Home
Fte maximal TSF 310
Contents
1. Add Services 1 Select the option Add services through Up Down buttons Press OK to continue 2 Select one of the transponder services you want to add through Left Right keys and select the Add button to include the service in the multiplex 3 A window will appear and it will let you know that the operation made has been correct Delete Services 1 Select the option Delete services through Up Down buttons Press OK to continue 2 Select the service you want to delete with the Left Right keys Then press OK over Rem in order to remove it or press OK over All in order to delete all the services of the multiplex 3 A window will appear and it will let you know that the operation made has been correct Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible variability of the bits rate of the inputs services Date Hour Setting of the date and time of transmodulator It is appropriate to maintain these parameters set in order to have the registration of errors linked to the current time and date SW version info It allows you to visualize the basic information of the module model firmware version etc Global Update It allows carrying out the update of all the modules that are interconnected at the same time LCN The LNC function allows assigning automatically a predetermined position to each one of the services of th
2. of the keyboard Click on OK to edit the selected parameter and Right Left for changing it Once it is configured press OK Satellite input Input Sat In these options you will be able to configure the input parameters of the satellite signal L O freq Local oscillator Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 TSF 310 Input Sat RF level 013 gt LO Freq LO KU Freq 11509 1 2 TSF 310 gt Manual lt Config Auto TSF 310 Input Sat Symbol Rate 27500 gt Antenna 13V 22k Diseqc NONE User s manual TSF 310 11 TSF 310 version_en_1 1 FTE maximal Freq Input Frequency MHz Transponder frequency that you wish to tune In order to introduce the frequency press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the value Symbol Rate Symbol speed required by the transponder In order to introduce the symbol rate press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the value Antenna Feeding tone towards the LNC Options 0V 13V 13V 22kHz 18V 18V 22KHz 13V AUT 18V AUT DiseqC In this option you can set the DiseqC configuration A B C
3. of the main satellites You will be able to find more information in the law ETSI TR 101 162 v1 2 1 Satellite Net ID Original Net ID Description Hotbird 13 E Eutelsat 13 E 318 318 Eutelsat 13 E System Astra 19 2 E 1 1 Astra Satellite Network 19 2 E Astra 23 E 3 25 3 25 Astra n n 1 23 Astra 28 2 E 2 2 Astra Satellite Network 28 2 E Nilesat 7 W 2048 2048 Nilesat 101 Hispasat 30 W 33 33 Hispasat Network 1 PRO 201 Note From PRO 201 programmer you can only carry out the programming of a single module in order to carry out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX MINI series field strength meter When you connect the PRO 201 programmer it will proceed to recognize the module and to show the main menu In the main menu are shown the different options for configuring the transmodulator We have to use the Up and Down buttons of the keyboard in order to move to the different options and to get into the submenus we have to press OK button 1 Manual Inside the manual menu there are specified the different options for setting up the input output and modulation parameters 1 This field shows the type of parameter that is selected at the moment Options Input Sat Out Terr Out TV 2 This field shows the parameter that is selected In order to move around the different options we have to use the Up and Down buttons
4. 5 655 5 6 5 184 5 760 6 099 6 283 QPSK 7 8 5 443 6 048 6 404 6 598 1 2 6 221 6 912 7 318 7 540 2 3 8 294 9 216 9 758 10 053 3 4 9 331 10 368 10 978 11 310 5 6 10 368 11 520 12 197 12 567 16 QAM 7 8 10 886 12 096 12 807 13 195 1 2 9 331 10 368 10 978 11 310 2 3 12 441 13 824 14 637 15 080 3 4 13 996 15 551 16 466 16 965 5 6 15 551 17 279 18 296 18 850 64 QAM 7 8 16 329 18 143 19 211 19 793 Note Only aplicable for DVB H FRANCE 16 ZAE Les Mouilles 74570 Groisy Tel 00 33 450 68 80 17 Fax 00 33 450 68 84 68 sav ftemaximal fr www ftemaximal com DEUTSCHLAND Auf der H he 8 44536 L nen Deutschland Tel 00 49 0 23 18 78 5 01 Fax 00 49 0 23 18 78 5 200 info ftemaximal de www ftemaximal de ITALIA Via Edison 29 42040 Calerno di Sant Ilario d Enza RE Tel 00 39 05 22 90 97 01 Fax 00 39 05 22 90 97 48 fte fte it www ftemaximal com PORTUGAL Rua Jos Carlos Ary dos Santos A das Lebres Loures 2670 791 Santo Ant o do Tojal Tel 00 351 219 83 87 00 Fax 00 351 219 83 87 09 ftemaximal ftemaximal pt www ftemaximal com ESPA A Mogoda 110 Pol Industrial Can Salvatella 08210 Barber del Vall s Barcelona Espa a Tel 00 34 93 729 27 00 Fax 00 34 93 729 30 73 ftemaximal ftemaximal com www ftemaximal com UNITED ARAB EMIRATES P O Box 262442 Jebel Ali Free Zone Warehouse FZS5AB03 Dubai Tel 00 971 4 886 5700 Fax 00 9
