1. EC24U3032 Page 15 Black Box Tech Support FREE Live 24 7 Tech support the way it should be a Great tech support is just 60 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box Network Services is your source for an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 60 seconds or less Copyright 2014 All rights reserved EWM12U242418 R3 rev 7 724 746 5500 blackbox com
2. Chapter 5 Optional Accessories Drawings 5 Optional Accessories Drawings Figures 5 1 through 5 5 illustrate some of the Elite Wallmount Cabinet s optional accessories Optional angle brackets attach to the back panel of the cabinet for mounting 19 rackmount equipment such as patch panels and PDUs Vertical stationary rails in rear section tapped 10 32 Optional EWM90DAB R2 90 angle bracket j ate eS LL Optional EWMABDAB R2 45 angle bracket kit centers Figure 5 1 Angle bracket and angle bracket kit Use the brush grommet kit to protect the interior of the cabinet from dust and debris Optional ECBGK3U brush grommet kit for 3U opening Figure 5 2 Optional ECBGK3U brush grommet kit for 3U opening EC24U3032 Page 13 Chapter 5 Optional Accessories Drawings Use the gland plate kit to close around cables to prevent unwanted airflow and keep dust and debris out Optional EC3UGP Gland Plate Kit Figure 5 3 Optional EC3UGP Gland Plate Kit Use the waterfall bracket to maintain bend radius when routing cables into the cabinet Optional ECW3U e waterfall bracket Figure 5 4 Optional ECW3U Waterfall Bracket EC24U3032 Page 14 724 746 5500 blackbox com Chapter 5 Optional Accessories Drawings Use the vent cover plate to keep dust and debris from entering the cabinet EWMDCP R2 Vent Cover Plate Figure 5 5 EWMDCP R2 Vent Cover Plate
3. 24 2151255 41 875 24 24 75 49 23 25 47 8 23 8 EWM26U482430 R3 26 49 24 30 2151255 41 875 so 30 75 49 29 25 47 8 23 8 Back wall to front door Base to top Side wall to side wall 1 2 General Construction Body 14 gauge steel Doors 16 gauge steel Rails 12 gauge steel Finish Black powder coat Grounding Ground studs located on rear section middle section and door PLEXIGLAS Thickness 0 2 0 5 cm Distance to Rear Section at Maximum Rail Depth 1 18 0 48 cm Distance to Front Door at Maximum Rail Depth 0 75 1 91 cm Rail Type 10 32 tapped Minimum Maximum Rail Depth 18 Deep Cabinet 0 to 7 56 0 to 19 2 cm 24 Deep Cabinet 0 to 13 56 0 to 34 4 cm 30 Deep Cabinet 0 to 19 56 0 to 49 7 cm Weight Capacity EWM12U242418 R3 150 Ib 68 2 kg EWM12U242424 R3 150 Ib 68 2 kg EWM12U242430 R3 150 Ib 68 2 kg EWM20U362418 R3 200 Ib 90 kg EWM20U362424 R3 200 Ib 90 c 9 EWM20U362430 R3 200 Ib 90 o EWM26U482418 R3 250 Ib 113 kg EWM26U482424 R3 250 Ib 113 kg EWM26U482430 R3 250 Ib 113 kg EC24U3032 724 746 5500 blackbox com Page 5 Chapter 1 Specifications One pair of adjustable mounting rails tapped 110 32 UNF 2B 17 749 opening 9 4 18 312 centers Height gt Mounting rails ___ _ 7 25 Depth see Table 1 1 Depth Figure 1 2 Right side
4. The 24 and 36 H cabinets include 4 4 10 x 2 lag bolts 4 flat washers and 4 locking washers The 48 cabinets include 6 4 10 x 2 lag bolts 6 flat washers and 6 locking washers e 1 pair of 10 32 mounting rails This user manual 2 4 Optional Accessories e 3 RU Conduit Adapter Plate ECP3U e Extra pair of rails for 24 H wallmount EWM12URK R2 e 3 RU Brush Grommet Kit ECBGK3U e Extra pair of rails for 36 H wallmount EWM20URK R2 e 45 Degree Angle Bracket EWM45DAB R2 Extra pair of rails for 48 H wallmount EWM26URK R2 e 90 Degree Angle Bracket EWM90DAB R2 e 1 RU x 6 D standoff bracket for rear section EWMT1UGSB R2 e 3 RU Waterfall Radius Bracket ECW3U e Fan RMT373 R3 e 3 RU Gland Plate Kit EC3UGP e Fan RMT373AE R3 e 3 RU Filler