APC Smart-UPS On-Line
Contents
1. e lt 2 0 MeL2 N L2 L1 L e 18 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 Output hardwiring SRTSKRMXLW HW models SRT6K models Remove the 38 1 mm 1 5 in knockout panels Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 UPS Configuration Connect Emergency Power Off feature For instructions on how to connect the Emergency Power Off EPO switch refer to the Operation and Maintenance manual on the User Documentation CD supplied Configure controllable outlet groups The outlets on the UPS are grouped To configure the controlled outlet features use the Advanced menus on the display interface and navigate to Main Menu gt Configuration gt Outlets gt Outlet Group UPS Display Interface POWER ON OFF button Button illumination indications No illumination the UPS and the output power are off White illumination the UPS and the output power are on Red illumination the UPS is on and the output power is off Load icon Disable mute audible alarm icon UPS status information Operation mode icons ESCAPE button OK button su0870b UP DOWN buttons Controllable outlet group status icons Battery status icons
2. in E M ud O IC SRT6KXLI SRT6KRMXLI C l oO r3 1 oO oO E o Lr EO 0 5 Co Oo r3 A 3 GROUP 2 E ES N jl 9 O Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 13 14 SRT6KXLT SRT6KRMXLT su0883a su0884a 9 ERU o i HO 4 5 je 5 t o el iQ Clee o 6 4 _ _ E a o 2 9 js B 368 a Ld o o a 9 0 Smart U
3. 20 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 The icons on the LCD display interface screen may vary depending on the installed firmware version Load icon The approximate load capacity percentage is indicated by the number of load bar LOAD 0 0 sections illuminated Each bar represents 16 of the load capacity ef M Mute icon Indicates the audible alarm is disabled mute UPS Status Information The status information field provides key information on the status of the UPS The Standard menu will allow the user to select one of the following screens The Advanced menu will scroll through the following five screens Input Voltage Output Voltage Output Frequency Load Runtime In the case of a UPS event status updates will be displayed defining the event or condition that has occurred The display screen illuminates yellow to indicate a Warning and red to indicate an Alert depending on the severity of the event or condition Operation Mode Icons On Line mode The UPS is supplying conditioned mains power to connected equipment Bypass mode The UPS is in Bypass mode and the connected equipment will receive mains power as long as the input voltage and frequency are within the configured limits Green mode When in Green mode mains power is sent directly to the load In the event of a mains power outage there will be an interruption in power to the load of up to 8 ms while the UPS switches
4. PERSONNEL Adhere to all national and local electrical codes Wiring should be performed by a qualified electrician Strain reliefs are not provided with this unit Snap In strain reliefs are recommended The UPS must be wired into a branch circuit equipped with a circuit breaker rated as specified in the tables below Actual wire size must comply with required amp capacity and national and local electrical codes Recommended input terminal screw torque 16 Ibf in 2 Nm Failure to follow these instructions can result in equipment damage and minor or moderate injury SRTSK 6KXLT SRTSK 6KXLT IEC models Input connections Wire to L1 L2 Output connections Wire toL1 L2 System Wiring Voltage Current full External input Wire size load nominal circuit breaker typical typical SRTSKXLT SRTSKRMXLT SRTSKXLT IEC 208 240 24 30 2 1 Not applicable SRTSKRMXLT IEC P SRT6KXLT input 33A SRTGKRMXLT SRT6KXLT IEC oun 208 240 Vac 50 A 2 pole 6 AWG SRTGKRMXLT IEC P SRTSKXLUISRT6KXLI models Input connections Single phase Wire to L N Output connections Wire to L N 1 System Wiring Voltage Current full External input Wire size load nominal circuit breaker typical typical Input SRTSKXLI p 2 SRTSKRMXLI 220 230 240 24 40 A 2 pole 10 utput SRT6KXLI Input 3
5. to On Line mode When enabling Green mode consideration should be given to devices that may be sensitive to power fluctuations Battery mode The UPS is supplying battery power to connected equipment 4422 Controllable Outlet Group Icons Controllable Outlet Group Power Available The number next to the icon identifies the specific outlet groups that have available power Controllable Outlet Group Power Not Available The number next to the icon identifies specific outlet groups that do not have available power e e Battery Status Icons Battery Charge Status Indicates the battery charge status Battery Charge In Progress Indicates the battery is charging gt i Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U 21 Display interface operation Use the UP DOWN buttons to scroll through the options Press the OK button to accept the selected option Press the ESC button to return to the previous menu Menu overview The display interface has Standard and Advanced menu screens The preference for Standard or Advanced menu selections is made during initial installation and can be changed at any time through the Configuration menu The Standard menus include the most commonly used options The Advanced menus provide additional options Note Actual menu screens may differ by model and firmware version Refer to the UPS Operation Manual for menu configuration details LCD display interface
