Home

NEC MultiSync MD302C6

image

Contents

1. How to attach an arm stand 1 Place a soft cloth or cushioning material over a stable even surface 2 Putthe display face down on the soft cloth 3 Remove 4 screws and detach the tilt stand using a Phillips head screwdriver 10 M4 Max Depth 9 mm Center of the display area Cushioning material 4 Attach an arm stand NOTE Do not try to attach the panel to the arm that is already fixed in place by yourself Ask for assistance of another person Tipping the panel over or dropping it could cause damage and or injury English 29 Antitheft Security Slot The display is equipped with the security slot for use with the MicroSaver Security Lock System by Kensington Technology Group The MicroSaver locks are available at PC supply stores Note Kensington is the registered trademark of Kensington Technology Group English 30 Manufacturers Recycling and Energy Information NEC DISPLAY SOLUTIONS is strongly committed to environmental protection and sees recycling as one of the company s top priorities in trying to minimize the burden placed on the environment We are engaged in developing environmentally friendly products and always strive to help define and comply with the latest independent standards from agencies such as ISO International Organisation for Standardization Dispos
2. NG CONFIGURATION 1 2 English 23 3 Confirming the configuration change Press the MENU button and return to the full main menu same as in step 1 Press either or button to move the cursor gt and select PRESENT STATE Full Menu M E p P D S S I D M E xmezzzemzz eZazvuosommc Jjcmca4douwo oOdooxzmza Press the MENU button and the PRESENT STATE submenu with the selected configuration number appears The following picture shows the case when configuration 2 was selected PRESENT STATE e v OQOrn0 gt ra wen m POD HDH z 4A Oz OH rou m O Amo z e eC v m N N L R I N A R O cOr xcm IB NF MI MM LO NOTE The OSD menu disappears in 15 seconds Automatic input source detection By default the automatic scanning for input signals is enabled The function is selectable as follows Automatic scanning setting 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor gt and select INPUT SOURCE AUTO SCANNING Input Source Auto Scanning x v OQ400zmz xmeoezzzemnzz AZZ IHHOMRC ACMEHHOVO o4 TI ZZ m WHHOA gt roozzo 4 muocaoozu E I P D S S I D M E 2 Changing the input signal scanning function Press the MENU button and the INPUT SOURCE AUTO SCANNING submenu appears INPUT SOURCE AUTO SCANNING URCE AUTO SCANNIN
3. DisplayPort cable x 2 Quick Reference Guide USB Cable DVI D to DVI D cable x 2 Remember to save your original box and packing material to transport or ship the monitor Dual link DVI cable Type and number of power cords included will depend on the where the LCD monitor is to be shipped When more than one power cord is included please use a power cord that matches the AC voltage of the power outlet and has been approved by and complies with the safety standard of your particular country English 7 English Connecting the cables To connect the LCD monitor to your system please follow these instructions NOTE M amp ke sure to read Recommended Use before installation In order to display the maximum resolution a display controller that can output a resolution of 3280 x 2048 is needed 1 Turn off the computer 2 DVI connection Connect the supplied digital signal cables between the display s DVI and the computer s DVI connector DisplayPort connection Connect the supplied DisplayPort cables between the display s DisplayPort and the computer s DisplayPort connector NOTE The recommended cable length is 2m If you use a longer cable the display may become unstable and flicker 3 Connect one end of the power cord to the AC inlet on the back of the display and the other end to the power outlet NOTE Please refer to the CAUTION section of this Installation amp Maintenance Guide for proper selection of AC power cord
4. It takes between 30 seconds to 1 minute to complete the test To cancel the test press either or button to select Yes for CANCEL TESTING 5 Showing the test results When the test has completed the results are shown similar as below Test result Maximun deviation DICOM CONFORMANCE E i ESULT Pas d Lt AX DEVIATION 1 3 Luminance status _ LUMINANCE Stable 7 LAPSED TIME Over 240min Elapsed time mre START TESTING Yes gt No Test result Start of test The result shown indicates the following status RESULT Explanation Passed Max deviation GSDF error lt 10 complies with AAPM TG18 guidelines for primary displays Failed Max deviation GSDF error gt 10 does not comply with AAPM TG18 guidelines for primary displays Canceled Test has been cancelled Passed When Passed or Failed is followed by the test has not been performed Failed 1 under the recommended condition minimum 60 minutes of active backlight time or the luminance is unstable LUMINANCE Explanation Stable Luminance is stable Unstable Luminance is unstable NOTE If the test is repeated within 30 seconds Unstable is shown for LUMINANCE and is show n for RESULT The test results are saved until the next test or calibration If the maximum deviation GSDF error result does not conform to the AAPM TG18 guidelines even though the test
5. UU m gt A m 9 x S M B HDH rou o z wn 245402 o m O Amd rad TING 0 COM GSD F e Gamma correction setting ear Base ADPDZHA ZZZ 0 0 T 0 I RE LU AM AL co LU GA CO rzzz OxX emu 2 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD menu appears Press either or button to move the cursor gt and select DICOM CONFORMANCE TEST Reference Menu Full Menu MENU INFORMAT ION PRESENT STATE DICOM CONFORMANCE TEST SWITCHING EDID SWITCHING CONFIGURATION INPUT SOURCE AUTO SCANNING DIRECT OSD SETTING MENU MENU SELECTION EXIT 3 DICOM conformance test submenu Press the MENU button and the DICOM conformance test submenu appears NOTE DICOM Conformance Test When the display has been calibrated to DICOM GSDF DICOM Conformance Test When the display has been calibrated to other gamma settings such as Gamma 2 2 When the display has not been calibrated to DICOM GSDF START TESTING is not shown If START TESTING is not shown select DICOM GSDF from the SWITCHING CONFIGURATION window English 19 4 Performing the DICOM conformance test Press either or button to select Yes for START TESTING DICOM conformance test starts immediately Screen that shows the test is in execution DICOM CONFORMANCE TEST Executing CANCEL TESTING Yes gt No