5. It allows you to export all events registered to the connected USB device NM low Limit dB An event of error will be recorded when the value of Noise Margin is lower than the set value NM hight limit dB Once the event of error is recorded Noise Margin lt Limit Lower NM this will be Noise Margin value that will have to be exceed so the module stops being in error Clear log all devices It allows deleting the events report of all the interconnected modules Factory default This option restores the values by default of the transmodulator System information It allows you to visualize the basic information of the module model no of series firmware version etc User s manual TSF 310 7 TSF 310 version_en_1 1 FTE maximal Settings This option allows saving and loading the configuration of the module carrying out firmware update or making an adjustment of the time and date of the module Clock Set Date and time Setting of the date and time of transmodulator It is appropriate to maintain these parameters set in order to have the registration of errors linked to the current time and date Set date time all devices Loading the current date and time of the module in the rest of interconnected modules Alias Write alias It allows you to assign a name alias to the module you are programming Option only available when the Alias Auto option is configures as none manual mode Auto Alias It
6. TSF 310 USER S MANUAL User s manual TSF 310 1 TSF 310 version_en_1 1 FTE maximal NOTE This user s guide is adapted to software version v 0 0 26 of TSF 310 dated 25 10 2010 For future software updates you can download the user s guide from the following website http www ftemaximal com Chapter 1 Installation 1 1 Safety Measures 1 Never place the device next to hot sources 2 Never undergo the device to temperatures that exceed its level of operation 3 Never expose the device to leakings nor spatterings 4 Never place objects that contain liquids over the device 5 Respect the ventilation slots of the device do not cover them with any kind of object 6 The space around the device must be free of objects in a minimum radius of 40cm 7 Avoid locations with possibilities of spilling liquids on the inside of the device and with important changes of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to the electrical net 10 During the handling it is better to disconnect the device from the electrical net 11 Obey the electricity security rules during the assembling Use materials that obey the current law 12 The connecting plug must be accessible in a fast and simple way to have a fast disconnection 13 Never touch the plug with wet hands Also disconnect
7. always the device before handling the connections 14 Never put any heavy object over the device since it could get damaged 15 If the device is going to remain some time without use it is recommendable to disconnect it from the electrical net 16 The repairmen and the maintenance of the device must be done by TV and radio specialised technicians 1 2 Box content Quick installation guide 2 x Link F male F male DC Cable TSF 310 Cable 12 cm PIN to PIN RJ45 RJ45 User s manual TSF 310 2 TSF 310 version_en_1 1 FTE maximal 1 3 Description and connections The module TSF 310 is used for the reception of free channels that obey the DVB S DVB S2 standards Each module allows the reception of a complete transponder in DVB S QPSK DVB S2 QPSK 8PSK and the subsequent modulation in DVB T COFDM of it A feature of this equipment is its modulator in Vestigial Side Band or VSB This modulation can be used to distribute adjacent channels in one distribution without any intermodulation problem Each module has one Loop connector to cascade several modules at input and a Mix connector to do same in output channels The output channel is selectable between C2 and C69 All parameters are programmed by the means of PRO 201 or the EVO or MINI series of field strength meter and they are monitored in the display of programmer or in the 5 TFT screen of field strength meter TSF 310 1 Two colored led It indicates t
