Home
APC Rack PDU, Basic, 1U, 16A, 208&230V
Contents
1. APC PDU AP9553 AP9558 Installation Manual Contents Before You Begin Safety and grounding information 5 Installation Mounting options 6 Attach the mounting brackets 6 Attach the unit to the enclosure 7 Operation irritar Front view 8 Rear view 9 Power Cords 10 Warranty and Service Limited warranty 11 Warranty limitations 11 Obtaining service 11 Life Support Policy General policy 13 Examples of life support devices 13 Specifications Lisa Product specifications AP9553 14 Product specifications AP9558 15 APC PDU Installation Manual Before You Begin Safety and grounding information A Electrical Hazard Please read the following information before installing or operating your APC Power Distribution Unit PDU APC PDU AP9553 and AP9558 Installation Manual This PDU is intended for indoor use only Do not install this PDU where excessive moisture or heat is present Never install any wiring equipment or PDUs during a lightning storm Plug this PDU into a three wire grounded power outlet only The power outlet must be connected to appropriate branch circuit mains protection fuse or circuit breaker Connection to any other type of power outlet may result in a shock hazard Use only the supplied brackets for mounting Do not use extension cords or adapters with this PDU Do not work alone under ha
2. PC product is available at no charge in any ofthe following ways e Visit the APC Web site to find answers to frequently asked questions FAQs to access documents in the APC Knowledge Base and to submit customer support requests Www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information Wwww apc com support Global support with FAQs knowledge base and e support e Contact an APC Customer Support center by telephone or e mail Regional centers APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702020 Ireland Japan 03 5434 2021 Guidance 3 Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright O 2002 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo and NetShelter are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 6049B 03 2002
3. f its products in the following situations e In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness e In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term ife support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with this modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care APC PDU AP9553 and AP9558 Insta
4. ity of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction To obtain support for problems with your PDU 1 Note the serial number and date of purchase 2 Contact Customer Support at a phone number on the back cover of this document A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover APC PDU AP9553 and AP9558 Installation Manual 11 Warranty and Service damage sustained in transit Enclose a letter w th your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment 1f applicable 5 Mark the RMA number clearly on the outside of the shipping carton 6 Ship by insured prepaid carrier to the address provided by the Customer Support technician 12 APC PDU AP9553 and AP9558 Installation Manual Life Support Policy General policy Examples of life support devices American Power Conversion APC does not recommend the use of any o
5. llation Manual 13 Specifications Product specifications Input voltage range 100 250 V 120V 16A UL 120V 12A cUL Maximum current draw 240V 16A VDE 208V 12 8A UL 208V 8A cUL Physical 4 00 x 1 75 x 17 0 in 10 16 x 4 45 x 43 18 cm Net weight 3 0 lb 1 36 kg Shipping weight 5 4 lb 2 45 kg Environmental Elevation above MSL Operating 0 to 10 000 ft 0 to 3000 m Storage 0 to 50 000 ft 0 to 15 000 m Size Temperature e Operating 32 to 113 F 0 to 45 C e Storage 13 to 149 F 225 to 65 C Relative Humidity e Operating 0 to 95 non condensing Storage 0 to 95 non condensing Approvals Standards UL cUL VDE 14 APC PDU AP9553 and AP9558 Installation Manual Specifications Product AP9558 Input voltage range 100 250 V 120V 16A UL 120V 12A CUL 208V 12 8A UL 208V 8A CUL 4 00 x 1 75 x 17 0 in 10 16 x 4 45 x 43 18 cm Environmental Elevation above MSL e Operating 0 to 10 000 ft 0 to 3000 m Storage 0 to 50 000 ft 0 to 15 000 m Maximum current draw Temperature e Operating 32 to 113 F 0 to 45 C Storage 13 to 149 F 225 to 65 C Relative Humidity Operating 0 to 95 non condensing e Storage 0 to 95 non condensing Approvals Standards UL cUL APC PDU AP9553 and AP9558 Installation Manual 15 www apc com APC Worldwide Customer Support Customer support for this or any other A
6. nput power cord AP9871 The cord ends are IEC 320 C19 and NEMA L6 20 e 12 additional power cords AP9870 that you can use to connect the output receptacles to the load equipment The cord ends are IEC 320 C13 and IEC 320 C14 DL To purchase other cords see Input Power Cords for Rack Mount PDUs 990 1112 shipped with your PDU 10 APC PDU AP9553 and AP9558 Installation Manual Warranty and Service Limited warranty Warranty limitations Obtaining service APC warrants the PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty 1s limited to repairing or replacing at 1ts own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Except as provided herein APC makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibil
7. tched hole on each vertical rail 2 Al gn the mounting holes of the brackets with the installed caged nuts Insert the screws and tighten APC PDU AP9553 and AP9558 Installation Manual 7 Operation Front view Review the following figures and related descriptions to familiarize yourself with the components and the operation of your PDU O Circuit The circuit breaker 1s tripped when Breaker the button 1s extended When it 1s tripped the PDU is overloaded and at least one piece of equipment needs to be unplugged The circuit breaker is rated to trip at the same overload as most home and office utility service branch protectors 20 8 APC PDU AP9553 and AP9558 Installation Manual Rear view Operation Outlets Plug pull out guard o Power cord guard Power inlet O Ground stud Twelve IEC C13 outlets 10A at 240V 15A at 120V Guard used to prevent cords from being accidentally disconnected from the outlets Four are provided Guard used to prevent power cord from being accidentally disconnected from the inlet IEC C20 inlet 16A at 240 V 20A at 120V 6 32 ground stud that can be used to ground the unit to the enclosure APC PDU AP9553 and AP9558 Installation Manual 9 Operation Power Cords The AP9553 model includes a detachable 8 ft input power cord The cord ends are IEC 320 C20 and IEC 320 C19 The AP9558 model includes the following cords e A detachable 12 ft i
8. zardous conditions Check that the power cord plug and socket are in good condition To reduce the risk of electric shock when grounding cannot be verified disconnect the PDU from the power outlet before installing or connecting equipment Reconnect to the power outlet only after making all connections Equipment must have a protective earth connector which carries the leakage current from the load devices computer equipment Do not exceed a total leakage current of 3 5 mA Installation Mounting This PDU was designed to be mounted in a variety of options orientations within an enclosure The mounting brackets included are equipped with multiple hole patterns for horizontal or vertical installation Study the figures on this page and the next for mounting options Attach the 1 Choose a mounting option 1 to 4 and orient the brackets mounting appropriately brackets 2 Attach the brackets to the unit using four flat head Phillips screws provided for each bracket 6 APC PDU AP9553 and AP9558 Installation Manual Installation Attach the unit l Choose a location for the unit and install four caged nuts to the enclosure provided with your enclosure in your chosen location Al gn the caged nuts with the brackets you attached to the unit If you are attaching your PDU to a NetShelter enclosure s vertical mounting rail install the caged nuts immediately above and below a Note no
Download Pdf Manuals
Related Search
Related Contents
Harbor Freight Tools 110 lb. Pressurized Abrasive Blaster Product manual White Rodgers 1F80-24 Thermostat User Manual User Manual - lvi cameras CERCAMETALLI MANUALE UTENTE MANUAL DE OPERAÇÃO Kenmore Elite 32 cu.ft. Super Capacity French Door Bottom-Freezer Refrigerator ENERGY STAR Energy Guide Whirlpool W10200946A User's Manual 取扱説明書 全自動電気洗濯機 品番 ASW-70A Philips HMP3000 Copyright © All rights reserved.