6. 4 Turn on the display and the computer Make sure that the main power switch on the back side of the display is turned on Back of the display DisplayPort cable Computer or DVI cable ce ol af To the wall outlet 5 To keep the cables neatly organized place them into the cable management system that is built into the stand Place the cables in the hooks firmly and evenly Figure A 6 Slide down the cable cover Figure B 7 Please check that you can still rotate raise and lower the monitor screen when you have installed the cables NOTE Handle with care when raising lowering rotating or tilting the monitor screen 8 Turn on the monitor with the front power switch Figure C and the computer NOTE If you have any problems please refer to the Troubleshooting section of this Installation amp Maintenance Guide Power switch Figure A Figure B Figure C English 8 N Caution For connection to the DVI input s make sure to use a DVI Dual Link cable Dual link Single link e Precautions to display two 3MP screens from one computer Figure D A display controller model which has two outputs of the same signal type either DVI DVI or DisplayPort DisplayPort is recommended Using two outputs with different signal types i e DVI DisplayPort of the same display controller is not recommended Doing so may resul
7. Setting of functions to be enabled Press the MENU button and the ENABLE FUNCTIONS submenu appears ENABLE FUNCTIONS Press either or button to move the cursor P and select the preferred function English 25 Enable Functions Explanation Disables both input signal switching and input port switching When you try disabled switching operation the menu will show LOCKED Disable INPUT1 DVI INPUT2 DisplayPort LOCKED Switching Input Source Enables input source switching only Enable Switching Input Source When you try input port switching the menu will show LOCKED Enables input port switching only Enable Switching Input Port When you try input source switching the menu will show LOCKED Enables both input signal switching and input port switching Enable Both Functions Disable is selected by default Press the MENU button and return to the Direct OSD Setting Menu in step 2 NOTE The OSD menu disappears in 15 seconds Selecting switching mode of an input signal 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor gt and select DIRECT OSD SETTING MENU Direct OSD Setting Menu nHO nomo z nmooz4 om zezm ZHd mo z eO o00zmz mucaoaozu ca HZAVRHOMTC 007 XMZSSHAaZzzZ ACMCHHOVO E I P D S S I
8. manual and adjust the frequency and or resolution e If the LED is red this may be an error indication Contact your supplier Images are not displayed properly The display resolution may not be appropriate for the display Refer to the computer instruction manual and adjust the resolution The refresh rate is set to 60Hz dual link mode and resolution loss scan line gaps occurs This can happen when a DVI Single Link cable or a DisplayPort to DVI Single Link adapter is used Use the supplied dual link cable which supports both single link 30Hz and dual link 60Hz modes or set the refresh rate to 30Hz English 28 Attaching a wall mount or multi display mounting arm The tilt and swivel stand as shipped with the display is interchangeable with commercially available wall mounts or multi display mounting arms that e Come with a mounting plate with 6 slotted screw holes at 100 mm x 200 mm and e Bear the total weight of the LCD panel without the stand and the cables connected to it For more information ask your mounting arm supplier Note Use the original screws to use the LCD panel back on its original tilt stand A A Choose the screw size carefully according to the mount plate thickness If the screws are too long they could damage the internal parts If they are too short the connection becomes loose and the display could fall out 1 5 3 5 mm ISO M4 x 12 Mounting plate thickness Screw size
9. D M E 2 Direct OSD setting menu Press the MENU button and the DIRECT OSD SETTING MENU screen appears DIRECT OSD SETTING MENU screen Press either or button to move the cursor gt and select INPUT SOURCE BUTTON MODE Direct OSD Setting Menu Explanation ENABLE FUNCTIONS Sets the selected function to be enabled INPUT SOURCE BUTTON MODE Selects switching mode for input signals EXIT Closes the submenu English 26 3 Selecting switching mode of an input signal Press the MENU button and the INPUT SOURCE BUTTON MODE submenu appears INPUT SOURCE BUTTON MODE TTON MODE Press either or button to move the cursor gt and select either mode INPUT SOURCE BUTTON MODE Explanation To change the input signal of INPUT 1 and INPUT 2 separately by pressing the or the button To change the input signal of INPUT 1 and INPUT 2 simultaneously by pressing the or the button Separate Mode Concurrent Mode Separate Mode is the factory default Press the MENU button and return to the Direct OSD Setting Menu in step 2 NOTE The OSD menu disappears in 15 seconds OSD operation without signal input from computer Without a signal input from the computer normally a display goes into energy saving mode and cannot show the OSD menu MD302C6 can exit the energy saving mode temporarily and shows the OSD menu in the normal operation mode Therefore it is poss
10. No 004 000 00345 4 Declaration of Conformity This device complies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation U S Responsible Party NEC Display Solutions of America Inc Address 500 Park Boulevard Suite 1100 Itasca Illinois 60143 Tel No 630 467 3000 Type of Product Display Monitor Equipment Classification Class B Peripheral Model MD302C6 C We hereby declare that the equipment specified above conforms to the technical standards as specified in the FCC Rules Classification Type of protection against electric shock CLASS equipment Degree of protection against electric shock No applied part Degree of protection against ingress of water as detailed in the current edition of IEC529 IPXO No protection Method of sterilization or disinfection recommended by the manufacturer Not Specified This device is not suitable for use in the presence of a flammable Anaesthetic Mixture with Air Oxygen or Nitrous Oxide No AP or APG category This device shall not be used in the vicinity of the patient which is the space with surfaces likely to be contacted by the patient or an attendant who can touch the patient This encloses a space within the room 1 83 m 6 feet beyond the perimeter of the bed in its
11. OPTIMUM PERFORMANCE PLEASE NOTE THE FOLLOWING WHEN SETTING UP AND USING THE LCD COLOR MONITOR WARNING Do not modify this equipment without authorization of the manufacturer WARNING To disconnect this product from the mains supply disconnect the mains plug from the socket outlet WARNING To avoid risk of electric shock this equipment must only be connected to a supply mains with protective earth WARNING No modification of this equipment is allowed WARNING For EMC details information please contact the NEC local representative e DO NOT OPEN THE MONITOR There are no user serviceable parts inside and opening or removing covers may expose you to dangerous shock hazards or other risks Refer all servicing to qualified service personnel Do not spill any liquids into the cabinet or use your monitor near water Do not insert objects of any kind into the cabinet slots as they may touch dangerous voltage points which can be harmful or fatal or may cause electric shock fire or equipment failure Do not place any heavy objects on the power cord Damage to the cord may cause shock or fire Do not place this product on a sloping or unstable cart stand or table as the monitor may fall causing serious damage to the monitor The power supply cord you use must have been approved by and comply with the safety standards of your country In UK use a BS approved power cord with molded plug having a black 5A fuse installed for use with
