Home

Accu-Tech 61110-RE6 wire connector

image

Contents

1. Verde 5 3 White Green White Orange 4 2 Orange Vert 5 3 Blanco Verde Blanco Naranja 6 6 Green Orange 5 3 Blanc Vert Blanc Orange 6 6 Verde Naranja 7 7 White Brown White Brown 6 6 Vert Orange 7 7 Blanco Marr n Blanco Marr n 8 8 Brown Brown 7 7 Blanc Brun Blanc Brun 8 8 Marr n Marr n i i i i idi ii AVISO En ciertos cables los conductores para las clavijas n meros MOTE BA e A we m K O REMARQUE dans certains c bles les fils des broches 2 4 6 et 8 ont 2 4 6 y8 pueden poseer rayas blancas Este es el for the same pin numbers une rayure blanche mais leur couleur de fond est la equivalente de cables de un color para los mismos n meros m me que celle des fils unis de clavijas IMPORTANT INSTRUCTIONS DIRECTIVES IMPORTANTES INSTRUCCIONES IMPORTANTES 1 Read and understand all instructions Follow all warnings 4 Lire les pr sentes directives et s assurer de bien les 1 Lea y comprenda perfectamente todas las instrucciones and instructions marked on the product E observer tous les avertissements et Siga todas las instrucciones y advertencias marcadas 2 Do not use this product near water e g near a tub wash directives apparaissant sur le dispositif sobre el producto basin kitchen sink or laundry tub in a wet basement or 2 Ne pas installer ce dispositif proximit d une source 2 No utilice estos productos cerca del agua por ejemplo near a swimming pool d eau comme une baignoire un bac laver une cuve cerca de ba era
2. establecidos por TIA 568 B 2 Estos conectores ofrecen flexibilidad con sus etiquetas universales de color codificadas para ambas normas T568A y T568B INSTALACI N 1 Retire aproximadamente 7 6cm del aislamiento del cable Si su cable posee un separador interno de alambre tambi n ret relo 2 Seleccione su configuraci n de cableado T568A o T568B y observe los c digos de color en la etiqueta localizada sobre el lado del conector La etiqueta tambi n incluye los n meros de las clavijas 3 Deje no mas de 3 2 mm de cable pelado en el lado del conector luego dirija los cables para su conexi n utilizando el c digo de color de la Tabla 1 AVISO Si el cable llega desde la parte superior aseg rese que posee suficiente exceso de cable en el par trenzado y no coloque el aislamiento en el rea de conexi n 4 Utilice sus dedos para apoyar delicadamente los cables sobre las ranuras IDC Coloque una herramienta de impacto calibrada para impacto leve LOW en la posici n perpendicular al conector Mantenga el trenzado del cable a no mas de 12 7mm del contacto IDC Instale y corte el cable Conecte un par a la vez luego de apoyarlo sobre la ranura IDC para evitar aplastar las cables internos con la herramienta de impacto Apoye el cable de manera que el aislamiento toque la parte posterior del conector como se muestra Ilustraci nes 1 y 2 5 Coloque la tapa de protecci n del conector sobre los cables para asegurar su conex
3. gamme GigaMax offrent un rendement de cat gorie 5e ou plus TIA 568 B 2 les dispositifs eXtreme se plient minimalement aux exigences de cat gorie 6 TIA 568 B 2 1 Dot s d tiquettes de terminaison universelles ils offrent en outre une grande souplesse en s adaptant aux modes de c blage T568A et T568B INSTALLATION 1 Retirer environ 7 6 cm de la gaine et le cas ch ant de l me fil s parateur rigide au centre de certains c bles 2 Examiner le chromocodage sur l tiquette du connecteur et choisir celui qui correspond au mode de c blage utilis T568A ou T568B Cette tiquette indique galement les num ros de broche 3 Laisser un espace de 3 2 mm au plus entre la gaine du c ble et la paroi du connecteur puis acheminer les fils en vue de leur terminaison conform ment au chromocodage du tableau 1 REMARQUE quand on effectue le c blage partir du haut on doit s assurer qu il y a suffisamment de mou dans les paires torsad es et que la gaine du c ble ne soit pas dans le champ de terminaison 4 Enfoncer manuellement et d licatement les fils dans les fentes IDC Mettre un percuteur de type 110 au r glage le plus faible et le placer perpendiculairement au connecteur S assurer que les paires restent torsad es jusqu une distance maximale d un peu plus de 1 27 cm des contacts IDC avant de proc der la terminaison coupure des fils En effectuant ainsi la terminaison de chacune des paires apr s les a
