Home
Eaton 2 COM ports communication card
Contents
1. shielded male DB9 cable connector female DB9 connector DB9 RJ45 cable wiring diagram male RJ45 connector male DB9 connector MGE UPS SYSTEMS 5102933200 AA Appendices Glossary COM RS232 communication port with HID protocol HID Human Interface Device MultiSlot extension module for communication cards Solution Pac UPS power management software suite from MGE UPS SYSTEMS UPS Uninterruptible Power Supply D MGE urs SYSTEMS 5102933200 AA Index Communication cable dudas p 12 13 Communicalion card dotes tue eo de ade o obo Ever een AN EE oo ed p 9 10 11 12 MultiSlot module eem ar nnne nnne p 10 11 13 Solution Pac software sss Ier p 10 12 13 TROUDIESNOOUING mee p 13 UPScontrol remote control panel p 10 12 13 MGE UPS SYSTEMS Nothing will stop you now 140 avenue Jean Kuntzmann ZIRST Montbonnot St Martin 38334 St Ismier Cedex FRANCE www mgeups com 5102933200 AA MGE UPS SYSTEMS SS Publication MGE UPS SYSTEMS 01 2000
2. THE MERLIN GERIN KNOW HOW Carte de communication 2 ports COM Manuel d installation et d utilisation 2 COM ports communication card Installation and user manual MGE UP Ss Sie Ms Pe Nothing will stop you now Sommaire Pr sentation R ception du mat riel 2 OIOOKdOUQ tte 2 Recyclage de l emballage 2 FONCION usc huele ere 3 Vue d ensemble 3 InstallaHOn 4 UHISAHOP ee 5 D pannage Anomalies de fonctionnement 6 Remplacement du c ble 6 Annexes do abet b Re te 7 LOK ER 7 Tous les produits de la gamme MGE UPS SYSTEMS sont prot g s par des brevets ils mettent en ceuvre une technologie originale qui ne pourra tre utilis e par aucun concurrent de MGE UPS SYSTEMS En raison de l volution des normes et du mat riel les caract ristiques indiqu es dans ce document ne nous engagent qu apr s confirmation par nos services Reproduction de ce document autoris e apr s accord de MGE UPS SYSTEMS et avec la mention obligatoire Manuel d installation et d utilisation de la carte de communication 2 ports COM n 5102933200 MGE UPS SYSTEMS 5102933200 AA Presentation Reception du materiel L option que vous venez d acheter se compose des l ments suivants voir figure 1 une carte
3. Elle peut tre ins r e soit dans une ASI Fig 3 soit dans un module MultiSlot Fig 4 II n est pas n cessaire de mettre hors tension l appareil avant d ins rer la carte Cas d une ASI Galaxy PW changer la face avant de la carte avec celle sp cifique aux ASI Galaxy PW ASI 7 WY Fig 4 MGE UPS SYSTEMS 5102933200 AA Utilisation Pour administrer l installation a l aide d un logiciel Solution Pac il faut relier l un des ports COM de la carte au syst me de surveillance Fig 5 Le c ble de communication est fourni avec l ASI Pour utiliser le terminal de contr le distance UPScontrol Fig 6 la connexion s effectue l aide du c ble fourni avec celui ci voir son manuel utilisateur Le voyant vert de la carte de communication se comporte de la mani re suivante il clignote r guli rement toutes les secondes pendant la phase de d marrage il clignote plus rapidement pendant l initialisation du dialogue sur le bus UPS BUS il reste allum pendant la phase de construction de la base de donn es et ensuite clignote au rythme des changes de donn es sur le bus UPS BUS Les 2 ports COM sont alors op rationnels et peuvent tre utilis s simultan ment Les m me types de connexion sont r a
4. Module Malti SIOU ee p 3 4 6 PrODIGMCS ees eer non p 6 Terminal UPS COMOL x3 o obo uk e d i ads orl ede p 3 5 6 MGE UPS SYSTEMS 5102933200 AA Q MGE UPS SYSTEMS 5102933200 AA Presentation Installation Operation Troubleshooting Appendices Contents Contents of package 9 metr 9 Recycling of packing 9 FUNCION mec E 10 Overall view asyay ay 10 Or APPETERE 11 pu MA Eri E iu et eich M M MEME 12 Operating anomalies 13 Cable replacement 13 COS Say ace dd diede 14 Life ER 14 All MGE UPS SYSTEMS products are protected by patents They implement original technology which is not available to other competitors of MGE UPS SYSTEMS To take evolving standards and technology into account the technical characteristics contained in this document are not binding unless confirmed by MGE UPS SYSTEMS This document may be reproduced only with the consent of MGE UPS SYSTEMS Authorised copies must be marked MGE UPS SYSTEMS 2 COM ports communication card installation and user manual n 510293200 AA Presentation Contents of package This optional equipment is made up of the following components see figure 1 one communication card a card cover
5. de communication une face avant sp cifique aux ASI Galaxy PW un manuel d installation et d utilisation le pr sent document Stockage En cas de stockage avant sa mise en service laisser votre carte de communication dans son emballage d origine et l abri de l humidit temp rature de stockage 40 C 70 Fig 1 Recyclage de l emballage Concernant le rebut de l emballage veuillez vous conformer aux dispositions l gales en vigueur MGE UPS SYSTEMS 5102933200 AA Fonction La carte de communication 2 ports COM appartient a la famille des cartes de communication transverses A ce titre elle peut tre utilis e dans toutes les ASI quip es d un bus UPS BUS ainsi que dans un module MultiSlot Elle est quip e de deux ports de communication RS232 ind pendants sur lesquels peuvent se connecter un logiciel d administration de la famille Solution Pac un terminal de contr le distance UPScontrol Elle impl mente le protocole HID Vue d ensemble Fig 2 pr sentation de la carte de communication L gende 1 port de communication COM 2 voyant vert de visualisation du fonctionnement de la carte 3 port de communication COM 4 connecteur de liaison au bus UPS BUS MGE UPS SYSTEMS 5102933200 AA Installation La carte de communication 2 ports COM est pr te a l emploi Elle ne n cessite aucun parametrage
