Home
Aeon Labs Z-Wave
Contents
1. Aeotec will pass on to Customer all manufacturers Material warranties to the extent that they are transferable but will not independently warrant any Material Customer must prepay shipping and transportation charges for returned Products and insure the shipment or accept the risk of loss or damage during such shipment and transportation Aeotec will ship the repaired or replacement products to Customer freight prepaid Customer shall indemnify defend and hold Aeotec and Aeon Labs affiliates shareholders directors officers employees contractors agents and other representatives harmless from all demands claims actions causes of action proceedings suits assessments losses damages liabilities settlements judgments fines penalties interest costs and expenses including fees and disbursements of counsel of every kind i based upon personal injury or death or injury to property to the extent any of the foregoing is proximately caused either by a defective product including strict liability in tort or by the negligent or willful acts or omissions of Customer or its officers employees subcontractors or agents and or ii arising from or relating to any actual or alleged infringement Or misappropriation of any patent trademark mask work copyright trade secret or any actual or alleged violation of any other intellectual property rights arising from or in connection with the products except to the extent th
2. AEOTEC BY AEON LAI Aeotec Home Energy Meter Z Wave Home Energy Meter 2nd Edition You hear a lot about energy use these days About how if we reduce the amount of energy we use we can not only save money but also save the environment But saving money by using less electricity is only possible if we understand when and how we use it That s what the Aeotec Home Energy Meters provide you with understanding Installed in an electricity box the energy meter will monitor the total consumption of electricity used by an entire building And its intelligent clamps will report that energy use back to your control point in watts or kilowatt hours and in real time So you can see how much electricity you really use and when you use it Quick Start The installation of your Aeotec Home Energy Meter has two major parts the installation of the meter into your Z Wave network and the installation of it into your AC mains electricity box What follows are the instructions for both parts The electrical installation of your meter into your circuit box should only be done with a licensed electrician with knowledge and understanding of electrical systems and electrical safety You can perform the second half of the installation process yourself by linking the meter with your Z Wave network Installing meter into circuit box Important Only a licensed electrician should perform these steps Unless o
3. purchaser of Products that for the Warranty Period as defined below the Products will be free from material defects in materials and workmanship The foregoing warranty is subject to the proper installation operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer Warranty claims must be made by Customer in writing within thirty 30 days of the manifestation of a problem Aeon Labs sole obligation under the foregoing warranty is at Aeon Labs option to repair replace or correct any such defect that was present at the time of delivery or to remove the Products and to refund the purchase price to Customer The Warranty Period begins on the date the Products is delivered and continues for 12 months Any repairs under this warranty must be conducted by an authorized Aeotec service representative and under Aeon Labs RMA policy Any repairs conducted by unauthorized persons shallvoidthis warranty Excluded from the warranty are problems due to accidents acts of God civil or military authority civil disturbance war strikes fires other catastrophes misuse misapplication storage damage negligence electrical power problems or modification to the Products or its components Aeotec does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein
4. If your meter has been successfully removed from your network its light will blink for 3 seconds If the removal was unsuccessful the light will be solid after pressing the Action Button of your meter and it will be then repeated again Associating the Home Energy Meter to Report Automatically Aeotec Home Energy Meter can send Wattage and KWh to associated devices Todothis Please refer to main controller s manual Monitoring Energy Consumption The Aeotec Home Energy Meter can report wattage energy usage or kWh energy usage toa control point when requested If this function is supported by the controller point the energy consumption will be displayed in the user interface of the control point The specific Z Wave commands supporting energy monitoring are the Meter Command Class Please consult the operation manual for these control points for specific instructions on monitoring the Home Energy Meter Technical Specifications Model number DSB28 ZWUS DSB28 ZWXX xx indicate area Input 120V 60Hz 10mA USAversion 2P 230V 50Hz 10mA others 1P 3P4 380V 50Hz 18mA others 3P3 Measure range of voltage 80V to 150V USAversion 2P 180V to 260V others 1P 3P4 220V to 400V others 3P3 Measure range of current OA to 200A Operating distance Up to 100 feet 30 meters indoors and 300 feet 100 meters outdoors Warranty Aeotec warrants to the original
