTAL 5 CURRENT 15 4 1 a ON 1 OFF CBs i MH CB 1 ON 2 L or mom i a PAY IN WE E e AVAR ABLE SECONDARY IN USE gt 2 START MAIN POWER CONTROL w EMERGENCY OFF fi TURN TO RESET ELN Powering Business Worldwide Table of Contents Single Phase Systems North American T982 Series isssssssssssssssss HH eme nene nne nene nne r nn nnn nnn 1 Intedioent Power Control IPC 2 0008 STGB ai cdi cies conet n estes gt 4 8 Control IPC3400 2 4188 ardua aE intus tUi 5 Intellgient Power Control POST X X NBES FIO 6 1 91 12 __6______ ____ ________ 7 Single Phase Systems North American 115 10 8 Single Phase Systems International 2365 SOMOS rev pex 9 Three Phase Systems North American TPCA100 Series ssssssssssssse He emen 10 Three Phase Systems North American PC2641 Series HH e ne hn ee nne nnne nennen 11 Three Phase Systems North Americ
23. actory set e All outlets on off Hyperterminal e Set power on sequence to any combination e Individual outlet on off of outlets e Set up and Sequence on off all outlets MODEM ACCESS e Set the MTD timing from 1 second to e Create password and unit address e External modem must be put in auto answer 999 seconds i e 009 9 seconds e Name outlets with 8 character name mode prior to making contact with the IPC e Set up enable or disable Watchdog PASSWORD PROTECTION e Display outlet and Watchdog Timer status EMI RFI FILTERING e Common Mode line to ground e ifferential Mode line to line e Refer to chart 2 on page 20 e For added security a password feature is included which allows the user to assign a three alphanumeric character password Approvals NA NA NA NA Voltage Input Output 50 60 2 120V 120V 100 240V 100 240V Current Input 15A 15A 15A 15A Current Output 12A 12A 12A 12A Full Load VA 1440 VA 1440 VA 1440 VA 2880 VA 1440 VA 2880 VA NEMA Outlets rear panel 5 15R 5 15R IEC 60320 Type C13 IEC 60320 Type C13 EMI RFI Filter 15A 15A 15A 15A Surge Suppression 270V 270V 210V 270V Power Cord Length rear panel 14 3 9 14 3 9 14 3 8 14 3 8 Power Input Plug 5 15 5 15 60320 Type C14 IEC 60320 Type C14 Serial Control RS232 YES YES YES YES Ethernet Control NO YES NO YES WWW EPDU COM 1 800 356 5794 Intellgient Power Control IPC3 4XX Net Series 100V 240V 15A 20A and 30A Single Phase 50 60 Hz
24. an PC975 Series isssssssssssssssss HI e ene nne nnne n nn nennen nnne 12 Three Phase Systems intermational PC302 MT Diosa teat ot tope piter aiu ortas 13 Three Phase Systems International PC2672 enne nennen nnne 14 Non Rackmount Power Distribution Units UPS Extension Systems sssssssse enn 15 0215 100 NOE 16 PRS ONS COON NRI m 17 BCCESSONGS FONET CADO _____ 18 60 0 ___________ ee 19 Environmental Surge Suppression and EMI RFI Filter 20 Single Phase Systems North American T982 Series 120V OR 240 15A 20A AND 30A 50 60HZ E 1 4 a is T982C1 Front T982C1 Rear RACK MOUNTING SPIKE SURGE SUPPRESSION INDICATOR LIGHT e 19 X172 1U x 7 0 e Transient voltage surge suppression e ne blue LED indicator light per e Width is 17 5 without mounting ears prevents damage due to voltage circuit breaker e 16 gauge steel color black fluctuations e Light illuminates when the circuit e Detachable mounting brackets allow for e Metal oxide varistors MOVs are breaker is on and power is present several mounting options utilized line to line or neutral at the input e MOVs provide long life protection POWER INPUT while withstanding large transients BRANCH CIRCUIT PROTECTION e Power cable with plug is attached to With little degradation e
