Home
Silverstone OP1200
Contents
1. Q E i Kai o fe a gt e o gt Ww 0 50 100 200 300 500 600 700 800 900 10001080 12V power watts 2 4 5V standby voltage The 5Vsb is on whenever the AC power is present 2 5 DC Output Voltage Ripple and Noise Output Voltage Ripple amp Noise Max Units 5V 50 mV 12V 120 mV 12V 120 mV 3 3V 50 mV 5Vsb 50 mV Note 1 The measurements should be made by crossing a 10uF electrolytic and a 0 1uF ceramic disk capacitors at each output with measuring bandwidth from DC to 20 MHz If ambient temperature is under 20 C or over 30 C the AC input should be nominal input 2 6 Total Output Power MAX Units 1200 Watts 2 7 Remote ON OFF Control The power supply outputs shall be enabled with an active low TTL signal When TTL signal is low the DC outputs are to be enabled When TTL signal is high or open circuited the DC outputs are to be disabled Electronic means or a mechanical switch may activate the TTL signal After the TTL signal is active high must wait for 3 seconds before active low again 2 8 Power Sequence AC IN a SE a n Pma 2 9 Power On Time T1 MAX Units 1000 ms a oPi200 A 2 10 Rise Time T2 MIN MAX Units 1 0 50 ms 2 11 Power Good Delay Time T3 MIN MAX Units 100 500 ms
2. 2 12 Power Good Rise Time T4 The test environment is 25 C amp full load condition nominal input 2 13 MAX Units 10 ms Hold Up Time T5 MAX Units 16 ms 2 14 The test environment is 25 C amp full load condition nominal input Power Fail Signal T6 Power good signal shall go to a down level 1ms before 5V output voltage falls below the regulation limits during PS ON signal pull high MIN Units 1 0 ms 3 Protections 3 1 Over Voltage Protection When the DC outputs 5V 12V 3 3V have over voltage condition the power supply shall provide latch mode over voltage protection DC output MAX Unit 12V 15 5 V 5V 6 5 V 3 3V 4 6 V Short Circuit Protection A short circuit placed to ground shall cause no damage or power supply shall be shutdown The contact resistance is 0 05 ohm when the outputs short circuit Protection Reset When the power supply latches into shutdown condition due to a fault on an 5V 3 3V 12V output OVP UVP the protection shall reset after the fault has been removed use remote on off control or recycle the AC power again for a typical of 5 seconds 3 4 Over Shoot Any output overshoot at turn on shall be less than 15 of the nominal output value with resistive load as described in sec 2 1 3 5 Over Power Protection At 115 230Vac input the power supply will shut d
3. SILVERSTONE Designing Inspiration OP SERIES OP1200 The power to lead Powerful single 12V rail with 90A 1200W continuous power output rated up to 50 C Efficiency greater than 80 at 20 100 loading Japanese primary capacitors Dual PCI E 8pin amp Six PCI E 6pin Dual EPS12V 8pin amp six SATA connectors Silent running 135mm ball bearing Fan Support ATX 12V 2 3 amp EPS 12V SPECIFICATION SilverStone OP1200 ATX12V 2 3 SWITCHING POWER SUPPLY WITH ACTIVE PFC PS 2 1200 1 Input Requirements 1 1 Input Voltage The power supply shall be operated at universal input voltage defined in the following table Input Voltage MIN NOM MAX Voltage 90 100 240 264 1 2 Frequency The input frequency range is from 50Hz to 60Hz 1 3 Inrush Current The max inrush current is 160A for 230VAC 90A for 115VAC 1 3 1 Cold Start Conditions Limits No component over stress or 115 230VAC full load damage should occur to the power 25 C ambient supply Input fuse shall not blow 1 3 2 Warm Start Conditions Limits Turn off at 132 264VAC full load for 1 No component over stress or sec then turn on at the peak of the damage should occur to the power input voltage cycle at 25 C ambient supply Input fuse shall not blow 1 4 AC Input Current AC Input MAX Units 100 240V 9 18 AMPS 1 5 Efficiency The power supply efficiency greater than 80 at normal input volt
4. age 115 230Vac input voltage Dy oPi200 A 2 Output Requirements 2 1 Output Regulations Output Voltage Range MIN Nominal MAX Unit 5V 5 4 75 5 00 5 25 Volts 12V 5 11 40 12 00 12 60 Volts 12V 10 10 80 12 00 13 20 Volts 3 3V 5 3 14 3 30 3 46 Volts 5Vsb 5 4 75 5 00 5 25 Volts Note 1 The above voltage range should also include ripple and noise 2 The output voltage should be measured at the terminals of output connector 2 2 DC Load Requirements Output Voltage MIN NOM MAX Unit 5V 1 0 20 40 AMPS 12V 4 0 40 90 AMPS 12V 0 0 0 4 0 8 AMPS 3 3V 1 0 15 40 AMPS 5Vsb 0 1 2 4 AMPS Note 1 The maximum continuous total DC output power shall not exceed 1200 Watts 2 The maximum continuous combined load on 5V and 3 3V outputs shall not exceed 250 Watts 3 The maximum continuous combined load on 12V outputs shall not exceed 1080 90A Watts 4 The maximum continuous combined load on 5V 3 3V and 12V outputs shall not exceed 1180 Watts 2 3 Cross Regulation The DC loads shall remain within the ranges specified in 2 2 DC Load Requirements and the DC output voltages also shall remain within the regulation ranges specified in 2 1 Output Regulation when measured at the load end of the output connectors 1200W Cross Regulation 5V rail 3 3V vs 12V 3 3V amp 5V power a
5. led out by your salesperson at the time of purchase Store Purchaser Da OO Le Purchase date AT a ON Model No E J Serial No A SilverStone Technology Co Ltd www silverstonetek com support silverstonetek com Issue date October 2007 NO G11204491
6. own all DC output within 110 to 150 of full load 4 Environment 4 1 Operation Storage Temperature Range Operation 5 C to 50 C nominal input Storage 40 C to 70 C 4 2 Humidity none condensing Operation 20 to 85 RH nominal input Storage 10 to 95 RH 5 Safety 5 1 UL60950 1 5 2 TUV EN 60950 1 5 3 CB 6 EMI REQUIREMENTS 6 1 CE 6 2 BSMI 6 3 FCC part 15 sub part J class B at system load 6 4 CISPR 22 CLASS 7 Dielectric Voltage Withstand HI POT The power supply shall withstand for 3 seconds without breakdown the application of an 1800Vac supply voltage applied between both input line and chassis 15mAAC Cutoff current Isolating transformers shall similarly withstand 4242Vdc applied between both primary and secondary windings for a minimum of one minute 8 PFC Active Power Factor Correction complies with EN 61000 3 2 1995 A1 A2 1998 Class D 9 Electrostatic Discharge ESD Comply with IEC 61000 4 2 a oPi200 A 10 EFT Burst Comply with IEC 61000 4 4 11 Surge Comply with IEC 61000 4 5 12 Burn in Applying 115 Vac 10 or 230 Vac 10 input voltage and maximum load 80 for this product in 45 5 C chamber 13 M T B F The power supply shall have a minimum mean time between failure greater than 100 000 hours at continuous operation of 100 load and an ambient temperature of 25 C 14 Dimension 150 W X86 H X 220 D mm To be valid this sheet must be fil