Home
3com RPS 1000 Redundant Power System
Contents
1. CABLE TYPE DETAILS 0404A08G Cable G RPS power cable 1 meter RPS 500 FEATURES See table page 2 for 3Com switch models supporting an RPS connection 3COM H3C REDUNDANT POWER SYSTEMS The H3C RPS 500 is a low end redundant power system for non PWR H3C and 3Com brand stackable and fixed configuration switches It is a IRU high fixed configuration unit supporting non PWR switches with a single RPS device connection and 50V or 12V DC redundant power Use with gt 3Com Switches 5500G non PWR 4800G non PWR 5500 non PWR gt H3C Switches 5600 non PWR S5500 non PWR S5100 non PWR S3610 non PWR S3600 non PWR SPECIFICATIONS POWER Max output power 12 V output only 125 W 54 V output only 375 W 12 V and 54 V output 125 W for 12 V output 375 W for 54 V output Total lt 500 W Output voltage current Two output connections 53 to 55 Volts 25 Amp Six output connections 53 to 55 Volts 8 Amp ENVIRONMENTAL Output dynamic response PACKAGE CONTENTS 54 VDC 2 Operating temperature 0 to 45 C RPS 500 unit Static regulation 54 VDC 1 32 to 113 F Power cord Input power Operating Humidity Front and rear mounting brackets AC Line Frequency 50 60 Hz 10 to 90 non condensing AC input voltage 110 240 VAC Rubber feet for desktop setup Available Cables for the RPS 500 DIMENSIONS Height 44 mm 1 7 in or 1 RU CABLE TYPE DET
2. allow 4 hours after low temperature storage before operating Humidity operating and storage 5 to 90 non condensing PACKAGE CONTENTS RPS 1000 Unit RPS 1000 unit with one installed power rectifier and one blanking plate one power cord one Cable A with JD5 type connector 0404A053 one Cable B with JD5 type connector 0404A055 front and rear mounting brackets rubber feet for desktop setup six backup fuses 10A 125V grounding cable mini screwdriver for releasing mounting clips user manual Power Rectifier Unit Power rectifier unit label AC Flatpack 1500 M One power cord One Cable A with JD5 type connector 0404A053 Three cables with JD5 A type connector 0404A054 One mini screwdriver for releasing mounting clips NOTE When the RPS 1000 is used with a switch the RPS takes the full power load Therefore the RPS 1000 must have enough power to provision the switch and all Power over Ethernet requirements The RPS 1000 does support giving power to multiple devices provided the connections are present and there is adequate power for the various devices Consider all the power requirements both for the switch or switches themselves together with any PoE connections to ensure that the RPS 1000 has sufficient Watts of output to power the attached switches Available Cables for the RPS 1000 CABLE TYPE DETAILS Cable A JD5 connector For use with PoE PWR units 25A
3. 2 power modules 1200W 110V 1 power module 600W RPS 800 100VAC to 240VAC 1 54V 12A or 54V output only 650W None 12V 17 25A 12V output only 210W 54V and 12V outputs concurrently 650W 1 50V 7 5A or 50V output only 375W None 12V 10 5A 12V output only 125W 54V and 12V outputs concurrently 500W RPS 500 100VAC to 240VAC 3COM SWITCHES WITH RPS SUPPORT RPS 1000 RPS 800 RPS 500 Family SKU Description AMP Rating VDC Cable VDC Cable VDC Cable 5500G 3CR17250 91 Switch 5500G El 24 Port 25AMP 48 to 60 VDC 0404A053 48 to 60 VDC 0404A03U 5500G 3CR17251 91 Switch 5500G EI 48 Port 25AMP 48 to 60 VDC 0404A053 48 to 60 VDC 0404A03U 55006 3CR17252 91 Switch 5500G El PWR 24 Port 25AMP 52 to 55 VDC 0404A053 5500G 3CR17253 91 Switch 5500G El PWR 48 Port 25AMP 52 to 55 VDC 0404A053 5500G 3CR17258 91 Switch 5500G El 24 Port SFP 25AMP 48 to 60 VDC 0404A053 48 to 60 VDC 0404A03U 4800G 3CRS48G 24 91 Switch 4800G 24 Port 10 8 to 13 2 VDC 0404A08G 4800G 3CRS48G 48 91 Switch 4800G 48 Port 10 8 to 13 2 VDC 0404A08G 4800G 3CRS48G 24P 91 Switch 4800G PWR 24 Port 25AMP 52 to 55 VDC 0404A053 4800G 3CRS48G 48P 91 Switch 4800G PWR 48 Port 25AMP 52 to 55 VDC 0404A053 4500G 3CR17771 91 Switch 4500G PWR 24 Port 25AMP 52 to 55 VDC 0404A053 4500G
4. Im length 3Com H3C RPS 500 Cable C Im length 3Com H3C RPS 500 800 Cable G Im length 3Com H3C RPS 500 Cable V Im length ORDERING SKU 0213A01S 0213A01G 0213A02R 0213A01T 0404A053 0404A054 0404A055 0404A03U 0404A03C 0404A08G 0404A03V Visit www 3com com for more information about 3Com secure converged network solutions 3Com Corporation Corporate Headquarters 350 Campus Drive Marlborough MA 01752 3064 3Com is publicly traded on NASDAQ under the symbol COMS Copyright 2008 3Com Corporation All rights reserved 3Com and the 3Com logo are registered trademarks and H3C is a trademark of 3Com Corporation in various countries worldwide All other company and product names may be trademarks of their respective companies While every effort is made to ensure the information given is accurate 3Com does not accept liability for any errors or mistakes which may arise All specifications are subject to change without notice 401108 001 08 08
