        Fibaro FGK-101
         Contents
1.          NOTE    To ensure the most accurate position detecting  always install the magnet in relation to the Sensor s  body  as shown in diagram 4        NOTE    Fibaro Door Window Sensor has two TMP buttons    inside and underside the casing    During normal operation both TMP buttons must be  secure  Do not use the sensor with opened casing           NOTE    TMP button  located on the underside of the  device  has two functions    1  sets a device into the learn mode  Include to    Exclude from a Z Wave network     2  tamper button  After correct installation  fig  5  and 6   removing the whole sensor from its location  or opening its casing may release the TMP button  and trigger an alarm  If the TMP is to serve as a  tamper button  association for Il nd association  group must be configured  optionally  use the  Parameter 13      FE  ie le          USING IN INPUT     The Fibaro Door Window Sensor has a one   potential free IN input  IN input status may be  modified through the Sensor itself or by sending  GND signal to IN  diagram 3   If the Door Window  Sensor will be used only as a binary sensor  do not  install the magnet      l    TMP   BOTTOM VIEW    Diagram 1   General   TOP VIEW   DS18B20  TP  VDQ  max 30m  TD  DQ  __ ee    DS18B20    123   VIEW FROM BELOW     GND  TD  DQ   TP  VDQ     Diagram 2   Connection to DS18B20 sensor          Diagram 6   Incorrect sensor installation    NOTE    Every time any changes are made to the  configuration of TP and TD lines  1 wi
2.    FIBARO    C    OPERATING MANUAL  DOOR   WINDOW SENSOR  FGK   101   107 v2 1   v2 3    The Fibaro Door   Window Sensor is a wireless  battery powered   Z Wave compatible reed sensor  Each time its two parts  i e  the  sensor s body and a magnet separate  a radio signal is sent  In  addition the Fibaro Door   Window Sensor supports one DS18B20  temperature sensor and has one potential free input    The Fibaro Door   Window Sensor is designed for use with scenes in  home automation systems  alarm and surveillance systems and  everywhere else where information related to opening   closing of  doors  windows  garage gates  etc  is needed     Technical data     Power supply single ER14250  1 2AA  3 6V    battery    Inputs single  potential free    Supported temperature single  DS18B20    sensors  Operating temperature 0 40  C  Radio protocol Z Wave    Radio frequency 868 4 MHz EU   908 4 MHz US   921 4 MHz AU NZ   869 2 MHz RU   Range up to 30m indoors  depending on    building materials used and the  building structure    Dimensions  L x W x H  76x 17x 19mm    Technical information     e Controlled via  Fibaro System components or any other Z Wave  compatible controller    e Door window opening detected through Sensor s body and a  magnet separation    e Quick installation   easily mounted on doors  windows  garage  gates  roller blinds  using double sided adhesive tape or screws    e Compatible with DS18B20 temperature sensors    e When connecting DS18B20 use single wire lead 
3.   The guarantee for all parts replaced in the guarantee  process shall be equal to the guarantee period of the original  device  The guarantee period of the replaced part shall not be  extended     11  Costs of delivering the faulty device shall be borne by the  Customer  For unjustified service calls  the Service may charge the  Customer with travel expenses and handling costs related to the  case     12  AGS shall not accept a complaint claim only when    e the Device was misused or the manual was not observed    e the Device was provided by the Customer incomplete  without  accessories or nameplate    e it was determined that the fault was caused by other reasons than  a material or manufacturing defect of the Device   e the guarantee document is not valid there is no proof of purchase     13  The Manufacturer shall not be liable for damages to property  caused by defective device  The Manufacturer shall not be liable for  indirect  incidental  special  consequential or punitive damages  or  for any damages  including  inter alia  loss of profits  savings  data   loss of benefits  claims by third parties and any property damage or  personal injuries arising from or related to the use of the Device     14  The guarantee shall not cover    e mechanical damages  cracks  fractures  cuts  abrasions  physical  deformations caused by impact  falling or dropping the device or  other object  improper use or not observing the operating manual    e damages resulting from external cau
