1. Advanced and click on the Next button 4 Browse to the following folder on the driver CD according to your operating system Windows XP 32 bit and Server 2003 32 bit D Marvell 88SE9230 Windows miniport i386 Windows XP 64 bit and Server 2003 64 bit D Marvell 88SE9230 Windows miniport amd64 5 Follow the on screen instructions to install the driver 6 After successful installation the SATA controller is listed in the Device Manager as Marvell 92xx SATA 6G Controller under SCSI and RAID controllers 7 For this controller an additional device Marvell Console SCSI Processor Device is detected Select No not this time and click the Next button to continue 8 Select Install from a list or specific location Advanced and click on the Next button 9 Browse to the following folder on the driver CD according to your operating system Windows XP 32 bit and Server 2003 32 bit D Marvell 88SE9230 Windows storport i386 Windows XP 64 bit and Server 2003 64 bit D Marvell 88SE9230 Windows storport amd64 10 Follow the on screen instructions to install the driver 11 After successful installation the device is listed in the Device Manager as Marvell Unify Configuration under System devices 12 Once driver installation is completed you can now connect your external devices to the SATA card To install the driver for the external devices please refer to the external device user s manuals Updating Drivers and Ma
2. User Man ua SE MANL EST16A EN 1 INTRODUCTION The PCI Express SATA RAID controller card employs the Marvell HyperDuo technology to take the advantages of the rapid respond of a solid state drive SSD and the spacious capacity of a hard disk drive HDD to form an ultimate total solution for a high performance cost effective and large storage system HyperDuo uses an intelligent algorithm to automatically migrate the most frequent access data on the SSD while all the rest of the data are safely kept on the hard disk All these operations are managed by a Storage Utility which organizes the combination of these physical disks as a HyperDuo Virtual Disk and is totally transparent to users The controller card also offers a high performance hardware RAID 0 RAID 1 with SATA 6 0Gbps architecture solution to the desktop consumer storage applications utilizing a native 2 Lane PCI Express 2 0 interface to the host controller board The orientation and position of SATA ports are well designed so that the cable wiring fits easily in computer chassis and all of those ports can be configured manually for mSATA SSD HDD in some specific models FEATURES amp SPECIFICATION General e Based on Marvell PCI Express 2 0 SATA 6Gbps controller e 2 Lane PCI Express 2 0 interface supports communication bandwidth up to 10 0Gbps e Compliant with PCI Express 2 0 Base Specification Unique Hard Drive Activity LED indicator circuit design The LED blinks when t
3. er card 8 Roll over the Operation tab and you will see Create HyperDuo Create RAID and Quick Create Wizard 9 To create a HyperDuo virtual disk you should have at least one HDD and one multiple SSD 10 Select Create HyperDuo and then select Safe mode or Capacity mode 11 Check Keep Original Data to preserve the data currently on your HDD or uncheck it to erase all data This option is only available in Safe mode 12 Enter a number between 10 and 100 in the Threshold field The Threshold number defines the percentage of your SSD the MSU uses to optimize performance The default is 90 13 Press Submit The MSU displays the Property tab for the HyperDuo virtual disk and begins initialization It takes up to some minutes to complete System performance may slow during this period 14 If you want to quickly create a HyperDuo virtual disk select Quick Create Wizard 15 Select Safe mode or Capacity mode and then press Submit The MSU will help you create the HyperDuo virtual disk automatically 16 To create a RAID virtual disk select Create RAID Then select RAID level RAIDO RAID1 or RAID10 17 Choose enough available physical disks RAIDO needs at least two physical disks RAID1 just needs two physical disks and RAID10 needs four physical disks and press Next 18 Enter the name for the virtual disk or you can use the default name 19 Select the Initialization method for the virtual disk 20 Select the Stripe S
