1. Part number Feature code Description Monitor kits and keyboard trays 17238BX 1723HC1 fc ASEK 1U 18 5 Standard Console 17238EX 1723HC1 fc ASEL 1U 18 5 Enhanced Media Console 172317X 1723HC1 fc 0051 1U 17in Flat Panel Console Kit 172319X 1723HC1 fc 0052 1U 19in Flat Panel Console Kit Console switches 3858D3X 3858HC1 fc A4X1 Avocent Universal Management Gateway 6000 1754D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager LCM8 Console cables 00AK142 A4X4 UM KVM Module VGA SD Dual RJ45 43V6147 3757 Single Cable USB Conversion Option UCO 39M2895 3756 USB Conversion Option 4 Pack UCO 39M2897 3754 Long KVM Conversion Option 4 Pack Long KCO 46M5383 5341 Virtual Media Conversion Option Gen2 VCO2 46M5382 5340 Serial Conversion Option SCO For more information see the list of Lenovo Press Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack System x3100 M5 37 Related publications and links For more information see the following documents U S Announcement letter http ibm com common ssi cgi bin ssialias infotype dd amp su
2. 39Y8934 DPI 32amp 250V Front end PDU with IEC 309 2P Gnd connector 39Y8935 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd connector 39Y8938 30amp 125V Front end PDU with NEMA L5 30P connector 39Y8939 30amp 250V Front end PDU with NEMA L6 30P connector 39Y8940 60amp 250V Front end PDU with IEC 309 60A 2P N Gnd connector System x3100 M5 34 Table 30 Power distribution units part 2 of 2 Part number Description Universal PDUs 39Y8951 DPI Universal Rack PDU w US LV and HV power cords 39Y8952 DPI Universal Rack PDU w CEE7 VII Europe LC 39Y8953 DPI Universal Rack PDU w Denmark LC 39Y8954 DPI Universal Rack PDU w Israel LC 39Y8955 DPI Universal Rack PDU w ltaly LC 39Y8956 DPI Universal Rack PDU w South Africa LC 39Y8957 DPI Universal Rack PDU w UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU w China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI Universal Rack PDU India OU Basic PDUs 46M4122 OU 24 C13 16A 3 Phase PDU 46M4125 OU 24 C13 30A 3 Phase PDU 46M4128 OU 24 C13 30A PDU 46M4131 OU 24 C13 32A PDU 46M4140 OU 12 C19 12 C13 60A 3 Phase PDU 46M4143 OU 12 C19 12 C13 32A 3 Phase PDU For more information see the list of Lenovo Press Product Guides in the Power infrastructu
3. 200GB SAS 2 5 MLC HS Enterprise SSD 8 49Y6134 A3EY 400GB SAS 2 5 MLC HS Enterprise SSD 8 49Y6139 A3F0 800GB SAS 2 5 MLC HS Enterprise SSD 8 System x3100 M5 The following table lists the supported 3 5 inch hot swap drives Table 8 3 5 inch hot swap disk drive options Part number Feature Description Maximum code supported 3 5 inch 15K SAS HDDs 512 byte sector drives 49Y6092 A3DV 300GB 15K 6Gbps SAS 3 5 G2HS HDD 4 49Y6097 A3DW 450GB 15K 6Gbps SAS 3 5 G2HS HDD 4 49Y6102 A3DX 600GB 15K 6Gbps SAS 3 5 G2HS HDD 4 3 5 inch NL SATA HDDs 512 byte sector drives 81Y9786 A22Y 500GB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 81Y9790 A22P 1TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 81Y9794 A22T 2TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 81Y9798 A22S 3TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 49Y6002 A3W9 4TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 3 5 inch NL SATA HDDs 512e Advanced Format drives OOFN113 A5VD 2TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN128 A5VF 3TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN143 A5VH 4TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN158 A5VK 5TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN173 A5VM 6TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 3 5 inch NL SAS HDDs 512e Advanced Format drives 00ML203 AS76 2TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e HDD 4 00ML208 A
4. 81Y4492 A1XL ServeRAID H1110 SAS SATA Controller 1 C5x EEx 81Y4448 A1MZ ServeRAID M1115 SAS SATA Controller 1 F3x EGx EHx EJx 81Y4481 A347 ServeRAID M5110 SAS SATA Controller 1 EKx 46C8988 A3MW N2115 SAS SATA HBA for System x 1 46M0907 5982 6Gb SAS HBA 1 System x3100 M5 The following table lists the supported upgrades to the internal RAID controllers and HBAs Table 10 Upgrades for internal storage controllers Part Feature Description Maximum Models number code supported where used Upgrades for the ServeRAID C100 81Y4406 A17U ServeRAID C100 Series RAID 5 Upgrade for System x FoD 1 Upgrades for the ServeRAID M1115 SAS SATA Controller 81Y4542 A1X1 ServeRAID M1100 Series Zero Cache RAID 5 Upgrade for 1 System x Upgrades for the ServeRAID M5110 SAS SATA Controller 81Y4508 A22E ServeRAID M5100 Series Battery Kit 1 Supported only with 512MB cache option 81Y4484 81Y4544 A1X2 ServeRAID M5100 Series Zero Cache RAID 5 Upgrade for 1 System x 81Y4484 A1J3 ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade for 1 System x 81Y4487 A1J4 ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade for 1 EKx System x 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade for 1 System x 81Y4546 A1X3 ServeRAID M5100 Series RAID 6 Upgrade for System x 1 90Y4
5. GB ServeRAID 4x 3 5 SS 1x 1TB 2x GbE DVD 1x 350W 1 2 EAx 3MB 1600MHz 2C 54W 1600 MHz C100 NL SATA fixed 5457 Xeon E3 1220 v3 3 1GHz 2x 8 GB ServeRAID 4x 3 5 SS Open 2x GbE Multi 1x 350W 1 2 EBx 8MB 1600MHz 4C 80W 1600 MHz C100 burner fixed 5457 Xeon E3 1220 v3 3 1GHz 1x 8 GB ServeRAID 4x 3 5 SS 1x 1TB 2x GbE Multi 1x 350W 1 2 ECx 8MB 1600MHz 4C 80W 1600 MHz C100 NL SATA burner fixed 5457 Xeon E3 1220 v3 3 1GHz 1x 8 GB ServeRAID 4x 3 5 SS 2x 1TB 2x GbE Multi 1x 350W 1 2 EDx 8MB 1600MHz 4C 80W 1600 MHz C100 NL SATA burner fixed 5457 Xeon E3 1231 v3 3 4GHz 1x 8 GB ServeRAID 4x 3 5 SS Open 2x GbE Multi 1x 350W 1 2 EFx 8MB 1600MHz 4C 80W 1600 MHz C100 burner fixed Standard tower form factor hot swap drives and power supplies 5457 Xeon E3 1220 v3 3 1GHz 1x 8 GB ServeRAID 8x 2 5 HS Open 2x GbE Multi 1x 430W 2 2 EEx 8MB 1600MHz 4C 80W 1600 MHz H1110 burner hot swap 5457 Xeon E3 1220 v3 3 1GHz 1x 8 GB ServeRAID 8x 2 5 HS 1x 300GB 2x GbE Multi 1x 430W 2 2 EGx 8MB 1600MHz 4C 80W 1600 MHz M1115 10K SAS burner hot swap 5457 Xeon E3 1220 v3 3 1GHz 1x 8 GB ServeRAID 8x 2 5 HS Open 2x GbE Multi 2x 430W 2 2 EHx 8MB 1600MHz 4C 80W 1600 MHz M1115 burner hot swap 5457 Xeon E3 1271 v3 3 6GHz 1x 8 GB ServeRAID 8x 2 5
6. are not typically seen in this class of system such as standard embedded RAID 0 and RAID 1 remote control capabilities even when the machine is powered off and Predictive Failure Analysis PFA on processor and memory Some models also support hot swap redundant power supplies and hot swap disk drives System x3100 M5 1 Key features Often small to medium sized businesses SMBs have limited IT budget and resources and rely on partners or multitalented employees to help manage the company s network Business needs for efficiency improvement and retention of critical data require the usage of a server that is easy to get up and running quickly and is dependable You need to squeeze as much as possible out of your IT dollars while saving costs on features that are not needed in an SMB environment The System x3100 M5 is an ideal first server to meet those business needs It was built for speed yet eliminates costly design features that are found in general purpose servers that are unnecessary for smaller businesses Scalability and performance The x3100 M5 offers numerous features to boost performance improve scalability and reduce costs e The single socket x3100 M5 supports the quad core Intel Xeon Processor E3 1200 v3 Haswell family of processors which offer impressive computing power in a space saving mini tower design e Choice of processors with up to four cores to enable the effective usage of multi threaded applications