12. Papine eie Configuration 1 400 cd m DICOM GSDF Clear Base F GONFIG2 atu dere pati Configuration 2 400 cd m DICOM GSDF 6500K CONEIG 3 nhe ego meiden Configuration 3 300 cd m DICOM GSDF 6500K INPUT SOURCE AUTO SCANNING eese Automatic switching setting of input signal Disable ete eed tefie Does not switch input signal automatically Enable uei ER a ee Switches input signal automatically e DIRECT OSD SETTING MENU pp Direct OSD menu setting ENABLE FUNCTIONS Functions to be enabled Disable li LIL RAI iaia Disables both input signal switching and input port switching Enable Switching Input Source Enables input signal switching only Enable Switching Input Port Enables input port switching only Enable Both Functions Enables both input signal switching and input port switching INPUT SOURCE BUTTON MODE Selects switching mode of input signal Separate Mode ereere Selects separate mode Concurrent Mode sees Selects concurrent mode EXIT irte eeu RUE rues Closes the submenu e MENU SELEOTION esses Selects OSD menu Reference Menu ceeeeeeseeeeteeeeeeeeees Reference menu FEM OOO i ile Full menu BNIE eere ertet Closes the OSD main menu NOTE Items with mark indicate factory default settings
13. U S A Canada EU except U K U K Chinese Japan Plug Shape 4 Voltage 120 230 230 220 100 NOTE This product can only be serviced in the country where it was purchased English 3 Intended Use The MD302C6 color monitor is intended to be used for displaying and viewing of digital images by trained physicians Caution The MD302C6 color display cannot be used for a life support system This device is designed as component of a final system which is in compliance to IEC 60601 1 1 requirements Contraindications None known Safety Precautions This device is designed for exclusive interconnection with IEC 60950 1 certified equipment outside of patient vicinity e Equipment connected to digital interfaces must comply with the respective IEC standards e g IEC 60950 1 for data processing equipment and IEC 60601 1 for medical equipment e This device complies with IEC 60601 1 2 To minimize the interference from other equipment a minimum 0 5 m distance shall be kept form other potential electromagnetic sources such as a Cell Phone To reduce the risk of electric shock make sure that the power cord is unplugged from wall socket To fully disengage the power to the unit please disconnect the power cord from the AC outlet Do not open the back cover No user serviceable parts inside Refer servicing to qualified service personnel The AC outlet shall be readily available and accessible EMC Precaution This prod
14. ie MENU SELECTION Direct OSD setting menu see page 25 Pc EXIT NOTE The OSD menu contents may be selected between Reference menu and Full menu The Reference menu is the factory default 2 Closing the OSD menu Press either or button to move the cursor gt and select Exit Press the MENU button to close the OSD menu NOTE The OSD menu disappears in 15 seconds without closing English 16 OSD menu hierarchy The OSD full menu structure and a brief explanation for each menu item is listed as follows The highlighted items are shown in the Reference Menu The other items are only shown in the Full Menu INFORMATION esee Shows display information PRESENT SIATE n Shows luminance and gamma correction information DICOM CONFORMANCETEST eese DICOM conformance test L START TESTING WO ENDISSE Performs DICOM conformance test CANCELTESTING Cancels DICOM conformance test in execution Cancels test EQ NM Continues test m MOI eet Skips DICOM conformance test SWITCHING EDID i e ae Switches EDID data I 6MP SMP X2 i 1x 3280 x 2048 2x 1640 x 2048 resolutions OMP SMPX2 iia iine eee ee 1x 3072 x 2048 2x 1536 x 2048 resolutions for backward compatibility with original 3MP displays SWITCHING CONFIGURATION eee Switches configuration CONFIG
15. intended location and extending vertically 2 29 m 7 1 2 feet above the floor Mode of operation Continuous operation maximum 16 hours 7 days English 2 A e WARNING TO PREVENT FIRE OR SHOCK HAZARDS DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE ALSO DO NOT USE THIS UNIT S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE PRONGS CAN BE FULLY INSERTED REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL J CAUTION N THIS APPARATUS MUST BE EARTHED BECAUSE OF CLASS EQUIPMENT TO REDUCE THE RISK OF ELECTRIC SHOCK MAKE SURE POWER CORD IS UNPLUGGED FROM WALL SOCKET TO FULLY DISENGAGE THE POWER TO THE UNIT PLEASE DISCONNECT THE POWER CORD FROM THE AC OUTLET DO NOT REMOVE COVER OR BACK COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Power Cord Important Information CAUTION Please use the power cord provided with this display in accordance with the table below If a power cord is not supplied with this equipment please contact your supplier For all other cases please use a power cord that matches the AC voltage of the power outlet and has been approved by and complies with the safety standards of your particular country When you use this Display for medical in North America you should use a North America Hospital Grade power cord Country
16. English 17 Displaying information Various display information can be checked by selecting from the OSD menu 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD menu appears Press either or button to move the cursor gt and select INFORMATION Reference Menu Full Menu XMuzssHazz SeZAUVHHOMINC 4cmcj440un0 odoozma VH rr zZ m WHHOAD rOoOozzo 4 mucaazumne E I P D S S I D M E 2 Information window Press the MENU button and the information submenu appears Model INFORMATION Serial number Maintenance information MODEL MD302C6 Maintenance information 1 SERIAL 2623 1 VSPU Rev 01 MPU Rev A Total operating hours i e ACT TIME 456 H L LAST CAL 123 H EDID 6MP 3MP x2 Operating hours since the last calibration EDID data state NOTE The OSD menu disappears in 15 seconds Displaying present state The present operating state and setting of the display can be checked by selecting from the OSD menu 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD menu appears Press either or button to move the cursor gt and select PRESENT STATE Reference Menu Full Menu M gt E I P D S S I D M E xmezzzemzz ZAAvaaommc jcmcd4douwo O dooszmz VH rr ZZ m wmmmrmoD gt rOOZzO mocaaozm 2 Present state submenu Pr
