Home
        Fibaro FGFS-101
         Contents
1.                 12 24 VDC  ADAPTER                      Fig  2   Connection to a constant power source                                                             Fig  3   Flood sensor   s contacts  extended with a wire    Fig  4   Probes marking       Vil  OPERATING THROUGH THE Z WAVE NETWORK    Fibaro Flood Sensor has two sensors built in   flood and temperature sensors   meaning it   s a multichannel device  In the Z Wave network   s main controller the  Sensor will be shown as two devices     Flood Sensor Flood Sensor Temp  XX       Fig  5 Flood Sensor icon in HOME CENTER 2    VIII  ASSOCIATIONS    Through an association Fibaro Flood Sensor may control another Z Wave network  device  e g  a Dimmer  Relay Switch  Roller Shutter  RGBW Controller  Wall Plug   or a scene  scene only through the Home Center 2 main controller         NOTE   Association allows for direct communication between Z Wave   network devices  Main controller does not take part in such   1 communication  Using this mechanism  Fibaro Flood Sensor may  communicate with other devices even when the main controller is  damaged  e g  in a fire        Fibaro Flood Sensor allows for the associations of three groups   1 st Association Group is assigned to the device status   sending the BASIC SET   default  or ALARM control frame to the associated devices     2 nd Association Group is assigned to a TMP button and tilt sensor   ALARM  GENERIC control frame will be sent to the associated devices in case a TMP  butt
2.           z  a    OPERATING MANUAL  FLOOD SENSOR  FGFS 101 EN A v1 00    Fibaro Flood Sensor is a universal  Z Wave compatible  flood and temperature  sensor  Device can be battery  ca  2 years battery life  or VDC powered  12 or 24  VDC   Flood alarm is sent to the Z Wave network devices or additionally to any  alarm system controller  through opening a NC contact    The device has built in temperature sensor  monitoring temperature of e g  floor   Fibaro Flood Sensor is designed to be placed on the floor or on a wall with a flood  sensor probe extended by connected wire  The device has built in LED indicator  and acoustic alarm  In addition  the sensor is equipped with a tilt sensor reporting  tilt or movement to the main controller e g  when someone has taken the Sensor  from its original location  LED diode signals flood  operating mode or the Z Wave  network communication range  Fibaro Flood Sensor is sink proof  which means it  drifts on the water surface and keeps on sending alarm signal in case of  substantial inundation of water     SPECIFICATIONS    Power Supply  12   24 VDC  Battery Type  CR123A   Power Consumption  at VDC operation   0 4W   Output terminals maximum current 25mA   carrying capacity    ALARM NC  TAMP NC     Maximum voltage at output terminals  24V DC   20V AC    EU standards compliance  EMC 2004 108 EC    R amp TTE 1999 5 WE    Radio protocol  Z   Wave   Radio frequency  868 4 MHz EU   908 4 MHz US   921 4 MHz ANZ   869 2 MHz RU    Range  up to 50m 
3.       7  When the guarantee claim form is submitted correctly  a representative of the  Authorised Guarantee Service  hereinafter as  AGS   shall contact the Customer     8  Defects revealed within the guarantee period shall be removed not later than 30 days  from the date of delivering the Device to AGS  The guarantee period shall be extended  by the time in which the Device was kept by AGS     9  The faulty device shall be provided by the Customer with complete standard  equipment and documents proving its purchase     10  Parts replaced under the guarantee are the property of the Manufacturer  The  guarantee for all parts replaced in the guarantee process shall be equal to the guarantee  period of the original device  The guarantee period of the replaced part shall not be  extended     11  Costs of delivering the faulty device shall be borne by the Customer  For unjustified  service calls  the Service may charge the Customer with travel expenses and handling  costs related to the case     12  AGS shall not accept a complaint claim only when      the Device was misused or the manual was not observed      the Device was provided by the Customer incomplete  without accessories or  nameplate      it was determined that the fault was caused by other reasons than a material or  manufacturing defect of the Device     the guarantee document is not valid or there is no proof of purchase     13  The Manufacturer shall not be liable for damages to property caused by defective  device