25. e Mating power cables must be ordered separately page 18 e PC3601 has a full range power supply for use at 100 240V EMI RFI FILTERING e Common Mode line to ground e Differential Mode line to line e Filtered inlet isolates noise before entering the system e Refer to chart 4 on page 20 SPIKE SURGE SUPPRESSION e Line to Neutral or Line e Refer to chart 1 on page 20 KIT CABLRES 01 Optional Cable Restraint System refer to page 19 e Push to reset 2 serial 5232 RJ22 connector on the rear 6 RJ22 to DB9 cable included e serial baud rate is 9600 default or 38 400 maximum e Ethernet 10 100 network via RJ45 connector on the rear 6 network cable included e Network setup allows DHCP or any static public private address De INTERFACES Web interface provides a graphic control interface through a Web browser IE Netscape Mozilla e elnet interface provides a text menu control interface with any terminal emulation software e SNMP allows read write capability with trapping e E mail notification system provides e mail alerts or logs showing user activity e Serial interface provides a text menu control interface with any terminal emulation software e FIP utility allows firmware upgrades disable unused interfaces 2 FEATURES Administrator and multiple users can be configured User level access can be limited to specific outlets Unit and outlet names can be configured Outlet groups
26. ence port to any remote port on another LT unit The sequence port activates 4 seconds after the final set of outlets turn on Do not connect to another sequence port NOTE LT units are designed for remote operation only Even when the REMOTE OFF LOCAL switch is set to LOCAL the unit still requires a power request from the remote ports to turn the unit on REMOTE OPERATION Most Eaton units have more than one remote connector Unless labeled as SEQUENCE they are wired in parallel Connection to only one remote connector is required It is recommended that an Eaton control panel be ordered for use with your PDU Connectors are provided for those who wish to wire their own switches or control panels We recommend using 14 AWG wire and not exceeding 50 feet for any remote cable Mating control panels can be seen on our web site at www epdu com If additional remote connectors are needed The female AMP connectors used in our Power Controllers are three pin Part Number 1 480304 0 and four pin Part Number 1 480425 0 and are used with AMP Socket Terminals Part Number 60619 1 The mating male AMP connector is three pin Part Number 1 480305 0 and four pin Part Number 1 480426 0 and are used with AMP male contacts Part Number 60620 1 EATON CORPORATION ePDU Industrial Products Catalog Remote Control Panels N RACK MOUNTED 19 x 1 73 x 2 0 flush mounted 18 GA Steel Painted FED STD 595 26559 l
27. er on Power on to PH X Y and 2 TAL Approvals UL cUL UL cUL UL cUL Voltage Input Three Phase 50 60 Hz 120 208V 120 208V 120 208V Voltage Output 50 60 Hz 120V and 208V 120V and 120 208 120V Current Input Per Phase 30A 30A 30A Current Output Per Phase 24A 24A 24A Full Load VA Per Phase 2880 VA 2880 VA 2880 VA Main Circuit Breaker on off switch 4 Pole 30 30 30 30 4 Pole 30 30 30 30 4 Pole 30 30 30 30 Secondary Circuit Breakers Per Phase 3 2 Pole 20 20 N A 3 1 Pole 20 Unswitched Duplex Circuit Breaker 20A thermal reset 20A thermal reset 15A thermal reset EMI RFI Filter 30A 30A 30A Surge Suppression 210 210 210 NEMA Outlets 8 5 20R and 3 L6 20R 8 5 20R and 3 L21 30R 8 5 15R and 3 L5 30R Power Cord Length Plug 