4.  allows for direct transmission of control  commands between devices and takes place without  the participation of the main controller  Owing to this  mechanism the Door Window Sensor may  communicate with devices even if the main controller  is completely destroyed  e g  in the event of a fire     The Fibaro Door Window Sensor supports three association  groups     Group   is assigned to input IN1  and the magnetic sensor    Sending BASIC SET or ALARM command frames     Group Il is assigned to TMP button  Once the button is released   ALARM GENERIC frame is sent to associated devices     Group Ill reports on the condition of the device  only one device  may be assigned to the group  main controller  by default      The Fibaro Door Window Sensor allows for control over 5 regular  devices and 5 multichannel devices per group  out of which 1 field  is reserved for the network controller     In order to add an association  with the use of the Home Center 2    controller  go to device options by clicking this icon  a    Select the device options tab  Next specify which devices will be  associated  and to which association groups  Sending of  configuration commands to associated devices might take up to a  few hours  depending on previous devices settings and the number  of devices within the network        NOTE    Any new association order given while any  association commands are already being sent to  devices  cancels previous one        V Configuration    The Door   Window Sen
5.  are always sent        Parameter no  12   Sensitivity to temperature changes  The maximum acceptable  difference between the last reported temperature and the current  temperature read from the sensor  If the temperatures differ by the  set value or more  a report with the current temperature value is  sent to the device assigned to association group no  3     Default value  8  0 50C     Available parameter settings  0     255  OoC to 160C   3820F      60 80F     To set an appropriate parameter value use the following formula    x   delta T x 16   for Celsius   x   delta T x 80   9   for Fahrenheit   x   parameter value   delta T      maximum acceptable temperature gradient in Celsius or  Fahrenheit    If the value is set to 0       if the wake up interval is set to 255 seconds  temperature report  will be sent according to the interval       if the wake up interval is set to over 255  temperature report will be  sent each ca  4 minutes     Parameter value  1  byte         Parameter no  13   Sending an alarm or control frame  for IN input  depending on  parameter no 5 value   and TMP button alarm frame  The frame is  sent in    broadcast    mode  i e  to all devices within range    information sent in this mode is not repeated by the mesh network     Default value  0    Available parameter settings    0     IN and TMP Broadcast mode inactive    1    IN broadcast mode active  TMP broadcast mode inactive  2     IN broadcast mode inactive  TMP broadcast mode active  3     IN an
6.  linked bus system   Fibaro operates in the free band for data transmission  The  frequency depends on the radio regulations in each individual  country     Each Fibaro network has its own unique network identification  number  home ID   which is why two or more independent systems  may be installed in a single building without any interference     Although the Z Wave technology is fairly new  it has already been  accepted as an official standard  just like Wi Fi  Numerous  manufacturers from various fields offer solutions based on Z Wave  technology  compatible with one another  This makes the system fit  for the future and allows for further development  For more  information go to www fibaro com     Fibaro establishes a dynamic network structure  From the moment  of start up  the location data of respective devices of the Fibaro  System is updated automatically  in real time  by confirming their  condition in the working mesh network     Il Sensor Installation     1 Connect Fibaro Door Window Sensor according to the  appropriate diagram  if necessary    2  Place battery inside the Sensor s casing    3  Include into the Z Wave network    4  Install Fibaro Door Window Sensor observing diagram 4           EXPLANATION OF CONDUCTOR MARKINGS     TMP   Tamper button  Detects removal  tampering etc  Used also  as a service button  to include exclude the device to from the  Z Wave network    IN   Potential free input    TP      TEMP_POWER    Power out for DS18B20 temperature  senso
