1. Install one 5 16 x 3 8 set screw C into threaded hole tightening firmly against column OPTIONAL Install one 5 16 x 1 4 security set screw D into threaded hole tightening firmly against column 4 Figure 4 Complete installation following mount installation instructions Installation Instructions CMA330 Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8800 002140 2012 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 11 12 USA International Europe Asia Pacific p TI U gt 0 6436 City West Parkway Eden Prairie 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 SCH n O S
2. DIMENSIONS 6 50 165 1 3 25 82 6 rf oH i uo 4 00 7 9 ACCEPTS 1 5 NPT THREADS 101 6 0 22 5 6 3 00 L 8 00 2 ua 203 2 2 63 66 9 T I m Weight Capacity 500 lbs 226 8 kg DIMENSIONS INCHES MILLIMETERS Security Included 5 32 B 1 5 32 security ANS Ta 5 16 18 x 3 8 Installation Instructions LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com lapis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou By Hand mano Von Hand Com a mao A mano Met de hand la main Optional Opcional Optional Opcional Opzionale Optie En option O d Hex Head Wrench Llave de cabeza hexagon
3. INSTALLATION INSTRUCTIONS 8 Off Set Ceiling Plate CHIEF CMA330 Our Mounts Your Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility t
4. al Sechskantschl ssel Chave de cabe a sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguranca Chiave di sicurezza Veiligheidssleutel Cl de s curit Socket Wrench Llave de cubo Steckschl ssel Chave de caixa Chiave a brugola Dopsleutel Cl douilles Installation Instructions CMA330 INSTALLATION AND INSTALLATION These CMA mounts are designed for attachment to a 2 x 6 wood framework ceiling a concrete ceiling or a suspended metal framing channel ceiling and provides vertical adjustments in 3 4 increments WARNING Do NOT attach to vertical mounting surfaces such as walls or angled ceilings WARNING IMPROPER INSTALLATION CAN LEAD LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installer s responsibility to make certain the structure to which the mount is being attached is capable of supporting five times the weight of the CMA mount and all attached equipment Reinforce the structure as required before installing the mount NOTE The following instructions assume a suitable mounting structure and surface exists prior to installation Installing to a Wood Framework Joists 1 Using ceiling plate A as a template mark locations of four pilot h
5. g Structure WARNING The CMA330 is designed to be mounted to a concrete ceiling with a minimum thickness of 8 and maximum drywall covering of 5 8 WARNING Fischer Ux10 anchors not provided must be installed into structurally sound solid concrete Installation into hollow concrete block mortar or concrete that exhibits cracking spalling or other defects may result in failure of anchor and serious personal injury or damage to equipment 1 Use four Ux10 anchors not provided to secure mount into solid concrete ceiling See Figure 3 for dimensions details 2 Place CMA mount over anchors aligning bolt holes in CMA mount with installed anchors 3 Secure CMA mount to ceiling using four 3 8 Grade 2 flat washers not provided and four 3 8 x 2 1 2 Grade 2 bolts not provided tightened over anchors Installing Extension Column WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to the CMA330 does not exceed 500 Ibs 227 kg 1 Route cables through extension column not included 2 Install 1 1 2 NPT following ANSI ASME B1 20 1 Schedule 40 0 154 minimum thickness aluminum ASTM B221 threaded extension column not included into CMA330 until tight with a minimum of four threads engaged 3 Secure extension column by one of the following methods See Figure 4
6. o make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to the CMA330 does not exceed 500 Ibs 226 8 kg WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair 2 WARNING Do not use this product outdoors IMPORTANT These CMA mounts are designed to be mounted to a 2 x 6 wood framework ceiling e mounted to a 8 concrete ceiling with a drywall covering of a maximum of 5 8 mounted to a suspended metal framing channel ceiling WARNING Do NOT attach to vertical mounting surfaces such as walls or angled ceilings SAVE THESE INSTRUCTIONS Installation Instructions CMA330
7. oles See Figure 1 Ensure the marks are in the center of wood joists NOTE Drywall not shown for clarity er x4 Figure 1 2 Drill 1 4 diameter pilot holes into wood joists See Figure 2 Ensure pilot holes are straight 3 Install and tighten four 3 8 x 2 1 2 minimum Grade 2 lag screws not included through CMA330 A into wood joist See Figure 2 See Figure 3 for dimensions details Figure 2 6 50 165 1 O G i 4 00 ACCEPTS 1 5 NPT THREADS 101 6 Figure 3 Installing to a Suspended Ceiling NOTE The CMA mount may be suspended from four 3 8 in diameter ASTM A307 or better threaded rods not provided which are secured to a 1 5 8 x 1 5 8 12ga metal framing strut channel spanning a maximum of 4 feet not provided by ASTM A307 or better 3 8 channel nuts not provided Threaded rods must have 16 threads per square inch 1 Insert the rods into the four bolt holes in the CMA mount 2 Secure the threaded rods to the CMA mount with ASTM A307 or better 3 8 jam nuts not provided and washers one of each on inside and one of each on outside not provided See Figure 3 for dimensions details Installation Instructions Installing to a Solid Concrete Ceilin