7. bit operating systems and applications L3 cache Integrated in the processor Up to 2 MB for Intel Celeron processors Up to 3 MB L3 for Intel Pentium processors Up to 4 MB L3 for Intel Core i3 processors Up to 8 MB L3 for Intel Xeon E3 1200 v3 processors Chip set Intel C222 formerly known as Intel Lynx Point PCH and Intel Denlow platform Memory DIMM slots Four DDR3 DIMM slots supporting UDIMMs RDIMMs are not supported Memory capacity Up to 32 GB with 8 GB DDR3 UDIMMs and four populated DIMM slots Memory protection ECC Disk drive bays Compact tower Up to four 3 5 simple swap bays Standard tower Up to four 3 5 hot swap bays HDDs or eight 2 5 hot swap bays HDDs or SSDs Maximum internal storage Compact tower Up to 12 TB with 3 TB 3 5 simple swap NL SATA HDDs Standard tower Up to 24 TB with 6 TB 3 5 hot swap NL SATA HDDs or up to 8 TB with 1 TB 2 5 hot swap NL SAS HDDs or upto 12 8 TB with 1 6 TB 2 5 hot swap SSDs RAID support Software RAID 0 1 or 10 with ServeRAID C100 controller upgradeable to RAID 5 Optional hardware RAID with ServeRAID H1110 RAID O 1 1E or 10 or M1115 RAID 0 1 10 optional RAID 5 or 50 or M5110 RAID O 1 10 optional 5 50 6 or 60 and optional cache with flash backup Additional upgrades for M5110 For compact tower using the hardware RAID adapter also requires a RAID upgrade kit 00J6352 Optical
8. fixed power supply Height 360 mm 14 2 in Width 180 mm 7 1 in Depth 480 mm 18 9 in Weight o Minimum ship configuration 10 kg 22 0 Ib o Maximum ship configuration 13 kg 28 7 Ib Dimensions and weight standard tower systems with redundant hot swap power supplies Height 439 mm 17 3 in Width 217 mm 8 6 in Depth 569 mm 22 4 in Weight o Minimum ship configuration 19 6 kg 43 Ib o Maximum ship configuration 22 0 kg 48 5 Ib Supported environment e Temperature o Server on e 10 0 to 35 0 C 50 to 95 F altitude 0 to 914 4 m 3 000 ft e 10 0 to 32 0 C 50 to 89 6 F altitude 914 4 m 3 000 ft to 2 133 6 m 7 000 ft e Supports up to 40 C 104 F when the Operating Temperature Enhancement Kit is installed o Server off e 10 0 to 43 0 C 50 to 109 4 F maximum altitude 2 133 6 m 7 000 ft o Shipping e 40 to 60 C 40 to 140 F e Relative humidity 8 to 80 e Maximum altitude 2 133 6 m 7 000 ft System x3100 M5 23 Electrical 430 watt power supply 100 127 nominal V ac 50 60 Hz 6 0 A maximum 200 240 nominal V ac 50 60 Hz 3 0 A maximum Input kilovolt amperes kVA approximately o Minimum configuration 0 100 kVA o Maximum configuration 0 506 kVA 350 watt power supply e 100 127 nominal V ac 50 60 Hz 7 0 A maximum e 200 240 nominal V ac 50 60 Hz 3 5 A maximum e Input kilovolt amperes
9. in the Backup units category http www redbooks ibm com portals systemx Open amp page pg amp cat tape System x3100 M5 31 Top of rack Ethernet switches The server supports the top of rack Ethernet switches from Lenovo that are listed in the following table Table 28 Top of rack switches Part number Description 1 Gb top of rack switches 7309BAX RackSwitch G7028 24 ports 7309CAX RackSwitch G7028 48 ports 0446013 RackSwitch G8000R 7309CFC RackSwitch G8000F 7309G52 RackSwitch G8052R 730952F RackSwitch G8052F 10 Gb top of rack switches 7309DRX RackSwitch G8264CS Rear to Front 7309DFX RackSwitch G8264CS Front to Rear 7309BR6 RackSwitch G8124ER 7309BF7 RackSwitch G8124EF 7309G64 RackSwitch G8264R 730964F RackSwitch G8264F 7309CR9 RackSwitch G8264TR 7309CF9 RackSwitch G8264TF 40 Gb top of rack switches 8036BRX RackSwitch G8332 Rear to Front 8036BFX RackSwitch G8332 Front to Rear 8036ARX RackSwitch G8316R 8036AFX RackSwitch G8316F System x3100 M5 For more information see the list of Lenovo Press Product Guides in the Top of rack switches category http www redbooks ibm com portals systemx Open amp page pg amp cat tor Uninterruptible power supply units The server supports attachments to the uninterruptible power supply UPS units that are lis
10. it to the server as a virtual drive The blue screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating system hang condition A system administrator can use the blue screen capture to assist in determining the cause of the hang condition The following table lists the remote management option Table 19 Remote management option Part Feature Description Maximum Models number code supported where used 90Y3901 AIML Integrated Management Module Advanced Upgrade 1 System x3100 M5 22 Supported operating systems The server supports the following operating systems Microsoft Windows Server 2008 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Red Hat Enterprise Linux 5 Server Edition Red Hat Enterprise Linux 5 Server x64 Edition SUSE Enterprise Linux Server SLES 12 SUSE LINUX Enterprise Server 11 for AMD64 EM64T SUSE LINUX Enterprise Server 11 for x86 SUSE Linux Enterprise Server 12 with XEN Toshiba 4690 Operating System V6 VMware vSphere 5 1 ESXi VMware vSphere 5 5 ESXi For the latest information about the specific versions and service levels that are supported and any other prerequisites see the ServerProven website http www ibm com systems info x86servers serverproven compat us nos matrix shtml Physical and electrical specifications Dimensions and weight compact tower systems with a
11. m 5 00 p m in the customer s local time zone Monday through Friday excluding holidays If after 1 00 p m it is determined that onsite service is required the customer can expect the service technician to arrive the morning of the following business day For noncritical service requests a service technician arrives by the end of the following business day 9x5 next business day A service technician is scheduled to arrive at your customer s location on the business day after we receive your call following remote problem determination We provide service from 8 00 a m 5 00 p m in the customer s local time zone Monday through Friday excluding holidays System x3100 M5 25 Regulatory compliance The server conforms to the following international standards ASHRAE A3 FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES003 issue 5 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class A Australia New Zealand AS NZS CISPR 22 Class A AS NZS 60950 1 IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 1 GB9254 Class A and GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia Belorussia and Kazakhstan TR CU 020 2011 for EMC and TR CU004 2011 for safety IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 and EN61000
12. o Minimum configuration 0 035 kVA o Maximum configuration 0 350 kVA 300 watt power supply e 100 127 nominal V ac 50 60 Hz 7 0 A maximum e 200 240 nominal V ac 50 60 Hz 3 5 A maximum e Input kilovolt amperes o Minimum configuration 0 035 kVA o Maximum configuration 0 350 kVA Environmental data e BTU output e Ship configuration 341 Btu hr 100 watts e Full configuration 1726 Btu hr 506 watts e Noise level e Model with fixed power supply 5 0 bels idle 5 0 bels operating e Model with hot swap power supply 5 0 bels idle 5 0 bels operating System x3100 M5 24 Warranty options The x3100 M5 has a 1 year onsite warranty with 9x5 NBD terms Lenovo offers warranty service upgrades through ServicePac offerings The ServicePac is a series of prepackaged warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions ServicePac offerings are country specific Each country might have its own service types service levels response times and terms and conditions Not all covered types of ServicePac offerings might be available in a particular country For more information about ServicePac offerings that are available in your country see the ServicePac Product Selector at https www 304 ibm com sales gss download spst servicepac In general th
