IBM SAS Connectivity Card

image

Contents

1. trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the International Business Machines Corporation in the United States other countries or both BladeCenter IBM Redbooks Redbooks logo System Storage The following terms are trademarks of other companies SUSE the Novell logo and the N logo are registered trademarks of Novell Inc in the United States and other countries Enterprise Linux Red Hat and the Shadowman logo are trademarks or registered trademarks of Red Hat Inc in the U S and other countries Microsoft Windows Server Windows and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Linux is a trademark of Linus Torvalds in the United States other countries or both Other company product or service names may be trademarks or service marks of others SAS Connectivity Card ClOv for IBM BladeCenter 11
2. is defined for these storage pools Logical volumes are created from storage pools Volumes can be assigned to specific blades or be shared by several blade servers e Zoning is supported by the SAS RAID controller module However zoning should not be used for regular operations that is for purposes other than troubleshooting e The RAID functionality is supplied by the SAS RAID Controller Modules installed into the BladeCenter S chassis RAID levels supported 0 1 5 10 Maximum volume size is 2 TB Maximum number of volumes is eight per blade server for a total of 48 volumes per chassis One volume can be mapped to all six blades in the chassis e Mixing HDDs of different capacities in a single volume is supported However the total volume size is aligned with the size of the smallest HDD and excess space on larger sized HDDs is not used e Both SAS and Near line SAS NL SAS hot swap HDDs are supported and intermixing SAS NL SAS drives is supported as well However each storage pool must have hard disks of the same type that is SAS or NL SAS SATA drives are not supported by the SAS RAID Controller Module e Global hot spare drives are supported The drive designated as a hot spare should be as large as or larger than other drives in the system e Blade boot from logical volume is supported e Path failover is supported with IBM Subsystem Device Driver Device Specific Module SDD DSM for Windows and Device Mapper Multi
3. ul ye Ci Redbooks Technote SAS Connectivity Card CIOv for IBM BladeCenter IBM BladeCenter at a glance guide The SAS Connectivity Card ClOv for IBM BladeCenter is an expansion card that offers the ideal way to connect the supported BladeCenter servers to a wide variety of SAS storage devices Built on proven 3 Gbps full duplex SAS technology the SAS Connectivity Card can connect to the IBM System Storage DS3200 from the BladeCenter E or H chassis and to multiple Disk Storage Modules in the BladeCenter S The card routes the pair of SAS channels from the blade s onboard SAS controller to SAS switches installed in the BladeCenter chassis This card is installed into the ClOv slot of the supported blade server It provides connections to SAS modules located in bays 3 and 4 of supported BladeCenter chassis The SAS Connectivity Card ClOv is shown in Figure 1 Figure 1 SAS Connectivity Card ClOv for IBM BladeCenter Did you know The adapter is based on the PCI Express bus which can be thought of as a high speed serial replacement of the older technology Its use offers many benefits including higher speeds and the ability to send and receive data at the same time When using the ClOv adapter you can simultaneously use a CFFh adapter to enable more types of I O to supported blade servers such as the HS22 when installed in the IBM BladeCenter H chassis The innovative design of the ClOv adapter works with the CFFh adapte
4. 00 to 7 000 ft e Relative humidity 8 to 80 e Maximum altitude 2 133 m 7 000 ft Supported servers and I O modules The SAS Connectivity Card ClOv is supported in the IBM BladeCenter servers listed in Table 2 Table 2 Supported servers Part 3 i i Expansion card number i 4 HS 1 H521 XM SAS Connectivity Card 43wW4068 N NIN TYYINININININITNIN TY Y NIN ClOv See IBM ServerProven for the latest information on the expansion cards supported by each blade server type http ibm com servers eserver serverproven compat us SAS Connectivity Card ClOv for IBM BladeCenter 2 ClOv expansion cards are installed in the ClOv slot in supported servers such as the HS22 as shown in Figure 2 ClOv expansion card PCI Express connector CFFh expansion card for further expansion Figure 2 Location of the ClOv slot in the IBM BladeCenter HS22 The SAS Connectivity Card ClOv requires that a supported I O module is installed in bay 3 and bay 4 depending on the configuration of the chassis in which the cards and servers are installed Table 3 lists the supported I O modules Table 3 I O modules supported with the SAS Connectivity Card ClOv I O module Part number UF amp H b qi g k SAS Connectivity Module 39Y9195 SAS RAID Controller Module 43W3584 7 BladeCenter H aO BladeCenter T E BladeCenter HT LJ g a Ra a v L on SAS Connectivity Card ClOv for IBM B