4.   The Manufacturer shall not be liable for indirect  incidental  special  consequen   tial or punitive damages  or for any damages  including  inter alia  loss of profits  savings   data  loss of benefits  claims by third parties and any property damage or personal  injuries arising from or related to the use of the Device     14  The guarantee shall not cover      mechanical damages  cracks  fractures  cuts  abrasions  physical deformations caused  by impact  falling or dropping the device or other object  improper use or not observing  the operating manual       damages resulting from external causes  e g   flood  storm  fire  lightning  natural  disasters  earthquakes  war  civil disturbance  force majeure  unforeseen accidents   theft  water damage  liquid leakage  battery spill  weather conditions  sunlight  sand   moisture  high or low temperature  air pollution      damages caused by malfunctioning software  attack of a computer virus  or by failure to  update the software as recommended by the Manufacturer      damages resulting from  surges in the power and or telecommunication network   improper connection to the grid in a manner inconsistent with the operating manual  or  from connecting other devices not recommended by the Manufacturer      damages caused by operating or storing the device in extremely adverse conditions  i e   high humidity  dust  too low  freezing  or too high ambient temperature  Detailed  permissible conditions for operating the Device are def
5.   see main controllers operating manual     2  Set the main controller into the learning mode    3  Triple click TMP button    4  Fibaro Flood Sensor will be detected and included     Ill  Z WAVE NETWORK EXCLUSION    Complete the following steps to exclude a Fibaro Flood Sensor from the Z Wave  network     1  Remove sensor s cover    2  Make sure sensor is connected to a battery or a DC power supply    3  Set a main controller into learning mode  see main controllers operating  manual     4  Triple click TMP button  located inside Flood Sensor   s casing     IV  SENSOR   S INSTALLATION    1  Remove top cover    2  Include into the Z Wave network  see pt  II     3  Place sensor onto a surface prone to flooding  All three electrodes underneath  the device should evenly touch the surface    4  If the sensor is to be DC powered  drill holes in it s casing and connect wires  observing the wiring diagram no 2    5  Close sensor s casing        NOTE   After completing installation it s recommended to test sensor s  operation by placing the entire sensor or it   s probes    extension wire  onto water surface        NOTE   The Sensor detects resistance  under 4MOhm  between  electrodes 1 and 3  1 and 2  according to scheme no 4   and  electrodes connected to contacts  SENS1 and SENS2         e NOTE  1 Contacts SENS1 and SENS2 are dedicated to flood detection  only  Do not connect external voltage           NOTE   When changing the Sensor s location  it s recommended to wake  up the de
6.   the location of its individual components is automatically updated in real time  through status confirmation signals received from devices operating in a  mesh   network     Il  Z WAVE NETWORK INCLUSION    Use TMP button to include the Fibaro Flood Sensor into the Z Wave network  In  addition  the device may be included into the Z Wave network in auto inclusion  mode  at connecting a DC power source  mode active only after the built in battery  has been disconnected      Including the Fibaro Flood Sensor using auto inclusion mode     1  Make sure a DC power source is disconnected and the sensor is located within  direct communication with the main controller s range  The battery must be  removed    2  Open the cover    3  Set the main controller into the learning mode  see a main controller   s operating  manual     4  Connect a DC power source to include the Fibaro Flood Sensor into the Z Wave  network in autoinclusion mode    5  Fibaro Flood Sensor will be detected and included        NOTE  e In case the Sensor is not detected  proceed to the manual  1 inclusion  described below  or reset the Sensor and repeat auto    inclusion procedure        To deactivate auto inclusion mode  press TMP button once  after the Fibaro Flood  Sensor has been connected to a DC power supply     Manual Z Wave network inclusion     1  Connect a DC power supply to the Fibaro Flood Sensor or insert a battery   Make sure the sensor is located within the Z Wave network   s main controller s  range
7.  sent to 2 nd Association Group activation   MOVEMENT_TAMPER   BUTTON_TAMPER   1 byte     Available settings    0   tamper alarms inactive   1   button tamper alarm active   2   movement tamper alarm active   3   button and movement tampers alarm active  Default setting  2   Parameter size  1  byte     The device is able to turn on alarms resulting from sensor s vibrations e g  when  the sensor is moved  or the TMP button released  2 nd Association Group alarms  are not cancelled     75  Visual and audible alarms duration    The user can silence the Flood Sensor  Because the Sensor   s alarm may last for  a long time  it s possible to turn off visual and audible alarm signaling to save  battery     Available settings  0   65535  each 1 second   Default setting  0  Parameter size  2  bytes     The parameter determines a time period after which alarm will become    quiet       still active but the device will go into battery saving mode  Visual or acoustic alarm  will be reactivated after time period specified in the Parameter 76  When alarm  status ceases  alarm will be turned off immediately     The value of 0 means visual and acoustic alarms are active indefinitely  In battery  power mode the Sensor will never go to sleep which may shorten battery life  significantly                       NOTE  s The main controller does not interpret negative numbers as  1 decimals  That s why read value may be different than entered   Negative numbers are coded in U2 standard   Decimal Hex
