1. Stabilimento di produzione retim Tesisi abail Lii Subsidiary Empresa filial OMRON HEALTHCARE UK LTD Succursale Dochteronderneming Opal Drive Fox Milne Milton Keynes MK15 0DG U K Niederlassung Consociata Yan Kurulus OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH As jl CAS yl Gottlieb Daimler Strasse 10 68165 Mannheim GERMANY www omron healthcare de OMRON SANT FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Uniquement pour le march francais OMRON Service Apr s Vente N Vert 0 800 91 43 14 consommateurs omron sante fr www omron healthcare fr Made in Vietnam Fabricado en Vietnam Fabriqu en Vietnam Geproduceerd in Vietnam Hergestellt in Vietnam Bo Prodotto in Vietnam Vietnam da retilmistir eli ui gha
2. Nederlands Automatic Blood Pressure Monitor Model M6 Comfort peer Instruction Manual inal All for Healthcare IM HEM 7321 E 01 08 2013 2298869 1A 0 a N ol 0 38 88 8 7 135 oa Li 1 69 a b LE d LS li am LZ z 8 2 Check following components V rifier les composants suivants Controleer de volgende onderdelen Pr fen Sie folgende Teile des Lieferumfangs Controllare i componenti indicati di seguito A a daki bile enleri kontrol edin iCompruebe los siguientes componentes cu gsal ca Thank you for purchasing the OMRON M6 Comfort Automatic Blood Pressure Monitor The OMRON M6 Comfort is a compact fully automatic blood pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly For comfortable controlled inflation without the need of pressure pre setting or re inflation the device uses its advanced IntelliSense technology Intended Use This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population who can understand this instruction manual with the arm circumference range printed on the arm cuff Th
3. The accuracy of this device has been carefully tested and is designed for a long service life It is generally recommended to have the device inspected every 2 years to ensure correct functioning and accuracy Please consult your OMRON retail outlet or distributor 5 Maintenance and Storage 5 2 Storage Keep the device in its storage case when not in use 1 Unplug the air plug from the air jack 2 Gently fold the air tube into the arm cuff Note Do not bend or crease the air tube excessively 3 Place the monitor and the arm cuff in the storage case Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours Locations exposed to vibrations shocks or where it will be at an angle 23 5 Maintenance and Storage 5 3 Optional Medical Accessories within the scope of EC Medical Device Directive 93 42 EEC Arm cuff AC adapter Arm circumference 22 42 cm Intelli Cuff L 9911730 8 Adapter S 9515336 9 Adapter UK 9983666 5 Model HEM FL31 24 5 Maintenance and Storage Using the Optional AC Adapter 1 Insert the AC adapter plug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical outlet first and then remove the A
4. safely A When handling the power cord take care not to do the following Do not damage Do not break it Do not tamper with it Do not forcibly bend or pull Do not twist Do not bundle during use Do not pinch Do not place under heavy objects A Wipe the dust off from the power plug A Unplug monitor when not in use A Disconnect the power plug before cleaning A Use only the original AC adapter designed for this device Use of unsupported adapters may damage and or may be hazardous to the device Important Safety Information Battery Usage A Do not insert the batteries with their polarities incorrectly aligned A Use only 4 AA alkaline or manganese batteries with this device Do not use other types of batteries Do not use new and used batteries together A Remove the batteries if the device will not be used for three months or more General Precautions EJ Do not forcibly crease the arm cuff or the air tube excessively Do not press the air tube while taking a measurement To unplug the air plug pull on the air plug at the connection with the monitor not the tube itself Do not drop the monitor or subject device to strong shocks or vibrations Do not inflate the arm cuff when it is not wrapped around your arm Do not use the device outside the specified environment It may cause an inaccurate reading Read and follow the Important information regarding Electro Magnetic Compatibility EMC i