6. 2 SRT6KRMXLI Output 220 230 240 Vac 28 A 50 A 2 pole 16 mm 16 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 SRTSKRMXLW HW Input connections Single phase Wire to L L2 N D Output connections Wire to L1 L2 N System Wiring Voltage Current full External input Wire size load nominal circuit breaker typical typical Input 208 220 26 A 10 mm SRT5KRMXLW HW UN 230 240 Vac NM 40 A 2 pole 8 AWG Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U 17 Hardwire the UPS CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL Disconnect the mains input circuit breaker before installing or servicing the UPS or connected equipment Disconnect internal and external batteries before installing or servicing the UPS or connected equipment The UPS contains internal and external batteries that may present a shock hazard even when disconnected from the mains UPS AC hardwired and pluggable outlets may be energized by remote or automatic control at any time Disconnect equipment from the UPS before servicing any equipment Donot use the UPS as a safety disconnect Strain reliefs are not supplied with the unit Snap In strain reliefs are recommended Failure to follow these instructions can result in equipment damage and minor or moderate injury Input hardwiring SRT5K 6K models Remove the 35 mm 1 38 in knockout panels
7. 2 to 104 Temperature Storage 15 to 45 C 5 to 113 F Operating 0 3 000 m 0 10 000 ft Maximum Elevation Storage 0 15 000 m 50 000 ft Humidity 096 to 95 relative humidity non condensing Protection Class IP 20 rating Note Charge the battery modules every six months during storage Environmental factors impact battery life Elevated ambient temperatures high humidity poor quality mains power and frequent short duration discharges will shorten battery life Physical SRT5K model The UPS is heavy Follow all lifting guidelines Lifting guidelines gt 55 kg 2120 Ib Unit weight batteries included without 54 6 kg 120 Ib packaging Unit weight batteries included with packaging Rack Mount models 63 6 kg 140 Ib Tower models 67 kg 147 4 Ib Height x Width x Depth Unit dimensions without packaging 130 mm x 432 mm x 719 4 mm Height x Width x Depth 5inx17inx283 in Unit dimensions with packaging 330 mm x 610 mm x 960 mm 13 in x 24 in x 37 8 in The model and serial numbers are on a small label located on the rear panel SRT6K model The UPS is heavy Follow all lifting guidelines Lifting guidelines 255 kg 2120 Ib Unit weight batteries included without packaging 60 kg 132 Ib Unit weight batteries included with packaging 67 kg 147 4 Ib Unit dimensions without packaging 174 mm x 432 mm x 719 4 mm Height x Width x Dept
8. APC by Schneider Electric Installation Guide Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install operate service or maintain the UPS The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed The addition of this symbol to a Warning or Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in minor or moderate injury CAUTION CAUTION addresses practices not related to physical injury including certain environmental hazards potential damage or loss of data Safety Information Adhere to all national and local electrical codes All wiring must be performed by a qualified electrician Changes and modifications to this unit not expressly approved by APC could void the warranty This UPS is intended for indoor use only Do not operate this UPS in direct sunlight in contact wit
9. Mount 30 40 Rear Panel Features Note Refer to the table to identify rear panel features page 15 that provides a key to the callout numbers for the rear panel graphics depicted in this manual SRTSKXLI SRTSKRMXLI 8 m6 ER E r3 T Ex es E i su0878a O e i e 2 um i 9 SRTSKXLT SRTSKRMXLT x e 2 Hc Gm SE QJ 8L aN Clo E ele e 12 Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U SRTSKXLT IEC SRTSKRMXLT IEC of Output 50 60 Hz 208 240 VAC GROUP 2 20 AMP MAX d O N pom GROUP 1 15 i x L 3 3 E 527 SRTSKRMXLW HW o KJ 0881
10. PS On Line SRT5K 6K Tower Rack Mount 30 40 Key to identify rear panel features SmartSlot The SmartSlot can be used to connect optional management accessories External battery Use the external battery cable on XLBP to connect the UPS and XLBP power and XLBPs provide extended runtime during power outages The UPS will automatically recognize communication up to 10 external battery packs connector Chassis ground The UPS and XLBPs have ground screws for connecting the ground leads Prior to connecting a g 5 g the g 5 Screws ground lead disconnect the UPS from mains power Hardwire output SRTSKRMXLW HW SRT6KXLI SRT6KRMXLI SRT6KXLT SRTGKRMXLT box SRT6KXLT IEC SRTGKRMXLT IEC models are equipped with a hardwire output box Refer to Wiring Specifications on page 11 for hardwire specifications Remove the knockouts Snap In strain reliefs are recommended not supplied terminal The Emergency Power Off terminal allows the user to connect the UPS to a central system Serial Com The Serial Com port is used to communicate with the UPS Use only interface kits supplied or approved by APC by Schneider Electric Any other serial interface cable will be incompatible with the UPS connector UsB port The USB port is used to connect either a server for native operating system communications or for software to communicate with the UPS Note Serial and USB commun