8. adecimal  U2  Value in main controller  32767 0x7FFF 32767  1 0x0001 1  0 0x0000 0   1 OxFFFF 65535   10000 OxD8FO 55536   32768 0x8000 32768                   61  Low temperature alarm indicator colour  Parameter stores RGB colour value    Available settings  0   16777215   Default setting  255  blue 0x000000FF   Parameter size  4  bytes        e NOTE  1 A main controller interprets colours as a sum of it component  colours value  Each colours value is a number from 0 to 255        Example   Indicated colour   65536   RED value   256   GREEN value   BLUE value    62  High temperature alarm indicator colour  Parameter stores RGB colour value    Available settings  0   16777215   Default setting  16711680  red 0x00FF0000   Parameter size  4  bytes        a NOTE  A main controller interprets colours as a sum of it component  1 colours value  Each colours value is a number from 0 to 255        Example   Indicated colour   65536   RED value   256   GREEN value   BLUE value    Ld NOTE  1 The parameter is ignored when Parameter 2 is set to 0        76  Alarm frame   Basic Set frame retransmission time when retaining flood  alarm    Parameter determines a time period after which an alarm frame will be retransmit   ted  The value of 0 cancels an alarm frame retransmission     Available settings  0   65535  each 1 second     Default setting  0  Parameter size  2  bytes        NOTE  bed In case a time period set in this parameter is shorter than the one  1 specified in parameter 75  th
9. ate i e  30      9  Alarm cancelling or turning a device off  Basic  command frame  deactivation     Allows for deactivating device turn off and alarm cancellation functions for the  devices assigned to 1 st association group  1 byte      Setting the parameter s value to 0 results in stopping BASIC SET   0 or ALARM  WATER   0 control frames from being sent  After sending flood alarm report the  device will keep on reporting flooding after the flooding itself has ceased  Such a  state can be cancelled by choosing alarm cancelation from the MENU  marked  with green LED colour     Available settings    0   alarm  flooding  cancellation inactive  1   alarm  flooding  cancellation active  Default setting  1   Parameter size  1  byte     10  Temperature measurement interval    Time interval  in seconds  between consecutive temperature measurements done  by built in temperature sensor  New temperature value is reported to the main  controller if it differs from the previously measured by hysteresis  defined in  parameter 12      Available settings  1   65535  in seconds   Default setting  300  5 minutes   Parameter size  2  bytes     The parameter determines time interval  in seconds  at which a Flood Sensor  measures and reports ambient temperature and battery level    If a temperature value will differ from previously reported by a value determined in  parameter 12  e g  P12   50  i e  temperatures differ by 0 50C   new temperature  value will be reported  If a battery level chang
10. d  62 settings    4  Currently chosen MENU position is signaled with an illumination colour    Press and hold the TMP button for at least 3 seconds to enter MENU  Inside    MENU  each of the positions will be signaled by another LED colour     WHITE   entering MENU confirmation   GREEN   cancel alarm for associated devices   PINK   Z Wave network   s range test   YELLOW   sensor reset     X  CANCEL ALARM FOR ASSOCIATED DEVICES    It s possible to cancel alarm for associated devices simply by entering MENU    signaled by GREEN illumination     XI  Z WAVE RANGE TEST    Fibaro Flood Sensor has a built in the Z Wave network main controller s range  tester  Follow the following instructions to test the main controller   s range     1  Press and hold a TMP button for 10   15 seconds  until a LED indicator colour  changes to violet    2  Release the TMP button    3  Click the TMP button    4  LED indicator will signal the Z Wave network range  see description below     5  To exit the Range Tester click the TMP button    Z Wave Range Tester signaling modes    LED Indicator pulsing green   Fibaro Flood Sensor attempts to directly  communicate with the main controller  If the direct communication attempt fails  the  sensor will try routed communication  through other devices  which will be signaled  with LED Indicator blinking yellow     LED Indicator glowing green   Fibaro Flood Sensor directly communicating with  the main controller     LED Indicator pulsing yellow   Fibaro Flood Sen
11. e and should be compatible with such devices produced  1 by other manufacturers    Any device compatible with Z Wave may be added to Fibaro system        FIBARGROUP  FIBARO    In case of any technical questions contact customer service centre in your country     www fibargroup com    
