image

Contents

1. 200 240V fo A SNMP HTTP Network Slot Allow users to remotely control and monitor the ATS PDU when installed with CyberPower s Remote Management Card Serial Port RJ45 modular port Use serial port to connect with PC and execute local control of the ATS PDU Source Indicator Indicates Source A or B is in use When both sources are normal selected source shows constant green LED while another source shows blinking green LED Output Indicator Indicates load condition of the ATS PDU Multifunction LCD Readout Display various ATS PDU information such as power and load conditions Select Button Use to control the LCD display and toggle through the available informational options Enter Button Use to choose selected items enter to next level menu or return to previous menu AC Inlet AC Power Cord Use to connect ATS PDU to utility power or UPS Ground Stud Use to ground the ATS PDU J AC Output Receptacles Provides power distribution for connected equipment Outlet Indicator switched series only When the LED is on the outlet is providing power to connected equipment Technical Specifications Switched Series Metered Series Model Name PDUI5SW10ATNET PDUISSWHVIECI2ATNET
2. NEMA Type o Source A Bank1 20A o reeeo a mr ar Hr ar ate Br ar ae mM 400 120v O 1 O2 O3 O4 O5 O6 O7 O8 L5 30R Sourcen V ped Bank2 20A S 2D ap ah ah ah aH aH ah a aa 3r ET ar ar 37 ar ae Q9 10 on O12 O13 O14 O15 O16 IEC Type o L J00 POl i HEA ES CO 5 em Le Le 6 Le HE mm gt m 6 200 240V Gi O2 O3 OF O5 O6 O7 oO 8 O9 L6 30R Source B H Va Ve Ve Ve i gt Bank2 20A S J a 1O OPCS OOP el x O10 On O12 Om Om O75 O16 Ov Ow Q oO A SNMP HTTP Network Slot Allow users to remotely control and monitor the ATS PDU when installed with CyberPower s Remote Management Card B Serial Port RJ45 modular port Use serial port to connect with PC and execute local control of the ATS PDU C Source Indicator Indicates Source A or B is in use When both sources are normal selected source shows constant green LED while another source shows blinking green LED D Output Indicator Indicates load condition of the ATS PDU E Multifunction LCD Readout Display various ATS PDU information such as power and load conditions F Select Button Use to control the LCD display and toggle through the available informational options G Enter Button Use to choose selected items enter to next level menu or return to previous menu H AC Inlet AC Power Cord Use to connect ATS PDU to utility power or UPS AC
3. Ensure that the power cord plug and socket are in good condition A To prevent the risk of fire or electrocution this ATS PDU should be installed in a CAUTIONI temperature and humidity controlled indoor area free of conductive contaminants Do Z 3 not install this ATS PDU where excessive moisture or heat is present Before using please check to ensure the package contains all the items shown below If there are missing parts please contact your local CyberPower sales team for Check technical support 2014 CyberPower Systems Inc All rights reserved Product Contents For 1U Series 24 M4x8 Bracket Mounting Screws Includes eight spares FP rrF 6 M5x12 Rack Mounting Screws 6 Washers Includes two spares for each Cord Retention Tray wy y 2 M3x4 Cord Retention Tray Mounting Screws Cable Ties Qty 18 for 10 outlets 21 for 12 outlets RJ45 DB9 Serial Port Connection Cable bs Jumper Switched type only Registration Card User Manual Registration Card CD Below items only provided with IEC type ATS PDU IEC Socket Power Cord Stand 2 for 10 outlets 3 for 12 outlets S ry amp M3x4 Screws 15 for 10 outlets 22 for 12 outlets EQD S Power Cord 10 feet IEC 320 C13 C14 x 2 PDULSSWHVIEC12ATNET PDU15MHVIEC12AT Model Only Power Cord Retention Cable Clip 18 for 10 outlets 21 for 12 outlets Cable Tie 18 for 10 o
4. cyber For further information and configuration via Hyper Terminal see Appendix A Hyper Terminal 10 2014 CyberPower Systems Inc All rights reserved Installation Guide Power Cord Retention Clip Installation For IEC type ATS PDU Input Power Cord Retention Cable Clip Installation Step 1 Remove the screw next to the inlet Step 2 Attach the Cable Tie on the ATS PDU and secure it with the screw removed in the previous step Step 3 Place a Power Cord Retention Cable Clip on the power cord Align and insert the Cable Tie into the Cable Clip as shown in the figure below Step 4 Push the Power Cord Retention Cable Clip until it touches the plug and fasten the Retention Cable Clip like the figure below 11 2014 CyberPower Systems Inc All rights reserved Installation Guide Power Cord Retention Clip Installation Step 1 Remove the screws next to the outlet where IEC Socket Power Cord Stand will be installed Step 2 Attach the IEC Socket Power Cord Stand on the ATS PDU and secure it with the screws removed in the previous step Step 3 Attach Cable Tie on the IEC Socket Power Cord Stand and secure it with the provided screw Step 4 Place a Power Cord Retention Cable Clip on the power cord Align and Insert the Cable Tie into the Cable Clip as shown in the figure below Step 5 Push the Power Cord Retention Cable Clip until it touches the plug and fasten the Retention Cable Cli