7.  no longer than 30  meters    e May be connected to a switch via potential free IN input        HINT   Connections should be made specifically  according to the diagrams presented in this  manual  Incorrect connections may be hazardous  or lead to device damage          General Information on the Fibaro System     Fibaro is a system that does not require any additional conductors   it is based on the Z Wave technology  Fibaro offers a wide array of  advantages in comparison to other  similar systems  In general   radio based systems establish a direct connection between the  receiver and the transmitter  The radio signal is attenuated by every  obstacle along its path  in the household e g  walls  furniture  etc    In the worst case the radio system ceases to function  The  advantage of the Fibaro System is the fact that the devices act not  only as a signal receiver and transmitter  but also as a signal  repeater  If a direct radio link between the transmitter and the  receiver cannot be established  the connection will be carried out  with the use of other devices participating in communication     Fibaro is a bidirectional wireless system  This means the signal is  not only sent to the receivers  but also the receivers send feedback  confirming the reception of the signal  This also confirms the  condition of receivers  which allows us to check whether or not a  device has actually been switched on  The safety of transmission of  the Fibaro System is comparable with a wire
8. LARM CO2 frame   4     ALARM HEAT frame   5     ALARM WATER frame   255     Control frame BASIC_SET    Parameter value  1  byte         Parameter no  7   Value of the parameter specifying the forced level of dimming ope   ning roller blinds when    switch on     open    commands are sent to  devices from association group no 1     In case of alarm frames an alarm priority is specified     Default value  255  Possible parameter settings   1     99  and 255    Value of 255 makes it possible to activate a device  In case of the  Dimmer module it means activating the device and setting it to the  previously stored condition  e g  when Dimmer is set to 30    deactivated and then reactivated using 255 commend  it will be  automatically set to the previous condition i e  30      Parameter value  1  byte         Parameter no  9   Deactivating transmission of the alarm cancelling frame or the  control frame deactivating the device  Basic   It allows for disabling  the function of deactivating the device and cancelling alarms for  devices associated with IN input     Default value  0  Available parameter settings   0     for association group no  1 information is sent    1     for association group no  1 information is not sent     Parameter value  1  byte         NOTE   Scene activation functionality may shorten the  battery life  even by 25            NOTE    The parameter cancels alarms only  Information on  alarm violation or activation commands for devices  from association groups
9. d TMP broadcast mode active    Parameter value  1  byte         NOTE    If the    broadcast    mode of information transmission  is activated for a given channel  then transmission of  information in    singlecast    mode  i e  to devices  assigned to the association group  for this channel is  deactivated        Parameter no  14  Scene activation functionality   Default value  0    Available parameter settings   0   functionality deactivated  1   functionality activated    The device offers the possibility of sending commands compatible  with Command class scene activation  Information is sent to  devices assigned to association group no  3    Controllers such as the Home Center 2 are able to interpret such  commands and based on these commands activate scenes  to  which specific scene IDs have been assigned  The user may  expand the functionality of a button connected to IN input by  distinguishing the sequence of it being pushed  For example   double click would trigger the    goodnight    scene and triple click  would trigger the    morning    scene  To fully use the possibilities  offered by the parameter no 14 it is recommended to use a  momentary or a toggle switch  parameter no 3      Scene ID is determined in the following manner    IN input    Switch from    off    to    on    ID10   Switch from    on    to    off    ID11   Remaining IDs are recognized correctly if the value of parameter  no 3 was set to 2   Holding down ID12   Releasing ID13   Double click ID14   T