4. there is enough slack in the twisted pairs and do not place the cable jacket into the termination field 4 Use your fingers to carefully seat the wires into the IDC slots Set a 110 style impact tool to low impact and position it perpendicular to the connector Maintain wire pair twisting to less than 1 2 of the IDC contact then seat and trim the cable Terminating each pair after placement will prevent crushing the inside pairs with the punchdown tool Lay cable in so that jacket touches rear of connector as shown Figures 1 and 2 5 Place the dust cap over the terminated wires for secure connection 6 Insert connector assembly into platform or wallplate Note the UP position of the connector and orient it accordingly NOTE The wire retention technology in these connectors is so secure Leviton recommends if a terminated cable must be separated from its connector separate it one wire at a time For immediate product information or applications assistance call a Leviton Voice and Data s Technical Support at 1 800 824 3005 International 425 486 2222 Or visit Leviton s website at www levitonvoicedata com Directives d utilisation Connecteurs enclenchables eXtreme 6 et GigaMax 5e DESCRIPTION Ces connecteurs enclenchables eXtreme et GigaMax sont con us pour s adapter aux produits QuickPort de Leviton dans des applications de transmission de la voix de donn es de t l copie et d internet Si ceux de la
5. 1 Building a Connected World eXtreme 6 and GigaMax 5e Snap in Connectors Connecteurs enclenchables eXtreme 6 et GigaMax 5e Conectores Instant neos eXtreme 6 y GigaMax 5e A Division of Leviton Manufacturing Co Inc Technical Support 800 824 3005 Fax 425 483 5270 www levitonvoicedata com Instructions for Use eXtreme 6 and GigaMax 5e Snap in Connectors DESCRIPTION eXtreme 6 and GigaMax M 5e Snap ln Connectors are designed to fit Leviton s QuickPort product line for voice data fax and internet applications Leviton s eXtreme 6 Connectors meet or exceed Category 6 performance levels per TIA 568 B 2 1 similarly GigaMax 5e Connectors meet or exceed Category 5e performance levels per TIA 568 B 2 Featuring universal color wiring labels for T568A and T568B wiring standards these connectors offer dualflexibility in a single connector INSTALLATION 1 Remove about 3 of cable jacket If your cable includes a center spline stiff wire separator inside cable remove it also 2 Determine which wiring scheme T568A or T568B and note the associated color codes on the label located on the connector The label also includes connector pin numbers 3 Leave the cable jacket within 1 8 of the connector side then route the wires for termination using the color code in Table 1 NOTE If wiring from the top ensure
6. cal m iad h URACIONES DE ci ama ocal mojado a menos que los componentes hayan CABLEADO T568A wiring or components 3 Ne jamais toucher des bornes de raccordement ni du sido dise ados especificamente para uso en locales fil non isol s moins que le circuit ne soit pas reli mojados Y Me o dis ai Nunca toque alambres o terminales sin su cubierta a f n doit prenare toutes les precautions requises menos que el cableado haya sido desconectado en el lorsqu on installe ou modifie du c blage ou des com interfaz de la red LEVITON posants de t l communication Use precauci n cuando est instalando o modificando 2222 222nd Street SE Building a Connected World cableado o componentes de comunicaciones Bothell WA 98021 USA Phone 425 485 4288 Fax 425 483 5270 OR 93268 00 00 01 PK 93268 10 02 0A