8. 1 media Max EVO and media Max MINI Operating temperature 0 C 45 C Consumption 5V mA 800 Consumption 12V mA 300 Consumption 24V mA 15 Consumption 30V mA 2 Dimensions 75x265x150 mm Weight 1 4Kg Chapter 3 Declaration of conformity CONFORMITY DECLARATION WE FTE MAXIMAL DECLARE THAT THE PRODUCT TSF 310 IS IN CONFORMITY WITH FOLLOWING DIRECTIVES Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC If you wish a copy of the conformity declaration please contact to the company User s manual TSF 310 16 TSF 310 version_en_1 1 FTE maximal ATACHMENT I Depending on the configured parameters we are going to obtain one particular channel capacity output useful bit rate In order to make an estimation of this output bits rate we have to take into account the following parameters Symbol duration Ts For signals of 8 MHz Mode 8K 6817 carrier 4K 3409 carrier 2K 1705 carrier Symbol duration 896 us 448 us 224 us Guard Interval 1 4 1 8 1 4 1 8 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 224us 112us 56us 28us 112us 56us 28us 14us 56us 28us 14us 7us For signals of 7 MHz Mode 8K 6817 carrier 4K 3409 carrier 2K 1705 carrier Symbol duration 1024 us 512 us 256 us Guard Interval 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 256us 128us 64us 32us 128us 64us 32us 16us 64us 32us 16us 8us For sig
9. 32 TSF 310 Out TV Mode DVB H gt RF Channel 474000 RF Level 013 User s manual TSF 310 12 TSF 310 version_en_1 1 FTE maximal 2 Auto This option allows saving and loading the configuration of the module in the PRO 201 programmer Read from module It stores the current configuration of the module in the memory of the programmer The steps to make a correct reading of the headend are specified below 1 Select the option Read from module through Up Down buttons Press OK to continue 2 Select the position of CFG memory where you wish to save the current configuration of the module 3 A window will appear and it will let you know that the reading made has been correct Write to module It loads in the module one of the configurations previously saved in the memory of the programmer The steps to make a correct configuration of the headend are specified below 1 Select the option Write to module through Up Down buttons Press OK to continue 2 Select the position of the CFG memory that you wish to copy in the module Please verify that the data of the selected memory correspond to the channel that you wish to copy 3 A window will appear and it will let you know that the configuration made has been correct 3 Config In Config option the information concerning the transmodulator is given Read log It allows reading the registered events in the module 1 Select t
10. 71 4 886 5701 www ftemaximal ae
11. D and None Auto SR Auto Symbol Rate You will be able to select if the detection of the Symbol Rate is going to be Automatic On or Manual Off In Manual mode Off the value of the Symbol Rate should be fixed by the user based on the provider s information In Automatic mode On the meter will automatically identify the SR when a Satellite carrier is tuned This feature is very useful when the provider s information is unknown The SR value found will appear in the field of selection of the SR menu This value found by the meter could not correspond exactly to the real broadcast SR but to a very close value Note The Automatic Symbol Rate feature does not work when the carrier quality is very poor or and with a very low Power Level Mode This option allows selecting the standard DVB of the transponder that you want to tune Options DVB S1 DVB S2 and auto Terrestrial modulation Out Terr These options allow configuring the DVB T DVB H modulator of the device Modulation Output modulation format QPSK 4 QAM 16 QAM 64 QAM Invert Spectrum inversion Activate or deactivate the spectrum reverse in the modulation GI Guard interval Allows selecting the guard interval of the modulation 1 4 1 8 1 16 and 1 32 BW Bandwidth Selection of the Bandwidth of the modulated signal 8 MHz 7 MHz and 6 MHz and 5MHz The 5 MHz option is only supported by DVB H standard Tx Mode FFT Mode 8K 4K and 2k The 4k option