4. here is read write activity on any one of the hard drive connected to the motherboard or to this add on card Optional Supports Windows 8 1 8 7 Vista XPServer 2003 2008 32 64 bit Server 2008 R2 Linux and MAC OS Serial ATA SATA Interface e Changeable SATA 6 0Gbps ports SATA mSATA or their combination Up to 4 SATA devices with point to point connectivity e Compliant with Serial ATA Specification 3 0 Supports communication speed of 6 0Gbps 3 0Gbps and 1 5Gbps e Supports Hardware RAID 0 1 10 and JBOD e HyperDuo mode supports Safe mode Mirrored Protection and Capacity mode Cost Optimized to build a system with SSD and HDD hybrid Bootable e Supports Native Command Queuing NCQ FIS based Port Multiplier Supports SATA port Hot Plug e Supports both Standard and Low profile PACKAGE CONTENTS e PCI Express SATA RAID controller card x 1 1 Driver CD x 1 User s manual x 1 Screws Optional LED cable x 1 BEFORE INSTALLATION The user must have basic knowledge of installing an add on card and its driver to a desktop PC If you have any queries please call your local dealer or find somebody who is experienced in computer hardware installation e Motherboard with a free PCI Express 2 0 slot x4 x8 x16 and a supported operating system installed WARNING Before installing and activating the controller card please make sure you have a complete backup of your existing data from hard drives Manufacturer
5. hich you can change the SATA mSATA port on the card freely by changing the jumper header Please refer to below table for jumper setting 2 CN2 Upper SATA CN8 mSATA CN2 Lower SATA CN7 mSATA Note All other combinations of jumper setting are sie Marvell BIOS Utility MBU for RAID HyperDuo Setup Warning All the data on the hard disks connected to the controller card will be permanently erased in the following actions r create a RAID HyperDuo virtual disk N W N Power up your computer Skip this section if you are not going to create a RAID HyperDuo virtual disk Press the Ctrl M key on the keyboard at the same time to enter the Marvell BIOS Utility MBU Once the MBU is entered scroll to HBAO Marvell 0 in the Topology pane by the up and arrow key on the keyboard and press Enter Choose Configuration Wizard and press Enter to start creating the RAID HyperDuo virtual disk Select the free physical disks available by using the arrow keys to scroll through the disks and press Space Bar After selecting all the disks needed press Enter to continue Choose the RAID option RAID Level RAID 0 Striping RAID 1 Disk Mirroring RAID 10 Stripe of mirrors Stripe Size 32K 64K It defines the size of the single data block on the virtual disk The larger the stripe size the longer it takes to read and write data blocks on the physical disks A large size is recommended for appl
6. ications requiring large data transfers e g audio video and graphics A smaller size is suitable for applications with smaller size files e g emails and documents Name any value for the users to input Input a user defined identifier for the virtual disk Choose the HyperDuo option HyperDuo Mode Safe Mirrored Protection Capacity Cost Optimized 3 8 9 Keep original data Yes No Only available in Safe mode Preserve the data currently on your HDD or erase all data Threshold 10 100 for the users to input The number defines the percentage of your SSD the MBU uses to optimize performance Default is 90 Choose Next and press Y key to start creating the virtual disk Press F10 and Y key to exit the MBU Note A HyperDuo virtual disk must at least contain one SSD and one HDD To rebuild a virtual disk 1 pe ka When a hard disk in a RAID 1 virtual disk or a SSD in a HyperDuo Safe mode virtual disk is defective or the data inside are corrupted the Marvell BIOS Utility MBU will mark the virtual disk as Degrade Replace the defective hard disk SSD with an identical hard disk SSD or a hard disk SSD which has a smaller size within the allowable value set for the virtual disk Press the Ctrl M key on the keyboard at the same time to enter the MBU In the Topology pane scroll to the Virtual Disks ID press Enter and select the Rebuild option Select the available replacement hard disk SSD to be