5. 3 The arm cuff was inflated above 299 mmHg when inflating the arm cuff manually Do not inflate the arm cuff above 299 mmHg Refer to section 3 3 Movement during measurement Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 Clothing is interfering with the arm cuff Remove any clothing interfering with the arm cuff Refer to section 3 1 Device error Contact your OMRON retail outlet or distributor 4 Error Messages and Troubleshooting 4 2 Troubleshooting Problem The measurement result is extremely high or low Arm cuff is applied too loosely Solution Apply the arm cuff tighter Refer to section 3 1 Movement or talking during measurement Remain still and do not talk during measurement Refer to section 3 3 Clothing is interfering with the arm cuff Remove any clothing interfering with the arm cuff Refer to section 3 1 Arm cuff pressure does not rise The air connector is not securely connected into the air jack Make sure that the air tube is connected securely Refer to section 3 1 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to section 5 3 Arm cuff deflates too soon The arm cuff is loose Apply the arm cuff correctly so that itis firmly wrapped around the arm Refer to section 3 1 Cannot measure or the results are too low or
6. Indicates a potentially hazardous situation which if not avoided could result in death or serious injury General Usage Consult your physician before using the device in pregnancy including pre eclampsia or if diagnosed with arrhythmia or arteriosclerosis Do not use the device on the injured arm or the arm under medical treatment not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion EJ Consult your physician before using the device on the arm with an arterio venous A V shunt Do not use the device with other medical electrical ME equipment simultaneously Do not use the device in the area the HF surgical equipment MRI or CT scanner exists or in the oxygen rich environment A The air tube or the AC adapter cable may cause accidental strangulation in infants Contained small parts that may cause a choking hazard if swallowed by infants AC Adapter optional Usage Do not use the AC adapter if the device or the power cord is damaged Turn off the power and unplug the power cord immediately Plug the AC adapter into the appropriate voltage outlet Do not use in a multi outlet plug Never plug in or unplug the power cord from the electric outlet with wet hands A Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property General Usag
7. for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 2007 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the device and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it a re
8. 42 cm Nylon polyester polyvinyl chloride Monitor arm cuff instruction manual storage case battery set blood pressure pass 6 Specifications Notes These specifications are subject to change without notice In the clinical validation study the 5th phase was used on 85 subjects for determination of diastolic blood pressure This device has not been validated for use on pregnant patients 60197 This device fulfils the provisions of EC directive 93 42 Medical Device Directive This device is designed according to the European Standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems This OMRON device is produced under the strict quality system of OMRON HEALTHCARE Co Ltd Japan The core component for OMRON devices which is the Pressure Sensor is produced in Japan 27 28 6 Specifications Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements
9. C adapter plug from the monitor 25 26 6 Specifications Product description Model Display Measurement method Measurement range Accuracy Inflation Deflation Memory Rating Power source Battery life Applied part Protection against electric shock Operating temperature humidity Storage temperature humidity air pressure IP classification Weight Outer dimensions Cuff circumference Cuff Tube material Package contents Automatic Blood Pressure Monitor OMRON M6 Comfort HEM 7321 E LCD digital display Oscillometric method Pressure 0 to 299 mmHg Pulse 40 to 180 beats min Pressure 53 mmHg Pulse 5 of display reading Fuzzy logic controlled by electric pump Automatic pressure release valve 100 measurements with date and time for each user 1 and 2 DC6V 4W 4 AA batteries 1 5V or optional AC adapter Adapter S 9515336 9 INPUT AC100 240V 50 60Hz 0 12A Adapter UK 9983666 5 INPUT AC100 240V 50 60Hz 15VA Approximately 1000 measurements using new alkaline batteries Type BF Internally powered ME equipment When using only the batteries n Class II ME equipment Optional AC adapter 10 C to 40 30 to 85 RH 20 C to 60 C 10 to 95 RH 700 1060hPa IP 20 Monitor Approximately 380g without batteries Arm cuff Approximately 163g Monitor Approximately 124 w mm 90 h mm 161 1 mm Arm cuff Approximately 145 mm x 532 mm air tube 750 mm 22 to
