Home

Chief PAC525FC

image

Contents

1. ATTACHMENT attachment points at back of wall box or other appropriate Slide locking points cleats into place Tighten screws to secure STUD ATTACHMENT 7 Install template as temporary cover if needed to protect Drill pilot holes optional into studs through mounting from debris by folding tabs in and inserting into opening holes in box Wood studs use 3 16 bit If steel studs use 1 4 bit Install with 1 4 20 x 2 1 2 screws E and 3 8 flat washers 1 into pilot holes Sy Modify enclosure cover before attaching Break away tab s to allow wire exit from box and meet ventilation needs Box may be installed with outer flange removed for a pre sheetrock open stud mount configuration Gather wires and route through cover opening Install cover screw fasteners 2 into place to secure and complete enclosure Mounting Screw NOTE Plastic Save flange for NOTE Spacer reattachment after Locate front edge of box extended sheetrock is installed beyond studs by thickness of sheetrock to be used Installation Instructions PAC525 526 Installation Instructions PAC525 526 Installation Instructions PAC525 526 Installation Instructions USA International CHIEF Our Mounts Your Vision Europe Chief a products division of Milestone AV Technologies Asia Pacific 8800 002517 Rev01 2014 Milestone AV Technologies www chiefmfg com 09 14 gt T U gt T uU PAC525 526 6436 Ci
2. INSTALLATION INSTRUCTIONS PAC525 In Wall Accessory Boxes GCHIEF PAC525 526 Our Mounts Your Vision 525 526 DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved Mia WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are
3. athead 2 Phillips o Cover Box Frame Template Temporary Cover Grounding screw installed at factory P 1 4 20 x 2 1 2 Screw 6 32 x 3 8 Screw Security Hex Key 4 8 10 32 3 8 Earthing symbol IEC 60418 No 5019 affixed adjacent to grounding terminal o o 777777777777 6 32 Hex Nut 8 8 Flat VVasher 6 x 1 1 2 8x 4x Button Security Screw OPTIONAL PARTS PER CUSTOM CONFIGURATION NOT INCLUDED Conduit Connectors 3 x 2 Steel Old Electrical Narrow Handy Box Zip Ties Work Switch Box Outlet Cover Duplex 2 deep Raco 4864 or equiv Conduit Pipe 1 2 1 or 1 1 4 Raco 420 or equiv 525 526 Installation Instructions INSTALLATION 6 Plan box and component needs ito Sketch diagrams provided The PAC525 526 is intended for use both in installations where an existing finished drywall wall is present and where PAC525 the wall surface has not been finished and the structural studs are exposed The wall then must be finished around the opening of the box after the box has been installed eil WARNING All wiring should be performed by a licensed electrician following all local codes and ordinances AS LD a gt UL PAC525 526 Project Planning O Identify a suitable wall location for the accessory 2 Using a stud sensor locate and mark studs 3 Identify possible structural conflicts electrical wiring plumbing gasl
4. ines HVAC WARNING ELECTRICAL SHOCK HAZARD CUTTING PACS26 OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURYI ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARDI CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners Ll O z IU lt DS 4 Determine installation type Housing is designed to fit between two adjacent wall studs or onto a 1 2 minimum thickness drywall surface 6 Determine all components needed L Stud amp drywall attachment LI Conduit Pipe Ll Conduit Connectors large and small L Electrical Box es 3 x 2 Steel Electrical Box Cover s L Zip Ties L Electrical Outlet s L Pre sheetrock attachment Installation Instructions PAC525 526 Site Preparation 7 Using a level draw a horizontal line at lower edge of install site A STUD ATTACHMENT create exploratory hole to confirm edge of stud studs B DRYWALL ATTACHMENT mark horizontal cut locations ensuring a minimum 1 2 distance from each stud Align on lower edge drawn line A and horizontal marking for inside stud location B Use enclosed template or housi
5. ng as a template drawing line around top and sides of housing gt B Mark the four corners 9 Cut along outside edge of line using utility knife Remove drywall NOTE Cutting past corners weakens the cleats ability to hold securely PAC525 526 PAC525 526 Box Preparation ri Remove knock outs in box as predetermined in step 5 02 Loosely attach components conduit cut to length to box to ease fitting into vvall opening Use four 6 screws F and nuts H to assemble the switch box from either inside or outside the PAC525 or PAC526 PAC525 526 Box Installation 03 Feed attached conduit through cut out and insert box into opening in wall Tighten component connections Once wall opening is completed check stud depth If 3 5 or greater proceed to step 11 If less than 3 5 deep modify depth of box as follows before proceeding CAUTION Injury may occur on sharp edges Carefully discard the removable tabs B Snap off removable tabs at perforations provided CAUTION Avoid sharp edges A Remove box flange by removing screws C Reinstall box flange Reattach screws 525 526 Installation Instructions Secure box into place by methods PAC525 526 Final Finishing Using preferred attachment method zip ties bands etc SES none included secure AV components and cables within DRYWALL the wall box Attachment methods may use integrated
6. properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this accessory can result in serious personal injury or damage to equipment lt is the installer s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located in the accessory does not exceed 10 lbs 4 5 kg WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING For indoor use only Installation Instructions IMPORTANT The PAC525 526 mounts are designed to be mounted to a 2 x 4 wood stud wall 16 on center a 2 x 4 25ga minimum steel studs wall or to a 1 2 minimum thickness drywall surface 10 TE Spacings Minimum spacings between the 120 Vac power components and the A V components shall be main tained for safe operation of the equipment when installed in accordance with the National Electric Code ANSI NFPA 70 10 TE When selecting a Listed 120 Vac Receptacle for use as the main power source for the PAC Series boxes to power the A N equipment make sure that AC Receptacle is rated at lea
7. st 15A and it is used in the building s AC branch circuit that is connected to a circuit breaker rated at least 15A Do not connect more than 12A from the Receptacle In the U S the equipment shall be installed per the applicable requirements of the National Electrical Code ANSI NFPA 70 In Canada the equipment shall be installed per the applicable requirements of the Canadian Electrical Code CSA C22 1 VOTE Itis the installers responsibility to ensure that the enclosure is bonded to the ground in the switch box in accordance with the National Electric Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 A green grounding screw is provided in the enclosure for the purpose if required SAVE THESE INSTRUCTIONS Installation Instructions PAC525 526 DIMENSIONS 9X 75 25 ZIP TIE ANCHORHOOKS 14x 75X 25 ZIP TIE ANCHORHOOKS 525 526 LEGEND Tighten Fastener Befestigungsteil festziehen Loosen Fastener Desserrez les fixations Phillips Screwdriver Tournevis pointe cruciforme Flathead Screwdriver Mark level line Installation Instructions Pencil Mark Marcar con l piz Stiftmarkierung Marcar com l pis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Adjust Remove Precision hand cut surface Installation Instructions PAC525 526 TOOLS REQUIRED FOR INSTALLATION AN 9 G lt 3 16 Stud Sensor 1 4 2 Fl
8. ty West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477

Download Pdf Manuals

image

Related Search

Related Contents

  the 2245THW™ Handbook  ft brisol marino    Eventide Atlas Recorder User Manual  (2“ 1  28010028_TS5103_UserManual_ ITA_Rev00        

Copyright © All rights reserved.
Failed to retrieve file