11. ack Failure to follow these instructions can result in equipment damage and minor or moderate injury Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 es Quo 900 999 After the UPS is hardwired to branch circuit mains complete steps 6 8 Lee Y ym Y 5 a ae rr Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 Tower Installation CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL The equipment is heavy Each battery module weighs 17 kg 37 Ib Always practice safe lifting techniques adequate for the weight of the equipment Remove the battery modules before installing the UPS Use the battery module handle to slide the battery modules in or out of the UPS Do not use the battery module handle to lift or carry the battery module Failure to follow these instructions can result in equipment damage and minor or moderate injury After the UPS is hardwired to branch circuit mains complete steps 6 8 10 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 11 Smart UPS On Line SRT5K 6K Tower Rack
12. angle adjustment The angle of the LCD display interface can be adjusted for ease in viewing the displayed messages Remove the front bezel Locate the button on the bottom of the display interface panel Press the button and slide the bottom of the LCD display interface screen out An audible click will be heard ROOM when the screen reaches the maximum angle ER 0 Nd e 1 22 Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 Select models are ENERGY STAR qualified For more information go to www apc com site recycle index cfm energy efficiency energy star ENERGY STAR Customer support and warranty information are available on the APC web site www apc com 2014 APC by Schneider Electric APC the APC logo Smart UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of EN 990 5090B their respective owners 12 2014
13. circuit mains must be performed by a qualified electrician 230 V models only In order to maintain compliance with the EMC directive for products sold in Europe output cords attached to the UPS must not exceed 10 meters in length The protective earth conductor for the UPS carries the leakage current from the load devices computer equipment An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors The conductor will typically be green and with or without a yellow stripe The UPS input ground conductor must be properly bonded to protective earth at the service panel If the UPS input power is supplied by a separately derived system the ground conductor must be properly bonded at the supply transformer or motor generator set Battery safety Before installing or replacing the batteries remove jewelry such as wristwatches and rings High short circuit current through conductive materials could cause severe burns Do not dispose of batteries by burning them The batteries may explode Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes and may be toxic Hardwire safety Verify that all branch circuit mains and low voltage control circuits are deenergized and locked out before installing cables or making connections whether in
14. h 6 9 in x 17 in x 28 3 in Unit dimensions with packaging 370 mm x 610 mm x 960 mm Height x Width x Depth 14 6 in x 24 in x 37 8 in The model and serial numbers are on a small label located on the rear panel Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U Battery Battery type Maintenance free leak proof sealed lead acid Replacement battery module This UPS has hot swappable battery modules Replacement is a safe procedure isolated from electrical hazards Refer to the appropriate replacement battery user manual for installation instructions Contact your dealer or go web site www apc com for information on replacement batteries 140 Number of battery modules 2 battery modules Voltage for each battery module Total voltage for the UPS Ah rating 96 V 192 V 5 1 Ah per battery module XLBP cable length 500 mm 19 7 in Electrical Models SRTSKXLT SRTSKRMXLT SRTSKXLT IEC SRTSKRMXLT IEC SRTSKXLI SRTSKRMXLI Rating 5 4 25 kW 5 4 5 kW SRTSKRMXLW HW SRT6KXLT SRT6KRMXLT SRT6KXLT IEC 6 6 kW SRT6KRMXLT IEC SRT6KXLI SRT6KRMXLI Output Output Frequency SRTSKRMXLW HW 208V 220V 230V 240V Nominal Output Voltage SRT5K 6KXLT XLT IEC SRTS5K 6KRMXLT XLT IEC 208V 240V Input 50 Hz 60 Hz 3 Hz SRTSK 6KXLI SRTSK 6KRMXLI 220V 230V 240V In
15. h fluids or where there is excessive dust or humidity Besure the air vents on the UPS are not blocked Allow adequate space for proper ventilation with a factory installed power cord connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords battery typically lasts for two to five years Environmental factors impact battery life Elevated ambient temperatures poor quality mains power and frequent short duration discharges will shorten battery life equipment is heavy Always practice safe lifting techniques adequate for the weight of the equipment The batteries are heavy Remove the batteries before installing the UPS and external battery packs XLBPs in a rack Always install XLBPs at the bottom in rack mount configurations The UPS must be installed above the XLBPs Always install peripheral equipment above the UPS in rack mount configurations Additional safety information can be found in the Safety Guide supplied with this unit Deenergizing safety The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit mains Before installing or servicing the equipment verify the following Mains circuit breaker is in the OFF position Internal UPS the batteries are removed XLBP battery modules are disconnected Electrical safety For models with a hardwired input the connection to the branch