5. Output Receptacles Provides power distribution for connected equipment J Outlet Indicator switched series only When the LED is on the outlet is providing power to connected equipment K Circuit Breaker Provides output overload protection L Ground Stud Use to ground the ATS PDU Technical Specifications Switched Series Metered Series Model Name PDU30SWT17ATNET PDUSOSWHVT1I9ATNET PDU30MT17AT PDU30MHVT19AT Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 24A Plug Type 2 NEMA L5 30P 2 NEMA L6 30P 2 NEMA L5 30P 2 NEMA L6 30P Power Cord Type SR 10 AWG Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V C13 12A C13 12A Derated Output Current ena C19 16A ET C19 16A i L6 30R 24A i L6 30R 24A ee Current 20A Bank Number 2 ee us nemaszon Gece WEINEMASOR Gieco 1 NEMA L6 30R 1 NEMA L6 30R Outlet Number 17 19 17 19 Circuit Breaker Yes Typical 8 12ms Transfer Hime 16ms max 60Hz 18ms max 50Hz Management and Communications Multifunction LCD Readout Voltage Frequency Load Current HW FW Version Network Information Software PowerPanel Business Edition SNMP HTTP Capable Yes with RMCARD203 ee e Connectivity RJ45 Serial Port Sensor Capable Optional Physical Dimension W x H x D 17 05 x 3 5 x 9 3 433m
6. PDU15M10AT PDUISMHVIEC12AT Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 12A 12A UL 10A CE 12A 12A UL 10A CE Plug Type 2 NEMA 5 15P 2 IEC 320 C14 2 NEMA 5 15P 2 IEC 320 C14 Power Cord Type SR 14 AWG Socket SR 14 AWG Socket Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 12A 12A UL 10A CE 12A 12A UL 10A CE Outlet Type NEMA 5 15R IEC 320 C13 NEMA 5 15R IEC 320 C13 Outlet Number 10 12 10 12 Transfer Time Typical 8 12ms 16ms max 60Hz 18ms max 50Hz Management and Communications Multifunction LCD Readout Voltage Frequency Load Current HW FW Version Network Information Software PowerPanel Business Edition SNMP HTTP Capable Yes with RMCARD203 Yes with optional RMCARD202 203 Connectivity RJ45 Serial Port Sensor Capable Physical Optional Dimension W x Hx D 17 05 x 1 75 x 9 3 433mm x 44mm x 236mm Environmental Humidity 0 to 95 Non condensing Altitude 13100 ft 4000 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals Certifications UL 60950 1 FCC Class A UL 60950 1 CE FCC Class A UL 60950 1 FCC Class A UL 60950 1 CE FCC Class A All specifications are subject to change without notice 4 2014 CyberPower Systems Inc All rights reserved
7. Product Features Front Rear Panel Description 1U 20A series Q 00O Q Expansion Port Provides SNMP Card Communication ea oF Serial Port ZA NEMA Type Source A Source B m Z e L 50 60 Hz q Q q qd qd O O7 et ee oe ep fae ge ep ae ae oC o 0 IEC Type WwW WwW i i WwW WwW WwW i WwW i WwW i WwW WwW Q O N O w O gt O a O o O N O O o O Source B 200 240V O 50 60 Hz O SourceA e A SNMP HTTP Network Slot Allow users to remotely control and monitor the ATS PDU when installed with CyberPower s Remote Management Card B Serial Port RJ45 modular port Use serial port to connect with PC and execute local control of the ATS PDU C Source Indicator Indicates Source A or B is in use When both sources are normal selected source shows constant green LED while another source shows blinking green LED D Output Indicator Indicates load condition of the ATS PDU E Multifunction LCD Readout Display various ATS PDU information such as power and load conditions F Select Button Use to control the LCD display and toggle thr
8. fhe Program CyberPoserSpalend Inc HSA Services Login Hime RMCARD There are two files to update in order to upgrade the firmware cpssnmpfw_XXX bin cpssnmpdata_XXX bin Note that the XXX is not part of the file name but is where the version number in the filename is given Use the following steps to upgrade the firmware 1 Download the latest firmware from cpsww com Extract the file to C Open a command prompt window and navigate to C Login to the Remote Management Card with FTP command type ftp after entering ftp mode ftp gt will display in the command prompt as shown below instead of C ftp gt open To current IP of the RMCARD port for example To 192 168 22 126 21 21 is the default ftp port for the RMCARD Input USER NAME and PASSWORD same as the administrator account in Web interface default cyber cyber 5 Upload the cpssnmpfw_XXx bin type ftp gt bin ftp gt put cossnmpfw _XXX bin 6 Upgrade complete type ftp gt quit7 The system will reboot after you type quit This reboot will take approx 30 seconds 8 Login to the FTP again ftp ftp gt open To current IP of the RMCARD port for example To 192 168 22 126 21 21 is the default ftp port for theRMCARD Input USER NAME and PASSWORD 9 Upload cpssnmpdata _XXX bin ftp gt bin ftp gt put cossnmpdata _XXX bin 10 Upgrade complete type ftp
9. gt quit 11 The system will reboot after you type quit PWN Troubleshooting Problem Possible Cause Solution ATS PDU outlets do 1 Breaker tripped Reset Breaker check the plug to not provide powerto 2 Power cord is not insure its connected correctly If connected equipment properly plugged in the problem remains contact technical support Amperage displayed The load indicator shows red on LCD Display when overload Reduce the load exceeds the units Overload on the ATS PDU until the overload capability is gone If the problem remains contact technical support 1 Sustained overload Reset Breaker Circuit breakers have 2 Excessive ambient or If the problem remains contact tripped internal temperatures technical support 3 Faulty breaker 19 2014 CyberPower Systems Inc All rights reserved Conformance Approvals FCC Warning WARNING This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user w
