Home

Da-Lite 92580LVN projection screen

image

Contents

1. INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes Up lo 9 x 12 DA LITE Important Safety Instructions When using your video equipment basic safety precautions should always be followed including the following Read and understand all instructions before using 2 Position the cord so that it will not be tripped over pulled or contact hot surfaces 3 Ifan extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat d Jo reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric Shock when the appliance is used subsequently The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons Save These Instructions Pre Installation Carefully unpack screen and remove outer wrapping from case 2 Do not remove black tape or rubber bands from slat pocket 3 Always handle screen in horizontal position Installation There are three methods of mounting to include Flush against wall Suspended from ceiling use extension brackets and recessed above ceiling Concealed Allow Room For Access Use No 6 Brackets To Hang Behind Beam or Valance Ceiling Hanging Wall Mounted Y
2. Figure 6 any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Screen Adjustment For 220V 240V Screens with A Built In Low Voltage Control 1 Remove the cover plate from the 3 button wall switch and remove the switch from the junction box Locate small 3 position switch on back of wall switch See Figure 6 To adjust the down limit switch slide the 3 position switch to the down position Press and hold the down button to run the screen down to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON When the screen is in the desired down position slide the 3 position switch to the off center position The down limit Switch is now set To adjust the up limit switch slide the 3 position switch to the up position Press and hold the up button to run the screen up to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit Switch is now set To test limit switch setting make sure the 3 position switch is in the off center position Press and release the up or down button on the wall switch to operate the screen Replace switch and cover plate on the wall NOTE If stop button is pressed the wall switc
3. Common Ground Must Be Connected To Building Ground Power Input 120Vac 60Hz 120V Wiring Diagram with Optional Built In Low Voltage Control Up Limit Tactile Button Down Limit Tactile Button Front Of Wall Switch Wall Switch Power Wire 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible RJ 14 Pin Outs Tab Is Facing Up RJ 22 Pin Outs Tab Is Facing Up 12V Blue Bus RP Data Bus RP Data Yellow RO Data RO Data Green 5V 5V Red Ground Black White Ground RO Clock III Standard RJ 22 can be used in place of RJ 14 RJ 45 Pin Outs Tab Is Facing Up U eb Dry Contacts Common Manual 2 DO Brown Sa BUS dau C Blue Bus RP Data b Yellow RJ 45 Receptacle RQ Data Green 5V b Red Ground Black RJ 45 Jack RQ Clock L Orange Data Cable Manual 1 L Purple Green Ground Black Hot White Common Ground Must Be Connected To Building Ground Power Input 120VAC 60HZ Figure 5 Screen Adjustment For 120V Screens With A Buil
4. Reset circuit breaker Check above Tighten all loose wire connections Correct any improper connections DOT Position Check for power across black and white leads Up Position Check for power across red and white leads Let motor cool down for 15 minutes Try again Check for continuity Cut off old splice and reconnect Replace motor assembly NOTE Motor is a sealed assembly Replace motor assembly See instructions below See installation instructions See instructions below Adjust up limit switch Call factory for instructions Replace motor assembly Defective brake Replace motor assembly Roller displaced from mounting Pin end slipped out of nylon bearing bracket PP y g Realign pin end bracket Restoring Lost Roller Wrap Push strap over back of roller 2 Tape end of strap to pocket 3 Feed fabric as you pull strap to draw fabric over top 4 Remove tape and strap LIMITED ONE YEAR WARRANTY ON DA LITE PRESENTATION PRODUCTS Milestone AV Technologies LLC warrants certain Da Lite branded products to the original purchaser only to be free from defects in materials and workmanship for a period of one 1 year from the date of purchase by the original purchaser provided they are properly operated according to Da Lite s instructions and are not damaged due to improper handling or treatment after shipment from the factory This warranty does not apply to equipment showin
5. adjustment of screen Once desired position is reached turn switch over press and hold up tactile button until the LED on back of switch blinks green twice The up limit is now set To test limit switch setting press and release the up or down button on the wall switch to operate the screen 6 Replace switch and cover plate on the wall NOTE If the screen is in limit set mode and no buttons are pushed for 20 seconds the LED on the back of the wall switch will turn off the motor will return to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment IMPORTANT NOTE he wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible 240V Wiring Diagram with Optional Built In Low Voltage Control Blue Common Brown Hot 240VAC5OHz coo Ground Must be Green Connected to Building Ground Ground to Case ILT RJ 9 Pin Outs Tab Is Facing Up Connect Supplied RJ9 Cable to Splitter and Switch or use 4 Cable Conductor to Connect to Screw Terminals Optional IR and RF Remote Control Low Voltage Wall Switch UP DN GND 5V i i i 3 Position EO EO LL im Tal gt Front Back Dry Contacts IMPORTANT NOTE The wall switch is REQUIRED to make IR or Up Ground Common 5V Data or Down
6. 7 Warsaw IN 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE BRANDED PRODUCTS SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH THE DA LITE WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership A Milestone AV Technologies Brand 3100 North Detroit Street Warsaw Indiana 46582 P 574 267 8101 or 800 622 3737 F 574 267 7804 or 8773254832 E info da lite com www da lite com DL 0256 Rev 2 9 14 O 2013 Milestone AV Technologies LLC Printed in U S A 46832
7. Installation Motor End Diameter For Ceiling Installation Enclosure Cover Diameter Knock Out Fabric Height x Width As Ordered Up To 12 Feet x 12 Feet Figure 2 120V Wiring Diagram NOTE A single switch cannot be used to operate more than one screen Contact the factory for further information Wiring Enclosure Cover Do To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads ES ZE EE EEE ee giei White Limit 5 Switch GGe E Adjustment Rocker dde 3 Switch White BK Red Ls gg a e Down Black With Operating Switch In Multiple Control B ZO And Plate Furnished Installations This With Screen SPDT Switch Is Replaced By Se do Ac Common With Center Off The Low Voltage hea Bor Control Operated 120 V 60 Hz 2 5 Max Amp li Button B This Switch Cannot Be Used With LVC F Figure 3 Diameter Opening For Electrical Fittings Picture itr Surface 240 Volt Wiring Diagram For Standard Wall Switch Da Lite offers two styles of 240 volt wall switches for standard operation Please see wiring diagram included in wall switch box included with screen Screen Adjustment For Screens Without A Built In Low Voltage Control Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da Lite Should it be necessary to