17. G Press either or button to move the cursor gt and select the preferred setting Input Source Auto Scanning Explanation Disable Disables the automatic scanning function Enable Enables the automatic scanning function Enable is selected by default Press the MENU button to return to the full main menu same as in step 1 NOTE The OSD menu disappears in 15 seconds English 24 Direct OSD setting menu The direct OSD setting menu allows function setting to be enabled or the mode setting to switch an input signal Follow the instructions below By default this function is disabled Functions to be enabled 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor P and select DIRECT OSD SETTING MENU Direct OSD Setting Menu macaoozu OU mdo 4 Ooomo z umooz4 om 242m 24 gt n0 gt CH ENU INF PRE DIC SWI SWI INP DIR MEN EXI ACMCHH4OVO 2 Direct OSD setting menu Press the MENU button and the DIRECT OSD SETTING MENU submenu appears DIRECT OSD SETTING MENU Press either or button to move the cursor gt and select ENABLE FUNCTIONS Direct OSD Setting Menu Explanation ENABLE FUNCTIONS Sets the selected function to be enabled INPUT SOURCE BUTTON MODE Selects switching mode of an input signal EXIT Closes the submenu 3
18. Maintenance This display is factory calibrated for diagnostic imaging in accordance with DICOM Part 14 To ensure constant visual quality over the life of this display the recommended time interval to re calibrate this model is 12 months CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN REDUCE EYE SHOULDER AND NECK FATIGUE CHECK THE FOLLOWING WHEN YOU POSITION THE MONITOR e For optimum performance allow 20 minutes for the display to warm up e Adjust the monitor height so that the top of the screen is at or slightly below eye level Your eyes should look slightly downward when viewing the middle of the screen e Position your monitor no closer than 40 cm 15 75 inches and no further away than 70 cm 27 56 inches from your eyes The optimal distance is 50 cm 19 69 inches e Rest your eyes periodically by focusing on an object at least 6 m 20 feet away Blink often e Position the monitor at a 90 angle to windows and other light sources to minimize glare and reflections Adjust the monitor tilt so that ceiling lights do not reflect on your screen e Position whatever you are looking at most of the time the screen or reference material directly in front of you to minimize turning your head e Avoid displaying fixed patterns on the monitor for long periods of time to avoid image persistence after image effects e Get regular eye checkups Cleaning the LCD Panel When the LCD is dusty please gently wipe with a soft
19. Menu OSD two different display modes are selectable Full pixel mode using the complete area of the LCD panel 1x 3280 x 2048 2x 1640 x 2048 resolutions and QXGA based mode for backward compatibility with original 3MP displays 1x 3280 x 2048 2x 1536 x 2048 resolutions 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor gt and select SWITCHING EDID Full Menu mocaoGzu mado 4 oomo z HuumOdZH Om Zwzm ZzHAp gt n0 gt 007 N N R I w w N I E X A ZIUHONNC ACMCHAOUVUO E I P D S S I D M E English 21 2 Switching EDID sub menu Press the menu button and the SWITCHING EDID submenu appears Press either or button to move the cursor gt and select the preferred mode See below for selectable resolutions Press the MENU button again to store the preferred EDID Switching EDID EDID MP 3MP x2 MP 3MPx2 NOTE The OSD menu disappears in 15 seconds EDID Explanation Full pixel mode using the complete area of the LCD panel The display is used with a resolution of either 3280 x 2048 or 2x 1640 x 2048 3280 x 2048 1640 x 2048 1640 x 2048 Cress 6MP 3MP x2 1 screen display 2 screen display with native resolution with 1640 x 2048 1640 x 2048 1640 x 2048 1640 x 2048 display 1640 x 2048 display QXGA bas
20. N MODE Separate mode allows separate switching of the input source of INPUT 1 and INPUT 2 Press the minus button on the front bezel without displaying the OSD menu and the input source of INPUT 1 is switched The following shows an example of the case when Displayport is selected for the input source of both INPUT 1 and Input 2 and the input source of INPUT 1 is switched to DVI INPUT1 DisplayPort INPUT2 DisplayPort INPUT2 DisplayPort Switching Input Source INPUT1 DVI Switching Input Source DisplayPort DisplayPort DisplayPort English 14 Press the plus button on the front bezel without displaying the OSD menu and the input source of INPUT 2 is switched The following shows an example of the case when Displayport is selected for the input source of both INPUT 1 and Input 2 and the input source of INPUT 2 is switched to DVI INPUT1 DisplayPort INPUT2 DisplayPort INPUT2 DVI INPUT1 DisplayPort Switching Input Source Switching Input Source DisplayPort DisplayPort DisplayPort NOTE Using INPUT 1 and INPUT 2 with different input sources DVI DisplayPort is not recommended for standard applications It may result in slight differences of luminance and color between left and right screen and or a frame skip See page 9 When Concurrent Mode is selected for INPUT SOURCE BU
21. NEC Installation amp Maintenance Guide MD302C6 Disclaimer Windows and MS DOS are trademarks and or registered trademarks of Microsoft Corporation in the United States and or other countries VESA is a trademark of the Video Electronics Standard Association All other products and company names are trademarks of their respective owners English Index Registration Information i English 2 Intended Se uri Ret et eie ec eet lia English 4 Recommended USE e 2 4 pa tetti eb n sedata te ite Rea English 5 Contents rc tali English 7 Connecting the Cables pp English 8 When using a USB h b atalanta lesa ede e rete d English 10 CODIFOIS i1 dott loi Nile Als eae A Le Im pl ny in Aree English 11 Changing signal inputs 3 English 13 Display information d conectan ee teg ree e Hanh aria de tese va poe Pe a nee e English 16 OSD menu hierarchy acte lunigiana illa English 17 Displaying Information iecore re cab ala English 18 Displaying present state L i English 18 Performing a DICOM conformance test iii English 19 Switching the OSD menu iii English 21 Switching between different EDID Content pp English 21 Changing Configurations nennen enne nnne nennen nnns enne n nnne nnns een nnne English 23 Automatic input source detection nna English 24 Direct OSD s tting Menus siete e eet et t tite fuste atte E