10. is Enabled 3 Make sure the network connection is ready and power on the ATS PDU 4 The ATS PDU will obtain an IP address from the DHCP server automatically Option 3 Address Resolution Protocol ARP Command 1 Obtain the MAC address from the sticker on the ATS PDU 2 Open a command prompt as an administrator and type the following arp s available IP address MAC address of ATS Example arp s 192 168 20 240 00 0C 15 00 00 01 IP Address MAC Address 3 Use the Ping command to assign a size of 123 bytes to the IP Type in ping 192 168 20 240 123 then press Enter If the replies are received your computer can communicate with the IP address Option 4 Hyper Terminal or Terminal Emulator In order for Hyper Terminal to interface with the ATS PDU the PC server must be connected directly to the ATS PDU via the serial port 1 Use the included RJ45 DB9 serial port connection cable attach one end to the serial port on the front of the ATS PDU and the other end to the PC server 2 Open the Hyper Terminal software on your PC and select a name and icon for the connection 3 Setup the COM port settings using the following values Bits per second 38400 Data bits 8 Parity None Stop bits 1 Flow control None 4 Press Enter to enter the Authentication menu 5 Enter the user name and password of the ATS PDU device at the Authentication menu Note The default username is cyber and the default password is
11. on Hyperterminal ACI COPYRIGHT 2013 CyborPoworSyeteas TAP Amplicationm Wersien 0 0 11 By ATS Dovolopasni Tosa zerenmeree mnene Kain Henu lt 9 lt 9 lt 929222222 2 Goanload Fireware To the ATS Hlerapeocesser 1 Download Fireware To the LOD Wicroprocessor Execute The Program LAP Apelitalion Version 0 8 1 be ATS Deoolopeent Toa fewnlond Firesare To the ATS Bicreprocesace Domlani Firesare To the LOD Aicroproecester Execuhe The Propan SRSRSSSEESSESESEESEEESEEEEE Wailing fer the file to be gent press a to abort 6 Select Transfer gt Send File test HyperTerminal File Edit wiew Call Transfer Help ael 3 j oSendFile Receive File Capture Text Send Text File Capture to Printer 7 Note that the Ymodem protocol and file C cpsatsmafw_xxx bin are selected in Hyperterminal 16 2014 CyberPower Systems Inc All rights reserved Firmware Upgrade 8 The download progress window will open after you click the Send button Yroedens fle gene Poe tesi Packet 0 Emerchecking CRC Flee SK Retiex BO Totahreties B Refia Lateno Uneguened respone fo eee Ekpe O Remaning a cca pate 9 After uploading the binary file Hyperterminal will show as below aliaj j ala cia g Prograssing Coaplotod Successfully Kame come lsmafe_xem bin Siz
12. quick and easy at www CPSww com under Support CyberPower International Feel free to contact our Tech Support department with installation troubleshooting or general product questions CyberPower Systems Inc Web www cpsww com CyberPower Systems USA Inc Phone 952 403 9500 Toll free 877 297 6937 Email tech cpsww com Web www CPSww com Add 4241 12th Avenue E Suite 400 Shakopee MN 55379 Hours of Operation Monday Friday 8 00 AM 5 00 PM CST Limited Warranty Read the following terms and conditions carefully before using the CyberPower ATS PDU series By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who Is Providing This Warranty CyberPower Systems Inc provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions What Is The Period of Coverage CyberPower provides a 3 Year limited warranty to the original purchaser who owns the Product 20 2014 CyberPower Systems Inc All rights reserved Customer Service amp Warranty Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 You can u
13. the Cord Retention Tray to the ATS PDU with the 8 Cord Retention Tray Mounting Screws provided Use the Cable Ties provided to fasten each power cord to the Cord Retention Tray 2014 CyberPower Systems Inc All rights reserved Installation Guide Replacing the LCD Panel Step 1 Use a slotted screwdriver to gently lift out the LCD panel Electrical Installation Step 1 Receptacle evaluation Ensure that the plug type of your ATS PDU unit matches the receptacles that you are using The ATS PDU must be plugged into a three wire grounded utility receptacle or a UPS that is connected to a grounded utility receptacle The utility receptacle must also be connected to an appropriate branch circuit main with fuse or circuit breaker protection Connection to any other type of receptacle may result in an electrocution hazard CAUTION a N Step 2 Plug the ATS PDU into the utility receptacle and or UPS Step 3 Attach equipment It is extremely important not to exceed the ATS PDU s maximum current load as outlined in the Specifications section In order to determine total load use the LCD diaplay on the front of the ATS PDU to monitor the load being attached 2014 CyberPower Systems Inc All rights reserved Installation Guide Network Installation Performed when a Remote Management Card is installed Step 1 Attach the LAN Cable Using a CAT5 RJ45 cable attach one end
