Home

INSTEON 2634-222 remote power controller

image

Contents

1. Maximum load 15 Amps 1800 Watts for incandescent loads Minimum load None User replaceable fuse None Retains all settings without power Yes saved in non volatile EEPROM Standby power consumption lt 1 watt Safety approval s Conforms to ANSI UL Std 508 2005 Certified to CAN CSA Std C22 2 14 05 FCC ID Page 10 of 13 SBP26342 2634 222 Rev 1 21 2014 7 45 AM Troubleshooting is not turning on and won t control the load On Off Outdoor Module won t link to or work with a controller not be getting power The controller or might have been reset without unlinking On Off Outdoor Module Problem Possible Cause Solution The Status LED on On Off Outdoor Module On Off Outdoor Module may Make sure On Off Outdoor Module is not plugged into a switched outlet that is turned off Re link On Off Outdoor Module to the controller The controller and On Off Outdoor Module may be on opposite powerline phases Make sure a least one other INSTEON dual band device is properly installed to bridge the two powerline phases The INSTEON signal may be too weak Add additional INSTEON devices or move around existing INSTEON devices All INSTEON devices act as INSTEON network repeaters Large appliances such as refrigerators or air conditioners may be producing electrical noise on the powerline Other electrical devices such as computers television
2. Please see the instructions that came with your GFCI device for specific testing procedures When in doubt of the GFCI device s ability to detect a ground fault replace the GFCI device Don t bury On Off Outdoor Module any electrical cable or component connected to it A buried power cord may result in electrocution if improper cables are used or if digging occurs over the cable Don t allow vegetation to grow on or around On Off Outdoor Module Don t install On Off Outdoor Module in a manner that allows water to accumulate around it If an extension cord is used the cord must be properly grounded Be sure the extension cord is of adequate capacity to provide power to your load A light duty or medium duty extension cord may cause a voltage drop which will cause overheating of the cable plug or socket Don t attempt to open On Off Outdoor Module The case is sealed and can t be opened There are no user serviceable parts inside Don t use On Off Outdoor Module to control devices that preserve maintain or contribute to human or animal safety or life support Don t plug On Off Outdoor Module into an outlet controlled by a switch because if the switch is inadvertently turned off On Off Outdoor Module won t have power Don t plug On Off Outdoor Module into a filtered power strip or AC line filter Be sure the device s built in switch is in the on position Don t exceed the load rating of On Off Ou
3. Le EE 13 FCC and Industry Canada Compliance Statement nnn annees erenenennneneneerensernenensnnneeeneevenerneneeenneenennerenn 13 ET UE Wafning Safety Warnind sn Aaah eaten toeten atleet nnn deld 13 Limited N arany EE 13 Page 2 of 13 2634 222 Rev 1 21 2014 7 45 AM About On Off Outdoor Module On Off Outdoor Module is a simple way to remotely control any plug in device in or outside your home at the touch of a button Send commands to On Off Outdoor Module from any INSTEON controller or link it to other INSTEON devices as a controller Set button LED i Outlet Features and Benefits Installs and links to other INSTEON devices in minutes Controls standard incandescent loads up to 1800 Watts and inductive loads up to 15 Amps Weatherproof to withstand harsh outdoor conditions Indicates INSTEON setup mode activity and operational states with a dual color Status LED and beeper Load Sensing easily enabled and disabled Stores setup state in memory so settings aren t lost during power outages Two year warranty In the Box Optional Accessories On Off Outdoor Module Mini Remote Quick Start Guide INSTEON Hub Page 3 of 13 2634 222 Rev 1 21 2014 7 45 AM Before Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference On Off Outdoor Module is intended for installation in accordance with the National Elec
4. factory follow up inspections to verify continued conformance FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and Industry Canada RSS 210 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorise aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible d en compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user
5. follow these directions Note If you ever wish to uninstall On Off Outdoor Module it is important that you remove all On Off Outdoor Module responder links Otherwise controllers will repetitively retry commands creating network delays 1 Press and hold controller button until it beeps LED will start blinking green 2 Press and hold controller button until it beeps again LED will start blinking red 3 Press and hold On Off Outdoor Module set button until it double beeps Controller LED will stop blinking 4 Test by tapping controller button on and off On Off Outdoor Module will no longer respond Page 7 of 13 2634 222 Rev 1 21 2014 7 45 AM Remove On Off Outdoor Module as a Controller If you no longer want On Off Outdoor Module to control another device or are removing On Off Outdoor Module from your network it is important that you follow the instructions below for each responder 1 Press and hold On Off Outdoor Module set button until it beeps LED will start blinking green 2 Press and hold On Off Outdoor Module set button until it beeps again LED will start blinking red 3 Press and hold responder set button until it double beeps On Off Outdoor Module will double beep and LED will stop blinking 4 Test by tapping On Off Outdoor Module on and off Former responder will not respond Load Sensing Load Sensing allows you to control the load plugged into On Off Outdoor Module from its local switch in addition to any linked controlle
