Nortel Redundant Power Supply 15 - 600 Watt No Power cord

image

Contents

1. 5 15 P AC in DC connector EN55022 CISPR 22 Class A EN55024 Interfaces AAOOO5017 E5 Electromagnetic compatibilit CISPR 22 Class A VCCI Class A Japan P d BSMI Class A Taiwan ACA ASIN ae nee eee Class A Australia FCC Part 15 Class A US MTBF gt 2 000 000 hours Noise level lt 60 dBA Shock vibration NEBS GR 63 Std MIL STD 810E METHOD 516 4 procedure IV when packaged for shipping NEBS GR 63 CORE Sect 5 3 1 Category A container NEBS GR 63 CORE Sect 5 1 1 NEBS GR 63 CORE Sect 5 4 3 AA0005719 E5 Physical 14 57 x 5 315 x 3 38 inches 37 0 x 13 5 x 8 58 dimensions cm Weight Chassis 15lbs 6 8kg RPS module 7 5lbs 3 4kg AA0005020 E6 Power e Input requirements Input voltage 90 264VAC e Input frequency range 47 to 440 Hz Nominal 50 60 Hz e Inrush current maximum 40A e Leakage current 0 5 mA to 3 0 mA maximum for any input voltage e Output requirements Output voltage and current 600W power supply module e DC output 47 5V output 600W Minimum Load OA Full Load 12 5A e Operating temperature O to 45 C e Storage temperature 25 C to 70 C e Operating relative humidity 5 to 85 relative humidity non condensing e Storage temperature humidity 95 maximum relative humidity non condensing e Operating altitude Up to 10 000 feet above sea level e Storage altitude Up to 30 000 feet above sea level e Cooling forced air 2X30 CFM 80 mm fans TUV GS mark cTUVus mark
2. IEC950 EN60950 EN50091 1 CB certificate and report with all national deviations AS NZS 3260 NOM 019 SCFI IRAM requirements AA0005021 E6 Environmental xX gt Finland France Standards and certifications Nortel is a recognized leader in delivering communications capabilities that enhance the human experience ignite and power global commerce and secure and protect the world s most critical information Our next generation technologies for both service providers and enterprises span access and core networks support multimedia and business critical applications and help eliminate today s barriers to efficiency speed and performance by simplifying networks and connecting people with infor mation Nortel does business in more than 150 countries For more information visit Nortel on the Web at www nortel com For more information contact your Nortel representative or call 1 800 4 NORTEL or 1 800 466 7835 from anywhere in North America Nortel the Nortel logo Nortel Business Made Simple and the Globemark are trade marks of Nortel Networks All other trademarks are the property of their owners Copyright 2007 Nortel Networks All rights reserved Information in this document is subject to change without notice Nortel assumes no responsibility for any errors that may appear in this document CUTTY ARE ATT CT A A NN119860 062207 BUSINESS MADE SIMPLE
3. 1 PWR 5520 48T or 470 48 1 PWR 600W RPS Module AA0005719 DC to DC converter DC cable for PoE switches Typical applications PoE devices Connect up to 3 x 5520 24T 5520 48T 4550 1 PWR 4548GT PWR 470 241 PWR or 470 48 T PWR to provide each switch with 740W in power sharing mode Order DC cable AA0005018 E6 to connect 5520 PWR 4500 PWR or 470 P WR switches Ethernet Switch 470 PWR can provide 370W to connected devices To provide redundancy to an Ethernet Routing Switch 5530 24TFD use one Redundant Power Supply Module per switch DC cable 25ft 7 6m DC cable 10ft 3m 1 per 4 AL1904007 E6 AA0005021 E6 switches Ethernet Routing Switch 5520 1 1 f inch Aa0o0050i8 E6 Ethernet Routing Switch 5530 1 1 inch AA0005018 E6 gt Ethernet Switch 470 1per 4 AL1904005 E5 AA0005021 E6 switches Ethernet Routing Switch 1per 4 AL1904007 E6 AA0005021 E6 4526FX 4550T 4548GT switches Ethernet Routing Switch incl AA0005018 E6 4550T PWR 4548GT PWR 3 Must be replaced with country code A through F for local power cord options Use one cable to connect up to 4 switches Non PoE devices Connect up to 12 Ethernet Switch 470 or Ethernet Routing Switch 4526FX 4550T 4548GT and 5510 to provide power protection to these switches A single 600W Redundant Power Supply Module can protect up to four switches from power disruption Use DC cable AA0005021 EG to connect four s