14. to the Ethernet port on the RMCard and the other end to a network port Step 2 Establish the ATS PDU IP address Assigning an IP address to the CyberPower ATS PDU requires the user to have an available IP address that is valid on the respective network If an available IP address is unknown contact the network administrator to obtain one The default IP is 192 168 20 177 and the default for the DHCP function is on There are multiple methods for setting up the IP address of the ATS PDU Please follow the instructions below for the method that is appropriate for your application Please make sure the ATS PDU is powered on during this process Option 1 recommended Power Device Network Utility 1 Use the included Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start gt Power Device Network Utility 3 Highlight the ATS PDU device from the list and select Edit and Setup device gt Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your network settings 5 Enter the user name and password of the ATS PDU device at the Authentication menu Note The default username is cyber and the default password is cyber For further information and installation instructions see Appendix B Option 2 DHCP Server 1 Ask your administrator if there is DHCP server on the LAN 2 Make sure the DHCP
15. typing the number of the menu option and pressing the Enter key Note The session will timeout and logout after 3 minutes of inactivity Menu options are shown below Main Menu Utility Configuration Outlet Manager Switched Series Only Load Configuration Network Settings System Configuration Account Settings Configure System to Default Logout CON DU BWN PB Utility Configuration Preferred Source A Sensitivity High Voltage Range Medium Frequency Deviation 1 Hz Nominal Voltage 230 V Wide Voltage Range 30 V Medium Voltage Range 23 V Narrow Voltage Range 16 V Set Load Restriction WO CON OU BPWN BP Outlet Manager 1 Outlet Control 2 Outlet Configuration Load Configuration 1 Device Threshold Configuration 2 Bank 1 Threshold Configuration 3 Bank 2 Threshold Configuration 4 Bank 3 Threshold Configuration Network Setting Physical MAC Address 00 0C 15 00 00 01 1 System IP 192 168 20 240 2 Subnet Mask 255 255 255 0 3 Default Gateway 192 168 20 254 4 DHCP Enabled 5 Http Port 80 6 Http Access Enabled System Configuration 1 Name PDULSSW10ATNET 2 Location Server Room 3 Contact Administrator Account Setting 1 Administrator Configure System to Default Sure to Configure System to Default 1 Reset ATS 2 Reset ATS TCP IP Settings Reserved 22 2014 CyberPower Systems Inc All rights reserved Appendix B
16. IROSENSOR as shown in figures below When the ATS PDU connected correctly to the ENVIROSENSOR users can see the temperature and humidity data with the Web Interface For further information regarding ENVIROSENSOR configuration please refer to the Software Installation CD Device Reset e To reset all the settings to default locally use Reset function in the LCD display e To reset all the settings to default remotely log in Web interface enter the Reset page and apply the function Unattended Automatic Shutdown PowerPanel Business Edition software automatically intitiates a graceful shutdown on the operating system in an orderly fashion PowerPanel must be installed on every computer or server for which the shut down is to take place The computer will receive an SNMP message from the ATS PDU and will perform the shut down according to the instructions provided including shut downs at exact time and dates Follow the directions below for setting up Unattended Automatic Shutdown Step 1 PC Configuration 1 Install PowerPanel Business Edition Client on every computer server that will be part of the shut down process Follow the instructions in the PowerPanel Business Edition Client user manual 2 Configure the settings in PowerPanel Business Edition Client See the PowerPanel Business Edition Client User Manual for additional help Step 2 ATS PDU Configuration Verify that the IP address of all computers that will be part o
17. Power Device Network Utility Overview The CyberPower Power Device Network Utility is an easy to use interface which is used for establishing IP addresses on CyberPower ATS PDUs Installation Step 1 Insert the CD labeled Software Installation CD into the CD DVD drive Step 2 Select Power Device Network Utility from the installation menu Shown in Figure 1 CyberPower The PDU Power Distribution Uni allows administrators an gagy way to control AG power for varous commected devices via network Inztalling the below software helps users io sirengihen the POU functions Power Device Network Utility The Power Dewse Network Ubhly gues users an 2ety bouge fleriace to esiabksh SNMP and nehwvork setings on the POU Install Power Device Nehvork lity PowerPanel Business Edition PowerPanel Business Edition provides the capability of unatiended automatic shytdoen of connected Pa servers to the POU gial PowerP ane Bunnes Edition Regd listalaten Gude paa ihia Figure 1 Installation Menu Step 3 Select Next in the software wizard Step 4 Choose an installation directory and user settings Select Next Shown in Figure 2 i Power Device Network Utility Select Installation Folder The installer will install Power Device Network Utility to the following folder To install in this folder click Nest To install to a different folder enter it below or click Browse Folder C Program Files CyberPower Po
