1. Installation Guide Installationsanleitung Guia de Instalacion Guida de Installazione Guide d Installation Installatie gids Inverted Projector Thread Depth Indicator Thread Depth Indicator Figure 3 Figure 2 Marking the Depth Threaded Insert Thread Depth Indicator Warranty http www mounts com warranty Garantie Garantia Garanzia Garantie Waarborg 9531 000 000 0X Rev 0 N TH S PRE IER MOUNTS ORIGINAL MOUNT COMPANY www mounts com North America 800 368 9700 International 1 714 632 7100 Europe 44 0 24 7664 4105 Insert the Thread Depth Indicator into the thread inserts found on the bottom or top of the projector Use a pencil to mark the depth of the thread insert on the Thread Depth In dicator as shown Insert the Thread Depth Indicator into the remaining thread inserts to compare and verify their depth Locate the correct diameter screw for the thread insert If the screw you selected is longer than the mark on the Thread Depth Indicator as shown in Figure 2 and Figure 3 do not use this screw The screw length must not bypass the mark Select another screw length until you find a screw that comes closest to the mark without going past the mark Test each size of the screws provided The correct screws should thread easily into the mount point and not pull out when tension is applied The optional M3 flat washers may be used to decrease the screw depth of eit
2. Mount M6 x 6mm screw ECM 4000 Installation Guide Installationsanleitung Guia de Instalacion Guida de Installazione Guide d Installation Installatie gids Install the mount according to the instructions provided by Premier Mounts Ensure all structural reinforcements have been made before attaching the flat panel to the ECM 4000 Do not release the flat panel until the mounting bracket arms are fully resting on the elliptical mounting bar Raise the mounting bracket arms and the attached flat panel over the elliptical mounting bar of the ECM 4000 Mounting Bracket Arms Elliptical Mounting Bar Lower and center the mounting bracket arms with the at tached flat panel onto the elliptical mounting bar of the ECM 4000 Repeat Steps 1 and 2 for mounting the remaining elliptical tilt mounts Do not release the flat panel until the mounting bracket arms are resting fully on the elliptical mounting bar Warranty http www mounts com warranty Updates The most up to date installation Garantie Garant a Garanzia Garantie Waarborg guides can be found at mounts com 9531 000 000 0X Rev 0 DD R E R M O U N TS THE ORIGINAL MOUNT COMPANY www mounts com North America 800 368 9700 International 1 714 632 7100 Europe 44 0 24 7664 4105 When attaching the decorative covers verify that the smaller mounting hole is above the larger mounting hole Place the first decorative cover over the f
3. UNE ECM 4000 Installation Guide Installationsanleitung Gu a de Instalacion Guida de Installazione Guide d Installation Installatie gids Elliptical Ceiling Mount for 37 to 63 Flat Panels Model ECM 4000 Warranty Garantie Garantia Garanzia Garantie Waarborg http www mounts com warranty www mounts com North America 800 368 9700 International 1 714 632 7100 1321 S State College Blvd Fullerton CA 92831 USA 9531 000 000 0X Rev 0 Max Flat Panel Capacity 80 Ib each Included components x1 x8 x8 xd N x1 Quad Mount side Skin Elliptical Decorative Meira Thread Depth 5 Allen Wrench Structure Tilt Mount Covers Bracket Arms Indicator x24 J x24 E x24 x24 x24 x24 D x24 M4x25mm M4x30mm M5 x 16mm M5x25mm M5x30mm M6x16mm M6x 25mm M4 x 16mm TN 4 a 47x32 x24 x24 x24 x24 x24 24 ES Griplate M6 x 30mm M6x45mm M8 x 16mm M8 x 25mm M8 x 30mm M8 x 45mm M8 x 70mm Washers Universal Spacers AST 2446 2 Required for installation SS e The ceiling should be capable of supporting a weight of at least five times the product weight If not the ceiling surface must be reinforced Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to AST 2446 2 Mounting hardware is not included with this product Commercially available hardware must be used for this installation The hardware used will depend on your installation envi
4. he Original Position Lower Nut AMO Place one hand at the center top edge of the flat panel Warranty http www mounts com warranty Updates The most up to date installation Garantie Garant a Garanzia Garantie Waarborg guides can be found at mounts com 9531 000 000 0X Rev 0 Place the other hand on the center bottom edge of the flat panel Using the upper hand gently push the top of the flat panel towards the wall while the lower hand gently pulls the bottom of the flat panel away from the wall 4 PREMIER MOUNTS ORIGINAL MOUNT COMPANY IN www mounts com North America 800 368 9700 International 1 714 632 7100 Europe 44 0 24 7664 4105 ECM 4000 Installation Guide Installationsanleitung Guia de Instalacion Guida de Installazione Guide d Installation Installatie gids PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Lifetime Warranty Premier Mounts warrants all mounting products to be free from defects in material and workmanship for the lifetime of the original installation of the product What Premier Mounts Will Do At the sole option of Premier Mounts Premier Mounts will repair or replace any product or product part that is defective lf Premier Mounts chooses to replace a defective product or part a replacement product or part will be shipped to you at no charge but you must pay any related labor costs What is Not Covered Limi
5. her the M2 5 x 12mm screws or the M3 x 16mm screws Decrease the screw depth by placing an M3 flat washer inside the leveling barrel and then inserting the mounting screw Premier Mounts Griplate Washers are designed to accom modate the various M4 M5 M6 and M8 hole sizes required by flat panels Do not place excessive pressure on the back of the flat panel as this may damage your flat panel The Griplate Washer must be installed between the head of the mounting screw and the mounting bracket as shown Does your flat panel have Recessed mount points Uneven mount points A curved back Any obstruction near the mount point If Yes you must install nylon spacers Remove the mount ing brackets Griplate washers and mounting screws from the back of the flat panel Updates The most up to date installation guides can be found at mounts com Premier Mounts nylon spacers allow you to attach the mounting bracket to flat panels which have recessed or uneven mount points Each nylon spacer will add distance between the mounting bracket and your flat panel The nylon spacers must only be installed between the mounting bracket and your flat panel The nylon spacers will fit M4 M5 M6 and M8 screw sizes Attach the eliptical tilt mount using four 4 M6 x 6mmscrews Flat Panel Nylon Spacer Mount Point Eliptical Tilt