4. 470 470 PWR and Ethernet Routing Switches 4526FX 45507 4548GT 5510 5520 and 5530 In case of a power outage the Redundant Power Supply 15 will immediately take over providing power to the switch Ethernet Routing Switch 4550T PWR 4548GT PWR 5520 24T PWR 5520 48T PWR and Ethernet Switch 470 PWR can be configured to share the internal and external power source to provide power to the switch itself and connected PoE devices Chassis AA0005017 Switch type Ethernet Routing Switch 5510 When a third party UPS is added it ensures continuity of AC power even during AC mains failure power sag surges or blackouts For example a customer can provide redundant power protection to a stack of Nortel ERS4500 switches by delivering a second power source to the switches in the stack using the RPS15 The Redundant Power Supply 15 can protect up to four non PoE switches per 6000W Redundant Power Supply Module Up to three modules fit in a Redundant Power Supply 15 chassis Power Sharing Mode When the Redundant Power Supply 15 is used together with Ethernet Routing Switch 4550T PWR 4548GT PWR 5520 48 T PWR or Ethernet Switch 470 48 T PWR PoE power per port can be increased to full 15 4W on all 48 ports In power sharing mode both the internal AC power supply and the RPS15 power supply provide power to the switch and PoE ports This enables the switch to deliver up to 740W or 15 4W per port on a 4550T PWR 4548G
5. NORTEL Ordering information Redundant Power Supply 15 Chassis Supports three power supplies EUED RoHS 5 6 compliant Redundant Power Supply 15 Connecting Cable 1 8m 6ft for a Single Ethernet Routing Switch 4550T PWR 4548GT PWR 5520 24T PWR 5520 48T PWR 5530 or Ethernet Switch 470 24T PWR 470 48T PWR does not require DC DC converter RoHS 6 6 Redundant Power Supply 15 600 Watt Power Supply Module Up to three can be installed in RPSU15 chassis AAOQOO5017 E5 Requires separate RPSU connection cable between PSU and switch No power cord Redundant Power Supply 15 Long Connecting Cable 7 6m 25ft for up to 4 x Ethernet Routing Switch 4526FX 4550T 4548GT 5510 24T 5510 48T Ethernet Switch 470 24T 470 48T Requires separate DC DC converter for connection to switch RoHS 6 6 Redundant Power Supply 15 Short Connecting Cable 3m 10ft for up to 4 x Ethernet Routing Switch 4526FX 4550T 4548GT 5510 24T 5510 48T Ethernet Switch 470 24T 470 48T Requires separate DC DC converter for connection to switch RoHS 6 6 The seventh character of the switch order number must be replaced with the proper code to indicate desired product nationalization No power cord included Includes European Schuko power cord common in Austria Belgium Germany The Netherlands Norway and Sweden Includes power cord commonly used in the United Kingdom and Ireland Includes power cord commonly used in Jap
6. Using the Nortel Redundant Power Supply 15 Provides power redundancy to Ethernet Routing Switches 4500 series and 5500 series Ethernet Switch 470 and 470 PWR Compact packaging Single chassis 2U high for standard 19 rack provides scalable Redundant Power Supply for multiple devices Highly efficient Redundant Power Supply modules available in 600 watt rating provide redundant power to up to 12 devices per chassis Flexible deployment Redundant Power modules may be purchased separately and installed into the chassis as needed while unit remains fully operational Protects mission critical enterprise applications from interruption due to problems with either the power source or power units within network devices Ensures business continuity When a third party UPS is added it ensures continuity of AC power to switches and other network devices even during AC mains failure power sag surges or blackouts The Nortel Redundant Power Supply 15 improves network availability by providing redundant power options to improve the network uptime The Redundant Power Supply 15 maintains network operation in case of device power failure Power is provided to switches simultaneously without requiring a device reboot The modular chassis allows you to acquire additional modules as your network grows The Redundant Power Supply Modules are hot swappable so additional protection can be added within no
7. an Includes North American power cord Includes Australian power cord also commonly used in New Zealand and the People s Republic of China In the United States Nortel 35 Davis Drive Research Triangle Park NC 27709 USA In Canada Nortel 195 The West Mall Toronto Ontario M9C 5K1 Canada In Caribbean and Latin America Nortel 1500 Concorde Terrace Sunrise FL 33323 USA In Europe Nortel Maidenhead Office Park Westacott Way Maidenhead Berkshire SL6 3QH UK In Asia Nortel United Square 101 Thomson Road Singapore 307591 Phone 65 6287 2877
8. assis AAOO005017 E5 Requires separate RPSU connection cable between PSU and switch No power cord AAO0005021 E6 Redundant Power Supply 15 Short Connecting Cable 3m 10ft for up to 4 x ERS 4526FX 4550T 4548GT 5510 24T 5510 48T Ethernet Switch 470 24T 470 48T Requires separate DC DC converter for connection to switch AA0005018 E6 Redundant Power Supply 15 Connecting Cable 1 8m 6ft for a single ERS 4550T PWR 4548GT PWR 5520 24T PWR 5520 48T PWR 5530 or Ethernet Switch 470 24T PWR 470 48T PWR does not require DC DC converter AL1904007 E6 48 V DC to DC converter for installation in the Ethernet Routing Switch 5510 48T and 5510 24T 4526FX 4550T 4548GT AL1904005 E5 48 V DC to DC converter for installation in the Ethernet Switch 470 24T and 470 48T A Redundant Power Supply Unit 15 chassis to house the 600W Redundant Power Supply Modules is required B In total three 600W modules are needed All PoE switches need a separate 600W module In this example we need two for PoE switches one for the Ethernet Routing Switch 5520 and one for the Ethernet Switch 470 48T PWR Three non PoE switches like the Ethernet Switch 470 the Ethernet Routing Switch 5510 4550T or 4548GT require a third 600W module Now all three slots of the chassis are filled with 600W Redundant Power Supply Modules You can choose various power cord options this example is without a power cord C When connecting non PoE switches lik