7. is not responsible for data loss due to abuse misuse or neglect Should you have any installation problem please contact your dealer for assistance HARDWARE INSTALLATION 1 Turn off your computer and all external devices connected to it 2 Disconnect your computer from the power sources 3 Open the computer case Refer to your computer user manual for more details 4 Find an available PCI Express 2 0 slot and remove the slot bracket Save the bracket screw for later use Align the controller card horizontally with respect to the slot and insert it into the slot firmly and evenly Take care not to force it into the slot Once you have properly positioned the controller card into the slot fasten it to the computer case with the screw you have just saved Mount the hard disk s on the computer case Connect the power cable to the hard disk s Connect the SATA hard disk s to the controller card with the SATA cable s If you use mSATA SSD mount your SSD to mSATA connector and secure it with screw in the package 10 Connect the computer case s front panel Hard Disk LED cable to pin header JP9 See Figure 1 JP9 gt t Figure 1 11 Connect the one end of the LED cable optional to pin header JP10 and the other end to your motherboard s HDD LED connector 12 Secure the computer case and switch on your computer ea Oo CO N OV Port Configuration Optional features There are some specific models in w
8. ize 32K or 64K for the virtual disk 21 Press Submit The MSU creates the virtual disk and displays the Property tab for the new virtual disk 22 Restart your computer to use the virtual disk DRIVER INSTALLATION Installing Driver for supported Windows Vista Server 2008 Server 2008 R2 and Windows 8 1 8 7 operating system Start Windows and insert the driver CD into the CD ROM drive assume drive D 2 Windows will automatically detect the SATA card Right click Marvell Console ATA Device with yellow mark in the Other Devices and select Update Driver Software 3 Select Browse my computer for driver software 4 Browse to the following folder on the driver CD according to your operating system Windows Vista Server 2008 Windows 8 1 8 7 32 bit D Marvell 88SE9230 Windows storport i386 Windows Vista Server 2008 Windows 8 1 8 7 64 bit and Server 2008 R2 D Marvell 88SE9230 Windows storport amd64 4 Follow the on screen instructions to install the driver After successful installation the device is listed in the Device Manager as Marvell Unify Configuration under System devices nn 5 Installing Driver for supported Windows XP Server 2003 operating system 1 Start Windows and insert the driver CD into the CD ROM drive assume drive D 2 Windows will automatically detect the SATA card Select No not this time and click the Next button to continue 3 Select Install from a list or specific location
9. nual The latest drivers full version manual and last minute changes document are available on the website below http www drivers download com Search for the following Download Code from Drivers Search Marvell 88SE9230 PCI Express to SATA 6Gbps RAID controller card DL 0141401 All specifications and information are subjected to change without prior notice All brand company names logos and trademarks referenced in this manual are the property of their respective owners Our products including the packaging are not toys and they might contain small parts and sharp objects Please keep away from children
10. rebuilt to by pressing Space Bar and then Enter Press Y key to start The utility will show the rebuild status and the completed percentage This will take a long time to finish the whole process and it depends on the size to be rebuilt Note HyperDuo virtual disk created in Safe mode can be partially rebuilt if the SSD fails but not if the HDD fails Marvell Storage Utility MSU for RAID HyperDuo Setup The Marvell Storage Utility MSU is a browser based management utility for Marvell 88SE92xx controllers It creates and manages a RAID or HyperDuo virtual disk using storage devices connected to the 88SE92xx controller 1 2 3 4 5 Start Windows and insert the driver CD into the CD ROM drive assume drive D Browse to the following folder on the driver CD D Marvell 88SE9230 Utility Run MSUSetup exe to start utility installation Follow the on screen instructions to install the MSU Double click the desktop shortcut for the MSU When opening the MSU in some versions of Windows Internet Explorer may detect a problem with the security certificate for the MSU web page Select Continue to this website not recom mended to continue opening the MSU Opening the MSU will take you to a login page If you have no password leave this field blank and then click Login After entering the MSU user interface select Adapter which contains four physical disks assume four physical disks are connected to the controll