5. dules are used e Mixing HDDs of different capacities in a single volume is supported However the total volume size is aligned with the size of the smallest HDD and excess space on larger sized HDDs is not used e Supported combinations of volumes include e Two IM or IME volume per blade server SAS Connectivity Card ClOv for IBM BladeCenter 6 e One IM or IME volume and IS volume per blade server e Two lS volumes per blade server e Each blade with an SAS expansion card has access to its assigned HDDs in both DSMs even if only one SAS Connectivity module is present Potentially all 12 drives in both DSMs can be assigned to the single blade server However only 10 HDDs can be used in a single volume You can create either two volumes to utilize the capacity of all drives or designate the remaining two drives as hot spares e Both SAS and SATA hot swap HDDs are supported and intermix of SAS SATA drives is supported as well However each volume must have hard disks of the same type that is SAS or SATA e External disk storage attachments are not supported BladeCenter S integrated storage advanced RAID functionality with shared storage The configuration shown in Figure 5 connects the SAS Connectivity Card ClOv installed in each blade server to the integrated BladeCenter S storage using two IBM BladeCenter S SAS RAID Controller Modules in the BladeCenter S chassis In this configuration the RAID functionality is provid
6. ed by the RAID Controller Modules in the BladeCenter chassis and not by the RAID controller that is on the blade server s system planar IBM BladeCenter chassis a T PA Bi i K 9 Q i F e IBM BladeCenter server Rear view Front view Figure 5 IBM BladeCenter S with advanced RAID functionality The parts used in this configuration are listed in Table 6 SAS Connectivity Card ClOv for IBM BladeCenter 7 Table 6 Components used when connecting the SAS Connectivity Card ClOv to the integrated BladeCenter S storage with support for shared storage Diagram Part number Machine Description Quantity reference type BladeCenter HS22 or other supported server 43W4068 SAS Connectivity Card ClOv for IBM BladeCenter server 433584 IBM BladeCenter S SAS RAID Controller Module 43W3581 IBM BladeCenter S 6 Disk Storage Module DSM Take these considerations into account when planning BladeCenter S advanced shared storage implementations e Every blade requiring integrated storage connectivity must have one SAS Connectivity Card installed e Atleast one DSM must be installed into the BladeCenter S chassis a maximum of two DSMs are supported in one chassis The IBM BladeCenter S does not ship with any DSMs as standard e Two SAS RAID Controller Modules must be installed into the BladeCenter S chassis e The SAS RAID Controller Module creates storage pools or arrays and the RAID level
7. ent to IBM for the purposes of developing using marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM therefore cannot guarantee or imply reliability serviceability or function of these programs Copyright International Business Machines Corporation 2009 All rights reserved Note to U S Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp SAS Connectivity Card ClOv for IBM BladeCenter 10 This document was created or updated on May 15 2009 Send us your comments in one of the following ways e Use the online Contact us review form found at ibm com redbooks e Send your comments in an e mail to redbook us ibm com e Mail your comments to IBM Corporation International Technical Support Organization Dept HYTD Mail Station PO99 2455 South Road Poughkeepsie NY 12601 5400 U S A This document is available online at http www ibm com redbooks abstracts tips0 701 html Trademarks IBM the IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms may also be registered or common law trademarks in other countries A current list of IBM
8. ing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the s