12. Input Set Up section and you have selected the DVB T DVB H modulator configuration in the Modulator Set Up section you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services Adding services 1 Select Service to add option 2 Select one of the transponder services you want to add 3 Once you have chosen the service select the Add Remove button to include the service in the multiplex Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible variability of the bits rate of the inputs services User s manual TSF 310 9 TSF 310 version_en_1 1 FTE maximal Recomendad capacity lower to 85 Excessive capacity It is recommended to remove services Removing services 1 Select the Service to remove option 2 Select one of the transponder services you want to remove 3 Once you have chosen the service select the Add Remove button to remove the service in the multiplex Remove all services It allows removing all the services included in the multiplex Modify LCN The LNC function allows assigning automatically a predetermined position to each one of the services of the multiplex This function will allow the users who have a receiver with LNC support to make the ordination of channels automatically Note If in the existing installation there are already services t
13. Options DVB S1 DVB S2 and auto LNB Supply In this option you can set the parameters concerning the LNB RF IN Voltage 13V 18V and Off 22 kHz Tone Off On and Auto DiseqC Switch A B C D and Off 4 Modulator Set Up This option allows configuring the DVB T DVB H modulator of the device Bandwidth Selection of the Bandwidth of the modulated signal 8 MHz 7 MHz 6 MHz and 5MHz The 5 MHz option is only supported by DVB H standard FFT Mode 8K 4K and 2k The 4k option is only supported by DVB H standard Spectrum inversion Activate or deactivate the spectrum reverse in the modulation Guard interval Allows selecting the guard interval of the modulation 1 4 1 8 1 16 and 1 32 FEC Indicates the relationship between the redundant bits and the transmitted information bits 1 2 2 3 3 4 5 6 y 7 8 For example in a FEC 2 3 relation we will find 2 information bits and 1 redundant bit User s manual TSF 310 6 TSF 310 version_en_1 1 FTE maximal Modulation Output modulation format 4 QPSK 16 16 QAM 64 64 QAM Advanced settings Mode Selection of the modulation standard DVB T and DVB H Note The output useful bits rate will depends on the following parameters Bandwidth guard interval FEC codification and modulation In the Attachment I you will find all the information related to the resulting useful bit rate in each configuration 5 Set Output channel In this option you can configure
14. allows configuring the name alias of the modules automatically Options Channel Frequency Service None Upgrade Send Firmware from USB It allows carrying out the firmware update from the USB device Send firmware to all It allows carrying out the update of all the modules that are interconnected at the same time Configure all devices Input values to all devices It allows copying the current input configuration in all the interconnected modules Modulator values to all devices It allows copying the configuration of the current modulator in all the interconnected modules Output values to all devices It allows copying the current output configuration in all the interconnected modules Factory default to all devices It allows making values by default to all the interconnected modules User s manual TSF 310 8 TSF 310 version_en_1 1 FTE maximal 7 Program management New program This option allows creating a program with the current configuration of a module or group of modules Load program It allows loading a previously created program on a module or group of modules Delete program It allows deleting a program Device to process Current The creation or loading of a program will be applied only in the module that is currently connected All The creation or loading of a program will be applied to the whole group of connected modules Working disk With this option we have the possibilit
15. ber card Note In order to guarantee the right running of the different equipments of the installation we recommend you to provide the inputs and outputs which are not used with a 75 load Accessories Programmer Mod PRO 201 Code 2003123 Field strength meter Mod MediaMAX EVO S2 Code 3001006 Field strength meter Mod MediaMAX MINI S2T Code 3001026 Parabolic antenna OS series Mod OS 100 STB Code 0701105 Wide band amplifier 47 862MHz Mod AMP 310 P Code 2003520 Mixer Mod MUX 310 Code 2003518 User s manual TSF 310 15 TSF 310 version_en_1 1 FTE maximal Chapter 2 Technical features Ref TSF 310 Code 2003542 Input frequency margin 950 2150 MHz Input level 25 to 65 dBm Imput impedance 75 LNB feeding conmutation 13V 18V 0 22kHz Input connector Female F connector Input LOOP losses lt 1 dB FEC 1 2 2 3 3 4 5 6 7 8 8 9 9 10 1 4 1 3 1 5 2 5 3 5 4 5 DVB RS 204 188 Input modulation QPSK 8PSK Input Symbol Rate DVB S 1 45 MS s DVB S2 1 37 MS s Modulation Error Ratio MER Typ 38 Min 36 Selectable format of output modulation DVB T DVB H Bandwidth MHz DVB T 6 7 8 DVB H 5 6 7 8 Mode DVB T 2k 8k DVB H 2k 4k 8k Output channels C2 C69 Output connectors Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses lt 1 dB Band spurious 60 dBc Programming Interface RJ 45 Programmer PRO 20