18. Reliability Quality Value CyberPower User Manual Automatic Transfer Switch Table of Contents OT i circa eet l Model Lst eerror ennea a e EA NEA A 1 Product Contents cv spcs ss esesessvsscsseetssteeestesteseateatsteeteteesseass 2 For 1U Series asrianiasr EE AEE R A 2 For 2U Seri eS ormie a ps cusnaouppenoones 3 Product FeaturesS eeeeieseeeieeserisssrresssrresssrreessrireserreesesree 4 Front Rear Panel Description 1U 15A series 4 Technical SOSCINCALIONS sumissnssnsmasisnnaiarnraisiaas 4 Front Rear Panel Description 1U 20A series 5 Technical Specificati ns acacusccnmmmmmnannnemannenaumh 5 Front Rear Panel Description 2U series 6 Technical SOSCINCARIONS uacntcewcc ae cneteinnecnenens 6 Installation Guide c cccccsscsccscsecsecstestsessesetssstsetsestsstsessesteees 7 For 1U Seres nienn a 7 For 2U Series ernes aana EA ATEEN 8 Replacing LCD Panel ssssssssssssrsessreessressrressrresssresssressrreesrressrreesrrress 9 Electrical Installation eeeeeeeiseesisessirsrsirssirisirisirirsirrrserrsn 9 Network Installation eesesseseesssisesessisisisisrsisisisrsrsrrirrrsrsrerrersrsreens 10 Performed when Remote Management Card is installed cccccceeee 10 Power Cord Retention Clip Installation For IEC type ATS 11 Input Power Cord Retention Cable Clip Installation 11 Power Cord Retention Clip Installation ccc 12 Removing the Power Cord R
19. e If the ATS PDU does not appear on the list click the Refresh button to rescan the network If it still does not appear ensure that the ATS PDU is turned on and is installed correctly Pressing Stop will cancel the scan refresh process Note If your computer has a software firewall installed you may see a Windows Security Alert message Shown in Figure 5 In Windows XP SP2 the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Windows Security Alert To help protect your computer Windows Firewall has blocked some features of this program ag Hams Power Device Network Utility Publisher Unknown Windows Firewall has blocked this program from accepting connections from the Intemet or a network If you recognize the program or trust the publisher you can lt iblock nA 20 UMC a Doorn it When shouk LL Figure 5 Windows Security Alert Step 2 Assign a valid IP Address to the ATS PDU With the appropriate device selected from the Equipment List open the Network Settings menu shown in Figure 6 Tools gt Device Setup In the Device Network Setting Menu enter a valid IP address subnet mask and gateway address to setup the ATS device Device Network Settings Device MAC Address 00 0C 15 40 08 A9 Using DHCP OvYes No IP Address 192 168 24 20 Subnet Mask 255 255 255 0 Gateway 192 168 24 254 Fig
20. e Ih CyberPower Syctteat Ing RRS Service Name Login i a RE Fate piae F LCD Update the following file to upgrade the firmware cpsatslafw_xxx bin Note that the XXX is not part of the file name but is where the version number in the filename is given Use the following steps to upgrade the firmware 1 Download the latest firmware from cpsww com 2 Extract the file to C 3 Open Hyper Terminal to connect the ATS PDU and use the command NEW CyberPoserSyetoms Inc R3297 Service Login Hasc HiH 0 COPYRIGHT 2013 CuborPonerSyatoas I feolication Version 0 0 1 fv ATS Developaent Teas PPP PEPE EEEEEE EEE EERE EERE RRR ERR RRR RRR RR ERR Gomnlood Firesare To the ATS Hicroprocessor Domlosd Firmare To the LOD KLoroproceseor Execute Whe Program J Pro TiC TTT Titra CC COPYRIGHT 2013 CyberPowerSystems IAP Application Version 0 0 1 By LCD Development Tean Main Nenu Dosalcad Fireware To the LCD Microprocessor Execute The Progras 2014 CyberPower Systems Inc All rights reserved 17 Firmware Upgrade 6 Press 1 CC COPYRIGHT 2013 CyberPowerSysteas IAP Application Versice 0 0 1 By LCD Developecnt Teas Maile Weny Dosnload Fireware To the LOD Nicroprocessor l GROES tne TEORIE ree 2 l r Waiting for the file to be sent press a to abort ccecce lt oon iwe were 7 Select Trans
21. e Product such as laser printers appliances aquariums medical or life support devices etc What Are The Limitations 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been used at all times within the limitations on the Product s VA capacity 5 The sole and exclusive remedies of the Initial Customer are those provided by this Warranty 2014 CyberPower Systems Inc All rights reserved 21 Appendix A Hyper Terminal Hyper Terminal software can be used for basic ATS PDU configuration It utilizes a text based interface and menu system Navigation through the interface is done by
22. er cyber SNMP The CyberPower ATS PDU supports SNMPv1 and SNMPv3 Remote Management protocols Download the CyberPower MIB file and add it to a SNMP supporting management software Default read write community is public privated for SNMPv1 SNMPv3 provides a higher security level than SNMPv1 by encrypting the transmitted packet Configure the settings of the SNMPv1 SNMPv3 on Web Interface 13 2014 CyberPower Systems Inc All rights reserved Operation Local Management LCD Operation The LCD display provides instant information such as source condition voltage and current for the ATS PDU In addition users can use the interface to configure each PDU parameters and control each outlet on the switched ATS PDU A Scroll Mode The ATS PDU information will display in following order automatically when Scroll Mode On is configured Source A information Source B information Device Load Bank 1 Current 2U series Bank 2 Current 2U series Bank 3 Current 2U series Environment Status Displays when the ENVIROSENSOR is connected B Main Menu Map Hardware Version Firmware Version About Network Information Serial Number Preferred Source A B None Nominal Voltage Voltage Range Source Configuration Freq Deviation Sensitivity Overload Th