10. Device To View the Average Value 1 Select your USER ID 1 or 2 2 Press and hold the amp button for more than 3 seconds D Eg 4 I 3c Notes If the previous measurement was taken without setting the date and time the average value is not calculated f there are no measurement values stored in the memory the screen to the az right is displayed 14 3 Using the Device To View the Weekly Average Value The monitor calculates and displays weekly averages for the measurements taken in the morning and evening within 8 weeks for each user Note The week begins Sunday at 2 00 1 Select your USER ID 1 or 2 2 Press the button ar The morning average for THIS WEEK appears on the display D Note The morning hypertension symbol appears if the morning weekly average is BB above 135 85 mmHg Press the xXX 2 button again and the evening average for THIS WEEK appears on the display Press the or gt button to display the previous weeks This week Last week 2 weeks ago Continue to 7 weeks ago Morning average Gy average lt gt average press Morning average p 22 This week Last week 2 weeks ago 7 weeks ago Evening average Evening average Evening average Evening average 3 Using the Device Note If there are no measurement values stored in the memory the screen to
11. asurement values Blood pressure NANNININ An irregular heartbeat rhythm is defined as a rhythm that is 2596 less or 2596 Irregular Heartbeat EJ more than the average rhythm detected while the monitor is measuring the Short Long systolic and diastolic blood pressure Pulse If the irregular heartbeat symbol amp displays with your measurement Blood pressure NIIS fNUN results we recommend you consult your physician Follow the directions of your physician Movement Error Symbol f The movement error symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Take another measurement remain still during measurement Average Value Symbol The average value symbol is displayed when you press and hold the memory button for more than 3 seconds The most recent average value appears on the display screen Cuff Wrap Guide Lamp Q If the cuff was wrapped too loosely it may cause unreliable results If the wrapping of cuff is too loose the cuff wrap guide Lamp 3 lights in orange Otherwise 68 lights in green This is the function which is used as an aid in determining if the cuff is wrapped snugly enough 1 Know Your Device Blood Pressure Colour Indicator If your systolic or diastolic pressure is above the standard range 135 mmHg for the Systolic blood pressure and or 85 mmHg for the diastolic blood pressure the blood pressure colour indicator will light i
12. e Always consult your physician Self diagnosis of measurement results and self treatment are dangerous A People with severe blood flow problems or blood disorders should consult a physician before using the device as the arm cuff inflation can cause bruising 2 Important Safety Information there are any abnormalities during the measurement remove the arm cuff A Do not use this device on infants or persons who cannot express their intentions A Do not inflate the arm cuff more than necessary A Do not use the device for any purpose other than measuring blood pressure A Use only the approved arm cuff for this device Use of other arm cuffs may result in incorrect measurement results A Do not use a mobile phone or other devices that emit electromagnetic fields near the device This may result in incorrect operation of the device A Do not disassemble the monitor or arm cuff A Do not use in a location with moisture or a location where water may splash on the device This may damage the device A Do not use the device in a moving vehicle car airplane A Do not take measurements more than necessary It may cause bruising due to blood flow interference A Consult your physician before using the device if you had a mastectomy AC Adapter optional Usage A Fully insert the power plug into the outlet A When disconnecting the power plug from the outlet do not pull the power cord Be sure to pull from the power plug
13. e Date Time display will disappear 2 Release the START STOP button when the Date Time display turns off The arm cuff will start to inflate automatically A Always consult your physician Self diagnosis of measurement results and self treatment are dangerous 12 3 Using the Device 3 4 Using the Memory Function The monitor automatically stores the results up to 100 sets for each user 1 and 2 It can also calculate an average value based on the last 3 measurement values taken within 10 minutes Notes f there are only 2 measurement values in the memory for that period the average will be based on these EN 2 values If there is 1 measurement value in the memory for that period this is displayed as the average If the memory is full the monitor will delete the oldest value When viewing the measurement value taken without setting the date and time is displayed instead of the date and time To View the Measurement Values Stored in Memory 1 Select your USER ID 1 or 2 2 Press the amp button The Memory number appears for a second before the pulse rate is displayed The newest set is numbered 1 Note The cuff wrap guide result appears on the display with the measurement values The cuff wrap guide lamp will not light 3 Press the 4 or button to view the values stored in the memory 4 To the older values gt To the more recent values 13 3 Using the