22. NPUT 1 INPUT 2 and Input 1 Input 2 This function is available only when ENABLE FUNCTIONS setting of the direct OSD menu setting is set to Enable Switching Input Source or Enable Both Functions see page 26 Press and hold this button to show OSD setting menus With the OSD screen displayed press this button to select and set OSD items LCD Luminance Sensor Caution Do not touch the LCD luminance sensor It may cause the set luminance level to change and or the LCD to fail LED Status Indicator No LED Power Mode 1 Off Off Power off 2 Off On Normal Luminance stabilized 3 Green On Luminance stabilizer on 4 Blinking green On Calibrating 5 Orange On Power management on 6 Blinking orange On Advanced power management on 7 Red blinking red On Error Contact NEC technical support Ambient Light Sensor English 11 English AC Inlet Connect the supplied Power cord 9 Main power switch Main power supply switch INPUT1 of DisplayPort 1 Digital video signal input port Connect the supplied DisplayPort cable INPUTI of DVI 1 Digital video signal input port Connect the supplied DVI cable 2 INPUT of DisplayPort 2 Digital video signal input port Connect the supplied DisplayPort cable 3 INPUT of DVI 2 Digital video signal input port Connect the supplied DVI cable USB upstream port When connecting an USB device to USB downstream port connect one en
23. TTON MODE Concurrent Mode allows simultaneous switching of the input source of INPUT 1 and INPUT 2 Press either the plus or the minus button on the front bezel of the display without displaying the OSD menu The input source of INPUT 1 and INPUT 2 will be switched simultaneously INPUT1 DisplayPort INPUT1 DVI INPUT2 DisplayPort INPUT2 DVI Switching Input Source Switching Input Source DisplayPort DisplayPort English 15 Display information Press the appropriate button located on the front bezel of the display to see display information or change settings 1 Displaying the OSD menu Press and hold the MENU button for 2 seconds The following OSD menu appears See the following pages for all display information items Reference Menu Information see page 18 Present state see page 18 M DICOM conformance test see page 19 Menu selection see page 21 Exit Information see page 18 Full Menu Present state see page 18 Menu selection see page 21 Exit DICOM conformance test see page 19 MENU m 7 INFORMATION Switching EDID see page 21 ae PRESENT STATE reDICOM CONFORMANCE TEST LLL L3 SWITCHING EDID Switching configuration see page 23 i e SWITCHING CONFIGURATION M INPUT_SOURCE AUTO SCANNING are DIRECT OSD SETTING MENU Input source auto scanning see page 24
24. UT1 DVI INPUT2 DisplayPort Switching Input Port English 13 The following shows an example of the case when the resolution of QXGA 1536 x 2048 is selected for both INPUT1 and INPUT 2 By pressing the MENU button and switching a port both screens are active when INPUT 1 INPUT 2 is selected 1536 x 2048 1536 x 2048 1536 x 2048 1536 x 2048 INPUT 1 INPUT 2 INPUT 1 INPUT 2 The following shows an example of the case when the resolution of 3072 x 2048 is selected for INPUT 1 and QXGA 1536 x 2048 is selected for INPUT 2 By pressing the MENU button and switching a port only the screen related to INPUT 1 the resolution of 3072 x 2048 is active when INPUT 1 INPUT 2 is selected This combination exceeds the number of pixels of the LCD panel to show both INPUT 1 and INPUT 2 screens 3072 x 2048 1536 x 2048 3072 x 2048 INPUT 1 INPUT 2 INPUT 1 INPUT 2 Input source switching Input source of each input port of INPUT 1 and INPUT 2 can be switched Input port Input Source Input 1 DisplayPort 1 DVI 1 Input 2 DisplayPort 2 DVI 2 This operation is available only when ENABLE FUNCTIONS of the direct OSD menu setting is set to Enable Switching Input Source or Enable Both Functions The procedure to switch input source depends on the INPUT SOURCE BUTTON MODE selected When Separate Mode is selected for INPUT SOURCE BUTTO
25. ating 4 0 1 67 A USB Hub USB Rev 2 0 compliant Self powered USB upstream port x1 USB downstream ports x2 Ambient conditions Temperature Operating 5 35 C Transport Storage 20 60 C Humidity no condensation Operating 20 80 Transport Storage 10 85 Air pressure Operating 700 1060hPa Transport Storage 266 1060hPa Dimensions amp weight Net 695 6 x 486 5 618 2 x 301 6 mm W x H x D approx 17 6 kg 38 8 Ibs 27 4 x 19 2 24 3 x 11 9 inches W xH x D Safety certifications ANSI AAMI ES60601 1 2005 A1 2012 CAN CSA C22 2 No 60601 1 08 FCC B ICES 008 B CE MDD VCCI B FDA510 K 1 billion 109 NOTE Technical specifications are subject to change without notice MD302C6 is intended to be used in rooms with less than 50 to 69 7 Ix ambient light The maximum ambient light level depends on technical QA standards and or national obligations Troubleshooting The display won t turn on The power indicator is off Make sure the display is connected to the power outlet e Check to see if the display is turned on The screen is not lit e Check if cables are connected correctly e Check if the computer is turned on fthe LED indicator is orange the computer may be in energy saving mode Press any key on the keyboard to wake up the computer e The input signal frequency or display resolution may not be appropriate for the display Refer to the computer instruction
26. cable between the first display s USB downstream port and the second display s USB upstream port 3 Repeat step 2 until all displays are connected one after another NOTE Upto 5 sub monitors may be daisy chained English 10 Controls D Power On Off Press and hold the switch to turn on off the display NOTE Wait at least 10 seconds between on off actions MINUS button Without displaying the OSD on the screen press this button to switch the input source of INPUT 1 to DisplayPort 1 or DVI 1 This function is available only when ENABLE FUNCTIONS setting of the direct OSD menu setting is set to Enable Switching Input Source or Enable Both Functions see page 26 With the OSD screen displayed press this button to move the cursor to right left or up down 3 PLUS button Without displaying the OSD on the screen press this button to switch the input source of 2 INPUT 2 to DisplayPort 1 or DVI 2 This function is available only when ENABLE FUNCTIONS setting of the direct OSD menu setting is set to Enable Switching Input Source or Enable Both Functions see page 26 With the OSD screen displayed press this button to move the cursor to right left or up down MENU button MENU Without displaying the OSD on the screen press this button to switch the input port displayed on the screen The input port is switched in the following order I