6. is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ETL UL Warning Safety Warning CAUTION To reduce the risk of overheating and possible damage to other equipment do not install this device to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance Gradateurs commandant une lampe a filament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente ou un appareil alimente par un transformateur Limited Warranty Seller warrants to the original consumer purchaser of this product that for a period of two years from the date of purchase this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner s Manual This warranty shall not apply
7. set button until it double beeps Controller will double beep and its LED will stop blinking 4 Test link by tapping controller button on and off Lamp connected to On Off Outdoor Module will respond appropriately Note The link just created is one way See Make On Off Outdoor Module a Controller or Groups to add another link to keep the two products in sync If you wish the load to be off when link is activated such as for an all off scene turn off the load in step 2 Make On Off Outdoor Module a Controller 1 Press and hold On Off Module set button until it beeps On Off Module LED will start blinking green 2 Adjust responder to desired brightness state such as on 50 or even off 3 Press and hold responder set button until it double beeps On Off Module LED will stop blinking 4 Test by tapping On Off Module set button to turn on off Responder will respond appropriately Page 6 of 13 2634 222 Rev 1 21 2014 7 45 AM Groups Devices in a group share all the same settings eg on level ramp rate This keeps all group members synchronized Every device in a group is both a controller of and responder to all the other devices The most common example of a group is a 3 way lighting circuit 2 switches For simplicity we will assume that the desired group level is on The following steps will create a virtual 3 way circuit including device A and device B 1 Turn A and B on 2 Press and hold A se
8. On Off Outdoor Module Owner s Manual 2634 222 INSTEON Page 1 of 13 2634 222 Rev 1 21 2014 7 45 AM TABLE OF CONTENTS About On Off Outdoor dk II 3 Features and Die better tee Sb saci EES EE EE 3 Before E CU RE A INECC UE a EE 4 Using On Off Outdoor Module 21 aa r a aea E aa a a ra a eaaa SeEEEE E 5 Local Control Operation EE 5 Be V0 117 EE 5 AdiusttocalSettl regeiert Seeerei See 5 LED OMOF Of gelehen eet eebe 5 BUNA OT RE 5 PLOQTAMIMING LOCK rte deinde atelier eee d yates dele Witre and 5 INSTEON Setup WEE 6 INSTEON Controllers Responders and Links 6 Make On Off Outdoor Module a Responder unne enenenenneerene nnee nenenennereenernnenenneenenerneneennnnenene eenen 6 Make On Off Outdoor Module a Controller eneen nn nennenenensers vennen enen ense en venwenenensene ve nvnneneneen 6 EE H er 7 Remove On Off Outdoor Module as a Responder nnen ennenenneereneenenenenneenenserneneennnnenensenvenvernensnenneenenvenn 7 Remove On Off Outdoor Module as a Controller nen enenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenenen 8 L ad SOMS IMG EE 8 Enable Load SCNSING EE 8 Disable Load Sensing wesen ereraad terne enden rennen eed daer lms iletaadsaande ea eed haer E AEEA 8 el EE LU el 9 Bee le e le D 11 Phase Bridge Detect Beacon RF Range Test 12 Factor FOSOU aroa soup e a aces cade athe Nein E 12 Certification and Warranty 2 0 Seege 13 E e te In sch E ERE A E te etn ie
9. bridge Relocate if necessary and practical or add an additional dual band device RF Range Test e RF range test if LED is blinking Device is within RF communication range e RF range test if LED is not blinking Device is not within RF communication range Relocate if necessary and practical or add an additional dual band device 3 Tap Set button On Off Outdoor Module will stop beeping Other device LEDs will stop blinking Factory Reset All settings links and scenes will be erased 1 If you are using a controller to control On Off Outdoor Module be sure to unlink it from the controller 2 Unplug On Off Outdoor Module 3 While pressing and holding Set button plug On Off Outdoor Module back in Do not let go of set button On Off Outdoor Module will begin to emit a long beep Status LED will turn green 4 When long beep stops release set button Status LED will flash red and then turn green After a few seconds load will turn on Page 12 of 13 2634 222 Rev 1 21 2014 7 45 AM Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO a nationally recognized independent third party testing laboratory The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U S and Canadian device safety standards that the manufacturing site has been audited and that the manufacturer has agreed to a program of quarterly
