Home

SECO-LARM SA-025Q

image

Contents

1. Momentary trigger no delay 1K ohm resistor included Note regarding DIP switch 1 Sometimes DIP switch 1 will function as an instant delay control but when it is ON its actual function depends on how DIP switch 3 is set DIP 1 setting Function OFF 1 sec momentary relay output ON DIP 3 ON Relay output latches on ON DIP 3 OFF Relay output equals 1 sec b Action If the TRG terminal is connected to momentarily the relay output immediately activates for about one second To reset the SA 025Q the TRG must be disconnected from for at least two seconds The timer has no effect c Triggering by powering unit up If DIP switch 5 is set to ON the output works the same but instead of triggering via the TRG terminal the SA 025Q is triggered by being powered up 4 Latched Output delayed Fig 5 a DIP switch settings 1 ON 2 ON 3 ON 4 Timer setting ON or OFF 5 OFF 6 OFF
2. 1 The SA 025Q Programmable Timer Module is suitable for a wide range of timed security and access control operations such as door unlock timing siren or bell timer VCR timer and so on Auto sensing of input voltage and DIP switches for programming make installation easy Features Specifications Timer can be set from 1 second to 60 minutes Can be triggered via a N O positive trigger input signal or a N C negative trigger device or by powering up the unit Relay can be programmed to activate at the start or at the end of the timing cycle Relay can also be set to activate for one second at the end of the timing cycle Relay can be programmed to pulse flash or be steady on Built in reset function to manually reset timing cycle Form C relay contacts rated 8A 120VAC 24VDC LED indicates relay is energized 12VDC 24VDC operation auto sensing Current draw Less than 1mA standby or 50mA relay energized Board measures 2 7 8 x 2 1 2 73 x 63 mm Functions programmed via DIP switches no jumpers to cut Fig 1 DIP switch settings Switch 1 2 3 4 5 6 Off Fixed 1 sec Relay output time Relay energizes at start of timing cycle REPEAT timing cycle Time in MINUTES Timing controlled by TRG input Counter begin at START of TRG On Variable Relay output time Relay energizes at end of timing cycle SINGLE timing cycle
3. Timing in SECONDS Timing controlled by Power Up Counter begin at END of TRG ENFORCER Installation Manual SA 025Q Programmable Timer Module Wiring TRG N O Positive trigger input signal or N C Negative trigger input signal 1K ohm resistor required included Ground input 12VDC to 24VDC input NO Relay output normally open COM Relay output common NC Relay output normally closed DIP Switch Settings Programming The SA 025Q is programmed via a series of six DIP switches which can be turned on or off See fig 1 b Action If the TRG terminal is connected to for the time set by the timer the relay activates and remains activated To reset the latched relay connect the TRG terminal momentarily to again c Triggering by powering unit up If DIP switch 5 is set to ON the delay period set by the timer starts when the SA 025Q is powered up At the end of the delay period the relay latches on and remains on until the SA 025Q is disconnected from power 5 Pulsing or Flashing Output instant or delay Fig 6 a DIP switch settings 1 Relay output mode see below 2 Instant delay start see below 3 OFF 4 Timer setting ON or OFF 5 OFF 6 OFF b Action If the TRG terminal is connected to momentarily the SA 025Q waits for the time set by the timer and then starts pulsing flashing T
4. MISA 025Q_074 MIA025 P65 FEB2003 Order Part 760 100 3 074 PITSW1 2 Setting the Timer The relay output time can be programmed for either 1 to 60 seconds or 1 to 60 minutes using the round black thumbwheel 1 Determine and set DIP switch 4 according to whether the timing should be measured in seconds or minutes see DIP Switch Settings above 2 Turn the thumbwheel on the SA 025Q clockwise to increase time and counter clockwise to decrease time 3 Test the time and make adjustments as needed NOTE You should carefully test the time period once it is set Sample Installations for Common Timer Applications NOTE The following only represents a few of the many possible ways to use this Timer Module For your specific application it may be necessary to experiment with the DIP switch settings 1 Momentary trigger no delay for timed annunciator or supervisory circuit Fig 2 a DIP switch settings 1 ON 2 OFF 3 ON 4 Timer setting ON or OFF b Action If the TRG terminal is connected to momentarily the relay output immediately turns on The output stays on for the time set by the timer after which it turns off regardless of whether the trigger is connected or disconnected NOTE If the momentary trigger time is less than the time set by the timer the relay output is triggered only once If the trigger time is longer than the timer time the relay will be activated a second ti
5. Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2007 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM SECO LARM SECO LARM SECO LARM SECO LARM SECO LARM U S A Inc U S A Inc U S A Inc U S A Inc U S A Inc 16842 Millikan Avenue Irvine CA 92606 Tel 800 662 0800 949 261 2999 Fax 949 261 7326 Website www seco larm com E mail sales seco larm com file D DTP
6. he pulse flash output lasts until the TRG terminal is disconnected from c Triggering by powering unit up If DIP switch 5 is set to ON the output works the same but instead of triggering via the TRG terminal the SA 025Q is triggered by being powering up d Instant delay start If DIP switch 2 is set to ON the SA 025Q waits for the time set by the timer after triggered or powered up and then starts pulsing flashing If DIP switch 2 is set to OFF the SA 025Q starts pulsing flashing as soon as it is triggered or powered up e Relay output time If DIP switch 1 is set to ON the relay on and off time depends on how the timer is set If DIP switch 1 is set to OFF the relay on time is fixed at about 1 second and the relay off time depends on how the timer is set 6 Optional Negative Trigger or Closed Circuit Trigger Fig 7 If a closed circuit negative trigger is required it is necessary to install a 1K 1 000 ohm resistor as shown included Note Products with model number that ends with Q or have a green Q sticker represents RoHS compliant products WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This
7. me when the trigger is removed c N O vs N C output For a timed door annunciator connect a buzzer or chime to the N O and COM outputs For a closed loop supervisory circuit connect a dialer or transmitter to the N C and COM outputs 2 Momentary trigger no delay for swinger eliminator Fig 3 a DIP switch settings 1 ON 2 OFF 3 ON 4 Timer setting ON or OFF b Action If the TRG terminal is connected to momentarily the relay output immediately turns on and stays on for as long as the TRG terminal is connected to Once the TRG connection is broken the relay output remain activated for as long as the time period set by the timer and then turns off c Triggering by powering unit up If DIP switch 5 is set to ON the output works the same but instead of triggering via the TRG terminal the SA 025Q is triggered by powering it up Once powered up the relay remains activated for the time set by the timer or until power is removed whichever comes first 3 One time 1 sec momentary trigger no delay Fig 4 a DIP switch settings 5 OFF 6 OFF 5 OFF 6 ON 1 OFF 2 OFF 3 ON 4 Timer setting ON or OFF 5 OFF 6 ON 3 Fig 2 Momentary trigger no delay Fig 7 Optional negative or closed circuit trigger Fig 6 Pulse flash o p instant delay Fig 5 Latched output delayed Fig 4 1 time mom trigger no delay Fig 3