27. cloth e Please do not rub the LCD panel with hard or coarse material e Please do not apply pressure to the LCD surface e Please do not use OA cleaner as it will cause deterioration or discoloration on the LCD surface e Do not touch a LCD luminance sensor It could cause the set luminance level to change and or the LCD to fail e Do not spray cleaner directly on the panel surface It could run down the panel surface to the space between the luminance sensor and panel and could cause the display to fail or malfunction see page 11 Cleaning the Cabinet e Unplug the power supply cord from the wall outlet e Gently wipe the cabinet with a soft cloth e To clean the cabinet dampen the cloth with a neutral detergent and water wipe the cabinet and follow with a dry cloth NOTE Many plastics are used on the surface of the cabinet DO NOT clean with benzene thinner alkaline detergent alcoholic system detergent glass cleaner wax polish cleaner soap powder or insecticide Do not touch rubber or vinyl to the cabinet for a long time These types of fluids and fabrics can cause the paint to deteriorate crack or peel English 6 Contents Your new NEC monitor box should contain the following 1 2 MD302C6 monitor with tilt swivel height adjust stand Power Cord Video Signal Cable DVI D to DVI D cable x 2 Video Signal Cable DisplayPort to DisplayPort cable x 2 USB Cable Quick Reference Guide Power Cord
28. d of the supplied USB cable to the display s USB upstream port and the other end to an USB 2 0 port of the computer amp USB downstream port x2 An USB device with a maximum current consumption of 500mA per port can be connected to each port Multiple MD302C6 displays connected in a daisy chain can be calibrated in succession by connecting the supplied USB cable between here and the next display s USB upstream port English 12 Changing signal inputs Two methods to switch signal inputs are available input port switching and input source switching Press the appropriate buttons located on the front bezel of the display as follows Input port switching Input port here means a combination of the input sources of DisplayPort and DVI There are two input ports INPUT 1 and INPUT 2 See the following table and figure for the difference between input port and input source Input port Input Source Input 1 DisplayPort 1 DVI 1 Input 2 DisplayPort 2 DVI 2 I INPUT 1 DisplayPort 1 DVI 1 9 INPUT 2 DisplayPort 2 DVI2 Input ports are located on the side of the display Without displaying the OSD on the screen press the MENU button to switch the input port displayed on the screen The input port is switched in the following order INPUT 1 INPUT 2 and Input 1 Input 2 INPUT 1 INPUT2 DisplayPort INP
29. e skip Difference of image display between left and right screens caused by fast movement of a cursor or window or by video display English 9 When using a USB hub This display has a USB 2 0 compliant hub By connecting the supplied USB cable to a USB 2 0 port of the computer or another USB 2 0 hub USB devices can be connected to the display directly With the computer and the display turned on connect the supplied USB cable between the display s USB upstream port and the computer s USB 2 0 downstream port Back of the display Computer IMPORTANT Proper operation of all USB devices is not guaranteed Depending on the computer operating system and or peripheral devices used the device may not work properly The supplied USB cable can also be used for the followings e To calibrate the display e To calibrate multiple displays in succession To calibrate the display Connect the supplied USB cable between one of the display s USB upstream port and the computer s USB 2 0 downstream port Regarding display calibration please refer to the GammaCompMD QA user manual To calibrate multiple displays in succession Up to six displays can be connected one after another in a daisy chain using USB cables 1 Connect the supplied USB cable between the first display s USB upstream port and the computer s USB 2 0 port 2 Connect a USB
30. ed mode for backward compatibility with original 3MP displays The display is used with a resolution of either 3072 x 2048 or 2x 1536 x 2048 3072 x 2048 1536 x 2048 1536 x 2048 cono 6MP 3MPx2 1 screen display 2 screen display with 3072 x 2048 with QXGA db QXGA display QXGA display English 22 Changing configurations The model MD302C6 can save up to three different Luminance Gamma Color Tint configuration settings within the display These settings are selectable by a configuration number which is shown in the PRESENT STATE submenu The following three configuration settings were saved prior to shipping with configuration 1 as the default setting Configuration number Luminance cd m Gamma Maximum Minimum Ambient 1 400 0 8 0 0 DICOM GSDF 2 400 0 8 0 0 DICOM GSDF 3 300 0 8 0 0 DICOM GSDF Configuration switching 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor gt and select SWITCHING CONFIGURATION Switching Configuration M E I R P E D M S E rs C I T D C M E o4 TI zx m vmo roozzo 4 MUCQOZUH NU NFO RES ICO WIT WIT NPU IRE ENU XIT 2 Switching between configurations Press the MENU button and the Switching Configuration submenu appears Switching Configuration
31. ess the MENU button and the present state submenu appears PRESENT STATE Current luminance PRESENT ST V L__e LUMINANCE 409 Ambient light e AMB LIGHT 20 Ix CALIBRATION SETTING Configuration number _ e CONFIG ANE oo LUMINANCE 400 1 GAMMA DICOM GSDF Luminance setting COLOR Clear Base a Gamma setting Color coordinates NOTE The OSD menu disappears in 15 seconds English 18 Performing a DICOM conformance test NOTE NOTE This function is available only when the display has been calibrated to DICOM GSDF Performing a DICOM conformance test ensures DICOM conformance of the display by measuring and checking the display properties The DICOM conformance test is recommended to be performed after 60 minutes of continuous active backlight time of the LCD panel If the test is performed within less than 60 minutes of active backlight time the reported DICOM GDSF error value may be larger because the luminance was not yet stable enough If the power management setting of the computer is set to less than 60 minutes either change the computer s power management setting only for this test or try DSD operation method without actual OSD screen on page 27 DICOM conformance test procedure 1 Checking the gamma setting Follow the instructions Displaying present state on page 18 and make sure that the gamma correction is set to DICOM GSDP PRESENT STATE
32. has been performed under the recommended conditions calibrate the display using an external calibration sensor i e the NEC model MDSVSENSOR3 During calibration with an external sensor the front sensor of the display will be re adjusted as well NOTE The OSD menu disappears in 15 seconds English 20 Switching the OSD menu Different menu contents can be shown for the menu screen by switching between Reference Menu and Full Menu Full Menu allows setting changes Select MENU SELECTION for switching menu contents 1 Displaying the OSD main menu Press and hold the MENU button for 2 seconds The OSD main menu appears Press either or button to move the cursor gt and select MENU SELECTION Reference Menu Full Menu Odoosmz 4 TT Z2 Y xmezzzeszz AZZIIHHOMRC HFHEmeHHOUO E I P D S S I D M E 2 Switching the OSD menu Press the MENU button The MENU SELECTION window appears Press either or button to move the cursor gt and select the preferred OSD main menu Press the MENU button again to store the OSD selected main menu MENU SELECTION Full menu NOTE The OSD menu disappears in 15 seconds Switching between different EDID content EDID stands for Extended Display Identification Data which among other information reports the display s resolution capabilities to the computer s operating system With the Switching EDID function of the Full