16. e multiplex This function will allow the users who have a receiver with LNC support to make the ordination of channels automatically Select a channel through Left Right buttons and introduce the position Press the OK button and the cursor will be placed over the number With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the changes Note If in the existing installation there are already services that have LNC system you will have to configure the position of the module services in order to avoid conflicts with other net services TSF 310 Operation finish TSF 310 Input 083 PID 06000 Das Erste Rem All TSF 310 BW usage 083 gt Delete services Add services TSF 310 Operation finish TSF 310 Input 035 PID 06200 arte HD Add TSF 310 BW usage 000 Delete services gt Add services TSF 310 LCN 00004 arte HD User s manual TSF 310 14 TSF 310 version_en_1 1 FTE maximal 1 5 Accessories and example of installation Example of installation Installation that consist of 6 TSF 310 and that will allow tuning channels up to 6 different transponders and to distribute them through a TV network in DVB T The distributed channels need a terrestrial receiver in order to be decoded in this case we propose a PVR T160 CI HDMI receiver that would decode free channels and also encoded channels if we insert a PCMCIA with the corresponding subscri
17. hat have LNC system you will have to configure the position of the module services in order to avoid conflicts with other net services Bandwidth limitation It allows selecting the of the capacity of the output channel Auto service addition On It selects the services automatically when an input carrier is tuned and when the list of selected services is empty The receiver will have this state by default Always It selects the services automatically every time a new input carrier is tuned This state is only recommended to be used for making test in the module Off The automatic mode is deactivated the services have to be manually selected Advanced settings Network It allows making the adjustment of the identification parameters of the multiplex TS ID Transport Stream identification value It is recommended to configure a value different from TS ID for each one of the output multiplex configured Net ID Net identification value Original Net ID Original net identification value Network Name Name associated with the net User s manual TSF 310 10 TSF 310 version_en_1 1 FTE maximal Services Change service name It allows changing the name of the service manually In order to do so please choose the service in the first line and then write the new name in the second line Then you have to press modify in order to save the changes Next it is attached the identification table NID ONID
18. he different states of the device 2 OUT This connector supplies the modulated channel according to the selected standard in the module and mixes it with all the signals that it receives through the MIX connector 3 MIX Input of mixing of the module 4 LNC IN To connect to the LNC or to the LOOP OUT output of the previous module 5 LOOP OUT To connect to the ANT IN input of the next module 6 RS 232 Ethernet connector to cascade modules with the RCM 310 telecontrol unit with the RJ45 RJ45 cable provided 7 PRO 201 Ethernet connector to make the programming with the programmer 8 DC connectors It has two connectors for input output States of two colored leds 1 Initialization mode Green main application charged Blinking Green Completing the initial sequence at the moment when the module gets initialized the led will turn into one of the states the operating mode Red Phase of initializing the module 2 Operative Mode Green The system is working properly Orange At least one critical event has been recorded in the module The led will only change into green when the registration of events has been read by the programmer Red Error or alert detected in the running of the device the led will be on only as long as the error alert is present Once the error or the alert disappears the led will change into orange because the error alert is stored in the registration of events 3 Programming mode When the mod