6. simultaneously Same kind of connections are to be done in case of using a MultiSlot module D MGE UPS SYSTEMS 5102933200 AA Troubleshooting Operating anomalies If the green light on the communication card remains off check that the card is correctly inserted in the slot and that its cover is well screwed on check the power supply of the UPS or MultiSlot remove and re seat the card If the green light on the communication card remains on more than 3 minutes check that the card is correctly inserted in the slot and that its cover is well screwed on remove and re seat the card If a communication fault is detected by Solution Pac software or by UPScontrol check that the communication cable is correctly connected on both sides remove and re seat the card If the problem continues contact our after sales support department Cable replacement If the communication cable is lost or damaged a cable wired as indicated in Fig 7 for the connection to a UPS or in Fig 8 for the connection to UPScontrol may be used DB9 DB9cable male DB9 female DB9 connector connector Fig 7 DB9 RJ45 cable male DB9 male RJ45 connector connector Fig 8 DB9 DB9 cable wiring diagram
7. specific for Galaxy PW UPSs one installation and user manual this document Storage If the card is stored prior to installation it should remain in the original packing in a dry place The storage temperature range is 40 C to 70 C Recycling of packing Packing materials must be disposed of in compliance with applicable laws and regulations Fig 1 DEN x COM COM A fe os je MGE UPS SYSTEMS 5102933200 AA Function Overall view The 2 COM ports communication card is part of transverse communication cards This card may then be used in any UPSs equipped with UPS BUS as well as in the MultiSlot module This card has two independent RS232 communication ports on which can be connected one monitoring software included in Solution Pac one remote control panel UPScontrol The HID protocol is used Fig 2 presentation of the communication card Key 1 COM communication port 2 green light indicating the operation of the communication card 3 COM communication port 4 connector to the UPS BUS MGE UPS SYSTEMS 5102933200 AA Installation The 2 COM ports communication card is ready to use No settings are needed It can be inserted either in a UPS s slot Fig 3 or in the MultiSlot module Fig 4 You do not need to power down the device before inserting the card Case of Galaxy PW UPSs remove the moun
8. ion est signal depuis le logiciel Solution Pac ou le terminal UPScontrol v rifier que le c ble de communication est correctement fix ses deux extr mit s enlever la carte puis l ins rer de nouveau Si le probl me persiste contacter notre service apres vente MGE urs SYSTEMS 5102933200 AA Remplacement du cable En cas de perte ou de d t rioration du c ble de communication il est possible d utiliser un c ble r pondant aux caract ristiques d taill es en Fig 7 pour une connexion une ASI ou en Fig 8 pour une connexion un UPScontrol cable DB9 DB9 connecteur DB9 femelle connecteur DB9 m le Fig 7 cable DB9 RJ45 connecteur connecteur DB9 male RJ45 male Fig 8 schema de cablage du cable DB9 DB9 cable connecteur blinde DB9 m le connecteur DB9 femelle sch ma de c blage du c ble DB9 RJ45 connecteur RJ45 m le connecteur DB9 m le Annexes Glossaire ASI Alimentation Sans Interruptions COM port de communication RS232 avec protocole HID HID Human Interface Device MultiSlot module d extension pour carte de communication Solution Pac ensemble de logiciels d administration des ASI MGE UPS SYSTEMS Index C ble de communication 5 6 Carte de COMMUNICATION e vei e abe eed p 2 3 4 5 Logiciels Solution Pao x uuu u u uyu Re Medecine t eis p 3 5 6
9. liser lorsque la carte est utillis e avec un module MultiSlot ASI Fig 5 ASI UPScontrol MGE 510297000 NT 01 Made in France MGE UPS SYSTEMS 5102933200 AA o Depannage Anomalies de fonctionnement Si le voyant vert de la carte de communication reste teint en permanence verifier que la carte est correctement ins r e dans son emplacement et que sa face avant est bien viss e verifier que le systeme ASI ou MultiSlot est sous tension enlever la carte puis l ins rer de nouveau Si le voyant vert de la carte de communication reste allum en permanence pendant plus de 3 minutes v rifier que la carte est correctement ins r e dans son emplacement et que sa face avant est bien viss enlever la carte puis l ins rer de nouveau Si un d faut de communicat
10. ted card cover and use the Galaxy PW UPSs specific one ASI WY MGE UPS SYSTEMS 5102933200 AA Fig 4 Operation To monitor the installation with Solution Pac software you have to connect one COM port of the card to the monitoring system Fig 5 The communication cable is supplied with the UPS To use UPScontrol Fig 6 the connection must be carried out with the communication cable supplied with UPScontrol see its User Manual ASI The green light on the communication card operates as follows flashes once every second during the start up phase flashes more rapidly during initialization of Fig 5 the dialogue on the UPS BUS stays lighting during database processing and then flashes at a rate corresponding ASI UPScontrol to the flow of data on the UPS BUS Then the 2 COM ports are available and can be used