        Tripp Lite SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial
         Contents
1.  accessory   e CE  GOST  SASO listed    Specifications    General Info    OUTPUT    Nominal Output Voltage s  220V  230V  240V   Supported   Nominal Voltage Details 230v nominal inverter output voltage  Frequency Compatibility 50   60 Hz    Output Voltage Regulation  Line 17    8   Mode   Output Voltage Regulation  Battery     5   Mode     Output AC Waveform  Battery Mode    Pure Sine wave    2 9    Tripp Lite  ERRON  35th Street  Chicago  IL 60609 USA    Telephone  773 869 1234    www tripplite com       INPUT    Nominal Input Voltage s  Supported   230V AC    UPS Input Connection Description Hardwire input supports International 230V input  L  N  PE     Input Phase Single Phase    BATTERY    Full Load Runtime  min   8 5 min   3750w   Half Load Runtime  min   20 min   1875w   Expandable Battery Runtime Extended runtime supported via optional external battery packs    External Battery Pack Compatibility BP48V24 2U  limit 1   BP48V60RT 3U  multi pack compatible   BP48V27 2US  multi pack compatible     Battery Recharge Rate  Included Less than 4 hours from 10  to 90   typical  full load discharge   Batteries    Internal UPS Replacement Battery     Cartridge RBC94 3U  quantity 3     Battery Access Front panel battery access door  Battery Replacement Description Hot swappable  user replaceable batteries    VOLTAGE REGULATION    Voltage Regulation Description Automatic voltage regulation  AVR  maintains line power operation with an input voltage range of 170 to 282  Overvoltage Co
2. 30v output over an input range of 170 282V  Supports hardwire input  Includes C19 and  C13 output receptacles  Network grade AC surge and noise suppression  Network management interfaces support communications via USB  DB9 serial and  SNMPWEBCARD slot  Supports simultaneous detailed monitoring of equipment load levels  self test data and utility power conditions via all 3 network  interfaces at once  Includes PowerAlert monitoring software and complete cabling  Emergency Power Off  EPO  interface  3 stage metered current monitoring  and battery charge status LEDs  Utility power and voltage regulation LEDs  Audible alarm  Self test  4 post rackmount installation accessories included   2 9USTAND tower kit and 2POSTRMKITWM two post rack mounting accessories available  Field replaceable  hot swappable internal batteries and external    battery packs     Features  e 5000VA 3750 watt max  output power capacity compatible with International 230V input voltage    3U rack tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 635mm   25in    e Protects sensitive networking equipment from blackouts  voltage fluctuations and transient surges   e Line Interactive Automatic Voltage Regulation  AVR  corrects 230V nominal input from 170 to 282VAC to usable 230V levels without consuming battery  power   e AVR circuits boost undervoltages from 170 to 199V by 12  and reduce overvoltages from 245 to 282V by 12    e Network interfaces support simultaneous communic
3. Tripp Lite    1111 W  35th Street     Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com       SmartPro 230V 5kVA 3 75kW Line Interactive Sine highlights eo  Wave UPS  Extended Run  SNMP  Webcard  3U   a ters  Rack Tower  USB  DBO Serial 3U rack tower UPS  Sine wave    output   MODEL NUMBER  SMX5000XLRT3U e 230V nominal output during  brownouts to 170V and  overvoltages to 282V   e USB  Serial  EPO  amp  optional  SNMP Web card monitoring  options   e 3U all in one chassis  98   efficiency   e Hardwire input  8 C13  amp  3 C19    outlets    Package Includes  e SMXS5000XLRT3U UPS system    e PowerAlert Software and Cabling       e Mounting hardware for 4 post    rackmount installation    Description    e Warranty information  5000VA line interactive UPS system for server  network and telecommunications equipment  5kVA UPS with Seam Be  internal batteries installs in only 3 rack spaces with a depth of only 635mm   25 inches  High 98  line power  efficiency rating reduces energy consumption and BTU heat output  Expandable battery runtime with optional BP48V24 2U  limit 1   BP48V60RT 3U   multi pack compatible  and BP48V27 2US  multi pack compatible  external battery packs  Uninterruptible Power Supply  UPS  switches to battery derived AC  output during power failures and extreme voltage variations  Line interactive Automatic Voltage Regulation  AVR  offers voltage boost during brownouts and  voltage reduction during overvoltage conditions to maintain regulated 2