12. e device will not quiet the alarm  it will    remain active        77  Flood sensor functionality turned off    Allows for turning of the internal flood sensor  Tamper and built in temperature  sensor will remain active     Available settings    0   Default flood sensor operation  flood detection  reactions    1   Built in flood sensor TURNED OFF  doesn   t change its state in the main  controller  doesn   t send Alarms and Basic Set frames with flood state changes   Always visible in the main controller as turned off    Default setting  0   Parameter size  1  byte     XV  GUARANTEE    1  The Guarantee is provided by FIBAR GROUP Sp  z o o   hereinafter   Manufacturer    based in Poznan  ul  Lotnicza 1  60 421 Poznan  entered in the  register of the National Court Register kept by the District Court in Poznan  VIII  Economic Department of the National Court Register  no  370151  NIP  7811858097  REGON  301595664     2  The Manufacturer is responsible for equipment malfunction resulting from physical  defects  manufacturing or material  of the Device for 12 months from the date of its  purchasing     3  During the Guarantee period  the Manufacturer shall remove any defects  free of  charge  by repairing or replacing  at the sole discretion of the Manufacturer  any  defective components of the Device with new or regenerated components  that are free  of defects  When the repair impossible  the Manufacturer reserves the right to replace the  device with a new or regenerated one  
13. es  the device will report a battery  status change   Battery Report    The parameter is relevant when using a Flood Sensor in a battery power mode    longer time interval means less frequent communication resulting in extended  battery life    After consecutive FAILED and SUCCESSFUL communication attempts  the  Sensor will go to standby mode     12  Temperature measurement hysteresis   Determines a minimum temperature change value  insensitivity level   resulting in  a temperature report being sent to the main controller  according to the Parameter  10 settings     Available settings  1   1 000  each 0 010C    Default setting  50  0 5  C    Parameter size  2  bytes    13  Alarm BROADCAST   Value other than 0 means alarms are sent in BROADCAST mode  with a priority  over other communicates   to all devices within the Fibaro Flood Sensor   s range     Available settings    0   broadcasts inactive   1   flood  1 st Association Group  broadcast active  tamper  2 nd Association  Group  broadcast inactive   2   flood broadcast inactive  tamper broadcast active   3   flood broadcast active  tamper broadcast active   Default setting  0   Parameter size  1  byte    50  Low temperature alarm threshold   Available settings    10 000 to  10 000  each 0 01  C    Default setting  1 500  15 00  C    Parameter size  2  bytes    The parameter stores a temperature value  below which LED indicator blinks with   a colour determined by a Parameter 61 settings  By default the LED indicator   blin
14. extreme cases it fails to transfer required data  The advantage of  Fibaro System is that its devices  apart from being transmitters and signal  receivers  also duplicate signal  When a direct connection path between the  transmitter and the receiver cannot be established  the connection may be  achieved through other intermediate devices    Fibaro is a bi directional wireless system  This means that the signal is not only  sent to the receivers but also the receivers send the confirmation of its reception   This operation confirms their status  which checks whether they are active or not   Safety of the Fibaro System transmission is comparable to the safety of  transmission in data bus wired systems    Fibaro operates in the free bandwidth for data transmission  The frequency  depends on radio regulations in individual countries  Each Fibaro network has its  own unique network identification number  home ID   which is why it is possible to  co operate two or more independent systems in a single building without any  interference    Although Z Wave is quite a new technology  it has already become recognized and  officially a binding standard  similarly to Wi Fi  Many manufacturers in various  industries offer solutions based on Z Wave technology  guaranteeing their  compatibility  This means that the system is open and it may be extended in the  future  Find more information at www fibaro com    Fibaro generates a dynamic network structure  After Fibaro System is switched on 
15. ined in the operating manual      damages caused by using accessories not recommended by the Manufacturer     damages caused by faulty electrical installation of the Customer  including the use of  incorrect fuses      damages caused by Customer s failure to provide maintenance and servicing activities  defined in the operating manual      damages resulting from the use of spurious spare parts or accessories improper for  given model  repairing and introducing alterations by unauthorized persons      defects caused by operating faulty Device or accessories     15  The scope of the guarantee repairs shall not include periodic maintenance and  inspections  in particular cleaning  adjustments  operational checks  correction of errors  or parameter programming and other activities that should be performed by the user   Buyer   The guarantee shall not cover natural wear and tear of the Device and its  components listed in the operating manual and in technical documentation as such  elements have a defined operational life    16  If a defect is not covered by the guarantee  the Manufacturer reserves the right to  remove such defect at its sole discretion  repairing the damaged or destroyed parts or  providing components necessary for repair or replacement    17  This guarantee shall not exclude  limit or suspend the Customer rights when the  provided product is inconsistent with the purchase agreement        This Device may be used with all devices certified with Z Wave  certificat