19. he option Read LOG file through Up Down buttons Press OK to continue 2 Press OK again to show the log file 3 A new window will appear It will show the information about the registered events in the module Press the following keys in order to scroll up and down the screen up down Delete LOG file It allows deleting all events stored until this moment Factory default This option restores the values by default of the transmodulator Update FW It allows carrying out the firmware update from the programmer Output services This option allows making the selection of the services that you wish to include in the output multiplex Once you have tuned a transponder and you have selected the DVB T DVB H modulator configuration you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services TSF 310 N 00001 Status 03 07 02 11 09 05 02 Front end lock TSF 310 OK to Show LOG TSF 310 LCN gt Read LOG file Delete LOG file TSF 310 Operation finish TSF 310 CFG 01 Freq 11362 Sr 27500 Output Freq 850000 TSF 310 gt Write to Module Read from Module TSF 310 Operation finish TSF 310 CFG 03 Free position TSF 310 gt Read from Module Write to Module TSF 310 gt Read from Module Write to Module TSF 310 LCN gt Read LOG file Delete LOG file User s manual TSF 310 13 TSF 310 version_en_1 1 FTE maximal
20. he programming both from corresponding EVO and MINI field strength meter as well as from PRO 201 mediaMAX EVO mediaMAX MINI In order to start programming the TSF 310 transmodulator you will have to go to Tools option through the key 8 of your field strength meter and to select the Transmodulator Prog option Then it will proceed to recognize the module and to show the main menu In the Transmodulator Prog are shown the different configuration options that this tool offers 1 Select Device The field strength meter allows carrying out the programming of one or several transmodulators from an only transmodulator Without interconnection of modules An only module connected Interconnection of several modules you can select which module you wish to program User s manual TSF 310 5 TSF 310 version_en_1 1 FTE maximal 2 Device Status In the option Device Status are specified the main parameters of the module at this moment Front End It indicates whether the module is hooked or without signal Input bit rate Transfers of data in the satellite tuner input Output bit rate Transfer of data in the module output BER before and after Viterbi It indicates the error rate of bits of the input signal before and after the correction produced by Viterbi algorithm MER Parameter that indicates the quality of the input modulated digital signal expressed in dB Noise Margin It indicates the diffe
21. is only supported by DVB H standard FEC Indicates the relationship between the redundant bits and the transmitted information bits 1 2 2 3 3 4 5 6 y 7 8 For example in a FEC 2 3 relation we will find 2 information bits and 1 redundant bit Mode Selection of the modulation standard DVB T and DVB H Note The output useful bits rate will depend on the following parameters Bandwidth guard interval FEC codification and modulation In the Attachment I you will find all the information related to the resulting useful bit rate in each configuration Output configuration TV output In these options you can configure the output parameters of the terrestrial signal RF Channel MHz Output frequency of terrestrial modulation In order to introduce the frequency press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the value Options 47 862 MHz RF Level Regulation of the output level of the modulated signal Options 0 15dB Summary table Satellite input Terrestrial output TV output L O frequency Input Frequency Symbol Rate Antenna Diseqc Symbol rate auto DVB Mode Modulation Invert Spectrum Inversion Guard Interval GI Bandwith BW Tx Mode FFT Mode FEC Mode RF Channel RF Level TSF 310 Out Terr Modulation 4 gt Invert No GI 1