4. ations via USB  DB9 serial or contact closure and SNMPWEBCARD slot   e Included PowerAlert UPS monitoring software supports safe unattended shutdown  monitoring and control via local connected servers  plus any number  of additional servers over IP    e Communications ports support on battery  low battery  power restored  AC voltage  DC voltage  output current monitoring  battery charge current  battery    1 5    Tripp Lite    ERRON  35th Street   amp  Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com       capacity  internal UPS temperature  AC line frequency  timed inverter shutoff and activate self test   e Built in Emergency Power Off  EPO  interface with cable   e Sine wave output in AC and battery mode   e Expandable runtime with optional BP48V24 2U  limit 1   BP48V60RT 3U  multi pack compatible  and BP48V27 2US  multi pack compatible  external  battery packs   e Half full load runtime of 27 10 minutes with internal batteries   e Includes 11 output receptacles  3 C19 8 C13    e Hardwire input AC connection   e 3 stage metered LEDs offer current monitoring and battery charge level   e Mains power and voltage regulation LEDs offer at a glance power status information   e Front panel switches support self test and alarm cancel functions   e Included adjustable mounting rails support installation in 4 post 19 inch racks   e Supports 2 post rackmount installation with optional 2POSTRMKIT accessory   e Supports upright tower placement with optional 2 9USTAND
5. ear limited warranty    a Warranty Period  Puerto 2 year limited warranty       2015 Tripp Lite  All rights reserved  All trademarks are the sole property of their respective owners  Tripp Lite has a policy of continuous improvement        Specifications are subject to change without notice  Photos may differ slightly from final products     9 95    
6. ng Dimensions  hwd   in     11 3 x 23 x 31 5    UPS Shipping Dimensions  hwd   28 6 x 58 4 x 80    Shipping Weight  Ibs   1    82  Shipping Weight  kg  82 6    Cooling Method Fans    ENVIRONMENTAL    0 to 95   non condensing  2    AC Mode BTU   Hr   Full Load     AC Mode Efficiency Rating  100  o  98   Load     COMMUNICATIONS    Communications Interface USB  DB9 Serial  EPO  emergency power off   Slot for SNMP Web interface  Network Monitoring Port Description   Supports detailed monitoring of UPS and site power conditions    PowerAlert Software Included    Q  3  _     N  oO    Communications Cable USB and DB9 cabling included    WatchDog Compatibility Supports Watchdog application  OS and hard reboot restart options for remote applications    4 5    Tripp Lite   1111 W  35th Street  Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com    LINE   BATTERY TRANSFER    Transfer Time 7 ms  AC to Battery   1 ms  Battery to AC  typical    Low Voltage Transfer to Battery  Power  Setpoint     Power  Setpoint     SPECIAL FEATURES    Grounding Lug Back panel grounding lug    Cold Start  Startup in Battery Mode l      During a Power Failure  Cold start operation supported   High Availability UPS Features Hot swappable batteries   Green Energy Saving Features Greater than 95  efficiency   GREEN UPS    CERTIFICATIONS    UPS Certification Details Class A  EMI     WARRANTY  Product Warranty Period 2 year limited warranty   International     Product Warranty Period  Mexico  2 y
7. rrection Input voltages between 245 and 282 are reduced by 12   Undervoltage Correction Input voltages between 170 and 199 are boosted by 12     USER INTERFACE  ALERTS  amp  CONTROLS       Switches 2 Switches control off on power status and alarm cancel self test operation    Power fail alarm can be silenced using alarm cancel switch  once silenced  alarm will re sound to indicate    Alarm Cancel Operation low battery status       Audible Alarm Audible alarm indicates power failure  overload and low battery conditions    LED Indicators 5 LEDs indicate line power  battery power  overload  voltage regulation and battery low replace status    SURGE   NOISE SUPPRESSION    UPS AC Suppression Joule Rating 480    UPS AC Suppression Response    Instantaneous  Time    EMI   RFI AC Noise Suppression Yes    Tripp Lite  ieee YY  35th Street  Chicago  IL 60609 USA    Telephone  773 869 1234    www tripplite com       PHYSICAL    Installation Form Factors Supported 4 post 19 inch rackmount  with Included Accessories  Installation Form Factors Supported   2 post rackmount  22POSTRMKITWM   Tower  2 9USTAND   with Optional Accessories    Primary Form Factor Rackmount  UPS Power Module Dimensions 594755   hwd  in     UPS Power Module Dimensions 13 3 x 44 4 x 635   hwd  cm    Installed Whole System Maximum  Rack Depth  in      Installed Whole System Maximum 63 5  Rack Depth  cm     Rack Height  U Spaces     UPS Power Module Weight  Ibs   143         UPS Power Module Weight  kg  64 9  UPS Shippi
    