10. load is off Blink on Traffic Default enabled This setting is only adjustable via software or a central controller On Off Outdoor Module LED will blink green for INSTEON traffic and if it detects noise that could disrupt communication Programming Lock Default disabled This setting is only adjustable via software or a central controller When enabled Programming Lock will disable the set button so that a user can not adjust settings or modify links This is typically used in commercial or installer applications Page 5 of 13 2634 222 Rev 1 21 2014 7 45 AM INSTEON Setup Some products have subtle differences in their setup procedures Please refer to the other devices owner s manuals for details INSTEON Controllers Responders and Links Let s define a few terms e The INSTEON transmitter is called a controller e The INSTEON receiver is called a responder e The association between the controller and responder is called a link Link Controller Responder Note that a link is one way If you wish to have control the other way simply add a link the other way Make On Off Outdoor Module a Responder 1 Press and hold controller set button until it beeps Controller LED will start blinking You will have four minutes to complete the next steps before linking mode times out 2 Use On Off Module set button to adjust load to desired state on or off 3 Press and hold On Off Outdoor Module
11. perate incorrect operation or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home In no event shall Seller be liable for special incidental consequential or other damages resulting from possession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to state Protected under U S and foreign patents see www insteon com patents Copyright 2013 INSTEON 16542 Millikan Ave Irvine CA 92606 866 243 8022 www insteon com Page 13 of 13 2634 222 Rev 1 21 2014 7 45 AM
12. rs Load Sensing is disabled on On Off Outdoor Module by default but you can enable it by following these steps Enable Load Sensing 1 Press and hold On Off Outdoor Module set button until it beeps 3 seconds On Off Outdoor Module Status LED will begin blinking green 2 Triple tap On Off Outdoor Module set button Be sure to quickly press the set button like clicking a computer mouse On Off Outdoor Module Status LED will stop blinking and turn on solid green if the load is on or solid red if it is off 3 Test by turning the load on and off from its built in switch Load will turn on and off Disable Load Sensing 1 Press and hold On Off Outdoor Module set button until it beeps 3 seconds On Off Outdoor Module Status LED will begin blinking green 2 Double tap On Off Outdoor Module set button Be sure to quickly press the set button like clicking a computer mouse On Off Outdoor Module Status LED will stop blinking and turn on solid green if the load is on or solid red if it is off 3 Test by turning the load on and off from its built in switch Load will not respond Page 8 of 13 2634 222 Rev 1 21 2014 7 45 AM Specifications General Product name On Off Outdoor Module Brand manufacturer INSTEON Manufacturer product number 2634 222 UPC 813922013375 Warranty 2 years limited INSTEON INSTEON powerline mesh repeater Yes INSTEON RF mesh repeater Yes INSTEON controller Yes INSTEON re
13. s or power strips may be absorbing the INSTEON signal Install a power line noise filter 1626 10 to filter electrical noise and minimize signal attenuation On Off Outdoor Module is taking a long time to respond to a controller The controller may be sending commands to a responder that is no longer in use Commands for the unused responder are being resent and loading down the signal Unlink any unused responders from the controller HINT If you are using home automation software you can easily check scene membership and eliminate unnecessary links If the above doesn t work perform a factory reset on the controller The load turned on by itself Another controller or timer could have triggered On Off Outdoor Module Perform a factory reset See Factory Reset The controller can turn off On Off Outdoor Module but On Off Outdoor Module does not turn on when send an ON command from the controller On Off Outdoor Module may be Linked at its off state Relink On Off Outdoor Module to the controller while the load is on See Make On Off Outdoor Module a Responder On Off Outdoor Module is locked up The load is not being controlled by On Off Outdoor Module A surge or excessive noise on the powerline may have glitched it The load may not be getting power Unplug On Off Outdoor Module for 10 seconds and then reinstall If the above doesn t work perform a factory rese
14. sponder Yes Maximum links scenes 400 Green when load is on red when load is off RF range SE Blinks red or green during setup Beep on button press No Local control Yes On Off Commands supported as controller On Of Commands supported as responder Beep Software configurable Yes Up to 150 feet open air Range may vary due to local interference Phase bridge detect beacon Yes INSTEON device category 0x02 switched lighting control INSTEON device subcategory 0x38 US 915 MHz RF frequency N A Mechanical Mounting Type A US AC Outlet Wires N A Max Cable Size N A Min Cable Size N A Page 9 of 13 2634 222 Rev 1 21 2014 7 45 AM Screw On Off Outdoor Module None connections Case color Dark gray Set button Yes Plastic UV stabilized polycarbonate Beeper Yes LED 1 Red Green Ee 2 75 W x 4 32 H x 1 27 D with 6 lead 70mm W x 110mm H x 32mm D with 150mm lead Weight A65lbs 7 2 oz 21kg Operating environment Indoor outdoor Rainproof rated NEMA Type 3R Enclosure Operating temperature range 4 to 122 F 20 to 50 C Storage temperature range 4 to 158 F 20 to 70 C Operating humidity range 0 90 relative humidity Electrical Voltage 120 Volts AC 10 Frequency 60Hz Load type s Standard appliances up to 15 Amps and incandescent lights up to 1800 watts