14. e and Time Set the monitor to the correct date and time before taking a measurement for the first time 1 Press the Date Time setting button The year flashes on the Date Time display 2 Push or button to change the year Push 9 button to confirm the year and then the month flashes Repeat the same steps to change the month day hour and minutes Year Vt 201314 tho 1 lt gt Confirm Forward Back Month Y vt D5 Change Day Confirm gt Change Confirm Hour Y nein Cr gt Change Confirm Minute Y Penn Au TE Confirm 3 Press the START STOP button to turn the monitor off Notes f the batteries have been replaced the date and time setting will need to be reset f the date and time are not set appears during or after measurement Using the Device rr Open both the front and rear covers to read the following The letter identifiers on the cover pages correspond to those in the body of this page 3 1 Applying the Arm Cuff Remove tight fitting clothing or tight rolled up sleeve from your left upper arm Do not place the arm cuff over thick clothes EJ 1 Insert amp the air plug into the air jack securely 2 Apply the arm cuff to your left upper ar
15. e device detects the appearance of irregular heartbeats during measurement and gives a warning signal with measurement result Important Safety Information 1 1 Know Your Device 4 2 Preparation esee 7 2 1 Battery 7 2 2 Setting the Date and Time 8 3 Using the 9 3 1 Applying the Arm Cuff 9 3 2 How to Sit Correctly 10 3 3 Taking a Measurement 11 3 4 Using the Memory Function 13 Error Messages and Troubleshooting 18 4 1 Error Messages 18 4 2 Troubleshooting 20 Maintenance and Storage 22 5 1 Maintenance 22 5 2 etr rdg a dE 23 5 3 Optional Medical Accessories 24 Specifications 26 Warranty eese 29 Some Useful Information about Blood 55 m 30 Please read this instruction manual thoroughly before using the device BA Please keep for future reference For specific information about your own blood pressure CONSULT YOUR PHYSICIAN Important Safety Information Warning
16. easurement values in the memory for 2 people using USER ID 1 and USER ID 2 1 Select your USER ID 1 2 1 2 a 4 0 08 2 Press the START STOP button The arm cuff starts to inflate automatically WSTART WINFLATE WDEFLATE WCOMPLETE wu your systolic pressure is DT B 181 more than 210 mmHg Se H After the arm cuff starts to inflate press and 1 sin nn hold the START STOP button until the Le 12 monitor inflates 30 to 40 mmHg higher than your expected systolic pressure dim mim mmi Notes The monitor will not inflate above 299 mmHg Do not apply more pressure than necessary 11 3 Using the Device 3 Remove the arm cuff 4 Press the START STOP button to turn the monitor off The monitor automatically stores the measurement result in its memory It will automatically turn off after 2 minutes Note Wait 2 3 minutes before taking another measurement Waiting between measurements allows the arteries to return to the condition prior to taking a measurement Using the Guest Mode The monitor stores measurement values for 2 users in the memory The guest mode can be used to take a single measurement for another user No measurement values are stored in the memory when the guest mode is selected 1 Press and hold the START STOP button for more than 3 seconds E The USER ID symbol and th
17. ete the values stored in the memory All values for the user you select will be deleted 17 4 Error Messages and Troubleshooting 4 1 Error Messages Display Solution Remove the arm cuff Wait 2 3 minutes and then take another measurement Repeat the steps in section 3 3 If this error continues to appear contact your physician Irregular heartbeats are detected Movement during measurement read and repeat the steps in section Apply the arm cuff tighter Refer to section 3 1 Arm cuff is applied too loosely You should replace the batteries with new The batteries are low ones ahead of time Refer to section 2 1 You should replace the batteries with new The batteries are exhausted ones at once Refer to section 2 1 18 4 Error Messages and Troubleshooting Display Air plug is disconnected Solution Insert the air plug securely Refer to section 3 1 Arm cuff is applied too loosely Apply the arm cuff tighter Refer to section 3 1 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to section 5 3 Movement during measurement and the arm cuff has not been inflated sufficiently Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 If E2 appears repeatedly inflate the arm cuff manually until it is 30 to 40 mmHg above your previous measurement result Refer to section 3
