Home
Black Box LB9217A-R2 network switch
Contents
1. 18 Port based VLAN amp Settings enne 19 MAC based Trunking Settings sse 21 Technical Specifications 23 Physical Specifications 23 Appendix A Connector Pinouts 24 Figure 5 RJ 45 Connector and Cable Pins 24 Table 6 Connector Pin Out 24 Express Ethernet Switch LB9217A R2 amp Applicable Modules Introduction 17 Port Modular Fast Ethernet Switch High Port Count The 17 Port Switch is a modular switch consisting of three expansion slots two for 8 port 10 100BaseTX FX module and one for 1 port 10 100BaseTX or 100BaseFX module This allows the switch to provide up to 17 ports when all the three slots are fit with modules Cost Effective Migration The 17 Port Switch is capable of integrating legacy 10Mbps networks with 100Mbps Fast Ethernet networks In addition the 17 Port Switch provides an easy and affordable solution for migrating from copper cabling to fiber connection when it is equipped with suitable modules to provide both TX and
2. CAPS NUM Cep Printecho Connected 00 27 09 Auto detect 9600 8 N 1 20 Express Ethernet Switch LB9217A R2 amp Applicable Modules MAC based Trunking amp Settings Trunking is also called link aggregation which serves as a shortcut to increase the bandwidth on your network Trunking is a method of physically linking together several ports to act as a single port with higher bandwidth This functionality allows scaling of bandwidth The 17 Port Switch supports trunking of up to 4 ports either 2 port or 4 port For a 100BaseTX FX network you will gain 400Mbps bandwidth when you trunk two ports each of 200Mbps The more ports you trunk the more bandwidth you gain Follow these steps to configure the 2 port trunking Move the cursor to TRUNK column Move the cursor and select port 1 Press SPACE and show T to port and port2 Press ENTER to apply and save the setting Ele Ea all Transfer Help D 157 AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO KKKKKKKKKK ZKKK KKK KEY SPACE TO CHANGE MODE OPTION AVAILABLE AUTO 10FD 10HD 100FD 100HD Connected 00 07 13 Auto detect 9500 8 N 1 SCROLL CAPS NUM Printecho lt NOTE gt Can only choose portl and port2 for 2 port trunking Follow these steps to configure the 4 port trunking Move the cursor to TRUNK column Move the cursor and select port 1 Press SPACE and show T to port
3. m aute pe te metes 9 Front Panel A ec tecla ette eerte 9 Figure 1 Front View of the 17 Port Switch 9 Table 1 Port Status ossessione ass oiai ios thats enses tosta aw aaa sensn 10 Table 2 Port status on single port Module 11 ISHAM 9 12 Selecting Site for the Switch nae eat terere tenerte 12 Connecting tO PWET 5 intente ee ette be re rese ep ette teet 12 Figure 3 Rear view of the switceh 12 Connecting to Your Network sss 13 Table 3 Cable Specifications 13 Figure 4 Removal of cover plate Fiber module being installed 14 Switch Configuration e eere eee reete esee etes notata 15 Setting up Console Port Connection sees ener 15 Console Port Default Settings 15 Matin 16 POM Settings neti R eet 17 Table 4 Mode Setting on FX Ports 17 Table 5 Mode Setting on TX Ports
4. provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Mark Warning C This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protection requirement of Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility Company has an on going policy of upgrading its products and it may be possible that information in this document is not up to date Please check with your local distributors for the latest information No part of this document can be copied or reproduced in any form without written consent from the company Trademarks All trade names and trademarks are the properties of their respectiv
5. FX ports Elexibility through Modules Seeing fiber connection become popular while the fiber cabling in small business environment is still not widespread the 17 Port Switch is designed to deliver flexibility through a wide variety of TX and FX modules Most of the modules combine TX and FX ports to provide more customization options NOTE Desired module shall be ordered separately Fiber Connectivity As a Fast Ethernet switch the 17 Port Switch is specifically designed to meet the demanding need for fiber The switch provides up to 17 ports for 100BaseFX multi mode or single mode fiber For multi mode fiber port it allows SC ST MT RJ VF 45 or LC connector For single mode fiber port it allows