23. etention Clip sseee 13 Operation E eters ne tages PA E cana AAE E na E ores 13 Remoting ViahaseMenlanciinnrimumuwinnammmenunnaumnan 13 NAV 1D EEE 13 Telnet and SSH ccccccccscsessssssesesescscssesssescscesesesescstesseseseecscsseseseeceee 13 ON sop EE 13 Local MAMAS CIS ccm cea cecreeretercenncnnsnteranien enced 14 PCD ODEO Merete E T chmenoeeen toasts 14 LED Indicators peeremeneeene meter nearer tee eennner ere cer reenter aoe 14 Environmental Monitoring Optional cccsecseeen 15 DEVICE RESCE E 15 Unattended Automatic Shutdown s s s 15 Firmware Upgrade A ese 16 ATS PDU nornin 16 EED E E A T T E A T E A A 17 RVICARD nonnai saree eeeesaatoen 19 Trou bleshooting CEEE E P EE A 19 Conformance Approvals sssr 20 Customer Service amp Warranty ensnieneganns 20 Appendix A Hyper Terminal ee 22 Appendix B Power Device Network Utility 23 Overview CyberPower Automatic Transfer Switches PDUs with dual input for power provide redundant and increased reliability for critical devices with a single power plug Users can define the preferred input power source When a selected source is unstable or unavailable the ATS PDU will switch to the second power source to constantly provide power to connected devices The entire ATS PDU series are designed with LED and LCD interfaces for users to easily observe power status and device load On site power management is accomplished as users can configure p
24. f the shut down process are included in the Client List of the web interface For additional information please refer to the user manual in the Software Installation CD Step 3 Notification Notifying the computers of potential outlet shutdowns can be accomplished using the following methods e Outlets Control Menu Performing the task of turning off or rebooting outlets e Scheduling Menu Setting the application to perform the task of turning off or rebooting outlets The notification will occur prior to the scheduled date time e Outlet Overload In the event of ATS PDU overload notification will be sent prior to the ATS PDU shutting down 2014 CyberPower Systems Inc All rights reserved l gt Firmware Upgrade By upgrading the Firmware you can obtain new features updates and improvements to existing functionality ATS PDU Update the following file to upgrade the firmware cpsatsmafw_xxx bin Note that the XXX is not part of the file name but is where the version number in the filename is given Use the following steps to upgrade the firmware 1 Download the latest firmware from cpsww com 2 Extract the file to C 3 Open Hyper Terminal to connect the ATS PDU and use the command NEW ates vce Ferm eee De qa p sa poe iye Dis 213 ca s CyberPowerSystems Inc RS232 Service Login Name ANPU Competed da N Andama iiaeie pau Mi MN ewe Pet ote 4 The ATS PDU will reboot and show main menu
25. fer gt Send File test HyperTerminal File Edit view Call Transfer Help Send File H r Receive File Capture Text Send Text File Capture to Printer 8 Note that the Ymodem protocol and file C cpsatslafw_xxx bin are selected in Hyperterminal CEE File Folder C temp Filename Cepat ex bin Browse Protocot _ S 9 The download progress window will open after you click the Send button frien he send for best Sending Cipa ea Pocket 0 Emorchecking EAC Flame OR Ree Bo Tadei Fle a7 Leteo Uegen repor w D a O Eipre O Remain Tea E ace 10 After uploading the binary file Hyperterminal will be shown as below Proorassimy Completed Successful ly Meme ose ts lats_som bin Size Im Gybr omer Syanie le ESZA Service Login lame You can see if the firmware upgrade is successful by checking the CyberPower System Firmware Version after login 18 2014 CyberPower Systems Inc All rights reserved Firmware Upgrade Note 1 Please do not turn the ATS PDU off and ensure the quality of selected source power when processing firmware upgrade The ATS PDU will not perform the ATS function when upgrading firmware 2 Press 3 to exit the main menu of firmware upgrade By AMS Gevelonent Team Main Berg 00tsssssssnsesnennn Dami Firemare lo ihe ATS Aioreprececcer Downilosd Firmware To the LUD Microprocessor Emnrule
26. ill be required to correct the interference at his own expense Any special accessories needed for compliance must be specified in the instruction This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice 1 An unshielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception It is essential that only the supplied power cord by used 2 Use only shielded cables to connect I O devices to this equipment Note THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT The Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada Customer Service amp Warranty Product Registration Thank you for purchasing a CyberPower product Prompt product registration entitles coverage under the Limited Warranty and also allows the opportunity to be notified of product enhancements upgrades and other announcements Registration is