5. with 54V RPS connections with sufficient power for Power over Ethernet redundancy Use with gt 3Com Switches 5500G 4800G PWR 4500G PWR 4200G PWR 5500 4500 PWR 4200 PWR gt H3C Switches S5600 5500 PWR S5100 EI S3600 EI S PECI FICATI 0 NS DIMENSIONS three cables with JD5 A type One Cable B with JD5 type connector P WER RPS 1000 connector 0404A054 0404A055 Max output power with two power rectifiers 2900 Watt Input power AC line frequency 50 60 Hz AC input voltage 100 120 200 240 VAC Current rating one system 6 8 A Output power with 1 power rectifier Input Voltage 100 VAC to 120 VAC 200 VAC to 240 VAC Output Power 600 Watt 1450 Watt with 2 power rectifiers Input voltage 100 VAC to 120 VAC 200 VAC to 240 VAC Output Power 1200 Watt 2900 Watt Output voltage current Two output connections 53 to 55 Volts 25 Amp Six output connections 53 to 55 Volts 8 Amp Output dynamic response 54 VDC 2 Static regulation 54 VDC 1 RPS 800 FEATURES See table page 2 for 3Com switch models supporting an RPS connection Height 44 5 mm 1 7 in or 1 RU Width 440 0 mm 17 4 in Depth 393 0 mm 15 5 in Weight lt 8kg 17 6 1b Power Rectifier Unit Weight 2 8kg 6 17 1b RELIABILITY Mean Time Between Failure MTBF 420 000 hours 47 9 years ENVIRONMENTAL Operating temperature 5 to 45 C 41 to 113 F Storage temperature 40 to 70 C 104 to 158 F
6. 3CR17772 91 Switch 4500G PWR 48 Port 25AMP 52 to 55 VDC 0404A053 4200G 3CR17671 91 Switch 4200G PWR 24 Port 25AMP 52 to 55 VDC 0404A053 25AMP 48 to 60 VDC 0404A055 5500 3CR17161 91 Switch 5500 El 28 Port 8AMP 48 to 60 VDC 0404A054 48 to 60 VDC 0404A03V 25AMP 48 to 60 VDC 0404A055 5500 3CR17162 91 Switch 5500 El 52 Port 8AMP 48 to 60 VDC 0404A054 48 to 60 VDC 0404A03V 5500 3CR17171 91 Switch 5500 El PWR 28 Port 25AMP 52 to 55 VDC 0404A053 5500 3CR17172 91 Switch 5500 El PWR 52 Port 25AMP 52 to 55 VDC 0404A053 25AMP 48 to 60 VDC 0404A055 5500 3CR17181 91 Switch 5500 El 28 Port FX 8AMP 48 to 60 VDC 0404A054 48 to 60 VDC 0404A03V 4500 3CR17571 91 Switch 4500 PWR 26 Port 25AMP 52 to 55 VDC 0404A053 4500 3CR17572 91 Switch 4500 PWR 50 Port 25AMP 52 to 55 VDC 0404A053 4210 3CR17343 91 Switch 4210 PWR 26 Port 25AMP 52 to 55 VDC 0404A053 3COM H3C REDUNDANT POWER SYSTEMS RPS 1000 The H3C RPS 1000 is an external power supply unit that uses AC inputs and provides eight lines of DC output with a maximum output power of 2900 W Protection is built in against input and output high voltage and FEATURES ne l short circuits Indicator lights show output current status See table page 2 for 3Com switch models supporting an RPS connection This RPS is 1U high two power rectifiers can be installed for 1 1 load sharing and power redundancy It supports switches
7. AILS Width 441 mm 17 4 in 0404A03C Cable C CAB RPS 1m 3026C Depth 165 mm 7 2 in 0404A03U Cable C CAB RPS 1m 3026C Weight lt 3 5kg 7 7 1b 0404A03V Cable V CAB Pwr 1m PS3FP 0404A08G Cable G RPS power cable 1 meter PRODUCT WARRANTY AND OTHER SERVICES ALL MODELS One Year Limited Hardware Warranty return to factory 90 days of telephone technical support ORDERING INFORMATION CaN 3CO PRODUCT DESCRIPTION 3Com H3C RPS 1000 A3 Redundant Power System RPS 1000 Redundant Power System Unit 2 rectifier slots with 1 Power Rectifier Unit and 5 connector cables 1x Cable A with JD5 connector 04044053 3x Cable with JD5 A connector 0404A054 and 1x Cable B with JD5 connector 0404A055 Max output 600W at 110VAC or 1450W at 220VAC 3Com H3C Flatpack1500 M RPS 1000 Power Rectifier Unit and 5 connector cables 1x Cable A with JD5 connector 04044053 3 cables with JD5 A connector 0404A054 and 1x Cable B with JD5 connector 04044055 When installed with a second Power Rectifier Unit together they support a max output of 1200W at 110VAC or 2900W at 220VAC 3Com H3C RPS 800 A Redundant Power System Max output 650W 3Com H3C RPS 500 A3 Redundant Power System Max output 500W Cables 3Com H3C RPS 1000 JD5 Cable A JD5 connector 3Com H3C RPS 1000 JD5A Cable JD5 A connector for non PoE switches 3Com H3C RPS 1000 JD5 Cable B JD5 connector for non PoE switches 3Com H3C RPS 500 Cable U