7. i n 6 Inserte el conector en un marco de pared o en su lugar definitivo Respete la orientaci n del conector la inscripci n UP debe quedar hacia arriba AVISO La tecnolog a de retenci n de cable utilizada en estos conectores es tan segura que si precisa retirar los cables ya conectados por cualquier motivo Leviton le recomienda hacerlo individualmente un conector a la vez Para recibir informaci n inmediata de este producto o asistencia con su aplicaci n contacte a un Ingeniero de Aplicaciones de Leviton Voice y Data en los EE UU llame al 800 824 3005 fuera de los EE UU llame al 425 486 2222 contacte a su distribuidor local o visite nuestra p gina de internet www levitonvoicedata com OR 93268 00 00 01 PK 93268 10 02 0A TABLE 1 TABLEAU 1 TABLA 1 T568A 8 T568B Wiring Standards Modes de c blage T568A et T568B Cableado T568A y T568B IDC Color Assignments Couleurs assign es aux connecteurs IDC Designaci n de Color de Conector IDC IDC Jack Pin T568B T568A Ne de Ne de Colores de Colores de Position Number Wire Colors Wire Colors Position N de Chromocodage Chromocodage Posici n IDC Clavija Cableado T568B Cableado T568A 1 5 White Blue White Blue pS mati T3695 TOGA 1 5 Blanco Azul Blanco Azul 2 4 Blue Blue 1 5 Blanc Bleu Blanc Bleu 2 Azul Azul 3 1 White Orange White Green 2 4 Bleu Bleu 3 1 Blanco Naranja Blanco Verde 4 2 Orange Green 3 1 Blanc Orange Blanc Vert 4 2 Naranja
8. s tinas lavaderos o lavabos fregaderos de 3 Never push objects of any kind into this product through lessive ou un vier de cuisine dans un sous sol humide cocina tinas para lavanderfa dentro de s tanos h medos i ni pr s d une piscine o cerca de piscinas o j e E E N Ne jamais ins rer quelque objet que ce soit dans les 3 Nunca introduzca objetos de ning n tipo a trav s de las 4 SAVE TH ESE INSTRUCTIONS ouvertures de ce dispositif elles sont sous tension et n o a ya que pueden hacer con acto con voltajes pe TAS SAFETY INFORMATION CONSERVER LES PR SENTES a CONSERVE ESTAS 1 Never install communications wiring or components DIRECTIVES INSTRUCCIONES during a lightning storm 2 Never install communications components in wet CONSIGNES DE S CURIT INFORMACI N SOBRE locations unless the components are designed 4 Ne jamais effectuer l installation de c blage ou de SEGURIDAD specifically for use in wet locations icati T568A WIRING METHOD composants de communication pendant un orage ra j 3 Never touch uninsulated wires or terminals unless the 2 Ne jamais installer de composants de communication 1 Nunca a nta 0 e A de comunica MODES DE CABLAGE T568A wiring has been disconnected at the network interface dans des endroits mouill s moins qu il s agisse de y Mu SIAE componentes e a ad UR CONFIG 4 Use caution when installing or modifying communications dispositifs concus sp cialement pour cet usage i i
9. voir plac es on vite d craser les paires centrales avec le percuteur Placer le c ble de mani re ce que la gaine touche l arri re du connecteur tel qu illustr figures 1 et 2 5 Mettre le capuchon pare poussi re sur les terminaisons afin de prot ger les connexions 6 Ins rer le connecteur assembl dans une plate forme ou une plaque murale en orientant la mention UP vers le haut REMARQUE le m canisme de r tention de ces connecteurs est si solide que Leviton recommande de proc der un fil la fois si on doit les d tacher de leur c ble Pour obtenir de l information imm diate sur les produits ou de l aide concernant leurs applications communiquez avec le soutien technique de la division voix et donn es de Leviton en composant le 1 800 824 3005 425 486 2222 linternational ou rendezvous au site www levitonvoicedata com 61110 RX6 5G110 RX5 Instrucciones de uso Conectores Instant neos eXtreme 6 y GigaMax 5e DESCRIPTION Los Conectores Instant neos eXtreme 6 y GigaMax 5e est n dise ados para calzar en cualquier producto de la l nea QuickPort de Leviton en aplicaciones de voz data fax e internet Los conectores eXtreme 6 de Leviton cumplen o exceden las normas de Categor a 6 de acuerdo a los niveles de desempe o establecidos por TIA 568 B 2 1 de la misma manera los conectores GigaMax 5e cumplen o exceden las normas de Categor a 5 de acuerdo a los niveles de desempe o