13. per port PCle x8 Gen 3 host interface Based on the LSI SAS2208 6 Gbps ROC controller Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures For more information see the Lenovo Press Product Guide ServeRAID M5120 SAS SATA Controller for System x at http www redbooks ibm com abstracts tips0858 html Open The ServeRAID M5120 SAS SATA Controller supports connectivity to the external expansion enclosures that are listed in the following table Up to nine expansion enclosures can be daisy chained per one M5120 external port For better performance distribute expansion enclosures evenly across both M5120 ports Table 22 External expansion enclosures Part number Description Maximum quantity supported per one adapter 610012X EXP2512 Storage Enclosure 17 610024X EXP2524 Storage Enclosure 9 The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS SATA Controller Table 23 External SAS cables for external storage expansion enclosures Part number Feature code Description Quantity supported per one enclosure Cables for use with M5120 controller 39R6531 3707 3 m SAS Cable 1 39R6529 3708 1m SAS Cable 1 Cables for use with M5225 controller 00Y2459 0 6m SAS Cabl
14. product program or service Lenovo may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to Lenovo United States Inc 1009 Think Place Building One Morrisville NC 27560 U S A Attention Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or
15. table lists the external storage systems that are supported by the server and can be ordered through System x sales channel The server may support other disk systems that are not listed in this table For more information see the IBM System Storage Interoperability Center at http www ibm com systems support storage ssic Table 26 External disk storage systems Part number Description 2071CU2 IBM Storwize V3500 LFF Dual Control Enclosure 2071CU3 IBM Storwize V3500 SFF Dual Control Enclosure 6099L2C IBM Storwize V3700 3 5 inch Storage Controller Unit 6099S2C IBM Storwize V3700 2 5 inch Storage Controller Unit 6099T2C IBM Storwize V3700 2 5 inch DC Storage Controller Unit 6194L2C IBM Storwize V5000 LFF Control Enclosure 6194LEU IBM Storwize V5000 LFF Expansion Enclosure 6194S2C IBM Storwize V5000 SFF Control Enclosure 6194SEU IBM Storwize V5000 SFF Expansion Enclosure 6195SC5 IBM Storwize V7000 2 5 inch Storage Controller Unit 6195LEF IBM Storwize V7000 3 5 inch Storage Expansion Unit 6195SEF IBM Storwize V7000 2 5 inch Storage Expansion Unit For more information see the list of Lenovo Press Product Guides in the System Storage category http www redbooks ibm com portals systemx Open amp page pg amp cat externalstorage System x3100 M5 30 External backup units The server supports the external backup attachment options that are listed in th
16. 0T 3 0GHz 3MB 1600MHz 2C 35W A58C Intel Core i3 Processor 4350 3 6GHz 4MB 1600MHz 2C 54W A58B Intel Core i3 Processor 4360 3 7GHz 4MB 1600MHz 2C 54W A58R Intel Pentium Processor G3220 3 0GHz 3MB 1333MHz 2C 53W A58G Intel Pentium Processor G3240 3 1GHz 3MB 1333MHz 2C 53W A58H Intel Pentium Processor G3240T 2 7GHz 3MB 1333MHz 2C 35W A58J Intel Pentium Processor G3440 3 3GHz 3MB 1600MHz 2C 53W A3x A58F Intel Pentium Processor G3450 3 4GHz 3MB 1600MHz 2C 53W A3QT Intel Xeon Processor E3 1220 v3 3 1GHz 8MB 1600MHz 4C 80W B3x EBx ECx EDx EEx EGx EHx A4VZ Intel Xeon Processor E3 1220L v3 1 1GHz 4MB 1600MHz 2C 13W A58K Intel Xeon Processor E3 1231 v3 3 4GHz 8MB 1600MHz 4C 80W C3x C5x EFx A58Q Intel Xeon Processor E3 1240L v3 2 0GHz 8MB 1600MHz 4C 25W A58L Intel Xeon Processor E3 1241 v3 3 5GHz 8MB 1600MHz 4C 80W A58M Intel Xeon Processor E3 1271 v3 3 6GHz 8MB 1600MHz 4C 80W EJx EKx F3x A58P Intel Xeon Processor E3 1275L v3 2 7GHz 8MB 1600MHz 4C 45W A58N Intel Xeon Processor E3 1281 v3 3 7GHz 8MB 1600MHz 4C 82W No additional processor options are available The server supports only one processor which is already included in a standard or custom configuration Processor detail Processor model core speed L3 cache memory speed number of cores and thermal design power TDP rating System x3100 M5 Memory options Lenovo DDR3 memory is compatibil
17. 273 A2MC ServeRAID M5100 Series SSD Performance Key for System x 1 90Y4318 A2MD ServeRAID M5100 Series SSD Caching Enabler for System x 1 A cache option 81Y4484 81Y4487 or 81Y4559 must be selected For the standard tower chassis only hot swap power supplies Not supported in the compact tower chassis System x3100 M5 The following table lists chassis upgrades for RAID controllers Table 11 Chassis upgrades kit supported in the compact tower chassis For the standard tower chassis only hot swap power supplies to provide a housing for a battery or flash backup unit required if the battery upgrade 81Y4508 or a flash upgrade is selected Not Part Feature Description Maximum Models number code supported where used 00J6352 A49A System x3100 3 5 Simple Swap HDD Hardware RAID upgrade kit 1 For the compact tower chassis only fixed power supply to enable support of RAID controllers if selected then one of the following controllers is required ServeRAID M1115 ServeRAID H1110 or N2115 HBA Not supported the standard tower chassis 00J6455 A3SE System x3100 Hardware RAID Remote Battery Cap Mechanical 1 EKx For more information see the list of Lenovo Press Product Guides in the RAID adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat raid Internal backup units The server supports the internal t
18. 3 3 CISPR 22 Class A TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 System x3100 M5 26 External disk storage expansion The x3100 M5 supports attachment to external storage expansion enclosures such as the EXP2500 series by using either the ServeRAID M5225 or ServeRAID M5120 RAID controllers The server can also be attached to supported external storage systems by using a supported HBA Table 21 RAID controllers and options for external disk storage expansion Partnumber Feature Description Maximum code supported 00AE938 A5ND ServeRAID M5225 2GB SAS SATA Controller for System x 1 81Y4478 A1WX ServeRAID M5120 SAS SATA Controller 3 Hardware upgrades for the M5120 81Y4508 A22E ServeRAID M5100 Series Battery Kit T Supported only with 512MB cache option 81Y4484 00J6455 A3SE System x3100 Hardware RAID Remote Battery Cap Mechanical kit 1 81Y4484 A1J3 ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade 3 81Y4487 A1J4 ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade 1 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade 1 Feature on Demand upgrades for the M5120 81Y4544 A1X2 ServeRAID M5100 Series Zero Cache RAID 5 Upgrade 1 90Y4318 A2MD ServeRAID M5100 Series SSD Caching Enabler 1 90Y4273 A2MC ServeRAID M5100 Series SSD Performance Key 1 81Y4546 A1X3 ServeRAID M5100 Series RAID 6 Upgrade it Feature on Demand upgrades for the M5225 4
19. 7C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade for Systems FoD 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator for Systems FoD 1 4708712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler for Systems FoD 1 The ServeRAID M5100 Series Battery Kit 81Y4508 is supported only with ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade 81Y4484 The ServeRAID M5100 Series RAID 6 Upgrade 81Y4546 requires a cache upgrade either 81Y4484 81Y4487 or 81Y4559 For the standard tower chassis only hot swap power supplies Not supported in the compact tower chassis The ServeRAID M5225 2GB SAS SATA Controller has the following specifications Eight external 12 Gbps SAS SATA ports Two external x4 mini SAS HD connectors SFF 8643 Supports RAID levels 0 1 10 5 50 standard Optional support for RAID 6 and 60 with the M5200 Series RAID 6 Upgrade 2 GB flash backed cache standard PCle x8 3 0 host interface Based on the LSI SAS3108 12 Gbps ROC controller System x3100 M5 27 The ServeRAID M5120 SAS SATA Controller has the following specifications Eight external 6 Gbps SAS SATA ports Two external x4 mini SAS connectors SFF 8088 Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade Supports 512 MB battery backed cache or 512 MB or 1 GB flash backed cache 6 Gbps throughput