33. ible to change settings in the OSD or perform a DICOM conformance test without changing the computer s power management settings Follow the procedures below to show the OSD menus Displaying the OSD main menu 1 While the display is in energy saving mode the LED indicator is orange press and hold MENU for 2 seconds LED indicator CLerj 2 The LED indicator next to the power switch turns to green the display is turned on and is temporarily in the normal operation mode for up to 3 hours At the same time the OSD main menu appears Reference Menu Full Menu x xmezzzemszz ri ZI THHOMNC dcmcd4douvo O4Oo00zmz wi II zZ m uno rOOZZO mocaoozu mado 4 nomo z muumODDH E I P D S S I D M E v 0079 3 The OSD operation without signal input from computer allows the following operations and a DICOM conformance test If Reference Menu was selected as the OSD main menu the items listed below DICOM CONFORMANCE TEST are not shown To perform one of these operations switch the OSD main menu to Full Menu e DICOM conformance test see Performing a DICOM conformance test on page 19 Switching EDID see Switching between different EDID content on page 21 Switching configuration see Changing configurations on page 23 Switching input source see Automatic input source detection on page 24 Direct OSD setting menu see Direct OSD setting menu on page 25 Men
34. ing of your old NEC product The aim of recycling is to gain an environmental benefit by means of re use upgrading reconditioning or reclamation of material Dedicated recycling sites ensure that environmentally harmful components are properly handled and securely disposed To ensure the best recycling of our products NEC DISPLAY SOLUTIONS offers a variety of recycling procedures and gives advice on how to handle the product in an environmentally sensitive way once it has reached the end of its life All required information concerning the disposal of the product and country specific information on recycling facilities can be found on our following websites http www nec display solutions com in Europe http www nec display com in Japan or http www necdisplay com in USA Energy Saving This monitor features an advanced energy saving capability Green then unlit when Normal Operation Approx 173 5 W luminance is stabilized Energy Saving Mode Less than 22 W Off Mode Less than 20 5 W WEEE Mark European Directive 2012 19 EU Within the European Union EU wide legislation as implemented in each Member State requires that waste electrical and electronic products carrying the mark left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your NEC display products please follow the guidance of you
35. nglish 25 OSD operation without signal input from compUuter nene English 27 jereife u c English 28 Troubleshooting rn de rre adi dee dd t aed teen dede EDS English 28 Attaching a wall mount or multi display mounting arm English 29 Manufacturer s Recycling and Energy Informatigom English 31 Symbol Information This symbol warns the userthat uninsulated voltage within the unit may have sufficient magnitude to cause electric shock Therefore it is dangerous to make any kind of contact with any part inside this unit This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included Therefore it should be read carefully in order to avoid any problems Protective earth terminal marked AC Input Main Power On Main Power Off LT e O Authentication sign of Standard Inspection Bureau for U S A oli ASTO ELECTRICAL SHOCK FIRE AND MECHANICAL Complies with ANSI AAMI ES60601 1 2005 A1 201 2 c US HAZARDS ONLY IN ACCORDANCE WITH ANSVAAMI CAN CSA C22 2 No 60601 1 08 ESS AVA CANCSRC222 MEDICAL GENERAL MEDICAL EQUIPMENT E350980 Windows is a registered trademark of Microsoft Corporation NEC is a registered trademark of NEC Corporation ErgoDesign is a registered trademark of NEC Display Solutions Ltd in Austria Benelux Denmark France Germany Italy Norway Spain Sweden U K Adobe is a registered trademark or tradema
36. r local authority or ask the shop where you purchased the product or if applicable follow any agreements made between yourself and NEC m The mark on electrical and electronic products only applies to the current European Union Member States Outside the European Union If you wish to dispose of used electrical and electronic products outside the European Union please contact your local authority So as to comply with the correct disposal method English 31 NEC Display Solutions Ltd 4 28 Mita 1 chome Minato ku Tokyo Japan NEC NEC Display Solutions of America 500 Park Blvd Suite 1100 Itasca Illinois 60143 USA Phone 1 630 467 3000 Fax 1 630 467 3010 NEC Display Solutions Europe GmbH Landshuter Allee 12 14 D 80637 Muenchen Germany Phone 49 0 89 99699 0 Fax 49 0 89 99699 500 Vol 1 1 Edition June 2014
37. rk of Adobe Systems Incorporated in the U S and or other countries All other brands and product names are trademarks or registered trademarks of their respective owners T DisplayPort and DisplayPort Compliance Logo are trademarks owned by the Video Electronics Standards D Association English 1 Registration Information Declaration Declaration of the Authorized Representative Means of Conformity NEC Display Solutions Europe GmbH declares that the product listed is in conformity with the essential requirements and provisions of the Council Directive 93 42 EEC including the amendments of the Council Directive 2007 47 EC and conforms to the applicable clauses of the following standards Device Classification Class I non measuring function Applicable Rules Annex IX Rules 1 4 Section 1 and 1 1 Section 3 Product Name MD302C6 EN 60601 1 30 0 Diagnostic Imaging _ EN 60601 1 2 LCD color monitor EN 61000 3 2 Model Number MD302C6 EN 61000 3 3 UMDNS Code 16 603 NEC Display Solutions Europe GmbH Landshuter Allee 12 14 80637 Muenchen Germany FCC Information 1 Use the attached specified cables with the MD302C6 color monitor so as not to interfere with radio and television reception 1 Please use the supplied power cord or equivalent to ensure FCC compliance 2 Please use the supplied shielded video signal cable Use of other cables and adapters may cause interference with radio and