6. irst mounting bracket arm and push firmly into place Align the mounting holes together Insert the M4 x 6mm Phillips screw smaller mounting hole Insert the M6 x 25mm Phillips screw larger mounting hole Use a screwdriver to tighten all decorative cover mounting hardware Repeat Steps 1 through 5 for the remaining decorative covers and mounting bracket arms Do not overtighten these screws Route the cables through the cable access holes and to their respective locations Remove the plastic covers route the cables and gently re attach the plastic covers The cables may then be routed through the bracket up the ceiling adapter and into the ceiling to a predetermined power source Decorative M4 x OMM Screw Screwdriver M6 x 25mmM Screw Source or A V Cable ECM 4000 Installation Guide Installationsanleitung Guia de Instalacion Guida de Installazione Guide d Installation Installatie gids Adjusting the Flat Panel Friction Tilt Angle Place one hand at the center top edge of the flat panel Place the other hand on the center bottom edge of the flat panel Using the upper hand gently pull the top of the flat panel towards you while the lower hand gently pushes the bottom of the flat panel away from you If additional tilt friction is required tighten the lower nut and lower bolt only to increase the tilt friction Lower Bolt Adjusting the Flat Panel to t
7. ronment i e wood stud concrete surface metal l beam etc oe Upper Half 00000 2 BA Separate the upper and lower halves of the AST 2446 2 by removing both M8 screws and wave washers Unpack the trio mount and place it on the ground J ooooovoo o Lower Half The set screw on the threaded coupler must be backed out in order for the AST 2446 2 to be threaded into place Thread the lower half of the AST 2446 2 into the threaded coupler on the trio mount The lower half of the AST 2446 2 must be threaded fully until the piece is safely secured to the threads then tighten the screw back into place Use the screwdriver to tighten the set screw once the AST 2446 2 has been attached Upper Half Lower Half Minimum four 4 complete turns The following steps must be performed by a minimum of three people Two people lift the trio mount into place Align the upper and lower halves of the AST 2446 2 Slide the lower half trio mount into the upper half of the AST 2446 2 It is recommended that the height and location of the ECM 3000 be determined prior to performing the following steps Determine the mounting height Align the M8 mounting holes on the upper Pan Philips and lower halves of the AST 2446 2 and insert the M8 screws and wave Threaded washers Use the 516 wrench to tighten the M8 screws Coupler Verify that all hardware is secure and tight before proceeding to the next section ECM 4000
8. tations Premier Mounts disclaims any liability for damage to mounts adapters displays projectors other property or personal injury resulting in whole or in part from improper installation modification use or misuse of its products NOTWITHSTANDING ANYTHING TO THE CONTRARY IN THIS WARRANTY THIS WARRANTY IS LIMITED TO FIVE YEARS FROM THE DATE OF PURCHASE IN THE EVENT THAT THE WARRANTED PRODUCT IS COMMERCIALLY RENTED OUT Electrical products and components such as amplifiers soeakers motors switches remote controls and related electrical items are backed by a 3 year warranty Premier Mounts disclaims all other warranties express or implied including warranties of merchantability and fitness for a particular purpose Premier Mounts is not responsible for incidental or consequential damages including but not limited to inability to use its products or labor costs for removing and replacing defective products or parts Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you What Customers Must Do for Warranty Service If you discover a problem that you think may be covered by the warranty you must report it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt from the original consumer purchaser must accompany all warranty claims Warranty claims must also include a description of the problem the p
9. urchaser s name address and telephone number General inquiries can be addressed to Premier Mounts Customer Service at 1 800 368 9700 Warranty claims will not be accepted over the phone or by fax Premier Mounts Attn Warranty Claim 1321 S State College Blvd Fullerton CA 92831 USA How State Law Applies This warranty gives you specific legal rights and you may also have other rights which vary from state to state Premier Mounts intends to make this manual accurate and complete However Premier Mounts makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Premier Mounts makes no representation of warranty expressed or implied regarding the information contained herein Premier Mounts assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Warranty http www mounts com warranty Updates The most up to date installation m i ar Garantie Garant a Garanzia Garantie Waarborg guides can be found at mounts com 9531 000 000 0X Rev 0 4 REMIER MOUNTS THE ORIGINAL MOUNT COMPANY www mounts com North America 800 368 9700 International 1 714 632 7100 Europe 44 0 24 7664 4105
Download Pdf Manuals
Related Search
Related Contents
Boletim - Relé de proteção Sepam Ariens 921030 Snow Blower User Manual Thule Fit Kit 取扱説明書保証書付 - ご家庭のお客さま/大阪ガス 141477 CERT-CCMS User Guide.indd AM Denmark AM 80101 Manuel dʼutilisation EasyCast HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Braun Lady style User's Manual Copyright © All rights reserved.
Failed to retrieve file