20. B 1600MHz 4C 80W 1600 MHz C100 fixed 5457 C3x Xeon E3 1231 v3 3 4GHz 1x 4 GB ServeRAID 4x 3 5 SS Open 2x GbE DVD 1x 300W 1 2 8MB 1600MHz 4C 80W 1600 MHz C100 fixed Standard tower form factor hot swap drives and power supplies 5457 C5x Xeon E3 1231 v3 3 4GHz 1x 4 GB ServeRAID 4x 3 5 HS Open 2x GbE Multi 1x 430W 2 2 8MB 1600MHz 4C 80W 1600 MHz H1110 burner hot swap 5457 F3x Xeon E3 1271 v3 3 6GHz 1x 4 GB ServeRAID 8x 2 5 HS Open 2x GbE Multi 1x 430W 2 2 8MB 1600MHz 4C 80W 1600 MHz M1115 burner hot swap Processor detail Processor quantity processor model core speed number of cores L3 cache memory speed and thermal design power TDP rating System x3100 M5 Express models Express models are preconfigured with additional components such as processors memory and disks with the purpose of making the ordering and installation process simpler The following table lists the Express models that are available in certain regions Table 3 Express models Model Intel Processor Memory RAID Disk Disks Network Optical Power Fans one maximum controller bays supply Compact tower form factor simple swap drives and fixed power supply 5457 Core i3 4150 3 5GHz 1x 4
21. C This means potential savings in environmental cooling costs e The Intel Xeon processor E3 1200 v3 product family offers significantly better performance over the previous generation while fitting into the same thermal design power TDP limits e Low voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments e The server uses hexagonal ventilation holes a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system System x3100 M5 3 Locations of key components The x3100 M5 is available in two different tower designs a compact tower with a fixed power supply and simple swap drive bays or a standard tower with hot swap power supplies and hot swap drive bays Figures 2 and 3 show the front and rear of the x3100 M5 Power button and status LEDs Optical drive Available Reserved 5 bay gt bay USB 3 0 ports 8x 2 5 inch hot swap 4x 3 5 inch drive bays simple swap or HDD bays 4x 3 5 inch hot swap HDD bays Models with a fixed Models with hot swap power supply power supplies 2x hot swap redundant power supplies N Fixed power supply Serial port Serial port W f Video port Video port R 4x USB 2 0 4 ji 2x Ethernet ports 4x USB 2 0 i one shared with IMM2 Loop for cover lock cover lock 4
22. D ROM supports the following media and speeds for reading CD ROM 48X CD DA DAE 40X CD R 48X CD RW 40X DVD ROM single layer 16X DVD ROM dual layer 12X DVD R 4 7 GB 16X DVD R DL 12X DVD R 16X DVD R DL 12X DVD RW 4 7 GB 12X DVD RW 12X DVD RAM 4 7 9 4 GB 6X The Half High SATA Multi Burner supports the same media and speeds for reading as HH DVD ROM In addition this drive supports the following media and speeds for writing CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed CD RW 16X DVD R 8X DVD R DL 8X DVD R 8X DVD R DL 8X DVD RW 6X DVD RW 8X DVD RAM 3X I O expansion options The server offers four PCI Express expansion slots The form factors of available slots are as follows This applies to both the compact tower chassis and the standard tower chassis Slot 1 PCle 3 0 x16 x8 wired full height half length Slot 2 PCle 3 0 x8 x8 wired full height half length Slot 3 PCle 2 0 x8 x4 wired full height half length Slot 4 PCle 2 0 x4 x1 wired full height half length System x3100 M5 Network ada The x3100 M5 offers two integrated Gigabit Ethernet ports One port is shared with Integrated pters Management Module II IMM2 implementing Network Controller Sideband Interface NC SI The integrated NICs have the following features Broadcom BCM5717 chip TCP IP Offload Engine TOE support Wake on LAN support Jumbo frame support Receive side Scaling RSS and Transmit s
23. HS Open 2x GbE Multi 1x 430W 2 2 EJx 8MB 1600MHz 4C 80W 1600 MHz M1115 burner hot swap 5457 Xeon E3 1271 v3 3 6GHz 2x 8 GB ServeRAID 8x 2 5 HS Open 2x GbE Multi 2x 430W 2 2 EKx 8MB 1600MHz 4C 80W 1600 MHz M5110t burner hot swap Processor detail Processor quantity processor model core speed number of cores L3 cache memory speed and thermal design power TDP rating t Model EKx includes ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade for System x 81Y4487 and System x3100 Hardware RAID Remote Battery Cap Mechanical kit 00J6455 System x3100 M5 9 Processor options The server supports only one processor which is already installed in all standard and Express models No additional processor options are available The following table lists all processors that are available in standard models of x3100 M5 or through configure to order CTO If there is no corresponding where used model for a particular processor then that processor is only available through the CTO process or special bid Table 4 Processor options Feature Description Standard models code where used A58S Intel Celeron Processor G1840 2 8GHz 2MB 1333MHz 2C 53W A58D Intel Core i3 Processor 4150 3 5GHz 3MB 1600MHz 2C 54W EAx A58E Intel Core i3 Processor 415
24. S77 4TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e HDD 4 00ML213 AS78 6TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e HDD 4 3 5 inch NL SAS self encyrping drives SEDs 512e Advanced Format drives 00ML218 AS79 2TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e SED 4 00ML223 AS7A 4TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e SED 4 00ML228 AS7B 6TB 7 2K 6Gbps NL SAS 3 5 G2HS 512e SED 4 System x3100 M5 Controllers for internal storage The Integrated ServeRAID C100 disk controller offers RAID 0 1 and 10 standard The ServeRAID C100 is an integrated SATA controller with software RAID capabilities It is a cost effective way to provide reliability performance and fault tolerant disk subsystem management to help safeguard your valuable data and enhance availability The ServeRAID C100 has the following specifications Supports RAID levels 0 1 and 10 Onboard SATA controller with software RAID capabilities Supports 3 Gbps SATA ports Support for up to two virtual drives Support for virtual drive sizes greater than 2 TB Fixed stripe unit size of 64 KB Support for MegaRAID Storage Manager management software The following table lists the RAID controller and internal HBAs that are supported by the server Table 9 RAID controllers and HBAs for internal storage Partnumber Feature Description Maximum Standard models code supported where used Integrated None ServeRAID C100 for System x 1 All other models
25. ape drive options that are listed in the following table Internal tape drives are installed in a 5 25 inch HH bay A maximum of one tape drive is supported SAS tape drives require an internal SAS HBA to be installed in server USB tape drives are connected to the dedicated USB tape drive connector on the system board Table 12 Internal tape drives Part Feature Description number code Maximum supported 49Y9898 5345 Half High LTO Gen 5 SAS Tape Drive 1 00D2786 A2VE RDX Internal USB 3 0 Dock with 320GB Cartridge 1 00D2787 A2VF RDX Internal USB 3 0 Dock with 500GB Cartridge 1 00D2788 A2VG RDX Internal USB 3 0 Dock with 1TB Cartridge 1 Requires N2115 SAS SATA HBA for System x 46C8988 or 6Gb SAS HBA 46M0907 For more information see the list of Lenovo Press Product Guides in the Backup units category http www redbooks ibm com portals systemx Open amp page pg amp cat tape System x3100 M5 Optical drives The server supports the optical drive options that are listed in the following table Table 13 Optical drives Part number Feature Description Maximum Standard models code supported where used None 4154 Half High SATA DVD ROM 1 A3x B3x C3x EAx 81Y6404 4155 Half High SATA Multi Burner 1 All other models This option is only available through CTO or is already installed in standard models The Half High SATA DV