16. ks blue    51  High temperature alarm threshold   Available settings    10 000 to  10 000  each 0 01  C    Default setting  3 500  35  C    Parameter size  2  bytes    The parameter stores a temperature value  above which LED indicator blinks with    a colour determined by the Parameter 62 settings  By default the LED indicator  blinks red                                         Colour Decimal value  Red 16711680  Green 65280  Blue 255  Yellow 16776960  Turquoise 65535  Orange 16750848  White 16777215  LED indicator turned off 0                63  Managing a LED indicator under standard operation    Parameter determines LED indicator   s operation  Set to 0 turns the indicator off   saving a battery life     Available settings    0   LED indicator doesn t indicate the temperature   1   LED indicator indicates the temperature  blink  every Temperature  Measurement Interval  Parameter 10  constant current and battery  or Wake  Up Interval  battery mode    2   LED indicator indicates the temperature continuously  only in constant power  mode     Default setting  2  Parameter size  1  byte     73  Temperature measurement compensation    Available settings   10 000 to  10 000  Default setting  0  0 000C   Parameter size  2  bytes     Parameter stores a temperature value to be added to or deducted from the current  temperature measured by internal temperature sensor in order to compensate the  difference between air temperature and temperature at the floor level     74  Alarm frame
17. o 3 are not included in the  package  Choose a screw type depending on the building material  it is being attached to        DIAGRAMS    DESCRIPTION     12V   12   24 VDC positive terminal    GND   negative  ground  terminal   ALARM NC   potential free flood sensor terminals  for wired systems   TAMP NC   potential free tamper terminals  for wired systems   SENS1  SENS2   flood sensor electrodes    terminals        e NOTE  1 ALARM NC and TAMP NC connectors may be used as EOL  protective loop   s terminals        VI  FIBARO FLOOD SENSOR RESET    Reset procedure deletes EPROM s memory  including all information on the  Z Wave network and the main controller     Fibaro Flood Sensor s reset procedure    1  Make sure the Sensor is powered    2  Press and hold a TMP button for 15   20 seconds  LED indicator glows yellow to  confirm entering 4th sub menu    3  Release the TMP button    4  Click the TMP button  once    The LED indicator glowing red and then turning off will confirm a successful reset    Reset completion will be confirmed by an acousic signal  same as at the power   source connection        NOTE  bss Reset procedure doesn   t remove the Sensor from the Z Wave  1 network   s main controller memory  Prior to reset  a sensor must be    deleted from the Z Wave network                 ALARM  SYSTEM HUB    AUX COM Z1 Z2                                                                                         Fig  1   Connection with alarm system                TMP            
18. on is released or a tilt sensor triggered  depending on parameter 74 settings     3 rd Association Group reports the device status and allows for assigning single  device only  the main controller by default   the device reports its status to the main  controller      Fibaro Flood Sensor allows for controlling 5 regular and 5 multichannel devices per  an association group  out of which 1 field is reserved for the Z Wave network main  controller    To add an association  using Home Center 2 interface  go to device settings and  click the following icon  a    Select the    device options    tab  Then specify to which group and what devices are  to be associated  Sending relevant information to devices that have been added to  association groups may take even a few hours depending on configuration  parameters    settings     IX  LED VISUAL SIGNALS AND SETTINGS    Fibaro Flood Sensor is equipped with a LED diode  signaling sensor   s operating  modes and alarms  In addition the LED indicator may inform of the Z Wave  network range and the current temperature     LED indicator signaling modes    1  Flood alarm is signaled with alternating white and blue light    2  In battery powering mode  with parameter no 63 set to 1  LED indicator will  periodically show temperature readouts  depending on parameters 50  51  61 and  62 settings    3  In constant powering mode  the current temperature readouts will be  continuously signaled with a colour depending on the parameters 50  51  61 an