SC or ST connector The fiber ports allow maximum segment distance of 120 km when using single mode fiber and therefore the 17 Port Fiber Switch is an optimum solution for long distance connection Basic Configuration Features The 17 Port Switch supports port based Virtual Local Area Networking VLAN and MAC based trunking technologies Such advanced features bring network administrators a powerful yet easy to use tool to reduce unnecessary traffic efficiently segment the network and enhance network security Standards Compliant The 17 Port Switch fully complies with IEEE802 3 10BaseT as well as IEEE802 3u 100BaseTX FX standards Express Ethernet Switch LB9217A R2 amp Applicable Modules Product Features Base un
6. Off Connection in half duplex mode O Port Status on Single Port Module A set of two LEDs conveys the port status on the single port module Consult Table 2 for details 10 Express Ethernet Switch LB9217A R2 amp Applicable Modules Table 2 Port status on single port Module LED State Indication A valid network connection Steady established LNK stands for LINK san Transmitting or receiving data Flashin PAGE 9 ACT stands for ACTIVITY Off No valid network connection established Steady Connection in full duplex mode FDX FDX stands for FULL DUPLEX Off Connection in half duplex mode Ports Up to 17 Dorts The 17 Port Switch provides up to 17 ports for 10 100BaseTX or 100BaseFX etc Multi Connectivity The 8 port modules allow for 10 100BaseTX or 100BaseFX and the single port modules allow for 10 100BaseTX or 100BaseFX For 100BaseFX modules the multi mode fiber ports accommodate ST SC MT RJ VF 45 or LC connector and the single mode fiber ports accommodate SC or ST connector Longer Segment Distance The maximum connection distance between a node and a switch port is up to 120 km over single mode fiber for 100BaseFX networks For information on the cables for fiber module installation please refer to Table 3 11 Express Ethernet Switch LB9217A R2 amp Applicable Modules Installation This chapter gives step by step installation instructions for the 17 P
7. instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 Elaparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Express Ethernet Switch LB9217A R2 amp Applicable Modules 10 11 12 13 14 15 16 17 18 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructi
8. S BLACK BOX NETWORK SERVICES Jan 2007 Express Ethernet Switch Modular Unit LB9217A R2 1 Port Module LB9220C ST R2 LB9220C SC R2 8 Port Module LB9213A LB9214A LB9215A LB9216A LB9218A LB9219A CUSTOMER Order toll free in the U S Call 877 877 BBOX Outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax SUPPORT INFORMATION 124 140 0718 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Express Ethernet Switch LB9217A R2 amp Applicable Modules FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENT Class A Digital Device This equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encour
9. aged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult an experienced radio TV technician for help Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To meet FCC requirements shielded cables and power cords are required to connect this device to a personal computer or other Class A certified device This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada Normas Oficiales Mexicanas NOM INSTRUCCIONES DE SEGURIDAD 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus
10. and port2 Move the cursor and select port 3 Press SPACE and show T to port3 and port4 Press ENTER to apply and save the setting 21 Express Ethernet Switch LB9217A R2 amp Applicable Modules PORT TYPE MODE FLW TRUNK VLANL i0 ii 12 Connected 00 09 20 Auto detect 96008 N 1 SCROLL Cars NUM Capture Printecho lt NOTE gt The trunking ports will be disabled for VLAN group settings 22 Express Ethernet Switch LB9217A R2 amp Applicable Modules Technical Specifications 17 Port Switch Applicable Standards IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX FX Optional 8 port Module Type LB9213A LB9214A LB9215A LB9216A LB9218A LB9219A 10 100BaseTX module 100BaseFX module multi mode or single mode Optional 1 port Module Type LB9220C ST R2 LB9220C SC R2 10 100BaseTX module 100BaseFX module multi mode or single mode Speed 10BaseT 20Mbps for full duplex 10Mbps for half duplex 100BaseTX FX 200Mbps for full duplex 100Mbps for half duplex Switching Method Store and Forward Performance 148 800pps forwarding rate per port for 100Mbps Chassis LED I ndicators Power Module LED ndicators For 8 port module LNK ACT FDX COL 2 LEDs 14 880pps forwarding rate per port for 10Mbps For 1 port module LNK ACT FDX 2 LEDs Physical Specifications 17 Port Switch Dimensions 440 x 285 x 45 mm 19 Ra