26. ber Feature Description Maximum code supported 2 5 inch 10K SAS HDDs 90Y8877 A2XC 300GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 8 90Y8872 A2XD 600GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 8 81Y9650 A282 900GB 10K 6Gbps SAS 2 5 SFF HS HDD 8 2 5 inch 15K SAS HDDs 90Y8926 A2XB 146GB 15K 6Gbps SAS 2 5 SFF G2HS HDD 8 81Y9670 A283 300GB 15K 6Gbps SAS 2 5 G2HS HDD 8 2 5 inch SAS self encrypting drives SEDs 90Y8908 A3EF 600GB 10K 6Gbps SAS 2 5 SFF G2HS SED 8 81Y9662 A3EG 900GB 10K 6Gbps SAS 2 5 SFF G2HS SED 8 2 5 inch NL SAS HDDs 90Y8953 A2XE 500GB 7 2K 6Gbps NL SAS 2 5 SFF G2HS HDD 8 81Y9690 A1P3 1TB 7 2K 6Gbps NL SAS 2 5 SFF HS HDD 8 2 5 inch NL SATA HDDs 81Y9722 A1NX 250GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 81Y9726 A1NZ 500GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 81Y9730 A1AV 1TB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 2 5 inch Enterprise Value SSDs OOFN298 ASOD 240GB SATA 2 5 MLC HS Entry SSD 8 00FN327 ASOE 480GB SATA 2 5 MLC HS Entry SSD 8 00FN332 ASOF 960GB SATA 2 5 MLC HS Entry SSD 8 OOFN268 A5U4 3500 1 6TB SATA 2 5 MLC HS Enterprise Value SSD 8 2 5 inch Enterprise SSDs 41Y8331 A4FL 3700 200GB SATA 2 5 MLC HS Enterprise SSD for System x 8 41Y8336 A4FN 3700 400GB SATA 2 5 MLC HS Enterprise SSD for System x 8 41Y8341 A4FQ 3700 800GB SATA 2 5 MLC HS Enterprise SSD for System x 8 49Y6129 A3EW
27. btype ca amp amp htmlfid 89 7 ENUS 1 14 047 Lenovo Press Product Guides for System x options http www redbooks ibm com portals systemx Open amp page pgbycat System x3100 M5 product page http www ibm com systems x hardware tower x3100m5 System x3100 M5 Installation and Service Guide http ibm com support System x Information Center http publib boulder ibm com infocenter systemx documentation ServerProven hardware compatibility page for the x3100 M5 http www ibm com systems info x86servers serverproven compat us xseries 5457 html Configuration and Option Guide http www ibm com systems xbc cog xREF System x Reference http www redbooks ibm com xref System x Support Portal http ibm com support entry portal http ibm com support entry portal Downloads Hardware Systems System_x System_x3100_M5 System x3100 M5 38 Notices Lenovo may not offer the products services or features discussed in this document in all countries Consult your local Lenovo representative for information on the products and services currently available in your area Any reference to a Lenovo product program or service is not intended to state or imply that only that Lenovo product program or service may be used Any functionally equivalent product program or service that does not infringe any Lenovo intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any other
28. drive bays One 5 25 HH bay support for DVD ROM or multiburner Half High SATA DVD ROM or multiburner included in standard models model specific Tape drive bays One 5 25 HH bay support for DDS RDX or LTO drive Network interfaces Integrated two port Gigabit Ethernet Broadcom BCM5717 One port is shared with the Integrated Management Module IMM PCI expansion slots Four PCI Express slots Slot 1 PCle 3 0 x16 x8 wired full height half length Slot 2 PCle 3 0 x8 x8 wired full height half length Slot 2 PCle 2 0 x8 x4 wired full height half length Slot 4 PCle 2 0 x4 x1 wired full height half length System x3100 M5 Table 1 Standard specifications part 2 of 2 Components Specification Ports Front Two USB 3 0 ports Rear Four USB 2 0 one DB 15 video one DB 9 serial two RJ 45 Gigabit Ethernet network ports one dedicated and one shared with the IMM2 management processor nternal One USB 2 0 port for internal USB tape drive Cooling Compact tower Up to two speed controlled non redundant fans A second fan is required if two or more adapters are installed Thermal Solution Fan kit 46W9177 optional Optional Operating Temperature Enhancement Kit 00Y8197 to enable the server to operate in a 40 C environment Standard tower Up to two speed controlled non redundant fans A second
29. ds 41Y8385 A584 USB Memory Key for VMware ESXi 5 5 1 Remote management The server contains Integrated Management Module II IMM2 which provides advanced service processor control monitoring and an alerting function If an environmental condition exceeds a threshold or if a system component fails the IMM2 lights LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem Optionally the IMM2 also provides a virtual presence capability for remote server management capabilities The IMM provides remote server management through industry standard interfaces Intelligent Platform Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue screen capture features The remote presence feature provides the following functions e Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors regardless of the system state e Remotely accessing the server using the keyboard and mouse from a remote client e Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server e Uploading a diskette image to the IMM memory and mapping
30. e mSAS HD to mSAS 1 00Y2461 1 5m SAS Cable mSAS HD to mSAS 1 00Y2463 3m SAS Cable mSAS HD to mSAS 1 90Y7682 6m SAS Cable mSAS HD to mSAS 1 System x3100 M5 28 The following table lists the drives that are supported by EXP2512 external expansion enclosures Table 24 Drive options for EXP2512 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 3 5 NL SAS HS HDDs OONC555 2TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00NC557 3TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00NC559 4TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures Table 25 Drive options for EXP2524 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 2 5 NL SAS HS HDDs 00NC571 1TB 7 200 rpm 6Gb SAS NL 2 5 HDD 24 2 5 SAS HS HDDs OONC561 146GB 15 000 rpm 6Gb SAS 2 5 HDD 24 OONC563 300GB 15 000 rpm 6Gb SAS 2 5 HDD 24 OONC565 600GB 10 000 rpm 6Gb SAS 2 5 HDD 24 OONC567 900GB 10 000 rpm 6Gb SAS 2 5 HDD 24 OONC569 1 2TB 10 000 rpm 6Gb SAS 2 5 HDD 24 2 5 SAS HS SSDs 00NC573 200GB 6Gb SAS 2 5 SSD 24 00NC575 400GB 6Gb SAS 2 5 SSD 24 System x3100 M5 29 External disk storage systems The following
31. e Intel Xeon Processor E3 1200 v3 family supports Intel Hyper Threading Technology and Intel Turbo Boost Technology 2 0 to maximize performance e Up to 32 GB of high speed DDR3 system memory with four DIMM sockets e Memory speeds up to 1600 MHz e Four available high performance PCI Express 3 0 or 2 0 slots e Up to four internal 3 5 inch simple swap or hot swap SATA II HDDs on some models offer low cost high capacity storage e Up to eight internal 2 5 inch hot swap SAS SATA HDDs on some models offers maximum scalability and performance e Integrated ServeRAID C100 software RAID controller supports RAID 0 1 and 10 Hardware RAID options are available e Integrated dual port Gigabit Ethernet provides increased network throughput and redundancy with efficient slot saving integration e Anavailable 5 25 inch drive bay supports either a half high tape drive or an RDX Removable Disk Cartridge drive for cost effective data backup A DVD ROM drive is standard in a dedicated bay e Seven USB ports two USB 3 0 on the front and four USB 2 0 on the back In addition there is one internal port for use with a tape drive or RDX Removable Disk Cartridge drive Availability and serviceability The x3100 M5 provides many features to simplify serviceability and increase system uptime e ECC memory provides error correction that is not available in PC class servers that use parity memory Avoiding system crashes and data loss because of soft
32. e following table Table 27 External backup options Part number Description External tape expansion enclosures for internal tape drives 87651UX 1U Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure with Nema 5 15P LineCord Tape enclosure adapters with cables 44E8869 USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 00D2786 RDX Internal USB 3 0 Dock with 320GB Cartridge 00D2787 RDX Internal USB 3 0 Dock with 500GB Cartridge 00D2788 RDX Internal USB 3 0 Dock with 1TB Cartridge 49Y9898 Half High LTO Gen 5 Internal SAS Tape Drive 00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive External backup units 362532Y RDX External USB 3 0 Dock with 320GB Cartridge 362550Y RDX External USB 3 0 Dock with 500GB Cartridge 36251TY RDX External USB 3 0 Dock with 1TB Cartridge 3628L5X Half High LTO Gen 5 External SAS Tape Drive with US line cord 3628N5X Half High LTO Gen 5 External SAS Tape Drive without line cord These external tape drives can be ordered through the System x sales channel The server might support other tape drives that are not listed in this table See the IBM System Storage Interoperation Center SSIC for further information For more information see the list of Lenovo Press Product Guides