19. outdoors    up to 30m indoors   Depending on terrain  and building structure     Operational Temperature  0   40  C     Measured temperature range   20 to 100  C    Temperature measuring accuracy  0 5  C  within 0   40  C range     Dimensions  Diameter x Height   72 x 28mm      Operational temperature in VDC powering mode   20  C   70  C    TECHNICAL INFORMATION      Compatible with any Z Wave network controller      May be connected to any alarm system  potential free output terminal       Extremely easy installation   simply put on a surface prone to flooding      May be installed anywhere   flood sensor s contacts extended with a wire      Battery or VDC powered  When connected to an external  VDC power source  the  battery serves as an emergency power source      Theft protection   tilt is reported to the Z Wave network or alarm system s main  controller      Two operating modes   flood   temperature sensor or just a temperature sensor        NOTE  e Connect while observing wiring diagram shown in this manual  1 only  Incorrect wiring may be dangerous or result in the device  breakdown        Il  GENERAL INFORMATION ABOUT FIBARO SYSTEM    Fibaro is a wireless system  based on Z Wave technology  Fibaro provides many  advantages when compared to similar systems  In general  radio systems create a  direct connection between the receiver and transmitter  However  the radio signal  is weakened by various obstacles located in its path  apartment walls  furniture   etc   and in 
20. setting  4 000  each 66 minutes     Defines a time period  in seconds  by which a Flood Sensor will perform a    Wake  up    instruction   communicate with main controller  update parameters  update  software  Flood Sensor will wake up each defined time interval and will always  attempt to connect with the main controller  without retrying if connection fails   thus preventing a battery from discharging when the Sensor is used at the range  limit  in case of the main controller s breakdown  or in case the sensor is taken  away from the main controllers range   This parameter is relevant in case of  battery operation   higher Wake up interval means the Sensor communicates less  often saving a battery     After successful communication attempt  a sensor will go into standby mode   update parameters or will enter a software update mode    After failed communication attempt  a sensor will go into standby mode until  another time interval will have elapsed     1  Alarm cancellation delay    Delays flood alarm cancelation for the device after flooding has ceased   Available settings  0   3 600  in seconds  each 1s    Default setting  0  no delay  immediate alarm cancelation    Parameter size   2 bytes     Determines time period  in seconds  by which a Flood Sensor will retain the flood  state after the flooding itself  has ceased  Sensor will keep on reporting flooding to  the main controller  This parameter settings do not affect acoustic and visual  alarms  which turn off immedia
21. sor tries to establish routed  connection with the main controller  through intermediary devices     LED Indicator glowing yellow   Fibaro Flood Sensor communicates with the  main controller through other  intermediary devices  After two seconds the Sensor  will retry to directly connect to the main controller  which will be signaled with the  Indicator pulsing green     LED Indicator pulsing violet   Fibaro Flood Sensor communicates at the range  limit  If connection proves successful it will be confirmed with a yellow glow  It   s not  recommended to use the sensor at the range limit     LED Indicator glowing red   Fibaro Flood Sensor unable to connect to the main  controller directly or through another Z Wave network nodes     XII  SENSOR OPERATION WARNING    By default  flood sensor s insensitivity is set to 1 second  which means flooding will  be reported one second after it   s been detected     Tilt tamper is insensitive to little vibrations and turns  After its activation   insensitivity is turned off for 15 seconds  After that  each Sensor   s movement will  trigger audible alarm  consisting of 3  brief acoustic signals     XIII  BATTERY USE WARNING    Fibaro Flood Sensor is a battery powered device  Using batteries other than  specified may result in explosion  Dispose of properly  observing environmental  protection rules     XIV  ADVANCED CONFIGURATION    Wake up interval  battery mode     Available settings  0 or 5   86399  in seconds  5 s  to 24 hours   Default 
22. tant powering mode a sensor may operate without a battery  Installing a  battery is recommended though  as it will serve as an emergency power source   When constant power fails  sensor will automatically shift to an emergency mode   All reports  including flood and temperature  will be sent immediately  but it will not  be possible to modify the configuration or association settings until constant power  returns  If a sensor served as a signal repeater for other Z Wave devices  in  emergency mode signal repeating function will be deactivated        NOTE   Fibaro Flood Sensor will automatically exit emergency mode once  12 24 VDC at  12 and GND terminals is detected  according to  diagram no 2  and the device wakes up after detecting an event   i e  flood alarm  temperature report  tilt  or manual wake up using  TMP button        BATTERY TIPS    Fibaro Flood Sensor   s battery life is ca  2 years at factory default  settings  The current battery level is displayed in a Home Center 2  interface  Red battery icon means a battery needs replacement  In  order to avoid triggering tamper alarm while replacing the battery   Il nd association group   s associations must be deleted  and  1 Sensor s parameters    configuration set to default   Alternatively  the Sensor may be powered by VDC power source   12   24 VDC in accordance with a wiring diagram no 2    in such  a configuration  a battery will serve as an emergency power  supply        NOTE   Mounting screws shown in a diagram n