11. anel The front panel of the 17 port Switch consists of three expansion slots to house two 8 port modules and one single port module An array of LED indicators on each module provides you with instant feedback on the status of the switch Figure 1 Front View of the 17 Port Switch Express Ethernet Switch LB9217A R2 amp Applicable Modules LEDs amp Reset Button The array of LED indicators on the front panel conveys status and configuration information to help you monitor and troubleshoot the switch e Reset Button Port Status on Single Port Module o Power e Port Status on 8 Port Modules Power This LED comes on when the switch is connected to power and turned on O Reset Button If the switch should become unresponsive you may reset it by pressing this button O Port Status on 8 Port Modules The front panel of the 17 Port Switch allows two 8 port modules The ports numbered from 1 to 8 on full TX module The LEDs are located at the left side of each section displaying status for each respective port Please refer to Table 1 for more details Table 1 Port Status LED State Indication A valid network connection Steady established LNK ACT LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY Connection in full duplex mode y FDX stands for FULL DUPLEX FDX COL Flashin Collision occurred 9 COL stands for COLLISION
12. cable Modules Main Menu This main menu shows you the default configuration of the switch By default all TX ports are set at auto negotiation and flow control on all FX ports are set at 100Mbps with full duplex and flow control off and all ports are grouped into V1 VLAN group 1 amp 9600 HyperTerminal Unlicensed la x Ele Edit View Call Transfer Help D Z sb 8 PORT TYPE MODE FLU TRUNK VLANI 2 3 4 5 6 7 8 91011 12 13 l4 15 16 USE KEY SPACE TO CHANGE MODE OPTION AVAILABLE AUTO 1OFD 10HD 100FD 100HD Connected 00 07 26 T100 9600 8 N 1 SCROLL CAPS NUM Printecho These are the valid commands capitalization is not required W Move the cursor up S Move the cursor down A Move the cursor to the left D Move the cursor to the right R Default V Routing SPACE Option ENTER Apply and save the setting ESC Abort 16 Express Ethernet Switch LB9217A R2 amp Applicable Modules Port Settings The duplex mode and speed can be altered and the flow control can be turned on off to accommodate special needs Follow these steps to change the speed duplex mode setting or to toggle flow control ON OFF e Move the cursor to MODE column to change the speed duplex mode setting or move the cursor to FLW column to change the flow control setting e Move the cursor and select a port e Press SPACE and select a desired setting from the list that app
13. ckmount Size 1U Weight 3 4kg 7 516 Power I nput 100 240 Vac 50 60 Hz Power Consumption 52W Max Operating 0 45 32 113 F Temperature Storage Temperature 10 70 14 158 F Humidity 10 90 non condensing Emissions FCC part 15 Class A CE Mark 23 Express Ethernet Switch LB9217A R2 amp Applicable Modules Appendix A Connector Pinouts Pin arrangement of RJ 45 connectors sS Figure 5 RJ 45 Connector and Cable Pins The following table lists the pinout of 10 100BaseT TX ports Table 6 Connector Pin Out Pin Regular Ports Uplink port 1 Input Receive Data Output Transmit Data 2 Input Receive Data Output Transmit Data 3 Output Transmit Data Input Receive Data 4 NC NC 5 NC NC 6 Output Transmit Data Input Receive Data 7 NC NC 8 NC NC 24
14. cross over cable Consult Table 3 below for cabling requirements based on connectors and speed Connect one end of the cable to the switch and the other end to a desired device Once the connections between two end devices are made successfully turn on the power and the switch is operational Cable Length The maximum distance between a node and a directly connected switch port on a 100BaseFX network is 120 km using 10 125um single mode fiber optic cable It is capable of spanning at most 2 kilometers when use of 62 5 125u m multi mode fiber optic cable Table 3 Cable Specifications Speed Connector Port Speed Cable Max Duplex 10BaseT RJ 45 10 20 Mbps Cat 3 4 or 100m 5 UTP STP 