33. e types of ServicePac offerings are e Warranty and maintenance service upgrades e One 2 3 4 or 5 years of 9x5 or 24x7 service coverage e Onsite repair from next business day to 4 or 2 hours selected areas e One or two years of warranty extension e Remote technical support services One or three years with 24x7 coverage severity 1 or 9x5 NBD for all severities Installation and startup support for System x servers Remote technical support for System x servers Software support Support Line e Microsoft or Linux software e VMware e IBM Systems Director The following table explains warranty service definitions in more detail Table 20 Warranty service definitions Term Description Onsite repair A service technician comes to the server s location for equipment repair 24x7x2 hour A service technician is scheduled to arrive at your customer s location within two hours after remote problem determination is completed We provide service around the clock every day including holidays 24x7x4 hour A service technician is scheduled to arrive at your customer s location within four hours after remote problem determination is completed We provide service around the clock every day including holidays 9x5x4 hour A service technician is scheduled to arrive at your customer s location within four business hours after remote problem determination is completed We provide service from 8 00 a
34. es available through ServicePac offerings 24x7 NBD or four hours onsite repair 1 year or 2 year warranty extension remote technical support for Lenovo hardware and selected Lenovo and third party Microsoft Linux VMware software Dimensions Compact tower Height 360 mm 14 2 width 180 mm 7 1 depth 480 mm 18 9 Standard tower Height 439 mm 17 3 width 217 mm 8 6 depth 569 mm 22 4 Weight Compact tower Minimum configuration 10 kg 22 0 Ib maximum 13 kg 28 7 Ib Standard tower Minimum configuration 19 6 kg 43 Ib maximum 22 kg 48 5 Ib The x3100 M5 servers are shipped with the following items Important Notices System x3100 M5 Statement of Limited Warranty Documentation CD that contains the nstallation and Service Guide Country specific models might have one or two country specific power cords Standard models The following table lists the standard models Table 2 Standard models Model Intel Processor Memory RAID Disk Disks Network Optical Power Fans one maximum controller bays supply Compact tower form factor simple swap drives and fixed power supply 5457 A3x_ Pentium G3440 3 3GHz 1x 4 GB ServeRAID 4x 3 5 SS Open 2x GbE DVD 1x 350W 1 2 3MB 1600MHz 2C 54W 1600 MHz C100 fixed 5457 B3x Xeon E3 1220 v3 3 1GHz 1x 4 GB ServeRAID 4x 3 5 SS Open 2x GbE DVD 1x 350W 1 2 8M
35. fan is required if two or more adapters are installed Thermal Solution Fan kit 00Y8200 included in standard models Optional Operating Temperature Enhancement Kit 00FK940 to enable the server to operate in a 40 C environment Power supply Compact tower One fixed non hot swap power supply model dependent Either 300 W ac 80 PLUS Bronze power supply or 350 W ac power supply Standard tower Up to two 430 W hot swap 80 PLUS Silver redundant power supplies Hot swap parts Compact tower None Standard tower Disk drive bays and power supplies Systems management UEFI Integrated Management Module II IMM2 basic light path diagnostic tests Automatic Server Restart IBM Systems Director and ServerGuide Optional IMM Advanced FoD Upgrade for remote presence graphics keyboard and mouse and virtual media Video Matrox G200eR2 with 16 MB memory that is integrated into the IMM2 Maximum resolution is 1600x1200 at 75 Hz with 16 M colors Security features Power on password administrator password and Trusted Platform Module Operating systems supported Microsoft Windows Server 2008 R2 2012 2012 R2 RHEL 5 SLES 11 amp 12 VMware ESX 5 1 5 5 no USB 3 0 support for RHEL 5 1 or VMware ESX 5 1 5 5 Limited warranty One year customer replaceable unit and onsite limited warranty with 9x5 next business day NBD response time Service and support Optional service upgrad
36. ide Scaling TSS support MSI and MSI X capability up to five MSI X vectors VLAN tag support IEEE 802 1Q Layer 2 priority encoding IEEE 802 1p Link aggregation IEEE 802 3ad and Full duplex flow control IEEE 802 3x IP TCP and UDP checksum offload hardware based on Tx Rx over IPv4 IPv6 Hardware TCP segmentation offload over IPv4 IPv6 NIC Teaming Load Balancing and Failover The following table lists additional supported network adapters Table 14 Network adapters Part number Feature Description Maximum code supported Gigabit Ethernet 90Y9370 A2V4 Broadcom NetXtreme Dual Port GbE Adapter for System x 2 90Y9352 A2V3 Broadcom NetXtreme Quad Port GbE Adapter for System x 3 49Y4230 5767 Intel Ethernet Dual Port Server Adapter 1340 T2 for System x 3 49Y4240 5768 Intel Ethernet Quad Port Server Adapter I340 T4 for System x 3 00AG500 A56K Intel 1350 F 1 1xGbE Fiber Adapter for System x 4 00AG510 ADS6L Intel 1350 T2 2xGbE BaseT Adapter for System x 4 00AG520 A56M Intel 1350 T4 4xGbE BaseT Adapter for System x 4 4201750 2975 PRO 1000 PF Server Adapter 3 10 Gigabit Ethernet 49Y7910 A18Y Broadcom NetXtreme II Dual Port 1OGBaseT Adapter for System x 3 00D8540 A4XH Emulex Dual Port 10GbE SFP VFA Illr for System x 3 95Y3760 A2U2 Emulex VFA III IIlr FCoE iSCSI License for System x FoD 3 FCoE upgrade license f
37. implied license or indemnity under the intellectual property rights of Lenovo or third parties All information contained in this document was obtained in specific environments and is presented as an illustration The result obtained in other operating environments may vary Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Any references in this publication to non Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this Lenovo product and use of those Web sites is at your own risk Any performance data contained herein was determined in a controlled environment Therefore the result obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurements may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment Copyright Lenovo 2014 2015 All rights reserved System x3100 M5 39 This document was created or updated on February 2 2015 Send us your comments in one of the following ways e Use the online Contact us review form found at ib
38. ity tested and tuned for optimal System x performance and throughput Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime From a service and support standpoint Lenovo memory automatically assumes the system warranty and Lenovo provides service and support worldwide The x3100 M5 has four DIMM slots and only DDR3 ECC UDIMMs are supported The CPU has two memory channels and there are two DIMMs per channel Configuration rules If you plan to install more than one DIMM then the DIMMs must be installed in a pair and both DIMMs in a pair must be identical in type and size The following table lists the memory options that are supported by the server Table 5 Memory options Part Feature Description Maximum Standard models number code supported where used 00D5012 A3QB 4GB 1x4GB 2Rx8 1 35V PC3L 12800 4 A3x B3x C3x CL11 ECC DDR3 1600MHz LP UDIMM C5x EAx F3x 00D5016 A3QC 8GB 1x8GB 2Rx8 1 35V PC3L 12800 4 All other models CL11 ECC DDR3 1600MHz LP UDIMM Internal drives Models of the x3100 M5 with the compact tower form factor and either a 300 W or a 350 W fixed power supply support up to four 3 5 inch simple swap SATA hard disk drives as shown in the following figure Figure 6 Simple swap drive bays of the compact tower models accessible with the front bezel removed Sy