38. t in slight differences of luminance and color between left and right screen and or a frame skip Using outputs from different display controllers may cause a frame skip even if the outputs are of the same signal type Please also refer to the GammaCompMD QA user manual for correct setup for dual screen operation e Precautions to display two 3MP screens from two computers Figure E This configuration is not recommended as it may cause a frame skip In addition mixed connection of different signal types DVI DisplayPort may result in slight differences of luminance and color between left and right screen depending on the display controller models used in the two computers Note This configuration is not supported by the NEC GammaCompMD QA calibration software Two 3MP screens from Two 3MP screens from 1 computer two computers Figure D Figure E e Precautions to display two 3MP screens or screens with the resolution other than 6MP lt Examples gt XGA screen XGA screen 3MP screen VGA screen XGA screen Some resolutions other than two 3MP screens or one 6MP screen are supported but their display performance is not guaranteed Doing so may result in slight differences of luminance and color between left and right screen or a frame skip Note Mixed resolution configurations are not supported by the NEC GammaCompMD QA calibration software Fram
39. television reception 2 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult your dealer or an experienced radio TV technician for help If necessary the user should contact the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock
40. the monitor so that heat can properly dissipate Do not block ventilated openings or place the monitor near a radiator or other heat sources Do not put anything on top of monitor The power cable connector is the primary means of detaching the system from the power supply The monitor should be installed close to a power outlet which is easily accessible Handle with care when transporting Save packaging for transporting e Do not touch LCD panel surface while transporting mounting and setting Applying pressure on the LCD panel can cause serious damage e Carry the monitor by holding the top and the bottom of the monitor head with both hands e Do not carry holding only the stand CAUTION English 5 Image Persistence Image persistence exists when a residual or ghost image of a previous image remains visible on the screen Unlike with CRT monitors image persistence on LCD monitors is not permanent but constant images being displayed for a long period of time should be avoided To alleviate image persistence turn off the monitor for as long as the previous image was displayed For example if an image was on the monitor for one hour and a residual image remains the monitor should be turned off for one hour to erase the image NOTE As with all personal display devices NEC DISPLAY SOLUTIONS recommends using a moving screen saver at regular intervals whenever the screen is idle or turning off the monitor when not in use
41. this monitor Do not place any objects onto the monitor and do not use the monitor outdoors Do not bend crimp or damage the power cord Do not use monitor in high temperatured humid dusty or oily areas Do not cover vent on monitor Vibration can damage the backlight Do not install the monitor where it will be exposed to continual vibration If the monitor s LCD panel is broken do not come in contact with the liquid crystal and handle with care To prevent damage to the LCD monitor caused by tipping over due to earthquakes or other shocks make sure to install the monitor in a stable location and take measures to prevent falling Please do not touch patient and this medical device at the same time Immediately turn off the power unplug your monitor from the wall outlet and move to a safe location then refer servicing to qualified service personnel under the following conditions If the monitor is used in this condition the monitor may cause fall fire and electric shock If the monitor stand has been cracked or peeled If the monitor has been wobbled If the monitor emanates an unusual odor When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the monitor If the monitor has been exposed to rain or water If the monitor has been dropped or the cabinet is damaged If the monitor does not operate normally by following operating instructions e Allow adequate ventilation around
42. u selection see Switching the OSD menu on page 21 NOTE The display being turned on to the normal operation mode by the operation above is only temporary This mode is left after any of the following conditions are met 1 3 hours have passed 2 The display power has been turned off 3 A DICOM conformance test has been performed English 27 Specifications Monitor Specifications MD302C6 Notes LCD panel color Clear Base LCD 30 0 inch 76 8 cm color TFT Active matrix type normally black Anti glare Pixel pitch H x V 0 197 x 0 197 mm Display area H x V 645 5 x 403 05 mm Pixel H x V 3280 x 2048 Display colors 8 bit 16 77 million out of 68 billion 10 bit 1 07 billion out of 68 billion Backlight LED backlight LCD Optical characteristics typ Viewing angle 170 horizontal vertical contrast ratio 2 10 1 Contrast ratio 1000 1 Viewing angle of 0 horizontal and vertical Luminance DICOM calibrated 400 cd m as factory default Maximum 550 cd m 800 cd m typ as LCD component Input sync signal DVI 1 0 compliant DisplayPort 1 1a compliant Available resolution 640 x 480 800 x 600 1024 x 768 1536 x 2048 at Fv 60Hz 3072 x 2048 at Fv 30Hz 1640 x 2048 at Fv 60Hz 3280 x 2048 at Fv 30Hz Input connectors DVI 24 pin connector x2 DisplayPort connector x2 Power Supply AC 100 240 V 50 60 Hz Current R
43. uct requires special EMC precautions and needs to be installed and used according to the following information Use the specified cable Using other cables could increase emission or decrease immunity Do not place any RF communication equipment in the vicinity of this product It could affect the performance of the product Any additional equipment connected to this product needs to comply with the requirements of IEC 60601 1 2 North America Customers Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade These signal input ports need to be connected properly and any unused signal input ports shall not be accessible for the patient to contact in the patient area after the LCD is integrated into a medical system Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner European Customers Unpacking Installation and calibration of this display should only be done by authorized and trained personnel Any installation done by a non authorized person is done under his own risk and we accept no responsibility in any device malfunctioning To secure full functionality of this display only NEC approved display controller models for connection with the final system must be used Medical Imaging MD302C6 is designed for 3280 x 2048 medical imaging English 4 Recommended use Safety Precautions and Maintenance FOR

Download Pdf Manuals