10 5 15 L21 30P 10 5 15 L21 30P 10 5 15 L21 30P rumm n me HT E o This system is designed to be controlled Locally or Remotely via a remote control panel refer to pages 16 17 EATON CORPORATION ePDU Industrial Products Catalog Three Phase Systems International PC302 I MTD 120 208V or 230 400V Three Phase WYE 20A 50 60Hz RACK MOUNTED e 19 x 34 2U x 8 5 with recess mounting e Approximate shipping weight 19 Ib EMI RFI FILTER e Differential Mode e Common Mode e Refer to Chart 2 on page 20 SPIKE SURGE SUPPRESSION e Line to line e Refer to Chart 1 on page 20 VOLTAGE SELECTION SWITCH e Select 120 208V or 230 400V input e 120 208V input w
28. g to detect a fault before it occurs The display shows two digits i with no decimal place The meter is accurate to 1 amp resolution The current meter option is not available on the following is versions G1 and J1 Option 6 Power Cable Length The power distribution unit has either SO SOOW SJT type power cable The length can be specified as 9 feet 15 feet The maximum length allowed by UL standards for an attached power cable is 15 feet For permanent installations exceeding 15 feet a licensed electrician should install a permanent circuit EATON CORPORATION ePDU Industrial Products Catalog 1982 design your own part number guide Option 1 Voltage and Current Configuration The following chart shows the available input output voltage and current configurations Most options have a choice of straight blade or twist lock connectors This selection is made in options 3 and 4 T982 Series Voltage Current Circuit Input Connectors Output Connectors Version Input Output Breakers Straight Blade Twist Lock Straight Blade Twist Lock EE 2 B a o Qe 240V 20A 16A Output epee P 1 120V 30A 2 pole 15A 62 24A Output 11489 L5 30P C2 120V 30A 2 pole 20A 2 24A Output 01489 L5 30P 240V 30A 2 2 pole 15A NA 24A Output 11489 16 30 240V 30A 2 2 pole 20A un C4 24A Output 01489 16 30 240V 30A 2 2 pole 15A a C4 24A Output 11489 16 30 o
29. her E EATON CORPORATION ePDU Industrial Products Catalog Intelligent Power Control Please refer to page 18 for power cable assemblies to match your country specific requirements Power cables must be ordered separately Refer to page 18 for power cable options Approvals UL cUL CE 69 FCC Voltage 50 60Hz 100 240V 100 240V Current Input 20A 0 1201 20A 0 1201 16A 240V 16A 240V Current Output 16A 16A Full Load VA 1920 Q 120V 1920 VA 120V 3840 Q 240V 3840 VA 240V Outlets IEC or NEMA C13 Type C13 Circuit Breaker 20 20A 20 20A EMI RFI Filter 20A 20A Surge Suppression 2101 2101 Power Input Type C20 Inlet Type C20 Inlet Power Cord Ethernet Control NO YES Serial Control 85232 YES YES CHASSIS e 19 x 1 72 1U x 8 5 Weight approximately 12 Ib e Detachable mounting brackets allow for several mounting options NEMA or IEC 320 OUTLETS e PC3401 has 8 IEC 60320 Type C13 Rated by UL CSA 125V 15A Rated by UL CSA VDE 250V 10A e PC3402 has 8 NEMA 5 15R e PC3402 A2 has 8 NEMA 5 20R e PC3402 2756 has 4 NEMA 5 20R and 4 NEMA 5 15R e PC3402 2930 has 8 NEMA 5 15R 11 INDICATOR LIGHTS e Main power to system CB on e ndividual power on to outlets 1 8 e ata acquisition and remote disable REMOTE or LOCAL CONTROL e Serial RS232 port DB9 Male for direct computer or modem connection RS485 input output for strapping up to 1