39. lenovo i THOSE fa System x3100 M5 Lenovo Press Product Guide The System x3100 M5 single socket tower server is designed for small businesses and first time server buyers looking for a solution to improve business efficiency It delivers several innovative features with a competitive price either in a compact mini tower form factor or standard tower form factor with hot swap power supplies and disk drives The System x3100 M5 provides next generation performance in an innovative and compact design with flexible configuration options built in security and systems management capabilities It leverages the next generation dual core and quad core Intel Xeon processor technology Suggested uses Retail kiosks and SMBs looking for file and printer servers web serving small business infrastructure and virtual desktops for small workgroups Figure 1 The System x3100 M5 compact mini tower shown Did you know The System x3100 M5 server is a compact cost effective single processor tower or rack mountable server that has been optimized to provide outstanding availability manageability and performance features to small to medium sized businesses retail stores or distributed enterprises It supports the Intel Xeon E3 1200 v3 Haswell family of processors for applications that require performance and stability and Core i3 Pentium and Celeron processors for applications that require lower cost The system includes features that
40. m com redbooks e Send your comments in an e mail to redbooks us ibm com This document is available online at http www ibm com redbooks absiracts tips1165 html Trademarks Lenovo For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States other countries or both These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol or indicating US registered or common law trademarks owned by Lenovo at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Lenovo RackSwitch Lenovo logo ServeRAID ServerGuide ServerProven System x The following terms are trademarks of other companies Celeron Intel Intel Xeon Pentium Intel logo Intel Inside logo and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft Windows and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Other company produc
41. memory errors can mean greater system uptime e Tool less cover removal provides easy access to upgrades and serviceable parts such as CPU memory and adapters e Hot swap drive bays that are available on some models combined with RAID capabilities offer the potential of no downtime in the event of a drive failure System x3100 M5 e The Predictive Failure Analysis PFA detects when system components for example processors memory and hard disk drives operate outside of standard thresholds and generates pro active alerts in advance of possible failure therefore increasing uptime e Built in Integrated Management Module Version II IMM2 continuously monitors system health triggers alerts and performs recovering actions in case of failures to minimize downtime e Built in diagnostic tests using Dynamic Systems Analysis DSA Preboot speeds up troubleshooting tasks to reduce service time e ADVD ROM drive is standard in a dedicated bay for easy software installation e Redundant hot swap power supports on some models helps keep the server always running e One year customer replaceable unit and onsite limited warranty next business day 9x5 Optional service upgrades are available Manageability and security Powerful systems management features simplify local and remote management of the x3100 M5 e The server includes an Integrated Management Module II IMM2 to monitor server availability and perform remote management some feat
42. or 00D8540 49Y7960 A2EC Intel X520 Dual Port 10GbE SFP Adapter for System x 3 49Y7970 A2ED Intel X540 T2 Dual Port 10GBaseT Adapter for System x 3 00D9690 A3PM Mellanox ConnectX 3 10 GbE Adapter for System x 3 90Y4600 A3MR QLogic 8200 Dual Port 10GbE SFP VFA for System x 3 00Y5624 A3MT QLogic 8200 VFA FCoE iSCSI License for System x FoD 3 FCoE upgrade license for 90Y4600 Require SFP optical transceivers or DAC cables that must be purchased separately System x3100 M5 19 For more information see the list of Lenovo Press Product Guides in the Networking adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat networkadapters Storage host bus adapters The following table lists the storage host bus adapters HBAs supported by x3100 M5 server Table 15 Storage adapters Part number Feature Description Maximum code supported Fibre Channel 16 Gb 81Y1655 A2W5 Emulex 16Gb FC Single port HBA for System x 3 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA for System x 3 81Y1668 A2XU Brocade 16Gb FC Single port HBA for System x 3 81Y1675 A2XV Brocade 16Gb FC Dual port HBA for System x 3 00Y3337 A3KW QLogic 16Gb FC Single port HBA for System x 3 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for System x 3 Fibre Channel 8 Gb 42D0485 3580 Emulex 8 Gb FC Single port HBA for System x 3 42D0494 3581 Emulex 8 Gb FC Dual p
43. ort HBA for System x 3 42D0501 3578 QLogic 8 Gb FC Single port HBA for System x 3 42D0510 3579 QLogic 8 Gb FC Dual port HBA for System x 3 46M6049 3589 Brocade 8 Gb FC Single port HBA for System x 3 46M6050 3591 Brocade 8 Gb FC Dual port HBA for System x 3 SAS 46C9010 A3MV N2125 SAS SATA HBA for System x 3 46M0907 5982 6 Gb SAS HBA Controller 3 For more information see the list of Lenovo Press Product Guides in the Host bus adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat hba PCle SSD adapters The server does not support High IOPS SSD adapters System x3100 M5 Power supplies Compact tower models either come with a single fixed 350 W ac power supply or a single fixed 80 PLUS Bronze 300 W ac power supply There are no additional power supply options Standard tower models offer one or two hot swap 430 W ac power supplies which are 80 PLUS Silver certified For models with only one power supply the part number to order a second power supply is listed in the following table Two power supplies that are installed form a redundant pair Table 16 Hot swap power supply option Part number Feature Description Maximum code supported 00D3821 A2Z0 430W Redundant Power Supply 1 Fans and cooling Both the compact tower design with a single fixed power supply and the standard t
44. ower design with hot swap power supplies come with one or two speed controlled non redundant fans model dependent see Table 2 The second fan is required if two or more adapters are installed and the fan is configured by selecting the appropriate Thermal Solution Fan Kit as listed in the following table If you want to operate the server in an environment up to 40 C 104 F use the optional Operating Temperature Enhancement Kit that is listed in the table This kit contains an additional thermal sensor Table 17 Cooling options Part number Feature Description Maximum code supported For compact tower systems with a fixed power supply 46W9177 A3SF System x3100 Thermal Solution Fan kit for 4U 1 Tower 00Y8197 A49B System x3100 Operating Temperature 1 Enhancement Kit for 4U Tower For standard tower systems with hot swap power supplies 00Y8200 A49D System x3100 Thermal Solution Fan kit for 5U 1 Tower OOFK940 A49C System x3100 Operating Temperature 1 Enhancement Kit for 5U Tower System x3100 M5 21 Integrated virtualization The server supports VMware ESXi installed on a USB memory key The key is installed in a USB socket inside the server The following table lists the virtualization options Table 18 Hot swap power supply option Part number Feature Description Maximum code supported 41Y8298 A2G0 Blank USB Memory Key for VMware ESXi 1 Downloa