22. n 1 4 1 8 1 16 1 32 1 2 4 354 4 838 5 123 5 278 2 3 5 806 6 451 6 83 7 037 3 4 6 532 7 257 7 684 7 917 5 6 7 257 8 064 8 538 8 797 QPSK 7 8 7 62 8 467 8 965 9 237 1 2 8 709 9 676 10 246 10 556 2 3 11 612 12 902 13 661 14 075 3 4 13 063 14 515 15 369 15 834 5 6 14 515 16 127 17 076 17 594 16 QAM 7 8 15 24 16 934 17 93 18 473 1 2 13 063 14 515 15 369 15 834 2 3 17 418 19 353 20 491 21 112 3 4 19 595 21 772 23 053 23 751 5 6 21 772 24 191 25 614 26 39 64 QAM 7 8 22 861 25 401 26 895 27 71 Useful channel capacity 6 MHz Guad Interval Modulation FEC codification 1 4 1 8 1 16 1 32 1 2 3 732 4 147 4 391 4 524 2 3 4 976 5 529 5 855 6 032 3 4 5 599 6 221 6 587 6 786 5 6 6 221 6 912 7 318 7 54 QPSK 7 8 6 532 7 257 7 684 7 917 1 2 7 465 8 294 8 782 9 048 2 3 9 953 11 059 11 709 12 064 3 4 11 197 12 441 13 173 13 572 5 6 12 441 13 824 14 637 15 08 16 QAM 7 8 13 063 14 515 15 369 15 834 1 2 11 197 12 441 13 173 13 572 2 3 14 929 16 588 17 564 18 096 3 4 16 796 18 662 19 76 20 358 5 6 18 662 20 735 21 955 22 62 64 QAM 7 8 19 595 21 772 23 053 23 751 Useful channel capacity 5 MHz Guad Interval Modulation Codificaci n FEC 1 4 1 8 1 16 1 32 1 2 3 110 3 456 3 659 3 770 2 3 4 147 4 608 4 879 5 027 3 4 4 665 5 184 5 489
23. nals of 6 MHz Mode 8K 6817 carrier 4K 3409 carrier 2K 1705 carrier Symbol duration 1194 6 us 597 3 us 298 6 us Guard Interval 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 298 7us 149 3us 74 7us 37 3us 149 3us 74 6us 37 3us 18 6us 74 6us 37 3us 18 6us 9 3us For signals of 5 MHz Modo 8K 6817 carrier 4K 3409 carrier 2K 1705 carrier Symbol duration 1433 6 us 597 3 us 298 6 us Guard Interval 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Duration 358 4us 179 2us 89 6us 44 8us 179 2us 89 6us 44 8us 22 4us 89 6us 44 8us 22 4us 11 2us Modulation Modulation QPSK 16 QAM 64 QAM Number of bits per symbol 2 4 6 FFT Mode FFT Mode 8K 4K 2K Data carriers 6048 3024 1512 Total carriers 6817 3409 1705 Bits rate calculation total L b fs Tbtotal Where Fs Symbols frequency symbols sec fs 1 Ts Ts Symbol duration Symbol Time Guard Interval time b Number of bits per symbol depending on the modulation L Number of data carriers depending of FFT mode Bits rate calculation useful Salomon ed FEC total util Codif Codif Tb Tb Re FEC Cod FEC Codification 1 2 2 3 3 4 5 6 7 8 Reed Salomon Cod Codification made by the means of Reed Salom n algorithym 188 204 Case study example For example in the case of a DVB T transmission in Spain the configured parame
24. rence between the value of current C N and the value of C N at the point of pixilation of the signal that is the quantity of dBs of C N measure that are needed to lose the input signal Temperature It indicates the current temperature of the module in C 3 Set Front End In this option you will be able to configure the input parameters of the satellite signal Local oscillator Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 Frequency MHz Transponder frequency that you wish to tune Symbol speed Symbol speed required by the transponder Auto symbol rate You will be able to select if the detection of the Symbol Rate is going to be Automatic On or Manual Off In Manual mode Off the value of the Symbol Rate should be fixed by the user based on the provider s information In Automatic mode On the meter will automatically identify the SR when a Satellite carrier is tuned This feature is very useful when the provider s information is unknown The SR value found will appear in the field of selection of the SR menu This value found by the meter could not correspond exactly to the real broadcast SR but to a very close value Note The Automatic Symbol Rate feature does not work when the carrier quality is very poor or and with a very low Power Level DVB This option allows selecting the standard DVB of the transponder that you want to tune
25. ters would be the following 8k mode 2 3 FEC guard intervals 64QAM constellation for an 8 MHz channel and using the previous formula you will get the following channel useful capacity Mbps Tb til 905 19 Note As you select a configuration with a higher output channel capacity the protection grade against mistakes gets proportionally decreased Next it is shown the channel capacity for systems without hierarchy in all the cases of constellation guard interval and codification relation for transmissions of 8MHz 7MHz 6MHz y 5MHz DVB H The useful capacity channel is identical for modes 2k 4k DVB H and 8k User s manual TSF 310 17 TSF 310 version_en_1 1 FTE maximal Useful channel capacity 8 MHz Guad Interval Modulation FEC codification 1 4 1 8 1 16 1 32 1 2 4 976 5 529 5 855 6 032 2 3 6 635 7 373 7 806 8 043 3 4 7 465 8 294 8 782 9 048 5 6 8 294 9 216 9 758 10 053 QPSK 7 8 8 709 9 676 10 246 10 556 1 2 9 953 11 059 11 709 12 064 2 3 13 271 14 745 15 612 16 086 3 4 14 929 16 588 17 564 18 096 5 6 16 588 18 431 19 516 20 107 16 QAM 7 8 17 418 19 353 20 491 21 112 1 2 14 929 16 588 17 564 18 096 2 3 19 906 22 118 23 419 24 128 3 4 22 394 24 882 26 346 27 144 5 6 24 882 27 647 29 273 30 16 64 QAM 7 8 26 126 29 029 30 737 31 668 Useful channel capacity 7 MHz Guad Interval Modulation FEC codificatio
