1. may cause lung damage It is attributed to lung overloading a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval Use of this product as intended does not result in inhalation of excessive dust Carcinogenicity Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation study in rats However there was not observed the incidence of tumors on the test results on dermal or oral studies Also 2 years inhalation study using a typical toner containing carbon black showed no association between toner exposure and animal tumors Section 4 First Aid Measures Gargle with water Remove to fresh air if effects In case of contact immediately flush eyes Inhalation occur Get medical attention if needed Eye Contact with water for 15 minutes Get medical attention if needed Skin Contact Wash with soap and water Ingestion Dilute stomach contents with several glasses of water Get medical attention Section 5 Fire Fighting Measures Suitable extinguishing media COs dry chemical foam or water Fire Fighting Instructions Generally by sprinkling or extinguisher Special protective equipment for fire fighters none UEL n a LEL n a Burning rate N a your document management partner MATERIAL SAFETY DATA SHEET Page2 of 3 CP 322 Section 6 Accidental Release Measures Spill leak Procedures If spilled sweep up using an approved toner
2. product is not a dangerous substance One should however observe the usual precautionary measures for dealing with chemicals MATERIAL SAFETY DATA SHEET Page 3 of 3 CP 322 Section 14 Transportation Information International regulations RID ADR Not applicable ICAO TI ATA DGR Not applicable DOT 49 CFR Not applicable UN Classification Number Not applicable ADNR Not applicable IMDG Code Not applicable Specific precautionary transport measures Avoid direct sunlight Do not keep over 35 C 95 F Specific material to avoid None in normal use Product Label 5218 Black Toner Section 15 Regulatory Information Regulation No information available Section 16 Miscellaneous Information Judgment as to the suitability of information contained herein for user s purposes is the responsibility of the purchaser Therefore although reasonable care has been taken in the preparation of this information Lanier Worldwide Inc extends no warranties makes no representations and assumes no responsibility as to the accuracy or suitability of such information for application to user s intended purposes or for consequences of its use All materials may present unknown hazards and should be used with caution Although certain hazards are described herein we do not guarantee that these are the only hazards that exist Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product und
3. vacuum with a 0 5 micron filter or smaller such as the Atrix AAA Toner Vacuum or 3M Toner Vacuum Use of a vacuum cleaner not rated for toner particles could result in a fire or personal injury Remove residue with soap and cold water Miscellaneous Keep product out of sewers and watercourses Personal protection Avoid inhalation of dust Section 7 Handling and Storage Special Handling Cleanse skin after contact before breaks or meals and end of workday Do not handle in areas where the wind blows Minimize the breathing of dust Special Storage Avoid direct sunlight Keep out of reach of children Store in a cool dry place Below 35C 95F Section 8 Exposure Control and Personal Protection Information Respiratory Protection none required under normal use Hand Protection none required under normal use Eye Protection none required under normal use Skin Protection none required under normal use Section 9 Physical and Chemical Properties CHARACTERISTICS Appearance Black Melting point N a Form Powder Vapor pressure N a Odor Slight plastic odor Vapor density N a Solubility in Water Insoluble Evaporation rate N a Specific gravity N a Boiling point N a Density 1 2 g cm Volatiles N a Section 10 Stability and Reactivity Conditions to avoid None Materials to avoid None Hazardous decomposition products Will not occur Stability Stable Section 11 Toxicological Information Ames test Negative Acute ora
4. LANIER A RICOH COMPANY Lanier Worldwide Inc 2300 Parklake Drive NE Atlanta GA USA 30345 2979 MATERIAL SAFETY DATA SHEET Emergency Telephone 800 551 3087 Section 1 Chemical Product and Company Information Identity 5218 Toner Photoconductor MSDS No CP 322 Cartridge Toner Product ID 480 0031 Issued 01 05 2006 Supersedes 01 23 2003 Synonyms Date 01 05 2006 amp Common Toner Photoconductor Cartridge for Prepared by EH amp S Department 770 496 9500 Names Lanier 5218 Approved by Larry Choskey Manager CEH amp S Uses Lanier 5218 Chemical Formula Mixture Section 2 Composition Information on Ingredients PERCENT CAS No EXPOSURE LIMITS SOURCE Polyester resin 45 Confidential Not listed n a Styrene acrylic polymer 11 25767 47 9 Not listed n a Magnetite 40 1309 38 2 Not listed N a Wax 3 8015 86 9 Not listed N a Silica 1 7631 86 1 PEL as the product 15mg m total dust 5mg m respirable dust TLV as the product 10mg m total dust 5mg m respirable dust Section 3 Hazards Identification HMIS Rating FLAMMABILITY 1 HEALTH 1 REACTIVITY 0 SPECIAL none Health Hazards Acute Chronic Immediate and Potential Minimum irritation to respiratory tract may occur as with exposure to any non toxic dust May cause gasping if inhaled Inhalation should be avoided May cause temporary eye discomfort Health Hazards of Long Term exposure Chronic Prolonged inhalation of excessive dust
5. er normal conditions On the basis of the data available to us this product is not a dangerous substance One should however observe the usual precautionary measures for dealing with chemicals
6. l toxicity Rat gt 5000 mg kg Special effects Carcinogenicity In 1996 the IARC reclassified Carbon Black as a Group 2B carcinogen possible human carcinogen This evaluation is given to carbon black for which there is inadequate human evidence but sufficient animal evidence The latter is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung Studies performed in animal models other than rats have not demonstrated an association between carbon black and lung tumors Moreover 2 years cancer bioassay using a typical toner preparation containing carbon black did not demonstrate an association between toner exposure and tumor development in rats Teratogenicity Not available Section 12 Environmental Ecological Information Bioaccumulation Not known in bioaccumulation Environmental Degradability Not known Section 13 Disposal Consideration Used toner should be disposed of under conditions that meet all federal state and local environmental regulations Disposal regulations vary from locality to locality therefore consult your local Lanier office or the EPA to determine the proper method for disposal Do not incinerate loose or spilled toner Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under normal conditions On the basis of the data available to us this