18. ient s blood pressure What is Arrhythmia Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio electrical system that drives the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse Why is it a Good Thing to measure Blood Pressure at Home Many factors such as physical activity 200 Upper curve systolic blood pressure anxiety or the time of day can influence uid ac M your blood pressure A single 150 H measurement may not be sufficient for an accurate diagnosis Thus it is best to try 100 PE ui and measure your blood pressure at the same time each day to get an accurate 50r indication of any changes in blood 5 12 n 18 24 pressure Blood pressure is typically low in the morning and increases from afternoon to evening It is lower in the summer and higher in the winter mmHg Example fluctuation within a day male 35 years old Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto ud 617 0002 JAPAN EU representative OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS www omron healthcare com Production facility Planta de producci n OMRON HEALTHCARE MANUFACTURING VIETNAM CO LTD Site de production Productiefaciliteit Binh Duong Province VIETNAM Produktionsst tte
19. m The bottom edge of the arm cuff should be a 1 to 2 cm above the elbow O Air tube is on the inside of your arm and aligned with your middle finger 3 Secure closed with the fabric fastener Notes When you take a measurement on the right arm the air tube will be at the side of your elbow Be careful not to rest your arm on the air tube 5 The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different OMRON recommends to always use the same arm for measurement If the values between both arms differ substantially please check with your physician which arm to use for your measurement 3 Using the Device 3 2 How to Sit Correctly To take a measurement you need to be relaxed and comfortably seated under comfortable room temperature Avoid bathing drinking alcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your feet flat on the floor Sit upright with your back straight c Sit with your back and arm being supported The arm cuff should be placed on your arm at the same level as your heart d 10 3 Using the Device 3 3 Taking a Measurement Notes To cancel a measurement press the START STOP button to release the air in the arm cuff Remain still while taking a measurement The monitor is designed to take measurements and store the m
20. n orange when the measurement result is displayed If they are within the standard range the blood pressure colour indicator will light in green The JNC7 Guideline recommends the following guideline General Guidelines for Blood Pressure Prehypertension at Office Hypertension at Home Systolic Blood Pressure 120 139 mmHg 135 mmHg Diastolic Blood Pressure 80 89 mmHg 85 mmHg These are from statistical values for blood pressure JNC7 The Seventh Report 2003 Dec of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure 2 Preparation 2 1 Battery Installation 1 Remove the battery cover 2 Insert 4 AA batteries as indicated in the battery compartment 3 Replace the battery cover Notes When the low battery symbol 171 appears on the display turn the monitor off then replace all batteries at the same time Long life alkaline batteries are recommended The measurement values continue to be stored in memory even after the batteries are replaced The supplied batteries may have a shorter life A Disposal of used batteries should be carried out in accordance with the national local regulations for the disposal of batteries 2 Preparation the rear cover page to read the following The letter identifiers on the rear cover page correspond to those in the body of this page 2 2 Setting the Dat
21. n the 6 Specifications Read and follow the Correct Disposal of This Product in 6 Specifications when disposing of the device and any used accessories or optional parts 1 Know Your Device the rear cover page to read the following The alphabet in the rear cover page correspond to those in the body page Monitor Display Cuff wrap guide lamp OMemory button D Weekly average button START STOP button Up Down buttons USER ID selection switch Date Time setting button DBlood pressure colour indicator QAir jack Battery compartment DAC adapter jack for optional AC adapter Arm cuff Arm cuff Arm circumference 22 42cm MAir plug Air tube Display P Memory symbol USER ID symbol Average value symbol Systolic blood pressure Diastolic blood pressure D Heartbeat symbol Flashes during measurement WV Date Time display W Morning average symbol amp Evening average symbol Morning hypertension symbol Movement error symbol Irregular heartbeat symbol 68 pressure level indicator 0 Cuff wrap guide Low battery symbol Deflation symbol Pulse display Memory number 1 Know Your Device Display Symbols Irregular Heartbeat Symbol 8 Normal Heartbeat When the monitor detects an irregular rhythm two or more times during the Pulse A measurement the irregular heartbeat symbol amp will appear on the display with the me