16. ication should not be used simultaneously Use either the Serial Com or the USB port Universal port Use to connect Temperature sensor AP9335T supplied Temperature humidity sensor AP9335TH not supplied Relay input output connector 9810 not supplied supports two input contacts and one output relay Console port Use the Console port to configure the network management features Q Network port Use the Network port to connect the UPS to the network Q Reset button Use the Reset button to restart the Network Management Interface Note A restart of the Network Management Interface does not affect UPS operation input SRTSKXLT SRTSKRMXLT SRTSKXLT IEC SRTSKRMXLT IEC models have factory power cable or installed input power cables hardwire input All other models are equipped with a hardwire input box box Refer to Wiring Specifications on page 11 Remove the knockouts Snap In strain reliefs are recommended not supplied Controllable Connect electronic devices to these outlets outlet group 1 Controllable Connect electronic devices to these outlets outlet group 2 Controllable Connect electronic devices to these outlets outlet group 3 Circuit breaker In the event an overload condition occurs disconnect nonessential equipment Then reset the circuit breaker Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U Wiring Specifications CAUTION DAMAGE TO EQUIPMENT OR
17. ons Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 3 Package Contents Inspect the contents upon receipt Notify the carrier and dealer if the unit is damaged Included with all models Front bezel 0 PPO PDP BO Boe oOoooocooo oo oooooooooo Oooooooooo Console to DB9 cable EPO Terminal block User Documentation CD RJ45 to DB9 cable Temperature sensor probe Arc a Network Management Utility CD USB cable are ee Included with Tower and SRTSKRMXLW HW models only 2 pairs stabilizer brackets 4 flat head screws to secure tower stabilizer brackets to the UPS Included with XLI XLT IEC models only 2 m in length 2 output power cords 1 2 m in length Included with Rack Mount models only Rail Kit with instructions and hardware 1 pair rack mount brackets for installing rails in a rack 8 flat head screws to secure rack mount brackets to the UPS 4 ornamental screws to secure rack mount brackets to the rails 2 cage nuts x2 x4 GD x8 Smart UPS On Line SRT5K 6K Tower Rack Mount 3U 4U Specifications For additional specifications refer to the APC web site www apc com Environmental Operating 0 to 40 C 3
18. put Frequency 40 HZ 70 Hz 3 Hz Nominal Input Voltage SRTSKRMXLW HW 208 V 220 V 230 V 240 V SRT5K 6KXLI SRTSK 6KRMXLI 220 V 230 240 V SRT5K 6KXLT XLT IEC SRTS5K 6GKRMXLT XLT IEC 208 V 240 V Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 Remove Battery Modules CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL The equipment is heavy Each battery module weighs 17 kg 37 Ib Always practice safe lifting techniques adequate for the weight of the equipment Remove the battery modules before installing the UPS Use the battery module handle to slide the battery modules in or out of the UPS Do not use the battery module handle to lift or carry the battery module Failure to follow these instructions can result in equipment damage and minor or moderate injury Use the battery module handle to lift and slide the battery modules out of the UPS 108432 Rack Mount Installation Refer to the Rail Kit Installation Guide for instructions on rail installation CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL The equipment is heavy Always practice safe lifting techniques adequate for the weight of the equipment Always use the recommended number of screws to secure brackets to the UPS Always use the recommended number of screws and cage nuts to secure the UPS to the rack Always install the UPS at the bottom of the rack Always install the XLBP below the UPS in the r
19. the junction box or to the UPS Wiring by a qualified electrician is required Check national and local codes before wiring Strain relief is required for all hardwiring not supplied openings that allow access to UPS hardwire terminals must be covered Failure to do so may result in personal injury or equipment damage Select wire size and connectors according to national and local codes General information The UPS will recognize as many as 10 external battery packs connected to the UPS However there is no limit to the number of XLBPs that can be used with the UPS Note For each XLBP added increased recharge time will be required The model and serial numbers are located on a small rear panel label For some models an additional label is located on the chassis under the front bezel Always recycle used batteries Recycle the package materials or save them for reuse Smart UPS On Line SRT5K 6K Tower Rack Mount 30 40 FCC Class A radio frequency warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are intended to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati
Download Pdf Manuals
Related Search
Related Contents
operational equipment & logistics solutions September1.48 MB - Four Winds BMW Riders Home 平成24年12月5日~6日イタリア国ローマ市ISO/TC 127/SC 1/WG 5 PXI Express NI PXIe-6672 User Manual prb chaux aerienne cl 90 TIG200PDC TIG Welder - R-Tech Welding Equipment Ltd Samsung GT-S3572 Korisničko uputstvo LabVIEW Real-Time Module Release Notes Samsung Кондиционер AR9000 с функцией ускоренного охлаждения, 12000 БТЕ/ч Инструкция по использованию Copyright © All rights reserved.