Home
SECO-LARM E-942FC-1K3SQ
Contents
1. Magnetic Gate Lock Bracket Installation Manual a ly al TROUBLESHOOTING Gate does not lock No power e Check to make sure the wires are secure e Check that the power supply is connected and operating e Make sure the unit is wired correctly Gate locks but can be Poor contact between Make sure the electromagnet and easily forced open electromagnet and armature plate are properly aligned e Make sure the contact surfaces of the electromagnet and armature plate are clean and free from rust Incorrect voltage setting e Check the power leads with a meter and make sure the correct voltage is present Delay in gate releasing A secondary diode was The electromagnet is fitted with a metal installed across the oxide varistor to prevent interference so electromagnet do not install a secondary diode armature plate REGULAR MAINTENANCE Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non abrasive non corrosive cleaner Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust Check that the armature plate is securely attached to the bracket yet can pivot slightly around the armature screw Check that the electromagnet is securely attached to the bracket UL CERTIFICATION Electromagnetic lock only Model E 942FC 1300 E 942FC 600 conforms to UL 10B Fire Tests of Door Assemblies and UL 10C Positive Pressure Fire Tests of Door Ass
2. al ee es C Mount the armature 1 Once the electromagnet is mounted determine the armature bracket location and tack weld into place Tack weld only 2 Dismount the armature plate from the bracket Warning Failure to remove the armature plate from the bracket will damage the armature and rubber washer Weld the armature bracket with 3 or 4 beads about 1 apart Make sure not to weld near the set screw hole See mounting diagram for No Weld areas 3 Remount the armature a Put one rubber washer between two steel washers and place them over the armature screw between the armature and the bracket This will allow the armature to pivot slightly around the armature screw in order to compensate for gate misalignment b Make sure the guide pins are inserted into guide holes to prevent the armature from spinning c Do not overly tighten the armature against the bracket The armature must be able to pivot around the armature SCrew D Run the wires The goal is to keep as little of the wires exposed as possible 1 Run the wires into an out of sight location as close as possible to the electromagnet 2 Use standard armored cable to prevent the wires from being cut between the electromagnet and the out of sight location E Connect the wires Note Unit is prewired for 12V operation See Wiring Diagram below for more information 1 For 12V operation Connect the red and white wires to 12VDC and the black and green wire
3. cally Four knockouts on the junction box Adapter and mounting hardware included Voltage 12VDC or 24VDC Prewired for 12VDC operation Current draw 500mA 12VDC 250mA 24VDC MOUNTING THE ELECTROMAGNETIC LOCK A Determine type of gate 1 Single swing gate Gate swings on one end and comes to rest on a fixed gate post when closed In this case a typical installation has the electromagnet fixed to the gate post and the armature connected to the free end of the gate 2 Double swing gate Two gates swing in the same direction when activated The electromagnet is fixed to the free end of one gate and the armature is fixed to the free end of the other 3 Sliding gate The gate slides instead of swings away from a fixed gate post A typical installation has the electromagnet fixed to the gate post and armature connected to the free end of the gate B Mount the electromagnet In most cases the position of the electromagnet will determine the location of the armature plate Make sure there is space to run the cable 1 Tack weld bracket into place Tack weld only 2 Dismount the electromagnetic lock from the bracket Warning Failure to remove electromagnetic lock will result in severe damage to lock Weld 3 or 4 beads about 1 apart Make sure not to weld the junction box See diagram for No Weld areas 3 Remount the electromagnetic lock Page 1 Magnetic Gate Lock Bracket Installation Manu
4. emblies for swinging door assemblies It is also classified in accordance with the Uniform Building Code standard 7 2 LIFETIME LIMITED WARRANTY tris seco Larm product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM Under no circumstances will SECO LARM be responsible for any costs or charges for removal installation or reinstallation This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to repair or replacement only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else This lifetime limited warranty is for products sold and installed in the United States and Canada For all other countries the warranty is 1 one year NOTICE The information and specifications printed in this manual are curre
5. nction box screws Maglock Bracket will be bolted to 4 x Mounting screws EVA M5521 3 gate fence and not welded Cut 4 x Anti tamper caps length of bolt as necessary x R 2 x Guide pins FS ed 1 x Security screw i i Be Black ln 1 x Allen wrench for junction box 1 x AC pigtail connector a 1 x EVA M5521 3 DC pigtail connector Oo 2 x Wire connectors 1 x Power Supply Power Supply Input 100 240 VAC 50 60Hz Output 12VDC 1 0A lt power supply Page 3
6. nt at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2011 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM FILE DT DTP MiE 942FC xxxSb pmd SECO LARM U S A Inc ORDER PART 764 024 _077 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com on Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com Page 4 SECO LARM U S A Inc Installation Manual E 942FC 1K35Q0 E 942FC 600S0H Electromagnetic Lock with Weldable Brackets for Gates E 942FC 1K3SQ Shown For most types of outdoor sliding and swinging electric gates Includes a magnetic lock with brackets for armature and magnet AIN Brackets can be welded or bolted directly to gate RWHS Holding force E 942FC 1K3SQ 1 300 pounds 591kg WY E 942FC 600SQ 600 pounds 272kg Brackets are zinc plated for corrosion resistance U C cL us LISTED Magnetic lock only Brackets have black finish to match most gates Water and vandal resistant attractive stainless steel finish Maintenance free factory sealed design Fail safe operation unlocks door if power is removed Mounted verti
7. s to ground 2 For 24V operation Connect the red wire to 24VDC the green wire to ground and then tie the white and black wires together and insulate IMPORTANT Damage caused by improper connection will void warranty F Test the unit G Insert the tamper caps into the mounting screw access holes of the electromagnet This should be the last step as once the tamper caps are in place they are difficult to remove Wiring Diagram Control device such as push button switch keypad card reader etc 12VDC Prewired 12VDC Black Green GND Note AC pigtail connector is included with the E 942FC 1K3SQ E 942FC 600SQ for those applications where needed Page 2 SECO LARM U S A Inc Magnetic Gate Lock Bracket Installation Manual Mounting Diagram Maglock Bracket Electromagnet Anti Tamper Armature Plate Mounting Armature Caps x 2 Bolts Bracket optional A Mounting Screws x 2 Rubber Washer Armature Mounting Bolts optional Large Steel Washers EE A Mounting Bolts Mounting Screws x 2 Anti Tamper Guide optional Security No Caps x 2 Pin Screw Weld Junction Box Area Screws x 4 Junction Box List of Parts Optional Parts 1 x Maglock bracket l 1 x Armature bracket N a A 3 8 Flat Socket Cap Mounting 1 x Armature screw N E 2 x Large steel washers Note Use in those applications 1 x Rubber washer where Armature Bracket and 4 x Ju
Download Pdf Manuals
Related Search
Related Contents
Friedrich PDXRC User's Manual 2. Installation Instructions - Windows (Download) 安川インバータ J1000 小形シンプル 取扱説明書 取扱説明書 [PDF形式] Targus 15.4" Trademark Toploading 300 Edition Notebook Case Nilfisk-ALTO 1000S User's Manual Rotel RA-820BX2 User's Manual MANUAL DE INSTRUCCIONES Vol 2. Art 3 - Instituto de Geofísica y Astronomía Le terme et ses réseaux. Un outil pour l - CEUR Copyright © All rights reserved.