Panel RMTBO3 e Vent Cover Plate EWMDCP R2 EC24U3032 Page 8 724 746 5500 blackbox com Chapter 3 Mounting Instructions 3 Mounting Instructions 3 1 Receiving Unpacking and Removing the Elite Wallmount Enclosure from the Pallet Inspect for damage and report damage if there is damage before receiving Refer to Section 2 3 for what s included in the package Unpack the enclosure by carefully removing the corrugated carton and corners Avoid damaging the enclosure when removing packaging WARNING Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attem
5. vingorinstaliig a DOOM ez conso tena olo ce tetti en n ARE E EA teda eds E aE Ae i a TE ecd 11 AD IREVEFSING iD OO isc e EAA E A E case EO 11 AA Adjusting the Raley it E E E E E A a Rane E et 12 5 Optional Accessories DiaWiMGS T M 13 EC24U3032 Page 3 Preface Safety Information Preface This manual is provided to prevent service personnel from committing an act that results in the risk of fire electric shock or injury to persons Only trained service personnel should receive unpack and assemble the Elite Wallmount Cabinet In addition only trained service personnel should install equipment in enclosures Safety Safety Symbols Used in this Manual This manual provides general safety guidelines to be observed during installation operation and maintenance of the Elite Wallmount Cabinet WARNING Failure to follow directions in the warning could result in injury to persons or loss of life CAUTION Failure to follow directions in the caution could result in damage to equipment or storage data Safety Considerations WARNING Improper handling and use of the Elite Wallmount Cabinet could result in equipment damage serious injury or possible death Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attempt to move enclosures by yourself Only UL Listed ITE units should be installed inside the Elite Wallmount C
6. lt gt BLACK BOX Customer Support Information EWM12U242418 R3 EWM12U242424 R3 EWM12U242430 R3 EWM20U362418 R3 EWM20U362424 R3 EWM20U362430 R3 EWM20U362430 R3 EWM26U482418 R3 EWM26U482424 R3 EWM26U482430 R3 EWM12UMFD R3 EWM20UMFD R3 EWM26UMFD R3 EWM12URK R3 EWM20URK R3 Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com e E mail info blackbox com EWM26URK R3 EWM45DAB R3 EWM90DAB R3 EWM1U6SB R3 Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks and Elite is a trademark of BB Technologies Inc PLEXIGLAS is a registered trademark of Roehm GmbH amp CO VELCRO is a registered trademark of Velcro Industries B V Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners We re here to help If you have any questions about your application or our products contact Black Box Tech Support at 724 746 5500 or go to blackbox com and dick on Talk to Black Box You ll be live with one of our technical experts in less than 60 seconds Page 2 724 746 5500 blackbox com eo Table of Contents dir
7. 4 sci M TE M 4 Safety Symbols Used in this Manual 5 2 ertet entm pe Eb da dde rad tdeo debut Haze acl Putat quads 4 Safety Considerations secte eto eec en sente c rede dee edite dd tec vite oe gaat eae atin endothe proce qs 4 1 SOC CU GAT INS e I ee 5 MD Sien LE TL 5 UUEECIISIE URTEIL MEE 5 2 GJ 8 px NM 8 22 cU cc 8 2 3 What s Included iua ettet a ec ora emrect ted cre dd ox nas tcv aa and Chev dev opu ed Pec eodd ch tege X Ne eee e ce Rr 8 24 Optional ACCESSORIES o oc tend ette taapia er ae said setae tod ene RE RESP TE RU eat Bane cudap aeta pud cedes us dde en Nd be teen 8 3 MOUNEIMGIMSERUGTIOMS sarng LTEM 9 3 1 Receiving Unpacking and Removing the Elite Wallmount Enclosure from the Pallet sss 9 3 2 MOning tO Wood Stud Walls eet renti daxticecanes aes cag eU EEE AA Paredes V enti eda uos duc o tror ees adeste ue erus 3 3 Loading Equipment 34 POWER onse imerimere 3 5 Protective Grounding 3 5 1 Connecting the Main Protective Grouding Stud to the Dedicated Branch Ground ssssssssse 10 3 5 2 Connecting the Main Protective Grounding Stud to the Protective Bonding Conductors ssssssssse 10 4 Op rati n M cms 11 4i Operating the Dooi er 11 4 2 Rem
