1. Batteries are connected in se ries with Plus connected to Minus STEP 8 If batteries are installed on their side make sure to apply an insulator to the top of the battery termi nal to prevent the battery terminals from shorting to the metal enclosure in case the battery shifts inside the en closure during an earthquake STEP 9 Set the proper voltage on the AC input of the controller by removing the metal tab and then switch ing the input voltage to 120VAC or 240VAC depending on your source voltage Be sure to replace the metal tab to ensure that somebody doesn t accidentally switch the voltage as this will damage the controller STEP 10 Connect the battery cables to the controller then to the battery Be sure to observe proper polarity Black wire connects to bat tery negative terminal and BATTERY terminal on the controller STEP 11 When a battery is connected properly the BATT LED will be green Make sure that the Battery Type is selected correctly and never change the battery type during charging or this could damage the controller Use GEL for GEL or AGM batteries Use WET for standard lead acid wet cells Tycon recommends using only GEL or AGM batter ies for best performance The controller has battery overdischarge protection to disconnect the load if the battery voltage charge is too low The LOAD LED will be on when the battery charge is within safe limits and the LOAD output is turned on LED Indic
2. UPS ST24 300W UBNT Power UPSPro Backup Systems Power System Wireless Base Stations gt Surveillance Cameras Remote Gate Control Electric Fence 2 Up to 192W loads Congratulations on your purchase of the UPSPro outdoor backup power system Please take a moment to review this Qwik Install Guide before assembly or battery installation DANGER Avoid Powerlines You Can Be Killed When following the instructions in this guide take extreme care to avoid contact with overhead power lines lights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules c Perform as many functions as possible on the ground o Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet 2 Make sure there are no people pets etc below when you are working on a roof or ladder Recommended Tools Phillips Screwdriver 13mm and 10mm Open End Wrench 8mm nut driver Flat Blade Screwdriv X Please help preserve the environment and return used batteries to an authorized depot RE Qwik Install STEP 1 Add Grounding Wire Between Door and Enclosure Remove plastic covers on cop per studs on inside of door and inside of enclosure Add jumper wire between 2 copper studs and use copper washers and
3. ators LOAD Load Power is Turned On Green PWR AC Power On Yellow BATT Battery is Connected Green CHD Battery is Fully Charged Green CHG Battery is Charging Yellow WET GEL Switch is positioned to WET Green or GEL Yellow STEP 12 Switch off controller and connect AC to the controller Be sure to follow local regulations for outdoor 120 240VAC connec tions STEP 13 Connect the load to the controller LOAD terminals Be sure to observe proper polarity Switch on the controller to activate the charging STEP 14 Plug or Tighten all wire feedthrus If they don t tighten on a small diameter wire you can wrap some electrical tape around the wire in the seal area to increase its diameter and make a better seal The enclosure needs some small amount of venting so be sure NOT to seal all holes and feedthrus with silicon STEP 15 Make sure lid gasket is clean and free from any parti cles then carefully close the cover making sure that wires are clear of the seam and hinge area Use the special key to close the two cover locks SPECIFICATIONS Subject to change without notice UPS ST24 UBNT EL PF 2 battery 51Ah 1200VA Available Storage Capacities 4 battery 102Ah 2400VA Battery Type Valve GSG Sealed Lead Acid WET Equalize 28 8V Float 26 4V GEL Equalize 28 4V Float 27V Over discharge protection VAC Input Current 3 5A 115VAC 1 8A 240VAC Fuse 6A Internal Replaceable Enclosure Typ
4. e Powder Coat Steel Operating Temperature 30 C to 60 C TECH CORNER Additional Information you may find useful Charge Voltage 1 CONTROLLER The controller turns off power to the load 21 5 and reconnects when the battery reaches 25 2V This protects battery from overdischarge and increases battery life and performance Note The load will turn on immediately as soon as AC power is restored 2 CAPACITY The UPSPro UPS ST24 is rated at 192W load out put It can deliver 288W to the load but then the power available for bat tery charging is too small so we recommend not to exceed 192W to the load for best performance 3 VENTING The enclosure is vented thru the wire feedthrus and vari ous hole plugs in the bottom of the enclosure Don t make these airtight with silicon 4 BATTERY MAINTENANCE The batteries used in the UPSPro sys tems don t require any maintenance They should last up to 5 years in normal use Note Never store batteries for any length of time in a dis charged state or it will kill the battery 5 BATTERY OVERDISCHARGE We highly recommend hooking all equipment loads to the controller voltage output This output will dis connect the load if the battery voltage drops below the set voltage and this will protect the battery from over discharge If batteries get com pletely discharged because the equipment was connected directly to the battery you will reduce the battery life Discharged batteries will
5. freeze at very low temperatures 6 ACCESSORIES Tycon also offers a variety of voltage conver sion products to meet almost any need Just visit tyconpower com for more info Limited Warranty The UPSPro products are supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following 2 Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external amp internal parts Products that have been opened altered or defaced Water damage for units that were not mounted according to user manual Usage other than in accordance with instructions and the normal intended use o o o o 8000027 Rev 1 UPS ST24 300W UBNT UPSPro Qwik Install Guide 8
6. nuts to secure STEP 2 Add wire feedthrus into the bottom connector plate Attach the connector plate to the bottom of the enclosure using self tapping screws provided STEP 3 Install hole plug in drain hole in bottom right corner of the en closure STEP 4 Mount the DIN rail to the door using screws provided Mount any extra equipment to the orange backplate and secure the backplate in the enclosure Note The DIN rail can also be mounted to the orange backplate if desired STEP 4 If pole mounting the en closure assemble the pole mount kit to the back of the enclosure and mount the enclosure to a pole using the 6 hose clamps provided The en closure can also be wall mounted using the 4 holes in the back of the enclosure STEP 5 Insert the battery platform in the bottom of the enclosure The battery platform has cutouts so wires can be routed under the battery as needed STEP 6 Attach the green DIN Rail adapt ers to the 8 port POE switch using the screws Jr provided Clip the POE switch to the DIN rail Connect a cable from the controller LOAD output to the 8 port POE switch green voltage in connector V and V There are two V and two V inputs Either input is fine to use Just make sure polarity is correct T STEP 7 Install the batteries in the enclosure If using multiple bat teries connect in series for 24V output 24V two battery and 24V four battery configurations are shown below