9. ion 1726 22X is the only supported storage server The DS3200 single controller version is not Supported e Each SAS connectivity module must be attached to one of the controllers in the DS3200 but not to both That is having redundant paths from a single SAS Connectivity Module to both DS3200 controllers is not supported e Upto 48 hot swap 3 5 disk drives with SAS or SATA interface are supported Up to three EXP3000 expansion units are supported The intermixing of SAS and SATA drives is supported Note however that you cannot use both SAS and SATA drives in the same array e DS3200 can be attached to up to 14 blade servers one chassis A Partition Expansion License is required to support more than four host server blades e RAID levels 0 1 10 3 5 and 6 are supported by DS3200 e Amaximum of 48 drives is supported in a single RAID 0 1 and 10 array e Amaximum of 30 drives is supported in a single RAID array for other RAID levels 3 5 and 6 e The logical volume size can be greater than 2 TB e One SAS host interface per controller is supported The optional DS3200 SAS 2 port Daughter Card 39R6509 feature code 4836 is not supported in this configuration e Optional FlashCopy and VolumeCopy options are available BladeCenter S integrated storage basic RAID functionality The configuration shown in Figure 4 connects the onboard SAS RAID controller of support blade servers to the integrated BladeCenter S storage using
10. ladeCenter 3 Popular configurations This section illustrates three ways in which the SAS Connectivity Card ClOv can be used in configurations External DS3200 attachment Figure 3 shows the supported topology for the SAS Connectivity Card ClOv and an IBM System Storage DS3200 storage server connected to the BladeCenter E or BladeCenter H chassis In this configuration the RAID functionality is provided by the external DS3200 storage server ss ae ae IBM System Storage Figure 3 IBM BladeCenter connected to an external IBM System Storage DS3200 storage solution The parts used in this configuration are listed in Table 4 Table 4 Components used when connecting the SAS Connectivity Card ClOv to external disk storage Part number Machine Description Quantity type BladeCenter HS22 or other supported server 1 to 14 43W4068 SAS Connectivity Card ClOv for IBM BladeCenter 1 per server 8677 or 8852 BladeCenter E or BladeCenter H This configuration will also require cabling between the chassis and the storage server and between the storage server and expansion units The cable part numbers are not listed in the table SAS Connectivity Card ClOv for IBM BladeCenter 4 Take these considerations into account when planning external SAS based disk storage server attachments e DS3200 is supported for both data storage and boot from SAN when attached to the supported BladeCenter chassis e DS3200 Dual Controller vers
11. path DMM for Red Hat Novell SUSE Linux e Currently external storage attachments are not supported SAS Connectivity Card ClOv for IBM BladeCenter 8 Supported operating systems The SAS Connectivity Card ClOv supports the following operating systems Microsoft Windows Server 2008 Web x64 and x86 Editions Microsoft Windows Server 2008 Standard x64 and x86 Editions Microsoft Windows Server 2008 Enterprise x64 and x86 Editions Microsoft Windows Server 2008 Datacenter x64 and x86 Editions Microsoft Windows Server 2003 and 2003 R2 Standard x64 and x86 Editions Microsoft Windows Server 2003 and 2003 R2 Enterprise x64 and x86 Editions Microsoft Windows Server 2003 and 2003 R2 Datacenter x64 and x86 Editions Microsoft Windows Small Business Server 2003 and 2003 R2 Standard Edition Microsoft Windows Small Business Server 2003 and 2003 R2 Premium Edition Microsoft Windows Server 2003 Web Edition Red Hat Enterprise Linux 5 Server Edition SUSE Linux Enterprise Server 10 for x86 SUSE Linux Enterprise Server 10 with Xen for AMD64 EM64T SUSE Linux Enterprise Server 10 with Xen for x86 See IBM ServerProven for the latest information on the specific versions and service packs supported http ibm com servers eserver serverproven compat us Select the blade server and then select the expansion card to see the supported operating systems Related publications For more information refer to these documents SAS Connectivity Card ClO
12. r to support this combination Serial Attached SCSI SAS is a point to point architecture in which all storage devices connect directly to a SAS port rather than sharing a common bus as traditional SCSI devices do Point to point links increase data throughput and improve the ability to locate and fix disk failures SAS architecture solves the parallel SCSI problems of clock skew and signal degradation at higher signaling rates SAS Connectivity Card ClOv for IBM BladeCenter 1 Part number information The part number to order this card is shown in Table 1 Table 1 Ordering part number and feature code SAS Connectivity Card ClOv for IBM BladeCenter 43W4068 1041 The part number includes the following items e One SAS Connectivity Card ClOv for IBM BladeCenter e The Documentation CD that contains the SAS Connectivity Card ClOv for IBM BladeCenter Installation and User s Guide e The 6M Important Notices document Features SAS Connectivity Card ClOv has the following features e ClOv form factor e Provides external connections for the two SAS ports of blade server s onboard LSI 1064e disk storage controller e Support for two full duplex SAS ports at 3 Gbps maximum per channel e Support for SAS SSP and SMP protocols Operating environment The expansion card is supported in this environment e Temperature e 10 to 35 C 50 to 95 F at 0 to 914 m 0 to 3 000 ft e 10 to 32 C 50 to 90 F at 914 to 2 133 m 3 0