100BaseTX RJ 45 100 200 Cat 5 Mbps UTP STP 100BaseFX ST SC MT 100 200 62 5 125 RJ VF 45 Mbps um multi LC mode fiber 100BaseFX 5 ST 100 200 10 125 um 1120 km Mbps single mode fiber 13 Express Ethernet Switch LB9217A R2 amp Applicable Modules Module Installation The installation for 8 port module and single port module is the same Take single port fiber module for example e Remove the module from the static free container e Unscrew the cover plate of the expansion slot The slot for single port module is located at the right side of the switch e Remove the plate and keep it for future use when you decide to remove this module e With the power off slide the module into the desired slot foll
15. e companies Copyright O 2007 AII Rights Reserved Express Ethernet Switch LB9217A R2 amp Applicable Modules Preface This manual describes how to install and use the 17 Port Fast Ethernet Switch The switch introduced here is a base unit providing 3 expansion slots including two slots for 8 port modules and one slot for single port module The 8 port modules allow for 10 100BaseTX or 100BaseFX the single port module allows for 10 100BaseTX or 100BaseFX Over a dozen of TX and FX modules or a combination of TX FX are available for fitting the switch Furthermore the 17 Port Switch supports port based VLAN and MAC based trunking technologies To get the most out of this manual you should have an understanding of networking concepts such as bridging IEEE 802 3u 100BaseTX FX Fast Ethernet and local area networks LANs In this manual you will find Features on the 17 Port Switch Illustrative LED functions Installation instructions Configuration instructions for VLAN amp trunking Specifications Express Ethernet Switch LB9217A R2 amp Applicable Modules Table of Contents jr 5 Table of Contents eere ette en 6 INtTrOCUUCTON u u saw 7 17 Port Modular Fast Ethernet Switch ener 7 Prod ct Features sete eren mtm it e et e Ret 8 PACKING
16. ears on the screen Press ENTER to apply and save the setting FX Ports The port setting for the fiber module is slightly different from the TX port Consult the following table for a brief description on FX ports Table 4 Mode Setting on FX Ports Communication Description Mode p control Always N off and can not be changed 100FD 100Mbps at full duplex mode 100HD 100Mbps at half duplex mode 17 Express Ethernet Switch LB9217A R2 amp Applicable Modules TX Ports Consult the following table for a brief description on TX ports Table 5 Mode Setting on TX Ports Communication Description Mode p Flow control on off Y on N off Auto Auto Negotiation 100Mbps at full duplex 100FD mode 100HD 100Mbps at half duplex mode 10FD 10Mbps at full duplex mode 10HD 10Mbps at half duplex mode 18 Express Ethernet Switch LB9217A R2 amp Applicable Modules Port based VLAN amp Settings The 17 Port Switch allows up to sixteen port based VLAN domains Assign each port to a VLAN group or a couple of VLAN groups according to accessibility needs The VLAN setting follow these steps to assign VLAN groups e Move the cursor to VLANI 16 column e Move the cursor and select a port Press SPACE and show V to the desired port Press ENTER to apply and save the setting For example here we have the port 17 assigned as routing upl
17. ink port The port 1 port 16 are divided into five different VLAN groups VLAN 1 2 3 4 and 5 VLAN 1 port 1 2 3 VLAN 2 port 4 5 6 VLAN 3 port 7 8 9 VLAN 4 port 10 11 12 VLAN 5 port 13 14 15 16 17 For example the port 1 2 and 3 VLAN 1 can not communicate with the port 4 5 and 6 VLAN 2 Cossec 011906 000 1 car NUM The routing uplink port setting follow these steps to have an assigned routing uplink port Then separate the rest each port to a different VLAN group The rest each port can only uplink through the assigned routing uplink port and can t communicate with each other Enter V from the Main Menu Move the cursor to a desired routing uplink port 9 Press SPACE and show V to the desired routing uplink port 9 Press ENTER to apply and save the setting then all the other ports will be assigned to each different VLAN group and use the desired port as the routing uplink port For example here we have the port 17 assigned as routing uplink port The port 1 port 16 are divided into each different VLAN groups And the user on the port 1 port 16 can uplink through the port 17 only and can not communicate with each other 19 Express Ethernet Switch LB9217A R2 amp Applicable Modules Fie Edit View Call Transfer Help Das 2 s Ex PORT TYPE MODE FLW TRUNK VLANi TX TX TX TX TX TX TX TX TX LEFT D ENTER