5. NG Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available Certifications Note CeO FCC ID XBADSB28 symbols Double insulation AN Caution risk of danger D CONFORMS TO UL STD 61010 1 CERFIFIED TO CSA STD C22 2 NO 61010 1 IEC 61010 2 032 This product has been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements lt AN wy Intertek 4005555 Version 501002800001 AC www aeotec com AEOTEC BY AEON LABS
6. UIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may Cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help WARNI
7. X 200A Phase B Neutral Neutral Bus Blue Phase B Brown Phase C AC Power Brown Phase A Diagram of EU AU version 3 phases 4 wires Incoming Power Lines 180V to 260V MAX 200A CI directi amp direction NE Main Circuit Breaker Phase C MAX 200A Phase B 2 Neutral Phase A 3 3 Neutral Bus HEM Blue Neutral Brown Phase C Brown Phase B AC Power Brown Phase A 1 Important Turn off the main breaker and open the main circuit box panel 2 Clip the clamps of the meter around the incoming electricity cables that connect to the main circuit breaker 3 Connect the clamp to the meter using a Clamp Connector 4 Connect the AC Wire to the meter using the AC Wire Connector option 5 Insert one of the AC Power exposed wires into one of the neutral bus terminals and the other exposed wire into the live terminals coming from the main circuit breaker 6 Replace the main circuit box panel 7 Turn the main breaker back on You can now place the main body of the Home Energy Meter Inside the meter is a radio antenna used for communications which must be taken into consideration when selecting a location for the meter If the circuit boxes are made of metal radio signal strength may be reduced In this situation it is recommended that the main body of the mete
8. at such infringement exists as a result of Aeon Labs manufacturing processes IN NO EVENT SHALL AEOTEC BE LIABLE FOR ANY INDIRECT INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES OR DAMAGES FOR LOSS OF PROFITS REVENUE OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY WHETHER IN AN ACTION IN CONTRACT OR TORT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AEON LABS LIABILITY AND CUSTOMER S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS WHETHER BASED ON NEGLIGENCE STRICT LIABILITY BREACH OF WARRANTY BREACH OF AGREEMENT OR EQUITABLE PRINCIPLES IS EXPRESSLY LIMITED TO AT AEON LABS OPTION REPLACEMENT OF OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY 30 DAYS FROM AEON LABS S DELIVERY OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE FCC NOTIC For USA THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQ
9. r be affixed outside the circuit box This will improve the radio signal strength The Home Energy Meter 2nd Edition has been weatherized to the international IP44 standard so that itis resistant to rain and snow when placed vertically with the wires protruding fromthe bottom oftheunit To place the Home Energy Meter 1 Slip open the backing plate from the back of your meter 2 Affix the plate to the selected wall space using the provided screws 3 Attach your meter to the backing plate Linking the meter with an existing Z Wave network After an electrician connects your Home Energy Meterto your electrical mains you should link the meter to your Z Wave network through the followingsteps 1 Refer to your main controller s manual and let the main controller into include mode 2 Press the Home Energy Meter button If your meter has been successfully linked to your network its light will remain solid for 3seconds If the linking was unsuccessful the light will blink after the Action Button of your meter has been pressed and will then be repeated again Removing your meter from a Z Wave network Your meter can be removed from your Z Wave network at any time You ll need to use the main controller in your Z Wave network to do this throughthe following steps 1 Refer to your main controller s manual and let the main controller into device removable mode 2 Press Home Energy Meter button
10. therwise stated the circuit box s main breaker should be turned off to perform these installation steps Diagram of USA version 2 phases Incoming Power Lines Fa l 80V to150V MAX 200A f x ae Clamp direction Clamp direction Main Circuit Breaker ivez MAX 200A Live1 Neutral Bus 7 Neutral Neutral AC Power NOTE The plug must plug into Live1 s socket NOTE If you cannot find a socket ask your electrician for help on wiring 19 Clamp direction Incoming Power Lines 80V to150V MAX 200A So Clamp direction Main Circuit Breaker MAX 200A Neutral Live2 Live1 TTI LILLY Neutral Bus oooo00000000 R Vas Neutral Blue Live Brown AC Power Diagram of EU AU version 1 phase Incoming Power Lines l i re 180V to 260V Clamp direction MAX 200A AC Power Diagram of EU AU version 3 phases 3 wires Ss Incoming Power Lines 220V to 400V MAX 200A r Oooo Clamp direction S Main Circuit Breaker Phase C MA