27. m x 88mm x 236mm Environmental Humidity 0 to 95 Non condensing Altitude 13100 ft 4000 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals Certifications UL 60950 1 FCC Class A All specifications are subject to change without notice 6 2014 CyberPower Systems Inc All rights reserved Installation Guide CAUTION Please only use the provided screws for the entire installation process y a N For 1U Series Step 1 Mounting Bracket Installation Use the Mounting Bracket Screws 16 provided to attach the Mounting Brackets 2 to the ATS PDU Step 2 ATS PDU Mounting Use the Washers 4 and Screws 4 provided to secure the ATS PDU to your existing rack system Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the ATS PDU with the 4 Cord Retention Tray Mounting that are provided Use the Cable Ties provided to fasten each power cord to the Cord Retention Tray 2014 CyberPower Systems Inc All rights reserved Installation Guide For 2U Series Step 1 Mounting Bracket Installation Use the Mounting Bracket Screws 16 provided to attach the Mounting Brackets 2 to the ATS PDU Step 2 ATS PDU Mounting Use the Washers 4 and Screws 4 provided to secure the ATS PDU to your existing rack system Step 3 Cord Retention Tray Installation optional Attach
28. ough the available informational options G Enter Button Use to choose selected items enter to next level menu or return to previous menu H AC Inlet AC Power Cord Use to connect ATS PDU to utility power or UPS Ground Stud Use to ground the ATS PDU J AC Output Receptacles Provides power distribution for connected equipment K Outlet Indicator switched series only When the LED is on the outlet is providing power to connected equipment Technical Specifications Switched Series Metered Series PDU20SWHVT10ATNET PDU20MHVT10AT PDU20SW10ATNET PDU20M10AT Model Name PDU20SWTLOATNET PDU20SWHVCEE10ATNET PDU20MT10AT PDU20MHVCEE10AT PDU20SWHVIEC1OATNET PDU20MHVIEC10AT Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 16A 2 NEMA L6 20P 2 NEMA L6 20P 2 NEMA 5 20P Plug Type 2 NEMA 5 20P 2 IEC 309 16A NEMA Le 20p 2 IEC 309 16A 2 NEMA L5 20P 2 IEC 320 C20 2 IEC 320 C20 SR 12AWG SR 12AWG Power Cord Type SR 12AWG SR 12 AWG Socket Socket Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V C13 12A UL C13 12A UL Derated Output Current 16A 10A CE 16A 10A CE C19 16A C19 16A 8 IEC C13 8 IEC C13 Outlet Type NEMA 5 20R 2 IEC C19 NEMA 5 20R 2 IEC C19 Outlet Number 10 8 2 10 8 2 Transfer Time Typical B 12ms 16ms max 60Hz 18m
29. ower settings via LCD interface according to local power condition Available in both switched and metered monitored configurations users have a broad base of options to select the ATS PDU that best fits their needs Model List Switched Series Metered Monitored Series 1U 1U PDU15SW10ATNET PDU15M10AT PDU20SW10ATNET PDU20M10AT PDU20SWT1OATNET PDU20MT10AT PDU20SWHVT10ATNET PDU20MHVT10AT PDU15SWHVIEC12ATNET PDU15MHVIEC12AT PDU20SWHVIEC1OATNET PDU2OMHVIEC10AT PDU20SWHVCEE10ATNET PDU2OMHVCEE10AT 2U 2U PDU30SWT17ATNET PDU30MT17AT PDU30SWHVT19ATNET PDU30MHVT19AT Selected models may not be available in certain regions Please contact your CyberPower sales team for more information Safety Precautions Read the following before installing or operating the Automatic Transfer Switches ATS PDU Use only the supplied hardware to attach the mounting brackets The ATS PDU must be plugged into a single phase three wire grounded outlet on a circuit that is protected by a fuse or circuit breaker For PDU15xxxxx series please use 15A circuit protector For PDU20xxxxx series please use 20A circuit protector For PDU30xxxxx series please use 30A circuit protector Connection to any other type of power outlet may result in a electrocution hazard Do not use extension cords or adapters with these ATS PDUs Never install an ATS PDU or associated wiring or equipment during a lightning storm
30. p like the figure below 12 2014 CyberPower Systems Inc All rights reserved Installation Guide Removing the Power Cord Retention Clip Step 1 Remove the Power Cord Retention Clip by pushing it to the right as shown in the figure below Step 2 Remove the Power Cord Retention Clip by pulling the clip show in the image below to the left Operation Remote Management The remote management function provides for monitoring of the ATS PDU Operational information controlling outlets and utilizing SNMP functionality Web Remote management can be performed via web interface To access the web interface please follow the instructions below 1 Enter the IP address of the ATS PDU into a web browser Internet Explorer Firefox 2 Enter the user name and password of the ATS PDU device at the authentication screen Note The default username is cyber and the default password is cyber For additional information about the features and functionality of CyberPower Management Console please refer to the software Installation CD Telnet and SSH The CyberPower ATS PDU provides Telnet and Secure Shell SSH as Remote Management methods Telnet uses user name and password as basic security while SSH has a higher security level with encryption of the transmitted packets including user name password and data Configure the Setting of Telnet and SSH on the Web Interface The default user name and password is cyb
