Home

Aeon Labs Minimote Black

image

Contents

1. Mode of Button 5 marked as Include Parameter Number 245 Parameter Size 1 Defines the switching mode of Button 5 Value Description c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lovs 0 Factory Default Default 1 Scene Mode 2 Add Mode 3 Remove Mode 4 Association Mode 5 Learn Mode Mode of Button 6 marked as Exclude Parameter Number 246 Parameter Size 1 Defines the switching mode of Button 6 Mode of Button 7 marked as Association Parameter Number 247 Parameter Size 1 Defines the switching mode of Button 7 3 Remove Mode 4 Association Mode 5 Learn Mode Mode of Button 8 marked as LEARN Parameter Number 248 Parameter Size 1 Defines the switching mode of Button 8 Value Description 0 Factory Default Default 2 Add Mode 3 4 Association Mode 6 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lovs 5 Learn Mode Technical Data Explorer Frame Support SDK Device Type Generic Device Class Specific Device Class Routing FLIRS Firmware Version Yes 4 50 beta Slave with routing capabilities Binary Switch Binary Power Switch Yes No 1 0 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com
2. To become primary a contoller have to be resetted and then include a device Exclude device from network The primary controller can exclude devices from the Z Wave network During exclusion the relationship between the device and the network of this controller is terminated No communication between the device and other devices still in the network can happen after a successful exclusion The controller needs to be turned into the exclusion mode Once in this exclusion mode the other device needs to confirm the exclusion typically by pressing a button Attention Removing a device from the network means that it is turned back into factory default status This process can also exclude devices from it s previous network Click the Exclusion button to start the exclusion mode Attention Removing a device from the network means that it is turned back into factory default status This process can also exclude devices from its previous network c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lows Shift Primary Role to a different Controller The device can hand over its primary role to another controller and become secondary controller The primary shift is initiated on the device by pressing the Learn button Set association between two device in Z Wave network CA The controller is able to set association between two other devices in the network The controller is turned into an as
3. ingle or triple click a button Please refer to the manual of this device how to issue a NIF 3 Before releasing the scene button turn the device into the desired state After the button is released the minimote will detect the status of the device and store it in the scene To delete a device from a scene repeat the process for the scene where the device was already associated with Special Functions as Z Wave Controller As long as this device is not included into a Z Wave network of a different controller it is able to manage its own Z Wave network as primary controller As a primary controller the device can include and exclude other devices in its own network manage associations and reorganize the network in case of problems The following controller functions are supported Include other device in own network Cl Communication between two Z Wave devices only works if both belong to the same wireless network Joining a network is called inclusion and is initiated by a controller The controller needs to be turned into the inclusion mode Once in this inclusion mode the other device needs to confirm the inclusion typically by pressing a button Click the Inclusion button to start the inclusion mode If inclusion of a new device fails first exclude it from its previous network or reset it If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices
4. ller Wakeup Intervals how to communicate with the device Ww This device is battery operated and turned into deep sleep state most of the time to save battery life time Communication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device The device can be woken up manually by pressing the Learn button for 5 seconds It is possible to set the node ID to 255 to send wakeup notifications as broadcast In this mode device takes more time to go to sleep and drains battery faster but can notify all it s direct neighbors about a wakeup Node Information Frame NIF The Node Information Frame is the business card of a Z Wave device It contains inf
5. lows e AEO_MREM_B Aeonlabs Minimote black Firmware Version 1 0 Quick Start E This device is a Z Wave Remote Control Use Network Management Buttons to include and exclude devices to the remote controls network and use the LEARN button to include the minimote into a different network Pushing the LEARN button for 5 sec will wake up the device Please refer to the chapters below for detailed information about all aspects of the products usage Product description The Aeon Labs mini remote control can control a variety of Z Wave compatible devices such as switches dimmers window blinds and motion sensors The device can include and exclude devices group them and set and release associations The mini remote only offers four control buttons for scene selection Behind a slider there are four more buttons for Z Wave network control A non replaceable but rechargeable battery powers the remote control Recharging is done on a conventional USB bus using the charging cable provided The product is in the color black Installation Guidelines The device is ready for use In case there are no LED signals when hitting the buttons the device needs to be recharged using the USB cable provided c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lows Behavior within the Z Wave network l On factory default the device does not belong to any Z Wave network The device needs to j
6. oin an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Once the primary controller is turned into inclusion mode press the Learn button Operating the device The Minimote has 4 scene control buttons A scene defines a certain switching state for a number of devices connected to this scene A single click on the scene button will then turn all these devices into the desired switching state Below the cover there are 4 dedicated buttons for network management The Minimote can manage a Z Wave network as primary controller However it is also possible to reconfigure all 8 buttons for other functions e g activating a scene in a different contro
7. ormation about the device type and the technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame A single click at the Learn button for 5 seconds sends a Node Information Frame Associations A Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com 1 Scene 1 max nodes in group 5 2 Scene 2 max nodes in group 5 3 Scene 3 max nodes in group 5 4 Scene 4 max nodes in group 5 Set and unset associations to actuators Associations can be assigned and remove either via Z Wave commands or using the device itself SA 1 Press the scene button the new device shall be associated with and keep this button pressed 2 Issue a Node Information Frame from the target device This is usually done by s
8. rn together for 10 seconds to reset the device Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Mode of Button 1 upper left Parameter Number 241 Parameter Size 1 Defines the switching mode of Button 1 Value Description 0 Factory Default Default 1 Scene Mode 2 Add Mode E 3 Remove Mode 4 Association Mode E 4 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lovs 5 Learn Mode Mode of Button 2 upper right Parameter Number 242 Parameter Size 1 Defines the switching mode of Button 2 3 Remove Mode 4 Association Mode 5 Learn Mode Mode of Button 3 lower left Parameter Number 243 Parameter Size 1 Defines the switching mode of Button 3 Mode of Button 4 lower right Parameter Number 244 Parameter Size 1 Defines the switching mode of Button 4 3 Remove Mode 4 Association Mode 5 Learn Mode
9. sociation mode both devices are announced by pressing a button After both association partners are known the controller will perform all necessary steps to set the association 1 Press Association button 2 Issue a Node Information Frame from the target device This is usually done by single or triple click a button Please refer to the manual of this device how to issue a NIF 3 Issue a Node Information Frame from the device where the association will be set This is usually done by single or triple click a button Please refer to the manual of this device how to issue a NIF Update Network Information As a battery operated controller the device will not automatically received updates about the network structure This process should be initiated when the primary controller has included excluded devices and it will result in an update of the network information in the battery operated controller This prevents wrong communication that may cost battery life and delay other communication Press the button Association for 10 seconds to update the network it is possible that a network update fails if the network was changed too much after the last update In this case the the device need to be reincluded Re Inclusion is similar to a normal inclusion Its just not needed to exclude the device before Re Inclusion makes sure that the node ID of the device remails unchanged Reset the Controller Press the buttons Association and Lea

Download Pdf Manuals

image

Related Search

Related Contents

を押す - 日立の家電品  Outil centralisé de Gestion des stages  Termómetro infrarrojo para alta temperatura  HS 1300 - Hearing Direct  DVD Amaray Book - Cengage Learning  PDFファイル  SCPH-50003 - PlayStation  取扱説明書 - イメージニクス  Baumatic BHS600.5SS hob  

Copyright © All rights reserved.
Failed to retrieve file