10. ded by FIBAR GROUP Sp  z o o    hereinafter  Manufacturer    based in Poznan  ul  Lotnicza 1   60 421 Poznan  entered in the register of the National Court  Register kept by the District Court in Pozna    VIII Economic  Department of the National Court Register  no  370151  NIP  7811858097  REGON  301595664     2  The Manufacturer is responsible for equipment malfunction  resulting from physical defects  manufacturing or material  of the  Device for 12 months from the date of its purchasing     3  During the Guarantee period  the Manufacturer shall remove any  defects  free of charge  by repairing or replacing  at the sole  discretion of the Manufacturer  any defective components of the  Device with new or regenerated components  that are free of  defects  When the repair impossible  the Manufacturer reserves the  right to replace the device with a new or regenerated one  which  shall be free of any defects and its condition shall not be worse than  the original device owned by the Customer     4  In special cases  when the device cannot be replaced with the  device of the same type  e g  the device is no longer available in the  commercial offer   the Manufacturer may replace it with a different  device having technical parameters similar to the faulty one  Such  activity shall be considered as fulfilling the obligations of the  Manufacturer  The Manufacturer shall not refund money paid for the  device     5  The holder of a valid guarantee shall submit a guarantee claim  th
11. e repairs shall not include periodic  maintenance and inspections  in particular cleaning  adjustments   operational checks  correction of errors or parameter programming  and other activities that should be performed by the user  Buyer    The guarantee shall not cover natural wear and tear of the Device  and its components listed in the operating manual and in technical  documentation as such elements have a defined operational life     16  If a defect is not covered by the guarantee  the Manufacturer  reserves the right to remove such defect at its sole discretion   repairing the damaged or destroyed parts or providing components  necessary for repair or replacement     17  This guarantee shall not exclude  limit or suspend the Customer  rights when the provided product is inconsistent with the purchase  agreement        This Device may be used with all devices  certified with Z Wave certificate and should be  compatible with such devices produced by  other manufacturers    Any device compatible with Z Wave may be added  to Fibaro system        FIBARGROUP  FIBARO    In case of any technical questions contact customer service centre  in your country     www  fibargroup com    
12. other devices included in the Fibaro  System     e Multi Channel Association   controlling other multi channel  devices included in the Fibaro System    Ill Fibaro Sensor Start up    1 Installation of the Door Window Sensor    STEP 1  Install the device observing the Figure 4 for correct positioning of  the Sensor and the magnet  Close the Sensor s casing      Inclusion Exclusion  of the Fibaro Door Window Sensor  to from   the Z Wave network     STEP 2   The Fibaro module must be in range of the Home Center 2  controller  because the procedure of inclusion to the Fibaro System  requires direct communication with the controller     STEP 3  Locate TMP button  which allows for proper inclusion of device     2  Resetting the Fibaro Door Window Sensor   There is one way to reset the Fibaro Door Window Sensor  The  procedure cleans its EPROM memory  including the main controller  and Z Wave network data     To reset the Fibaro Door Window Sensor please follow below  instructions     1  Take off the Sensor s cover and remove battery  Make sure the  TMP button is intact     2  Touch the Sensor s body with a magnet    3  Insert the battery    4  Remove the magnet from the Sensor s body   5  Remove the battery   6  Re install the battery     7  Reset will be confirmed by double LED blink        NOTE    Resetting the device memory doesn t remove it  from the Z Wave network s main controller  memory  To be able to re include the device into the  Z Wave network please exclude it first  E
13. r    TD      TEMP_DATA    Signal terminal for DS18B20 temperature  sensor    GND      GROUND    Ground terminal     TMP        TOP VIEW  Tee     TD  DQ     GND    MAGNETIC  SENSOR             max  5mm     7 5  Cs   NS S    Diagram 4   Correct positioning of the Sensor  and the magnet          STEP 4  Set the Home Center 2 controller to the inclusion or exclusion mode   see  Home Center 2 controller instructions      STEP 5   The Fibaro Door Window Sensor is added to the network by quickly  pressing the TMP button three times  the button is located on the  underside of the device  inside its casing      STEP 6   Correct inclusion of the device to the network will be signalled by  the Home Center 2  see  Home Center 2 controller operation  instructions            FIBARO   t       No    Diagram 5   Correct sensor installation    BATTERY USE    The Fibaro Door Window Sensor s battery life is up  to 2 years  on default settings    Current battery level is displayed in the Home  Center 2 configuration interface  If a battery icon  turns red  it means the battery needs replacement   In order not to trigger an alarm when replacing the  battery  Il nd association group must be deleted  and the Sensor s configuration must be changed to  default  prior to the battery change        NOTE    Door Window Sensor is equipped with a built in  LED  LED blinks each time Door Window Sensor  changes its state  LED blinking slowly   correct  inclusion  LED blinking rapidly   inclusion error        