26. the different parameters of the cable signal Channel standard It allows you to select the channelling of the cable signal standards Options BG BG PAL BG IT 11 M NTSC PAL M PAL N PAL DK PAL I BB_AU DK PAL L PAL Channel Output channel of the cable modulation When you select the output channel the field Frequency MHz will be modified automatically adapting itself to the selected channel Options C2 C69 Frequency MHz Output frequency of cable modulation When you modify this field the field Channel will be also modified indicating the channel equivalent to the selected frequency in the case that this frequency corresponds to the frequency of a channel Options 47 862 MHz Level Regulation of the output level of the modulated signal Options 0 15dB Calibration Allows the realization of two tests in order to verify the correct running of the device Deactivate output It allows activating or deactivating the ouput of transmodulator Switch output to CW It allows activating or deactivating the DVB T DVB H modulation allowing visualizing the carrier without modulation in the selected frequency 6 System This option provides information of the transmodulator System logfile In this field are indicated the registered events in the module Read log It allows reading the registered events in the module Clear log It allows deleting all events stored until this moment Export log to USB
27. ule detects an external programmer the led will blink in the next sequence green orange red Once you leave the programming mode the led will turn into the corresponding operating mode 5 2 3 4 6 7 8 1 User s manual TSF 310 3 TSF 310 version_en_1 1 FTE maximal Stages of transmodulator TSF 310 Input Selection of a tuned satellite transponder Transmodulation The tuned channels of the transponder are modulated according to the DVB T rules If the transponder has encoded channels the final user will need a receiver with CI subscriber card or an encrypted channels receiver Out Configuration of the channels and output parameters 1 4 Programming TSF 310 has two ethernet connectors In order to make the programming of the module you have to connect the corresponding programmer to PRO 201 connector You can make the programming through the PRO 201 programmer and also through the mediaMAX EVO and mediaMAX MINI field strength meter 1 4 1 Programming modes With mediaMAX EVO mediaMAX MINI field strength meter you can carry out the programming of all the modules consecutively as long as they are interconnected with each other through the RJ 45 cable supplied with each unit Through PRO 201 the programming is made module by module User s manual TSF 310 4 TSF 310 version_en_1 1 FTE maximal 1 4 2 Programming Below you will find the steps to follow in order to make t
28. y of choosing if we want to work into the internal disk or in the external storage device USB 2 0 Once the option is selected a dialog box will appear and we will be able to choose among three different options Auto The Meter decides where the data will be stored If there is external memory connected the Meter will store the data in it If not it will use the internal memory USB The Meter always will try to use the external memory connected to the USB port If this memory has not been connected an error message will be shown reminding that there was an error storing the data and it will be not stored Internal Always the internal memory is used to store the data Load programs from USB This option allows importing programs from a USB memory to the field strength meter Before using this option you must connect a USB memory Save programs to USB This option allows copying the programs stored in the external USB 2 0 storage device Write Alias It allows saving the alias of the module in the program Options Yes No 8 Set Output Services This option allows making the selection of the services that you wish to include in the output multiplex Add Remove services It allows adding the services to the multiplex and also removing the ones previously included The lower bar informs about the available space in the output multiplex As you add more services the space available will decrease Once you have tuned a transponder in the