31. reshold Device Near Overload load COUneMration Bank 1 2 3 Threshold l Low Load Settings Threshold Immediate On Delay On Device Immediate Off Outlet Control All Outlet 1 N Bank 1 2 3 Delay Off Reboot Delay Reboot Brightness LCD Settings Scroll Mode Screen Off Reset All ATS PDU RMCARD and LCD Reset Except TCP IP Reset Reboot Reset Account User Name and Password Reboot LED Indicators Indicator Status Description Solid Green Selected source and power condition is normal Flashing Green Bankup source and power condition is normal Orange Power condition is abnormal Green The aggregate current of each bank is normal Orange Near overload Red Overload Off The ATS PDU power is off On Green The ATS PDU power is on Receiving transmitting data packet Flashing Reset finished On Indicates the ATS PDU is connected to the LAN Off Indicates the ATS PDU is not connected to the LAN On The outlet is on and providing power Outlet Off The outlet is off 14 2014 CyberPower Systems Inc All rights reserved Operation Environmental Monitoring optional The CyberPower ATS PDU with an environment sensor ENVIROSENSOR installed provides remote temperature and humidity monitoring in a server closet and or datacenter To connect ATS PDU with ENVIROSENSOR use RJ45 Ethernet Cable included with the ENVIROSENSOR Plug one end into the Environmental port on the RMCARD and the other end into the RJ45 port on the ENV
32. s max 50Hz Management and Communications Multifunction LCD Readout Voltage Frequency Load Current HW FW Version Network Information Software PowerPanel Business Edition SNMP HTTP Capable Yes with RMCARD203 a Connectivity RJ45 Serial Port Sensor Capable Optional Physical Dimension WxHxD 17 05 x 1 75 x 9 3 433mm x 44mm x 236mm Environmental Humidity 0 to 95 Non condensing Altitude 13100 ft 4000 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals UL 60950 1 UL 60950 1 UL 60950 1 FCC Class A UL 60950 1 FCC Class A COnsanICauOns FCC Class A UL 60950 1 FCC Class A UL 60950 1 CE FCC Class A CE FCC Class A All specifications are subject to change without notice 2014 CyberPower Systems Inc All rights reserved 5 Product Features Front Rear Panel Description 2U series 00 QO CyberPower PDU30SWT17ATNET Serial Port
33. se the contact information mentioned above for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment 3 You must provide a purchase receipt or other proof of the original purchase and provide a description of the defect What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required Who Pays for Shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with th
34. ure 6 Network Setting Menu Device Setup 24 2014 CyberPower Systems Inc All rights reserved Appendix B Power Device Network Utility Step 3 Authentication Enter the user name and password of the ATS PDU at the Authentication menu shown in Figure 7 Note The default username is cyber and the default password is cyber Authentication Enter the user name and password to save ch User name a a Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit gt Timeout Settings is used to specify the wait time when scanning for network ATS PDUs When there are many devices on the local network it may take extended periods of time to locate all the devices The timeout function is used to limit the search time The default setting is 3 seconds Valid values are 3 to 60 seconds Timeout Setting Figure 8 Timeout Setting 2014 CyberPower Systems Inc All rights reserved 25 CyberPower YNE Quality Value CyberPower Systems Inc www CPSww com KO1 0000322 01
35. utlets 21 for 12 outlets Gs Power Cord 10 feet IEC 320 C19 C20 x 2 PDU2Z0SWHVIEC1IOATNET PDU2ZO0MHVIEC10AT Model Only 2014 CyberPower Systems Inc All rights reserved Product Contents For 2U Series S ry amp 4 M3x4 Cord Retention ATS PDU Tray Mounting Screws Mounting Bracket x 2 24 M4x8 Bracket Mounting Screws Includes eight spares RJ45 DB9 Serial Port Connection Cable rer rF by 6 M5x12 Rack Mounting Screws Jumper Switched type only 6 Washers Includes two spares for each Registration Card Cord Retention Tray X 2 User Manual Registration Card CD Below items only provided with IEC type ATS DD Power Cord Retention Cable Clip x 27 INQ IEC Socket Power Cord Stand x 4 yr ry Ff amp 29 M3x4 Screws Cable Tie x 27 2014 CyberPower Systems Inc All rights reserved Product Features Front Rear Panel Description 1U 15A series Expansion Port ides SNMP Card Communication WY Serial Port NEMA Type Source A Source B 0 O 50 60 Hz 100 120v IEC Type Source A Source B o i E 50 60 Hz
36. wer Device Network Utility Install Power Device Network Utility for yourself or for anyone who uses this computer Everyone Just me tart cise Figure 2 Installation folder and settings Step 5 Select Next to comfirm the settings and install Step 6 Select Close to finalize the installation Launch Program To launch the Power Device Network Utility and get started select Programs from the Start menu in Windows and locate the new folder and icons for Power Device Network Utility Select Power Device Network Utility from the program folder Shown in Figure 3 Set Program Access and Defaues Figure 3 Power Device Network Utility 2014 CyberPower Systems Inc All rights reserved 23 Appendix B Power Device Network Utility Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and gateway address This allows the device s to function properly on the network and interface with CyberPower Management Console Step 1 Select the appropriate ATS PDU from the Equipment List Shown in Figure 4 Power Device Network Utility Fie Took Help Power Devices MAC Address IP Address Subnet Mask Gateway DHCP Nam mp 00 0C 15 40 09 A9 1921682420 255 255 2550 192 168 24 254 Enable PDU2 lt Figure 4 Equipment List Not