22. of a claim those will be charged for f Damages of any kind including personal caused accidentally or from misuse 9 Calibration service is not included within the guarantee h Optional parts have a one 1 year warranty from date of purchase Optional parts include but are not limited to the following items Cuff and Cuff Tube AC Adapter Should guarantee service be required please apply to the dealer whom the product was purchased from or an authorised OMRON distributor For the address refer to the product packaging literature or to your specialised retailer If you have difficulties in finding OMRON customer services contact us for information www omron healthcare com Repair or replacement under the guarantee does not give rise to any extension or renewal of the guarantee period The guarantee will be granted only if the complete product is returned together with the original invoice cash ticket issued to the consumer by the retailer 29 30 8 Some Useful Information about Blood Pressure What is Blood Pressure Blood pressure is a measure of the force of blood flowing against the walls of the arteries Arterial blood pressure is constantly changing during the course of the heart s cycle The highest pressure in the cycle is called the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressures the Systolic and Diastolic are necessary to enable a physician to evaluate the status of a pat
23. sponsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal Thank you for buying an OMRON product This product is constructed of high quality materials and great care has been taken in its manufacturing It is designed to give you every satisfaction provided that it is properly operated and maintained as described in the instruction manual This product is guaranteed by OMRON for a period of 3 years after the date of purchase The proper construction workmanship and materials of this product is guaranteed by OMRON During this period of guarantee OMRON will without charge for labour or parts repair or replace the defect product or any defective parts The guarantee does not cover any of the following EJ a Transport costs and risks of transport b Costs for repairs and or defects resulting from repairs done by unauthorised persons c Periodic check ups and maintenance d Failure or wear of optional parts or other attachments other than the main device itself unless explicitly guaranteed above e Costs arising due to non acceptance
24. the right is displayed Morning Weekly Average m Measurements of the morning This is the average for the Sunday Monday Tuesday Wednesday Thursday Friday Saturday measurements taken during the morning 22 irst measurement Measurement 4 00 11 59 between Sunday and the morning Up to 3 measurements Saturday An average for each day is emm H calculated for up to three measurements ene taken within 10 minutes of the first 5 measurement of the morning 11 59 Evening Weekly Average 9 Measurements of the evening This is the average for the Sunday Monday Tuesday Wednesday Thursday Friday Saturday measurements taken during the evening bs 19 00 1 59 between Sunday and 1 e Saturday An average for each day is calculated for up to three measurements taken within 10 minutes of the last T 1 Within 10 minutes measurement of the evening Up to 3 measurements Last measurement M the evening Evening Blood Pressure 1 6 1 59 3 Using the Device To Delete All the Values Stored in Memory The values stored in the memory are deleted by USER ID 1 Select your USER ID 1 or 2 2 Press the Memory button while the memory symbol E EJ appears While holding the button down press the START STOP button for more than 3 seconds Note You cannot partially del
25. too high The arm cuff has not been inflated sufficiently Inflate the arm cuff so that it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3 4 Error Messages and Troubleshooting Problem Nothing happens when you press the buttons The batteries are empty Solution Replace the batteries with new ones Refer to section 2 1 The batteries have been inserted incorrectly Insert the batteries with the correct polarity Refer to section 2 1 Other problems Press the START STOP button and repeat measurement Replace the batteries with new ones If the problem continues contact your OMRON retail outlet or distributor 21 22 5 Maintenance and Storage Maintenance To protect your device from damage please observe the following Store the device and the components in a clean safe location Do not use any abrasive or volatile cleaners Do not wash the device and any components or immerse them in water Do not use petrol thinners or similar solvents to clean the device iD 45 Use a soft and dry cloth or a soft and moistened cloth and neutral soap to clean on the monitor and the arm cuff Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the device or components Consult your OMRON retail outlet or distributor Calibration and Service