8. Picture icture Picture Surface Surface Picture Surface Surface Figure 1 NOTE Under no circumstances should unit be completely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 4 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket Make sure screen is level Use a carpenter s level and plumb level A CAUTION Do not cut wrapping paper or tape with knife or any sharp tool Remove by hand ATTENTION Ne coupez pas le papier d emballage ou le ruban adh sif avec un couteau ou un outil tranchant Retirez la main 2 Remove tape and rubber bands from slat pocket 3 Install electrical hook up that applies to your unit Make sure to review your Electrical Installation Checklists and wiring diagrams included for either 120 volt switch 220 240 volt Switch or low voltage control 4 Test installation by running screen up and down a few times Be prepared to stop screen Standard Duty Cycle 1 MIN ON 3 MIN OFF NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C221 and the National Electric Code NEC NFPA 70 Cosmopolitan Electrol Installation Overall length A fabric width 8 Length B is the distance between wall mounting holes at back of end caps and is the fabric width 6 Y 34 Diameter Hole For Wall
9. adjust for more or less picture drop viewing area proceed in the following manner NOTE Use a screwdriver or 5 32 Allen wrench to make adjustments SETTING THE DOWN LIMIT POSITION To Reduce Screen Drop Turn the white limit switch screw Figure 3 clockwise to decrease the amount of screen drop Run the screen down to test the stop position If the screen drops too far raise the screen about one foot and adjust the limit switch again Repeat until the desired position is set To Increase Screen Drop urn the white limit switch screw counterclockwise to increase the amount of screen drop Run the screen down to test the stop position If the screen does not drop enough raise the screen about one foot and adjust the limit Switch again Repeat until the desired position is set Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller A CAUTION Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with O or 2 black at the top See the specification data sheet for details A ATTENTION N effectuez pas de r glage pour obtenir un d roulement sup rieur a celui command Au moins 1 a 1 2 tour de toile doit tre maintenu sur le cylindre Cet cran est dot de s rie d une bande noire sup rieure de O cm O po ou 5 cm 2 po Consultez la fiche technique pour plus de renseignements 120V Wir
10. g evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Sales Partners at PO Box 13
11. h will reverse direction To correct this press the stop button again This will reset the switch You will have to re set both the up and the down settings IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Troubleshooting Visit www da lite com to find installation and troubleshooting tutorials You will also find a link to Live Chat for interactive support and you can contact us by email at info da lite com or by phone at 800 622 3737 or 574 267 8101 with any troubleshooting questions Symptom Cause r Incorrect line voltage Screen will not operate Motor does not hum Blown fuse Tripped circuit breaker No power to operating switch or junction Power at junction box Thermal overload tripped Broken wire in the up or down position Defective motor limit switch or capacitor Motor hums Capacitor burned out dk Lost roller wrap Incorrect stopping position in downward direction DOT limit switch out of adjustment YA Lost roller wrap Incorrect stopping position in upward direction A Up limit switch out of adjustment Noise NOTE Screen will operate Gear noise with a low pitched hum Solution Verify 115125V or 220 240V If insufficient voltage rewire incoming electric line Replace fuse
12. ing Diagram with Optional Built In Video Projector Interface CAUTION The projector must be turned off before connecting the trigger wires to the projector Failure to do so may damage the controller ATTENTION Le projecteur doit tre teint avant de brancher les fils de d clenchement celui ci Tout manquement cette instruction pourrait endommager le contr leur Tactile Back Of Wall Switch Front Of Wall Switch Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable 72 Volt Screen Trigger On Projector IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible Figure 4 3 conductor 20 24 gauge wire can be used in place of the Supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board RJ 22 Jack RJ 22 Output Up a Dry Contacts Common Bus BUS 5V RJ 45 Receptacle RJ 45 Jack Data Cable VPI Trigger Module Black Hot White
13. t In Low Voltage Control or VPI Locate the wall switch and remove the cover plate from the 3 button wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are square silver with black round buttons See Figure 4 VPI or Figure 5 LVC for diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on back of switch turns solid red This will put the motor in limit set mode Turn the wall switch over and use the down button on front of switch Press and hold until the desired travel position is reached If you travel to far down you can press the up to move the screen upward If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen Once desired position is reached turn switch over press and hold down tactile button until the LED on back of Switch blinks red twice The down limit is now set 4 To adjust the up limit switch press and hold the up tactile button until the LED on back of switch turns solid green This will put the motor in limit set mode Turn the wall switch over and use the up button on front of switch Press and hold until the desired travel position is reached If you travel to far up you can press the down to move the screen downward If you press and let go of either up or down button the motor will do a small jog in that direction for finer

Download Pdf Manuals

image

Related Search

Related Contents

Das Magazin für Funk Elektronik · Computer  MC 2.0 WR  点検整備のすすめ  Kenwood DNX9980HD GPS Receiver User Manual  取扱説明軍  Wiley Beginning XSLT and XPath: Transforming XML Documents and Data  InfoPlus.21 Interface, User Manual (Software Details)    第19号様式エックス線装置設置届  VX-2100E Serie - Vertex Content Syndication System  