8. abinet Be sure to read and follow all individual manufacturer equipment manuals for safety and installation instructions The Elite Wallmount Cabinet was not evaluated as a fire enclosure Proper spacing is required when installing electrical equipment to avoid electrical shock The ambient temperature operating range for the Elite Walllmount Cabinet and accessories is 50 to 495 F 10 to 35 C The non operating temperature is 4 to 140 F 20 to 460 C EC24U3032 Page 4 724 746 5500 blackbox com Chapter 1 Specifications 1 Specifications 1 1 Size Table 1 1 lists specifications for the cabinet shown in Figures 1 1 through 1 4 Table 1 1 Cabinet size specifications Exterior Door Door Exterior Depth Exterior Interior Interior Interior Part Number ofRUs Height Width Depth Width Height Depth w Hinges Height Depth Height Width EWM12U242418 R3 12 24 24 18 214254 17 875 18 18 75 24 17 25 2385 23 8 EWM12U242424 R3 12 24 24 24 2181253 17 875 24 24 75 24 23 25 238g 23 8 EWM12U242430 R3 12 24 24 30 21254 17 875 30 30 75 24 29 25 23185 23 8 EWM20U362418 R3 20 38 5 24 18 2151255 29 875 18 18 75 38 5 17 25 35 8 23 8 EWM20U362424 R3 20 38 5 24 24 214254 29 875 24 24 75 38 5 23 25 3585 23 8 EWM20U362430 R3 20 38 5 24 30 210254 29 875 307 30 75 38 5 29 25 35 8 23 8 EWM26U482418 R3 26 49 24 18 210254 41 875 18 18 75 49 17 25 47 8 23 8 EWM26U482424 R3 26 49 24
9. eyond 90 remove the top half of the upper hinge then grasp the door with both hands and carefully lift it upward When the door is free of two hinge pins pull the door away from the enclosure To attach the door align both door hinges to their respective hinge pins on the enclosure and slowly slide the door down until seated 4 3 Reversing a Door The front and rear doors are installed with two hinges as standard from Black Box Removing the hinges enables you to reverse the door by flipping them over and reinstalling the hinges using the universal mounting holes All the enclosure frames and doors can be hinged right or left hand The handle can be reversed along with the hinging See Figure 4 1 Reversible hinge Pivot female washer A Reversible x am f lo hinge male d ht li Z a Flat head qw Z Phillips screw A H0 32 OR Om A Flat head BZ Phillips screw 10 32 x 4 2 Figure 4 1 Reversing a door EC24U3032 Page 11 Chapter 4 Operation 4 4 Adjusting the Rails Mounting Rails One pair of 10 32 vertical mounting rails is installed in all Elite Wallmount Cabinets Additional mounting rails are available as accessories Figure 4 2 Adjusting the vertical mounting rails Rails are attached using a sliding nut and hex bolt Loosen both top and bottom bolts using an 11 mm socket set then adjust the rails front to back EC24U3032 Page 12 724 746 5500 blackbox com
10. ipment connected When not using a PDU each piece of equipment should be connected to a dedicated branch circuit 3 5 Protective Grounding A main protective earthing stud and grounding studs are provided WARNING To avoid injury to persons or loss of life ground each enclosure individually to the dedicated branch circuit earthing ground 3 5 1 Connecting Main Protective Grouding Stud to the Dedicated Branch Circuit Earthing Ground Conductor Connect the dedicated branch circuit ground conductor to the main protective earthing stud located inside