45. re category http www redbooks ibm com portals systemx Open amp page pg amp cat power System x3100 M5 Racks cabinets The server supports the rack cabinets that are listed in the following table One of the tower to rack conversion kits is required for the server to be installed in the rack Table 31 Rack cabinets Part number Description 00J6353 Tower to 5U Rack Conversion Kit for System x3100 M5 for systems with hot swap power supplies 69Y5182 Tower to 4U Rack Conversion Kit for System x3100 M5 for systems with fixed power supplies 93072PX 25U Static S2 Standard Rack 93072RX 25U Standard Rack 93074RX 42U Standard Rack 93074XX 42U Standard Rack Extension 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 93604EX 42U 1200 mm Deep Dynamic Expansion Rack 93604PX 42U 1200 mm Deep Dynamic Rack 93614EX 42U 1200 mm Deep Static Expansion Rack 93614PX 42U 1200 mm Deep Static Rack 93624EX 47U 1200 mm Deep Static Expansion Rack 93624PX 47U 1200 mm Deep Static Rack For more information see the list of Lenovo Press Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack System x3100 M5 36 Rack options The server supports the rack console switches and monitor kits that are listed in the following table Table 32 Rack options
46. stem x3100 M5 The following table lists the supported 3 5 inch hard disk drive options For information about 512e Advanced Format drives see the Lenovo Press paper Advanced Format HDD Technology Overview available from http www redbooks ibm com abstracts redp5119 html Open Table 6 Simple swap 3 5 inch SATA disk drive options Part number Feature Description Maximum code supported 512e Advanced Format drives OOFN118 ASVE 2TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 00FN133 A5VG 3TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 512 byte sector drives 81Y9802 A22U 500GB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9806 A22X 1TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9810 A22W 2TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9814 A22V 3TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 Models of the x3100 M5 using the standard tower chassis and with hot swap 430 W power supplies support either up to eight 2 5 inch hot swap drives or four 3 5 inch hot swap drives as shown in the following figure Figure 7 Hot swap drives that are supported in standard tower models with hot swap power supplies front bezel removed 4x 3 5 inch left or 8x 2 5 inch right System x3100 M5 12 The following table lists the supported 2 5 inch drive options Hot swap SATA HDDs and hot swap SAS HDDs can be intermixed but not in the same array Table 7 2 5 inch hot swap disk drive options Part num
47. t or service names may be trademarks or service marks of others System x3100 M5 40
48. ted in the following table Table 29 Uninterruptible power supply units Part number Description Rack mounted or tower UPS units 55941AX RT1 5kVA 2U Rack or Tower UPS 100 125VAC 55941KX RT1 5kVA 2U Rack or Tower UPS 200 240VAC 55942AX RT2 2kVA 2U Rack or Tower UPS 100 125VAC 55942KX RT2 2kVA 2U Rack or Tower UPS 200 240VAC 55943AX RT3kVA 2U Rack or Tower UPS 100 125VAC 55943KX RT3kVA 2U Rack or Tower UPS 200 240VAC 55945KX RT5kVA 3U Rack or Tower UPS 200 240VAC 55946KX RT6kVA 3U Rack or Tower UPS 200 240VAC 55948KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55948PX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Rack mounted UPS units 53951AX 1500VA LCD 2U Rack UPS 100V 120V 53951KX 1500VA LCD 2U Rack UPS 230V 53952AX 2200VA LCD 2U Rack UPS 100V 120V 53952KX 2200VA LCD 2U Rack UPS 230V 53953AX 3000VA LCD 3U Rack UPS 100 V 120 V 53953JX 3000VA LCD 3U Rack UPS 200 V 208 V 53956AX 6000VA LCD 4U Rack UPS 200 V 208 V 53956KX 6000VA LCD 4U Rack UPS 230 V 53959KX 11000VA LCD 5U Rack UPS 200V 208V 230V For more information see the list of Lenovo Press Product Guides in the Power infrastructure category http www redbooks ibm com portals s
49. ures require optional license upgrades e Integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error handling e Integrated Trusted Platform Module TPM 1 2 support enables advanced cryptographic functions such as digital signatures and remote attestation e Intel Xeon Processor E3 1200 v3 family supports Industry standard Advanced Encryption Standard AES NI support for faster stronger encryption e IBM Systems Director is included for proactive systems management It offers comprehensive systems management tools that help to increase up time reduce costs and improve productivity through advanced server management capabilities e The Intel Execute Disable Bit function can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system Energy efficiency The x3100 M5 offers the following energy efficiency features to save energy reduce operational costs increase energy availability and contribute to a green environment e Energy efficient planar components help lower operational costs e Available 350 W power supply 300 W 80 PLUS Bronze certified power supply or 430 W hot swap 80 PLUS Silver certified power supply e With the addition of the Operating Temperature Enhancement Kit the server supports the ASHRAE A3 standard which means the server can operate in temperatures as high as 40
50. x PCle slots a Models with a fixed Models with hot swap power supply power supplies Figure 3 Rear view of the System x3100 M5 compact tower and standard tower System x3100 M5 Figures 4 and 5 show the locations of key components inside the server Optical drive Single fixed s power supply p gt 4x DIMM slots Intel Xeon processor 4x PCle slots One or two hot swap power supplies 4x DIMM slots Intel Xeon processor 4x PCle slots 4x 3 5 inch hot swap HDD bays or 8x 2 5 inch hot swap HDD SSD bays Figure 5 Inside view of System x3100 M5 standard tower configuration System x3100 M5 Standard specifications The following table lists the standard specifications Table 1 Standard specifications part 1 of 2 Components Specification Form factor Two designs e Compact tower can be a 4U rack form factor using the optional Tower to Rack Conversion Kit 69Y5182 e Standard Tower can be a 5U rack form factor using the optional Tower to Rack Conversion Kit 00J6353 Processor One Intel Haswell processor as listed in model table or available CTO e One 2 core Intel Celeron Processor 2 8 GHz and 1333 MHz memory e One 2 core Intel Pentium Processor up to 3 4 GHz and 1600 MHz memory e One 2 core Intel Core i3 Processor up to 3 7 GHz and 1600 MHz memory e One 2 or 4 core Intel Xeon E3 1200 v3 up to 3 7 GHz amp 1600 MHz memory Supports EM64T for 32 bit and 64
51. ystemx Open amp page pg amp cat power System x3100 M5 33 Power distribution units The server supports attachments to the power distribution units PDUs that are listed in the following table Table 30 Power distribution units part 1 of 2 Part number Description Switched and Monitored PDUs 46M4002 1U 9 C19 3 C13 Active Energy Manager DPI PDU 46M4003 1U 9 C19 3 C13 Active Energy Manager 60A 3 Phase PDU 46M4004 1U 12 C13 Active Energy Manager DPI PDU 46M4005 1U 12 C13 Active Energy Manager 60A 3 Phase PDU 46M4167 1U 9 C19 3 C13 Switched and Monitored 30A 3 Phase PDU 46M4116 OU 24 C13 Switched and Monitored 30A PDU 46M4119 OU 24 C13 Switched and Monitored 32A PDU 46M4134 OU 12 C19 12 C13 Switched and Monitored 50A 3 Phase PDU 46M4137 OU 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ultra Density Enterprise PDU C19 PDU WW 71763MU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 71763NU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 39M2816 DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P G 208 V fixed power cord 39Y8941 DPI Single Phase C13 Enterprise PDU without power cord 39Y8948 DPI Single Phase C19 Enterprise PDU without power cord Front End PDUs
Download Pdf Manuals
Related Search
Related Contents
Location salle des fêtes de DAMPIERRE (39700) Digital IDview - InfoMedia Electronic Systems Sony VAIO VPCF11GGX/B notebook Audiovox 128-8117 Automobile Alarm User Manual HYDRAULIC BENDER PIPES 16 T Fiche Technique M9.0 System Administration IBM System x 3550 M4 ZTE T60 telstra qwerty touch unlocked gsm phone Programmer User Guide Programmer Guide Copyright © All rights reserved.