30. ight texture Gray Optional Painted FED STD 595 26038 Black Remote cable is 15 long RoHS Approximate shipping weight is 5 Ib CORAM ET MODEL REMOTE TYPE HEIGHT RCP100 GRY Standard 1U 1 75 RCP100 BLK Standard 1U 1 75 RCP100 GRY LT Latching 1U 1 75 RCP100 BLK LT Latching 1U 1 75 RCP100 BLK LT a e n ae RCP100 GRY RCP100 Series EMERGENCY POWER OFF EPO e RCP100 GRY Locking 0 EPO button for PDUs with the standard 3 pin remote 1 0 port Turn to reset e RCP100 GRY LT Locking EPO button for PDUs with the latching LT option Turn to reset e Per European requirements there is a yellow square behind the EPO button ON OFF SWITCH e RCP100 GRY 2 position ON OFF switch e RCP100 GRY LT 3 position spring return dial switch for OFF turns unit off and holds off ON puts unit in a standby mode START is a momentary action and powers up the unit Latching LT control panels must be ordered with power distribution units that are latching identified by LT at the end of the part number COLOR Gray Black Gray Black RECEPTACLES None None None None SWITCH EPO 2 position Normally Open 2 position Normally Open 3 position Normally Closed 3 position Normally Closed WWW EPDU COM 1 800 356 5794 17 Accessories Power Cables SUB HRDWARE 032 C19 retaining clamp secures cables to the PDU with cable ties 010 0026 2 5M 1 5mm 3 wire Harmonized 010 0034
31. input 6 15Rs J1 120 240V 30A input 5 15 6 15Rs Option 6 09 9 foot power cable 15 15 foot power cable Option 5 0 No current meter 1 Current meter Option 4 S Straight blade Plug L Locking Plug Option 3 S Straight blade outlets L Locking outlets Option 2 F Filter N No Filter Option 1 Voltage and Current Configuration see next page Option 2 EMI RFI Filtering Choose N for no filtering or F for filtering See Chart 4 15A 20A units Chart 5 30A units on page 20 filtering specifications Option 3 Receptacle Type Choose either straight blade or twist lock style receptacles See the table in Option 1 for a view of the available receptacles Their NEMA designation number refers to the receptacles Option 4 Plug Type Choose either straight blade or twist lock style plug See the table in Option 1 for a view of the available plug styles The NEMA designation number refers to the plug Verify you have the correct type of mating receptacle available at your facility Plug types limit the voltage and current options Option 5 Current Meter This unit is available with or without a front panel digital current reference meter This two segment current reference meter will TOTAL SYSTEM display the current value of the connected load The meter is an AC averaging meter This allows you to properly load your PDU CURRENT DEAN to avoid an overload situation This can also be used for monitorin
32. ith 120V output e 230 400V input with 230V output HS fowl O07 95 EC A CE Approvals Voltage Input Selectable Voltage Output Single Phase Frequency Current Input Per Phase Current Output Per Phase Full load VA Per Phase Main Circuit Breaker IEC 60320 Outlets EMI RFI Filter Per Phase Surge Suppression Power Input LOCAL OFF REMOTE SWITCHING e Local On Off to switched outlets e Off When breaker is on but this switch is in the off mode you will have power to the unswitched outlets only e Remote On Off to switched outlets via a remote control device e latching remote the selection switch 18 wired for Remote Oft Remote There is no local control on the PC302 I LT 14 IEC 60320 TYPE C13 OUTLETS e 120n the front panel switched and 2 on rear panel unswitched REMOTE CONTROL e Remote on off and EPO control EPO overrides remote and local control e Sequence power up additional equipment down line e remote N C momentary start on PC302 I LT only MULTIPLE TIME DELAY MTD e Activated Locally or Remotely PH X powers up followed 4 seconds later by PH Y which is followed 4 seconds later PH Z then 4 seconds later the sequenced remote activates the next e Rated by UL CSA up to 250V 15A system in line e Rated by VDE at 250V 10A each 6 INDICATOR LIGHTS POWER INPUT e Main power on e External terminal block for power input is e Power