9. e Ethernet Switch 470 Ethernet Routing Switch 5510 4550T or 4548GT you can use the 1 4 cable that allows you to connect up to four switches to one 600W module In this example the customer could add another non PoE switch in the future D When connecting a PoE switch like the Ethernet Routing Switch 4550T PWR 4548GT PWR 5520 48T PWR 5520 24T PWR or Ethernet Switch 470 48T PWR to the Redundant Power Supply unit 15 a 1 1 connecting cable is required to connect each PoE switch to one separate 600W module In this example we have two of these switches so we need two connecting cables E Some switch models require a separate DC to DC converter to enable the DC power slot at the back of the switch and connect a DC cable This DC to DC converter is typical for the Ethernet Routing Switch 5510 or Ethernet Routing Switch 4526FX 4550T and 4548GT F To connect an Ethernet Switch 470 to the Redundant Power Supply 15 this DC to DC converter that is specific to the Ethernet Switch 470 is required Please note that this DC converter is different than used in ERS 5500 or ERS 4500 series products Please note that although Ethernet Routing Switch 5530 24TFD is not a PoE switch it has a 1 1 requirement for a 600W Redundant Power Supply module Also the DC to DC converter is already inbuilt So from an RPS 15 engineering perspective you should treat it as if it is a 5520 or 470 PWR switch Technical specifications Standard AC wall plug NEMA
10. rmal office hours and without downtime of the network The Redundant Power Supply 15 can be used to provide power sharing or protection for Nortel Ethernet Routing Switch 4550T PWR 4548GT PWR 5520 24T PWR 5520 481T PWR and Ethernet Switch 470 PWR as well as power protection for non PoE switches Up to 12 switches can be power protected with one Redundant Power Supply 15 providing maximum efficiency For additional resiliency the Redundant Power Supply 15 provides customers with the freedom to choose their corpo rate standard Uninterruptible Power Supply vendor The Redundant Power Supply 15 is 2RU high and can accommodate up to three Redundant Power Supply Modules These Redundant Power Supply Modules provide up to 600W of power each The Redundant Power Supply Modules feature two front facing LED indicators HERTEL eS TERR to display both status of AC and DC power A basic Redundant Power Supply 15 configuration consists of a chassis that is shipped with two blank panels preinstalled The Redundant Power Supply 15 requires at least one hot swappable Redundant Power Supply Module which must be ordered as a separate item Additionally a DC power cable needs to be ordered to connect to the DC power socket of the switch Depending on the switch type a separate DC to DC converter is required Power Protection Mode The Redundant Power Supply 15 provides power protection for Ethernet Switch
11. witches to a single Redundant Power Supply Module For maximum deployment flexibility a long DC cable of 25 ft 7 6 m is available AA0005020 E6 How to choose Various flexible deployment options are available for the Redundant Power Supply 15 It can be used in conjunction with many Nortel Ethernet Routing Switches and Ethernet Switches The previous table outlines valid combinations Qualification questions e Is network uptime and uninter rupted activity critical to your business e Do you have multiple wiring closet switches e Is space limited in your wiring closets e Do you have multiple high demanding PoE devices connecting into you wiring closet Example configuration This hypothetical example shows the various items required for a customer quotation of a Redundant Power Supply Unit 15 A customer wants to provide power redundancy with the Redundant Power Supply 15 to the following Nortel switching products e 1 x Ethernet Routing Switch 5510 24T e 1 x Ethernet Routing Switch 5520 48T PWR e 1 x Ethernet Switch 470 48T e 1 x Ethernet Switch 470 481T PWR e 1 x Ethernet Routing Switch 4550T Your Redundant Power Supply 15 quote should include the following components Order number Product description AAOO05017 E5 Redundant Power Supply 15 Chassis Supports three power supplies AAOOOS5A19 E5 Redundant Power Supply 15 600 Watt Power Supply Module Up to three can be installed in RPSU15 ch