Home
Lenmar R2G804U - Charger
Contents
1. short circuit or reversed polarity the status LED will flash The damaged cell s should be properly disposed of USB Charge Port operation The USB charge port takes priority over charging AA AAA cells If you have cells installed for charging and a device is plugged into the USB port the charging of the AA AAA cells will be halted until the USB port is no longer being used Once the USB device is fully charged and stops using power or it is unplugged from the USB port the AA AAA cells will resume charging automatically The Green LED indicates when the USB port is in use or availble for use The port has a maximum output of 500mA Do not attempt to overload the USB port or damage to the charger or USB device may result Charge Times Size Type Capacity Charge Time R2G804U Charge Time R2G808U AAA 700 800mAh 2 2 5 hrs 3 5 4 5 hrs AAA 900 1000mAh 3 3 5 hrs 4 5 5 5 hrs AA 1800 2000mAh 3 3 5 hrs 5 6hrs AA 2100 2300mAh 3 5 4hrs 6 7 hrs AA 2500 2800mAh 4 5 5 hrs 7 8 5 hrs Charge time will vary with the capacity condition and amount of charge left in the battery to be charged Specifications Power Supply 100 240V AC 50 60 Hz International Compatible Charge rate AA size 2x 2 8VDC 600mA R2G804 only AAA size 2x 2 8VDC 350mA Charge rate automatically selected Charge rate AA size 2x 2 8VDC 360mA R2G808 only AAA size 2x 2 8VDC 150mA Charge rate automat
2. Caution Do not overcharge the batteries Charger unit is for indoor use only This R2G charger is intended for use with Nickel Metal Hydride batteries only Attempting to charge any other type of battery may cause personal injury and damage to the charger Warranty This R2G charger is warranted to be free of manufacturing defects for two years from the original date of purchase If during the warranty period any part fails to function properly under normal use because of manufacturing defects or workmanship it will be repaired at no charge for parts and labor or at our option the product will be replaced The following is excluded damages from delay or loss of use of equipment or damaged batteries malfunc tions resulting from misuse tampering unauthorized repairs modifications or accident To obtain warranty service package the unit and its accessories carefully using ample padding material to prevent damage in transit and ship it prepaid and insured to LENMAR ENTERPRISES INC USA 4035 VIA PESCADOR CAMARILLO CA 93012 When sending in product for service your package should include evidence of date and place of purchase Enclose 10 00 for shipping and handling for addresses in the U S and 15 00 in Canada For outside the U S and Canada freight will vary depending upon ship to address For further information contact Lenmar Enterprises Inc Phone 800 424 2703 E mail info lenmar com Visit Our Web Site at www lenmar co
3. ically selected USB Output 5VDC 500mA max Safety Features delta V max temp max time overcharge protection bad cell reverse polarity shorted cell detection
4. m 308 084 CK r1 Charging Instructions 1 The battery charger accepts 2 or 4 of either AA or AAA size batteries If you are charging AAA size batteries make sure to use the forward set of negative contacts when inserting the cells When charging 2 cells use either the two locations on the left or right side see diagram 1 Do not mix AA and AAA batteries when charging Diagram 1 Charging 2 cells only 2 Flip out the AC prongs built into the back of the charger and plug into any available 100 240VAC outlet The built in switching power supply will adjust automatically When using overseas a proper plug adapter may be required not supplied When initially plugging the charger into AC power the Green USB status LED will be on Within 10 seconds the Green USB status LED will turn off and the the Red Charge LED s will come on for each location where batteries are installed and charging 3 After charge is complete the red status LED will turn off to indicate that the charge is complete and batteries are ready for use Once the status LED is green the charger switches to trickle mode to keep the batteries at full 4 Once charge is complete remove batteries and unplug charger as soon as it is practical Do not leave batteries in charger for extended periods of time more than 1 2 days or when the charger is not plugged in Unplug the charger when not in use 5 Begin again at Step 1 to charge the next se
5. t of batteries LISINMWYARL RG R EAD Y To Charging System With USB Power Model R2G804U 808U Important Safety Instructions are included Please read the entire manual before use Owner s Manual Thank you for purchasing the R2G Battery and Charger System Please read this manual carefully It contains important operating instructions for your R2G Rechargeable Battery System This R2G charger will quickly and efficiently charge all AA or AAA Nickel Metal Hydride NiMH batteries It also has a convenient USB cherge port for charging your cell phone MP3 player or any other device that accepts power from a USB port The built in high efficiency switching type power supply will adjust automatically to any voltage from 100 240VAC for international use Warning Batteries are partially charged as shipped Must be charged prior to first use for full capacity Charge only NiMH type batteries on this charger Do Not mix AA and AAA or different capacity batteries together when charging Use only R2G NOMEM PRO or other proper NiMH compatible charger to recharge the batteries included Batteries may leak or explode causing personal injury if inserted improperly disposed of in fire mixed with other battery types or short circuited Bad Cell Detection When charge process is started the charger detects the health status of each of the cells in the battery compartment If any battery is unsuitable for charging i e