18. it with three expansion slots Auto negotiation for speed and duplexity on TX ports Auto MDI MDI X on TX ports Store and forward mechanism True non blocking architecture Full wire speed forwarding rate Broadcast storm filtering Back pressure and IEEE 802 3x compliant flow control Supports 12K MAC addresses Supports 2M Bytes buffer memory Front panel reset button Front panel port status LEDs Standard 19 rack mount size one unit height Modules Allows two 8 port expansion modules each of up to eight ports for 10 100BaseTX or 100BaseFX Allows one single port expansion module one port for 10 100BaseTX or 100BaseFX Connectors Choices of SC ST MT RJ VF 45 or LC connectors for 100BaseFX multi mode fiber module SC or ST connector allowed for 100BaseFX single mode fiber module Basic Configuration Support Supports port based VLAN amp MAC based Trunking Programmable re configuration for fixed speed and duplexity Programmable re configuration for Back pressure and IEEE 802 3x compliant flow control Express Ethernet Switch LB9217A R2 amp Applicable Modules Packing List When you unpack this product package you will find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to our authorized reseller e The 17 Port Switch User s Manual AC power cord e RS232 cable e Rack Mount Ears with screws Front P
19. ort Switch Selecting a Site for the Switch As with any electric device you should place the switch where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 32 and 113 degrees Fahrenheit 0 to 45 degrees Celsius The relative humidity should be less than 90 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the switch receives adequate ventilation Do not block the ventilation holes on each side of the switch or the fan exhaust port on the rear of the switch The power outlet should be within 1 8 meters of the switch Connecting to Power Connect the supplied AC power cord to the receptacle on the back of the switch and then plug it into a standard AC outlet with a voltage range from 100 to 240 Vac Figure 3 Rear view of the switch 12 Express Ethernet Switch LB9217A R2 amp Applicable Modules Connecting to Your Network Cabling First ensure the power of the switch and end devices is turned off NOTE Always ensure that the power is off before any installation Prepare cable with corresponding connectors for each type of port in use NOTE To connect two regular RJ 45 ports between switches or hubs you need a
20. owing the internal plastic guide rails Once itis slid in fully snap in the module to make a proper connection and fasten the screws Finally turn on the power Consult the following illustrations before installation lt NOTE gt Before you start with any installation ensure that the power is off The module is not hot swappable Figure 4 Removal of cover plate Fiber module being installed 14 Express Ethernet Switch LB9217A R2 amp Applicable Modules Switch Configuration This section explains the configuration of VLAN and trunking settings Setting up Console Port Connection To configure your switch through the console port it is necessary to first configure a terminal emulation program The HyperTerminal for Windows 95 98 and NT is suggested e First check the switch cables and computers for proper installation before configuration e Connect a PC or any VT100 compatible terminal to the console port on the back of the unit using one RS232 serial cable Turn on both end devices e Configure the baud rate and character format of the terminal or PC to match the default settings shown below Console Port Default Settings Terminal type VT100 Port type COM 1 4 8 data bits 1 stop bit no Communication parity baud rate of Mode 115200bps for initial configuration Flow Control Yes Hardware N A Compression 15 Express Ethernet Switch LB9217A R2 amp Appli
21. vo de operaci n o como se indique en el aparato Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante En caso de existir una antena externa deber ser localizada lejos de las lineas de energia El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E Elaparato ha sido tirado o su cubierta ha sido da ada Express Ethernet Switch LB9217A R2 amp Applicable Modules FCC Certifications This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to