EK Water Blocks 3831109840771 hardware cooling accessory
Contents
1. Installation and mounting manual for EK XTOP D5 incl pump This product is intended for installation only by expert users Please consult with a qualified technician for installation Improper installation may result in damage to your equipment EK Water Blocks assumes no liability whatsoever expressed or implied for the use of these products nor their installation The following instructions are subject to change without notice Please visit our web site at www ekwb com for updates Before installation of this product please read important notice disclosure and warranty conditions printed on the back of the box Before you start using this product please follow these basic guidelines 1 Please carefully read the manual before through before beginning with the installation process 2 The EK High Flow and EK PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o ring gaskets 3 The use of corrosion inhibiting coolants is always recommended for any liquid cooling system Unscrew the ribbed threaded ring that attaches the Laing pump s 1 Install the EK XTOP D5 on to the pump main original factory top and the main pump core housing with motor motor housing Make sure you install EK provided 61x3mm o ring gasket Reseat the gasket if needed You can rotate the pump and use it in any direction to best suit your installation Factory original Secure the XTOP D5 usin
2. g enclosed M4x16 Store the original top the original o ring gasket and the attaching ring in a safe place pump top DIN7380 screws with the enclosed Allen hex key Do not over tighten the screws as excessive force may strip the threading l Attach the mounting plate on the bottom of D5 pump body with the pump top using the two enclosed motor countersunk M4x10 DIN7991 screws Twist LEFT to unscrew Screw in the fittings in the G1 4 threaded openings on plastic top of the water block EKWB recommends using EK PSC fittings with the EK XTOP D5 series pump tops To ensure that the tubes are securely attached to the barb fittings please use hose clamps or an appropriate substitute To radiator or water block It is mandatory to use the correct INLET and OUTLET ports 1 The OUTLET pressure port is the G1 4 threaded opening on the side of the pump top housing Additional OUTLET port is located on the upper right edge of the pump s front plate Please refer to the picture on the right 2 The INLET port suction port is the central G1 4 threaded opening on the EK XTOP D5 front face plane Please refer to the picture on the right Use reservoir to feed the pump in order to prime it Connect reservoir outlet port with EK XTOP D5 inlet port This water pump amp EK XTOP D5 combo can be used in any mounting configuration position apart from being mounted upside down Mounting the pump upside down may result in pump runni
3. ng dry and eventually lead to premature failure of the pump Alternative OUTLET port A ok ne is Oe HD C aor From reservoir Mounted upside down NOT OK VERY IMPORTANT NOTICE Once the installation is completed it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer We recommend a 24 hour leak test prior to powering up the computer Do not test the water block using tap water pressure This will rupture the top of the housing and render the block unusable and will void your warranty While all efforts have been made to provide the most comprehensive tutorial possible EK Water Blocks assumes no liability expressed or implied for any consequential damage s occurring to your equipment as a result of using EK Water Blocks cooling products either due to errors or omissions on our part in the above instructions or due to failure or defect in the EK Water Blocks cooling products WARRANTY Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user During this period products will be repaired or have parts replaced at our discretion provided that I the product is returned to the agent from whom it was purchased II the product has been purchased by an end user and has not used for commercial purposes III the product has not been misused handled carelessly or used in a manner
4. other than in accordance with the instructions provided describing its installation and proper use This warranty does not confer rights other than those expressly set out above and does not cover any claims for consequential loss or damage This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer This warranty is voided if the product comes in contact with aggressive UV additives or other improper liquids Any other RMA issues can be reported to www ekwb com support for further analysis REQUIRED TOOLS allen key 2 5mm Revision 1 0 Released on 1 of June 2012
Download Pdf Manuals
Related Search
Related Contents
Références utilisées - Académie de Créteil Cables Direct 2.0m LC-SC 62.5/125 MMD OM1 CD-ROMドライブ取扱説明書 新株式発行並びに株式売出届出目論見書 - ポールトゥウィン・ピットクルー Deutsch - Ectaco Service Manual For 商品および取扱説明書には、 お使し\になる方や他人へ Quantum O+M Manual Copyright © All rights reserved.
Failed to retrieve file