13. server only and the blade itself sees this physical disk or disks as its own hard disk drives connected via SAS Connectivity Card That is there are no LUNs storage partitions and so forth as in shared storage systems Instead each blade has its own set of physical disks residing in DSM or DSMs e The SAS Connectivity Module controls disk assignments by using zoning like techniques which results in the SAS module maintaining single isolated dedicated paths between physical HDDs and the blade server Configuration of HDD assignments is done by the administrator and the administrator uses predefined templates or creates custom configurations e The RAID functionality is supplied by the onboard disk controller in the blade servers RAID levels supported by onboard RAID controller on blade itself are e RAID O Integrated Striping IS e RAID 1 Integrated Mirroring IM e RAID 1E Integrated Mirroring Enhanced IME e The maximum number of drives supported by the IM volume is two plus one optional global hot spare The IME volume supports up to ten HDDs plus two optional hot spares The IS volume supports up to ten HDDs The IS volume does not support hot spare drives e When creating a RAID 1 array we recommend you span both disk storage modules This maximizes availability of data in the event that one of the paths to the disks is lost because there is only one connection to each disk storage modules in case two SAS Connectivity Mo
14. the SAS Connectivity Card ClOv in each server and IBM SAS Connectivity Modules in the BladeCenter S chassis In this configuration the RAID functionality is provided by the RAID controller on the system planar of the blade server IBM BladeCenter chassis IBM BladeCenter server Rear view Front view Figure 4 IBM BladeCenter S with basic RAID functionality The components used in this configuration are listed in Table 5 SAS Connectivity Card ClOv for IBM BladeCenter 5 Table 5 Components used when connecting the HS22 onboard RAID controller to the integrated BladeCenter S storage Part number Machine Description Quantity type BladeCenter HS22 or other supported server 43W4068 SAS Connectivity Card ClOv for IBM BladeCenter server a e Take these considerations into account when planning BladeCenter S basic local storage implementations e Every blade requiring integrated storage connectivity must have one SAS Connectivity Card ClOv installed e Atleast one BladeCenter S Disk Storage Module DSM must be installed into the BladeCenter S chassis a maximum of two DSMs are supported in one chassis The IBM BladeCenter S does not ship with any DSMs as standard e Atleast one SAS Connectivity Module must be installed into the BladeCenter S chassis A maximum of two SAS modules are supported for redundancy and high availability purposes e Each physical hard disk drive in any DSM can be assigned to the one blade
15. uppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confirm the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products This information contains examples of data and reports used in daily business operations To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Any performance data contained herein was determined in a controlled environment Therefore the results obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurement may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy modify and distribute these sample programs in any form without paym
16. v Installation and User Guide http www ibm com support docview wss uid psg 1MIGR 5079707 IBM US Announcement Letter for the SAS Connectivity Card ClOv http ibm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlifid 89 7 ENUS 109 101 IBM BladeCenter Interoperability Guide http www ibm com support docview wss uid psg 1MIGR 5073016 IBM Redbooks publication BM BladeCenter Products and Technology http www redbooks ibm com abstracts sg24 523 html SAS Connectivity Card ClOv for IBM BladeCenter Notices This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this document in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product program or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writ

Download Pdf Manuals

image

Related Search

Related Contents

Sharp PG-LW2000 Specification Sheet  Untitled - Vaterra  MANUAL - Temporizador - Tm  AFP_AFC_JT_Installation_and_Operating_Instructions_0831_2046  設計図(PDF:673KB)  Trane Round In/Round Out Installation and Maintenance Manual  Ilumiline 21 IP Optic Series  Capitolato - Rete Civica di Trieste  Siemens SITRANS FC410 Coriolis Mass Flowmeter with Modbus    