23. tely after flooding ceases     2  Acoustic and visual signals On   Off in case of flooding  The parameter allows for LED indicator and acoustic alarm deactivation in case of  flooding detection     Available settings    0   acoustic and visual alarms inactive   1   acoustic alarm inactive  visual alarm active  2   acoustic alarm active  visual alarm inactive  3   acoustic and visual alarms active   Default setting  3   Parameter size  1  byte     Changes in this parameter settings allow for increasing a battery life  Settings  changes will not affect the Sensors communication with the main controller    commands to association groups  alarms and reports will still be sent     5  Type of alarm frame sent to 1 st association group  FLOOD     Available settings    0   ALARM WATER command frame  255   BASIC SET command frame  Default setting  255   Parameter size  1  byte     The parameter determines a type of command frame sent by the Sensor in case  flooding has been detected or cancelled     7  Forced dimming level   roller blind opening level  when sending turn on    open command to 1 st association group devices   In case of alarm frames  alarm priority is determined    Available settings   1 99  or 255   Default setting  255   Parameter size  1  byte     The value of 255 allows for turning a device on  In case of a Dimmer it means  turning it on with the last memorized state  e g  Dimmer set to 30  and turned off   turned on again using 255 command is turned on with last st
24. vice and reconfigure the Z Wave network by triple  clicking the TMP button        NOTE   The TMP button has two functions    1  Including   Excluding the device into   from the Z Wave network    1 2  Tamper contact for Il nd Association Group  When a sensor is  included into the Z Wave network  case opening alarm may be  activated  according to parameter 74 settings         V  POWERING MODE INFORMATION    There are two powering modes for the Fibaro Flood Sensor  By default it s powered  by a factory included battery  In addition it can work with a constant current  after  connecting a 12   24 VDC power supply to  12 and GND terminals  see diagram  no 2   Powering mode configuration is carried out automatically  while a sensor is  being included into the Z Wave network  When battery powered  a Fibaro Flood  Sensor communicates with a Z Wave network main controller periodically   Detected alarms are sent immediately  but configuration parameters and  associations settings only at specified wake up intervals  or at a manual wake up   TMP triple click   In DC powering mode  configuration and associations  parameters are sent when necessary  and in addition a sensor serves as a Z Wave  signal repeater     Switching to a constant current powering mode    1  Exclude a sensor from the Z Wave network    2  Connect constant current power source  12   24 VDC  to  12 and GND  terminals observing wiring diagram no 2    3  Include the Fibaro Flood Sensor into the Z Wave network     In cons
25. which shall be free of any defects and its condition  shall not be worse than the original device owned by the Customer     4  In special cases  when the device cannot be replaced with the device of the same type   e g  the device is no longer available in the commercial offer   the Manufacturer may  replace it with a different device having technical parameters similar to the faulty one   Such activity shall be considered as fulfilling the obligations of the Manufacturer  The  Manufacturer shall not refund money paid for the device     5  The holder of a valid guarantee shall submit a guarantee claim through the guarantee  service  Remember  before you submit a guarantee claim  contact our technical support  using telephone or e mail  More than 50  of operational problems is resolved remotely   saving time and money spent to initiating guarantee procedure  If remote support is  insufficient  the Customer shall fill the guarantee claim form  using our website    www fibargroup com  in order to obtain claim authorization  When the guarantee claim  form is submitted correctly  the Customer shall receive the claim confirmation with an  unique number  Return Merchandise Authorization  RMA      6  The claim may be also submitted by telephone  In this case  the call is recorded and  the Customer shall be informed about it by a consultant before submitting the claim   Immediately after submitting the claim  the consultant shall provide the Customer with  the claim number  RMA number
    