33. ly trip with an overload condition 4 REMOTE 1 0 PORTS e 2 Front 2 Rear one on each side is sequence and the other is for remote on off and EPO control The PC2672 is controlled remotely only e Latching remote N C EPO between pins 2 amp 3 momentary start between pins 1 amp 3 120 208 or 230 400V 120V or 230V 208V or 230V 120 208 or 230 400V 30A 24A 2880 VA at 120 208V or 5520 VA at 230 400V 30 30 30A 4 16 16A 6 10A 12 15A 125V or 10A 250V 4 20 125 or 16A 250V 1 3 phase 30A 30A 10 5 5 IEC 60309 3P N PE 30A prm sii This system is designed to be controlled Locally or Remotely via a remote control panel refer to pages 16 17 Non Rackmount Power Distribution Units UPS Extension Systems Voltage Input Output 50 60 Hz Current Input Current Output Full Load VA Circuit Breaker EMI RFI Filtering Surge Suppression NEMA Outlets Power Cord Length NEMA Input Plug LPC120P 120V 30A input and output 6 cable 10 3 terminated with a NEMA L5 30P There are 8 NEMA 5 15R outlets with a 15A thermal reset breaker for each duplex 7 75 W x 3 H x 101 LPC1224 1P 120 240V 30A input with 120V output 6 cable 10 4 terminated with a NEMA L14 30P There are 12 NEMA 5 15R outlets with 15A thermal reset breaker for each duplex 7 75 W x 3 H x 1071 C US LISTED zc 120V 30A 24A 2880 VA 4
34. ower to the unswitched outlets only e Remote Power on or off to the switched outlets via a remote device e latching remote on LI systems has the selection switch wired for Remote Off Remote There is no local control UL cUL UL cUL UL cUL 120 120 240V 15A 20A 15A 12A 16A 12A 1440 VA 1920 VA 2880 VA 5 15R 5 20R 6 15R 15A 20A 15 15A 20A 20A 20A 270V 150V 270V 150V 320V 270V 14 3 9 12 3 9 14 3 9 5 15P 5 20P N A Optional Accessories Ava RCP100 GRY EATON CORPORATION ePDU Industrial Products Catalog _ TPC115 10 D Rear MULTIPLE TIME DELAY MTD Activated locally or remotely oW l outlets power up immediately followed four seconds later by SW II outlets which is followed four seconds later by the sequenced remote 10 port Add MTD after part number i e TPC115 10 A MTD REMOTE 1 0 PORTS UL cUL 120V 30A 24A 2880 VA 5 15R 15 15A 30A 270V 150V 10 3 15 L5 30P ilable 3 front 2 rear see page 16 Remote on off and EPO control EPO overrides remote and local control sequence Power Up additional equipment down line 3rd connector on front panel Latching remote feature N C EPO momentary start Add LT to the part number when the MTD feature is not being used Add LI to the part number when the MTD feature is used UL cUL UL cUL 120V 240V 30A 30A 24A 24A 2880 VA 5760 VA 5 20R 6 15R 15 15A 2 15 15A 30
35. ows up to 10 IPCs 80 outlets to be controlled at one address e Units are connected together via the RS485 IN and OUT connectors UL cUL FCC UL cUL UL cUL 120V 120V 120V 20A 30A 30A 16A 24A 24A 1920 V 2880 VA 2880 VA 5 20R 4 5 20R 4 5 15R 8 5 15R 20A 20 10A 20 10A 20A N A N A 2101 2101 2101 Type C20 Inlet L5 30P L5 30P 10 3AWG 10 10 3AWG 10 YES YES YES YES YES YES UNIT NAME PASSWORD e The IPC comes with a default name which can be changed to any four alphanumeric characters e Optional 3 character password MULTIPLE