8. an provide full 15 4 Watts of PoE power MODELS Three models of RPS are offered to support 3Com and H3C fixed configu ration switches Specific RPS units are matched to specific switches based on the switches power specifications RPS 1000 PoE non PoE redundancy with operation at 54V supporting multiple switches This 1U high unit supports up to two power rectifiers and two power inputs for 1 1 power redundancy and multiple power output connec tions to support multiple switch units at the same time It supports switches with 54V redundant power connections with sufficient power for to fully power all PoE ports of a switch with full power redundancy RPS 800 Single switch non PoE redundancy with operation at 12V and 54V A fixed configuration 1U high unit with a single power rectifier and a single power connection Sufficient redundant power for a 48 Port non PoE stackable switch RPS 500 Single switch non PoE redundancy with operation at 12V and 54V A fixed configuration 1U high unit with a single power rectifier and a single power connection 3COM H3C REDUNDANT POWER SYSTEMS RPS SYSTEMS HIGHLIGHTS Input Voltage Range Available Outputs Maximum Power Output RPS Power Redundancy For each power module RPS 1000 100VAC to 240VAC 2 a 54V 25A Maximum power output when all eight outputs are working Optional 1 1 6 A 54V 8A 220V 2 power modules 2900W 220V 1 power module 1450W 110V
9. eZ 300 DATA SHEET Redundant Power Systems for 3Com Enterprise Fixed Configuration Switches 3Com H3C Redundant Power Systems OVERVIEW 3Com H3C Redundant Power Systems are enterprise class power redundancy systems that work with many 3Com fixed configuration switches Redundant power systems RPS are an important element for enterprise networks to provide high network availability RPS power is particularly important for voice ready networks as an element to providing highest phone uptime 3Com Corporation manufactures networking equipment under the H3C brand for sale into many markets These H3C brand RPS units are com patible with many 3Com enterprise fixed configuration switches from the 3Com Switch 5500G Switch 4800G Switch 4500G Switch 4200G Switch 5500 Switch 4500 and Switch 4210 families They are also usable with H3C brand switches Redundant power systems provide two functions for compatible fixed configuration switches Ww An RPS delivers redundant power to switches so there is continued operation should the main switch unit power supply fail Ww An RPS provides more power for IEEE 802 3af Power over Ethernet than what the switches alone can provide For example a 48 port PoE switch might have a PoE power budget of 360 Watts which means that approximately Y the ports can support full IEEE 802 3af PoE power of 15 4 Watts With an RPS providing additional power all 48 switch ports c
10. max output current 0404A053 Cable JD5 A connector For use with non PoE units 8A max output current 0404A054 Cable B JD5 connector For use with non PoE units 8A max output current 0404A055 The H3C RPS 800 is an external DC power supply unit that uses AC input and provides DC output for switch redundant backup power This 1RU RPS provides selective DC outputs Depending on the connected DC output cable s the RPS can provide 12 VDC 54 VDC or 12 VDC and 54 VDC concurrently to the powered device The RPS 800 supports cold backup of power supply which means that the RPS 800 only switches to the DC output state when it detects a power supply failure of the powered device Use with gt 3Com Switch 4800G 48 port gt H3C S5500 52C EI SPECIFICATIONS POWER Max output power 12 V output only 210 W 54 V output only 650 W 12 V and 54 V output 210 W for 12 V output 440 W for 54 V output Total lt 650 W Input power AC Line Frequency 50 60 Hz AC input voltage 110 240 VAC Available outputs 54V 12A 12 V 17 25 A DIMENSIONS Height 44 mm 1 7 in or 1 RU Width 441 mm 17 4 in Depth 182 mm 7 2 in Weight lt 3 8kg 8 4 1b ENVIRONMENTAL Operating temperature 0 to 45 C 32 to 113 F Operating humidity 10 to 90 non condensing PACKAGE CONTENTS RPS 800 unit Power cord Front and rear mounting brackets Available Cables for the RPS 800
Download Pdf Manuals
Related Search
Related Contents
Case Logic LLR-221 HoMedics WFL-SLST Scale User Manual circular saw 2000w ttb287csw - Titan Philips PD7006 Service Manual Memorex mi2290 Portable Speaker User Manual dnx9260bt dnx7260bt dnx5260bt dnx520vbt manuel d`instructions Model PH72 Personal pH/ORP Meter Fresh IC - no running light_Layout 1 Copyright © All rights reserved.