14. re   i e  when  DS18B20 sensor is connected disconnected  it is  necessary to execute the procedure of exclusion  and repeated inclusion of the sensor module to the  Z Wave network  The system will enter into the  learning mode only after connected DS18B20  sensor has been detected  about 10 s         NOTE   Do not connect sensors other than DS18B20 to the  1 wire line  TP and TD terminals      NOTE   It is prohibited to connect the TP and TD lines to  devices not compatible with the 1 wire protocol     Sieh E fe  si                USING DS18B20 TEMPERATURE SENSOR     The DS18B20 temperature sensor may be installed  anywhere where very precise temperature readouts  are necessary  If adequately protected  the  DS18B20 sensor may be installed in humid  conditions  under water  sealed in concrete or placed  under the floor              ANTENNA ARRANGEMENT INSTRUCTIONS     The antenna should be placed above the battery   Never cut  shorten or bend the antenna  Its length is  suited ideally to the band at which the system  functions     Metal surfaces in close vicinity  e g  metal switch  boxes  metal door trims  may impair the reception  capability                 TOP VIEW        BELL PUSH    Diagram 3   Example connection   momentary switch    GLOSSARY OF TERMS     e INCLUSION   the device sends out a Node Info frame  which  makes it possible to add it to the Fibaro System  Home Center 2      e EXCLUSION   remove the device from the Fibaro System     e ASSOCIATION   controlling 
15. riple click ID15    Parameter value  1  byte      VI Additional Functionality    Alarm Frame Support     The Fibaro System allows you to set the device   s reaction to alarms   reaction to SENSOR_ALARM_REPORT frame   The Fibaro  Door Window Sensor sends alarm frames of different types   depending on parameter s no  5 settings  The user should declare  type of alarm frame for each connected sensor  For example  for a  smoke detector connected to IN input the user should declare the  type 1 ALARM SMOKE frame  value of 1 should be entered   to  ensure the remaining Z Wave network devices recognize the  information on smoke detector alarm correctly     Vil Door   Window Sensor operation    The Fibaro Door Window Sensor may be operated using     e Any System compatible controller  e g  Home Center 2    e Cellular phone  e g  iPhone or phones from other manufacturers   with the proper control application       PC  with the use of an Internet browser    e Tablets  e g  iPad    e Using the TMP button  located inside the housing     VIII Procedure to be followed in case of interference    The Device does not react to a programmed transmitter    e Make sure the maximum range has not been exceeded and there  are no obstacles along the signal path containing metal surfaces   e g  metal cabinets  Ferro concrete ceiling  load bearing walls  etc    e Make sure the device is not in the learning mode    e Alternately repeat the programming process     IX Guarantee    1  The Guarantee is provi
16. rough the guarantee service  Remember  before you submit a  guarantee claim  contact our technical support using telephone or  e mail  More than 50  of operational problems is resolved  remotely  saving time and money spent to initiating guarantee  procedure  If remote support is insufficient  the Customer shall fill  the guarantee claim form  using our website   www fibargroup com   in order to obtain claim authorization    When the guarantee claim form is submitted correctly  the  Customer shall receive the claim confirmation with an unique  number  Return Merchandise Authorization  RMA      6  The claim may be also submitted by telephone  In this case  the  call is recorded and the Customer shall be informed about it by a  consultant before submitting the claim  Immediately after submitting  the claim  the consultant shall provide the Customer with the claim  number  RMA number      7  When the guarantee claim form is submitted correctly  a  representative of the Authorised Guarantee Service  hereinafter as   AGS   shall contact the Customer     8  Defects revealed within the guarantee period shall be removed  not later than 30 days from the date of delivering the Device to AGS   The guarantee period shall be extended by the time in which the  Device was kept by AGS     9  The faulty device shall be provided by the Customer with    complete standard equipment and documents proving its purchase     10  Parts replaced under the guarantee are the property of the  Manufacturer