TIME DELAY MTD e Sequence power up and power down to outlets with a one second time delay factory set e User Programmable Set power on sequence to any combination of outlets Set the MTD timing from 1 second to 999 seconds i e 009 9 seconds AUTO EVENT COMMAND RESPONSE e The IPC will automatically update the status of outlets on or off via serial or telnet SOFTWARE CONTROLS e Multi platform compatible e Control via Terminal Emulation Software e Web interface for browser control COMMANDS AVAILABLE e All outlets on off e Specific outlets on off Set up and sequence on off all outlets Create password and unit address Outlet naming 8 characters oet up enable or disable Watchdog Display outlet and Watchdog Timer status Automatically receive update outlet status whenever there s a change e Auto reboot outlet 1 with a five second delay on restart
36. rated 010 9365 C14 Male to C19 15A 8 foot 11AWG 3 wire 010 0031 320 C14 to CEE7 SCHUKO 250V 10A 1 foot 1 5mm 3 wire Harmonized 010 0032 C14 to NEMA 5 15R 125V 15A 1 foot 16AWG 3 wire af Le amp D bp Cable Restraint and Management TRANSVERSE MOUNTING KIT CABLRES 01 e Prevent downtime and accidental disconnection e Secure cables plugs to PDU e able ties provide highest level of retention Black adjustable bracket versions allow front or rear mounting RoHS KIT CABLRES 01 fits 9 5 deep units 2002 95 c KIT CABLRES 03 fits 7 deep units e Fixed bracket versions allow attachment to rear only KIT CABLRES 08 Black KIT CABLRES 08 VERTICAL MODELS CABLE TRAY RACKMOUNT MODELS CABLE TRAY V42 Series KIT CABLRES 21 IPC34XX Series KIT CABLRES 01 V70A1 Series KIT CABLRES 24 IPC36XX Series KIT CABLRES 01 V70A2 Series KIT CABLRES 24 T17 KIT CABLRES 03 V70AB Series KIT CABLRES 22 T982 Series KIT CABLRES 03 V70Bx Series KIT CABLRES 24 TPC115 10 Series KIT CABLRES 08 V70Cx Series KIT CABLRES 24 T9092 Series KIT CABLRES 08 V70F1 Series KIT CABLRES 24 TPC2104 Series KIT CABLRES 08 V70F2 Series KIT CABLRES 24 TPC2105 Series KIT CABLRES 03 V70F3 Series KIT CABLRES 24 TPC2234 Series KIT CABLRES 08 V70F4 Series KIT CABLRES 24 2235 Series Black 7 KIT CABLRES 03 V70G1 Series V70H1 Series V70J1 Series KIT CABLRES 24 KIT CABLRES 24
37. to phase X Y and 7 on rear panel e 120 208V input selected e High Voltage Cover with attached 230 400V input selected cable plug is available reference below part numbers UL cUL TUV CE 120 208 Vac or 230 400 Vac 120 Vac or 230 Vac 50 60 Hz 20A or 16A 16A 1920 VA or 3680 VA 4 Pole 20A Type C13 20A 210 Terminal Block R e See pages 16 17 for optional control panels UL cUL TUV CE 120 208 Vac or 230 400 Vac 120 Vac or 230 Vac 50 60 Hz 20A or 16A 16A 1920 VA or 3680 VA 4 Pole 20A Type C13 20A 270V Terminal Block REQUIRED CABLE ASSEMBLY OPTIONS CBL100 20A with 12 5 cable 9 long terminated with a NEMA L21 20P DANGER HIGH VOLTAGE for use in North America at 120 208V CBL102 20A with 5x2 5mm Harmonized cable 9 long A plug is not provided so that the end user can provide the country specific plug for use in Europe at 230 400V WWW EPDU COM 1 800 356 5794 13 14 Three Phase Systems International PC2672 Series 120 208V OR 230V 400V Three Phase WYE 30A 50 60 Hz VOLTAGE SELECTABLE RACK MOUNTED 17 IEC OUTLETS e 19 x 5 25 3U x 16 5 with recess 12 C13 Type mounting e Approximate shipping weight 41 Ib 4 C19 Type POWER INPUT e 5 power cable with IEC 309 plug is attached to unit through the front panel cable grip e Unit ships with mating connector to IEC 60309 outlets on front panel EMI RFI FI