15. t See Factory Reset Make sure the load s built in switch is in the on position If you have tried these solutions reviewed this Owner s Manual and still cannot resolve an issue you are having with On Off Outdoor Module please call INSTEON Support Line at 866 243 8022 Page 11 of 13 2634 222 Rev 1 21 2014 7 45 AM Phase Bridge Detect Beacon RF Range Test On Off Outdoor Module automatically bridges the electrical phases in your home via communications with other dual band devices on the other phase This is only important in 2 phase homes with powerline only INSTEON products or buildings with both 2 and 3 phase circuits The phase bridge detect beacon can also be used as an RF range test to see if your devices are within communication range You will need at least one other INSTEON dual band device installed 1 Quickly tap Set button four times On Off Outdoor Module will start beeping once per second LED will turn solid green 2 Check the LED behavior of other dual band devices Phase Bridge Detect Beacon e If the other dual band device is blinking green it is on the other phase Device provides a phase bridge to Micro module e If the other dual band device is blinking red it is on the same phase Device does not provide a phase bridge to Micro module Relocate if necessary and practical e If the other dual band device is not blinking Device is not within RF range of Micro module so it does not provide a phase
16. t button until it beeps A status LED will start blinking green 3 Press and hold B set button until it double beeps A will double beep and its LED will stop blinking 4 Press and hold B set button until it beeps B LED will start blinking green 5 Press and hold A set button until it double beeps B will double beep and its LED will stop blinking 6 Test by turning load on and off from A and then B The load s and both A and B LEDs will remain in synch Scenes Devices in a scene can each have different settings This provides for advanced scene creation Software is recommended for scene management Example of a scene with 1 controller and On Off Outdoor Module as a member 1 Press and hold controller set button until it beeps Controller LED will start blinking green 2 Tap controller set button Controller LED will start double blinking green 3 Use On Off Module set button to adjust load to desired state on or off Press and hold On Off Outdoor Module set button until it double beeps 5 For each additional scene member a Adjust member to desired scene brightness b Press and hold Set button until it double beeps 6 Tap controller set button Controller will beep and LED will stop blinking 7 Test by tapping controller button on and off On Off Outdoor Module and other scene responders will all respond appropriately Remove On Off Outdoor Module as a Responder If you no longer want a controller button to control On Off Outdoor Module
17. tdoor Module Check and add up all the electrical devices that will be attached and make sure the total does not exceed 15 Amps Don t use any electrical cord or extension cord that is damaged or in poor condition IMPORTANT If you have any difficulties or questions consult an electrician If you have any questions call the INSTEON Support Line at 866 243 8022 Installation 1 Plug appliance device also called the load you want to control into On Off Outdoor Module outlet 2 Plug On Off Outdoor Module into unswitched wall outlet Status LED will turn on solid green The load will turn on If load does not turn on tap Set button 3 Allow On Off Outdoor Module to hang down from outlet see image Note After completing installation you will not be able to use the load s built in switch to control the load unless you have enabled Load Sensing See Load Sensing Page 4 of 13 2634 222 Rev 1 21 2014 7 45 el Using On Off Outdoor Module Local Control Operation Connected load responders po Tap Double tap LED On Off On Off Green Set Button instant Status Setup Mode Solid green Solid red Load is off LED Activity Blinking green Linking mode Blinking red Unlinking mode Adjust Local Settings LED On or Off Default On This setting is only adjustable via software or a central controller When enabled LED On will cause the LED to be green when the Load is on and Red when the
18. to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage prepaid with proof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiving 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer Home automation devices have the risk of failure to o
19. tric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada On Off Outdoor Module is not designed nor approved for use on power lines other than 120V 60Hz single phase Attempting to use On Off Outdoor Module on non approved power lines may have hazardous consequences Prior to installing On Off Outdoor Module please review the entire installation procedure and take the following precautions Be sure On Off Outdoor Module is connected to a 3 prong AC outlet that includes a Ground Fault Circuit Interrupt GFCI feature If On Off Outdoor Module is plugged into an outlet without GFCI protection make sure there is a GFCI device upstream at another outlet closer to the electrical panel or a GFCI circuit breaker Test your GFCI protection each time On Off Outdoor Module is plugged in as well as on a monthly basis To test your GFCI protection make sure On Off Outdoor Module is plugged in and the connected load is on Then push the TEST button on the GFCI outlet or circuit breaker This unit must stop operating Wait about 5 seconds and then push the RESET button on the GFCI outlet or circuit breaker On Off Outdoor Module will begin receiving electricity and the connected load will turn on If the GFCI circuit does not perform in this manner there may be an electrical malfunction increasing the probability of electric shock Disconnect the power until the problem has been corrected