at the bottom rear of the enclosure chassis using a listed ring or closed loop terminal 3 5 2 Connecting Main Protective Grounding Stud to the Protective Bonding Conductors Connect the rear door to the main protective grounding stud located inside at the bottom rear of the enclosure chassis using a listed ring or closed loop terminal Connect the front door to the grounding stud located inside at the bottom front of the enclosure chassis using a listed ring or closed loop terminal EC24U3032 Page 10 724 746 5500 blackbox com Chapter 4 Operation 4 Operation 4 1 Operating the Door The Elite Enclosure is supplied with two locks one for the front door and one to lock the middle section to the rear section The middle section and rear section incorporate a grabber catch that enables the middle section to be held shut without locking 4 2 Removing or Installing a Door Open the door b
11. pt to move enclosures by yourself WARNING Be careful when moving enclosures before installation Sudden stops and starts excessive force obstructed routes and uneven floor surfaces may cause the enclosure to topple over 3 2 Mounting to Wood Stud Walls Once a location for the cabinet has been selected inspect the wall and ensure that the wall or other mounting surface has a structural load capacity that will support the cabinet and the maximum payload Ensure that the mounting surface extends beyond the top bottom left and right edges of the rear of the cabinet The rear frame must be secured to a wall using the hardware provided For masonry or mounting to other surfaces the installer must provide the appropriate hardware WARNING Improper handling and use of the Elite Wallmount Enclosure could result in equipment damage serious injury or possible death Other Wall Surfaces For other wall types the installer must provide appropriate hardware EC24U3032 Page 9 Chapter 3 Mounting Instructions 3 3 Loading Equipment WARNING Only install equipment after the Elite Wallmount has been properly secured and mounted to the wall Maximum Load Capacity Rated or maximum load capacity for the Elite Wallmount See the Weight Capacity specification on page 5 3 4 Power When using power distribution units PDUs each PDU should be connected to a committed branch circuit that is rated for the continuous load of all the equ
12. view EC24U3032 Page 6 724 746 5500 blackbox com Chapter 1 Specifications la 16 00 35 Z a 3RU 2475 Figure 1 3 Top view Height see Table 1 1 Figure 1 4 Back view EC24U3032 Page 7 Chapter 2 Overview 2 Overview 2 1 Introduction Elite Wallmount Cabinets are designed to securely hold 19 rackmount equipment networking equipment phone equipment etc in tight spaces or closets 2 2 Features e Large openings in the back panel enable easy installation of pre wired equipment such as patch panels e Ships with one conduit panel on the top and one solid panel on the bottom e 3 RU Elite Cabinet accessories also fit the Elite Wallmount 3 RU openings top and bottom Welded steel frame e Includes one pair of 10 32 tapped rails Additional rails are available for four point mounting e Doors can be reversed to open left or right Doors available in mesh and PLEXIGLAS Double hinged for easy access to rear of equipment ocking rear section Accessories brackets provide additional mounting options in the rear section 2 3 What s Included Your package should include the following items If anything is missing or damaged please contact Black Box Technical Support at 724 746 5500 or info blackbox com Fully assembled Elite Wallmount Cabinet e 11 ground studs e 30 10 32 mounting screws 2 pairs of keys Mounting hardware for wood stud walls only