17. ses  e g   flood  storm  fire   lightning  natural disasters  earthquakes  war  civil disturbance   force majeure  unforeseen accidents  theft  water damage  liquid  leakage  battery spill  weather conditions  sunlight  sand  moisture   high or low temperature  air pollution    e damages caused by malfunctioning software  attack of a  computer virus  or by failure to update the software as recommen   ded by the Manufacturer    e damages resulting from  surges in the power and or telecommuni   cation network  improper connection to the grid in a manner  inconsistent with the operating manual  or from connecting other  devices not recommended by the Manufacturer    e damages caused by operating or storing the device in extremely  adverse conditions  i e  high humidity  dust  too low  freezing  or too  high ambient temperature  Detailed permissible conditions for  operating the Device are defined in the operating manual    e damages caused by using accessories not recommended by the  Manufacturer   e damages caused by faulty electrical installation of the Customer   including the use of incorrect fuses    e damages caused by Customer s failure to provide maintenance  and servicing activities defined in the operating manual    e damages resulting from the use of spurious spare parts or  accessories improper for given model  repairing and introducing  alterations by unauthorized persons    e defects caused by operating faulty Device or accessories     15  The scope of the guarante
18. sor offers a wide range of advanced  settings  The parameters listed below are available in the  Fibaro configuration interface     In order to configure the Fibaro Door   Window Sensor  using the  Home Center 2 controller  go to the device options by clicking on    the icon  a    Next  select the device options tab     Device parameters     Parameter no  1   Input IN alarm cancellation delay    Additional delay after an alarm from input IN has ceased  The  parameter allows user to specify additional time  after which the  input IN alarm is cancelled once its violation has ceased     Default value  0  Available parameter settings  0     65535 s    Parameter value  2  byte        Parameter no  2  Status change signalled by LED     Default setting  1   Available parameter settings   0   LED turned Off    1   LED turned On     Parameter value  1  byte         Parameter no  3  Type of IN input   Default value  0     INPUT_NC  Normal Close     Available parameter settings    0     INPUT_NC  Normal Close   1     INPUT_NO  Normal Open   2     INPUT_MONOSTABLE   3    INPUT_BISTABLE    Parameter value  1  byte         Parameter no  5   Type of control frame transmitted for association group 1  activated  via IN input  The parameter allows you to specify the type of an  alarm frame or to force control frames transmission  BASIC_SET     Default value  255     BASIC SET    Available parameter settings    0     ALARM GENERIC frame   1     ALARM SMOKE frame   2     ALARM CO frame   3     A
19. xclusion  may be performed either before or after the reset  procedure        3  Controlling the Fibaro Door Window Sensor with  the Home Center 2 Controller    The Door Window Sensor is a multichannel device  This means  that it is equipped with an independent input circuit and a 1 wire bus  allowing it to be connected to aDS18B20 temperature sensor  As a  result  each device is represented by an independent icon in the  System     X    Sa   Arm    Disarm       Fig  1   Door   Window Sensor icon  in the Home Center controller    Temperature    T 21 25  C           Fig  2   DS18B20 temperature sensor icon  in the Home Center controller    Sensor used without a DS18B20 sensor  or used with a switch  connected to IN input  will be represented by single icon  After the  DS18B20 temperature sensor has been connected  temperature  sensor icon will be displayed        NOTE    If a temperature sensor icon is not displayed  despite the fact the sensor itself has been  connected  or if the temperature readings are  incorrect  inspect the connections on the 1 wire  bus  in particular the connection between sensor  outputs and the line  and the total length of the bus  wire which should not exceed 30m        IV Association    Association allows the Fibaro Door Window Sensor to directly  control another device in the Z wave network  e g  Dimmer  Switch   On Off   Roller Shutter or trigger scenes  scene control is only  possible via the Home Center 2 controller         NOTE    Association
    