1. e side of the cap Finally thread only the light pull chain through the hole in the finial and screw the finial onto the threaded rod Install a light bulb in each socket Finial Finial Cap Light Pull Chain Fan Pull Chain Globe Keeper Metal Plate Globe Note Globe style and number of lights may vary Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts its light output Exceeding the wattage limit marked on the MAX wattage sticker affixed to the light socket s may result in fire hazard or improper operation M0043 01 10 22 13 Hunter Fan Company 15 www HunterFan com 1 888 830 1326 M0043 01 10 22 13 Hunter Fan Company 16 Maintenance amp Cleaning ON Turn Power Changing the bulbs unscrew the finial and remove it from the threaded rod Remove the finial cap and unscrew the globe keeper while supporting the globe with your other hand Carefully remove the globe Unscrew bulbs and replace with bulbs of same type and wattage Reinstall the globe assembly Changing the direction of air flow move the reverse switch to the opposite position Cleaning the fan use soft brushes or cloths to prevent scratching Cleaning products may damage the finishes Reverse Switch Finial Finial Cap Globe Keeper Metal Plate Globe For questions regarding removing a light kit call cust
2. erly secure all three assembly screws could result in the light fixture falling Partially install two of the switch housing screws found in the bag Connect the plugs from the upper and lower switch housings Make sure to line up the colored markings on the connectors Align the notches in the sides of the lower switch housing with the upper switch housing screws Lift the lower switch housing Twist the lower switch housing clockwise to lock into place Then thread the fan pull chain through the hole in the light kit Install the third switch housing screw Tighten all three screws securely Switch Housing Screw Notch Switch Housing Screw Want to install your fan without a light kit Go to www HunterFan com FAQs and click How do I install my fan without the light kit 14 M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 Light Kit continued CONGRATULATIONS YOU RE DONE See next page for fan operation instructions Connect the appropriate pull chain pendant to each of the short chains coming from the finial and finial cap The fan pull chain controls the speed from high to off The light pull chain controls the light fixture on and off Press the globe and globe keeper flush against the metal plate Thread the light pull chain through the hole in the center of the finial cap and thread the fan pull chain through the hole in th
3. hten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall K E E P 1 888 830 1326 www HunterFan com 8 M0043 01 10 22 13 Hunter Fan Company 1 888 830 1326 9 M0043 01 10 22 13 Hunter Fan Company www HunterFan com Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan www HunterFan com 1 888 830 1326 Wiring F R O M F A N F R O M C E I L I N G B R A C K E T F R O M F A N Using an orange wire connector from the hardware bag connect the 3 grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and hanging bracket Grounding Green Yellow Stripe Green Yellow Stripe White Black Grounded Note To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the orange wire connectors from the hardware bag connect the black wire ungrounded from the ceiling to the black and the blue wires from the fan Connect the white wire grounded from the ceiling to the white wire from the fan Using the o
4. omer service 1 888 830 1326 www HunterFan com 1 888 830 1326 M0043 01 10 22 13 Hunter Fan Company 17 Troubleshooting Excessive wobbling Tighten all of the blade and blade iron screws until they are snug Turn the power off support the fan carefully and check that the hanger ball is properly seated Use the provided balancing kit and instructions to balance the fan Noisy Operation Tighten the blade and blade iron screws until they are snug Check to see if any of the blades are cracked If so replace all of the blades Fan doesn t work Make sure power switch is on Pull the pull chain to make sure it is on Push the motor reversing switch firmly left or right to ensure that it is engaged Check the circuit breaker to ensure the power is turned on Make sure the blades spin freely Turn off power from the circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 10 Check the plug connection in the switch housing Lights dim when turned on or do not turn on at all Make sure the wattage of the light bulbs installed matches the specifications on the light sockets
5. oward ceiling PLACE against wall 1 FOLD on dotted line 34 Use the three steps below to determine if your ceiling angle is greater than 34 Support Structure Ceiling Outlet Box required Angled Mounting Style Standard Mounting Style Support Structure Ceiling Outlet Box required M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 www HunterFan com Ceiling Bracket OFF Make sure all four 4 bumpers are still attached For angled ceilings point opening toward peak Refer to warning w 1 on pg 2 To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location If you are unable to do this call Technical Support at 1 888 830 1326 Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is acceptable for fan support of 31 8 kg 70 lbs or less Turn Power 5 M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 Ceiling Bracket continued Preparation 1 888 830 1326 ww
6. r blades are shielded with Dust Armor which is a nanotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes 12 Insert grommets found in the hardware bag into the holes in the blades then secure each blade to a blade iron with screws found in the hardware bag Remember the screws that you kept after removing the shipping blocks page 6 You need them for this step Lightly attach the blade irons to the motor with the blade iron armature screws then securely tighten after both screws are attached www HunterFan com 1 888 830 1326 Feed the wire plug through the center hole of the upper switch housing then wrap keyhole slots around the screws and twist counterclockwise Screw two 2 housing assembly screws from the hardware bag halfway into the motor housing It does not matter which two screw holes you choose Insert the third screw found in the hardware bag into place and then tighten all three 3 screws Make sure the upper switch housing is securely attached to the mounting plate Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling Switch Housing 13 M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 Light Kit Make sure the lower switch housing is securely attached to the upper switch housing Failure to prop
7. range wire connectors from the hardware bag connect the white wire grounded from the ceiling to the white wire from the fan Connect the black wire ungrounded from the ceiling to the black wire from the fan Connect the second ungrounded wire from the ceiling to the blue wire from the fan F R O M F A N White Ungrounded Black Blue Grounded F R O M C E I L I N G Ungrounded Blue For Dual Switches For a Single Switch F R O M C E I L I N G F R O M C E I L I N G Turn the splices upward and push them carefully back through the hanger bracket into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box Refer to CAUTION c 1 on pg 2 10 M0043 01 10 22 13 Hunter Fan Company Ungrounded www HunterFan com 1 888 830 1326 11 M0043 01 10 22 13 Hunter Fan Company Canopy Lift the canopy into place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Screw Holes Insert the two canopy screws found in the hardware bag Note Fan style may vary www HunterFan com 1 888 830 1326 M0043 01 10 22 13 Hunter Fan Company Blades You
8. rod for fans installed close to ceiling Longer Downrod for ceilings 10 feet or higher 2 Ceiling angles greater than 34 will require an Angled Mounting Kit See page 4 for details www HunterFan com 1 888 830 1326 Tools Needed Ladder Power Drill optional 9 64 Drill Bit optional Screwdrivers Pliers Wire Strippers If mounting to a support structure you will also need these tools 3 M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 4 M0043 01 10 22 13 Hunter Fan Company 1 866 268 1936 If you have an angled ceiling 1 You will need a longer downrod sold separately 2 If your ceiling angle is greater than 34 you will also need an Angled Mounting Kit sold separately Guide Touches BOTH Ceiling amp Wall S I T U A T I O N 1 Guide Touches Wall but NOT Ceiling S I T U A T I O N 2 You need BOTH a Longer Downrod amp an Angled Mounting Kit You need ONLY a Longer Downrod most common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting or Low Profile Mounting to hang the fan from a flat ceiling Use Angled Mounting to hang the fan from a vaulted or angled ceiling 4 34 O CEILING WALL OPTION 1 Standard Mounting OPTION 2 Angled Mounting 2 3 SLIDE t
9. tom edge of blade to the floor Select a downrod length w 1 To reduce the risk of fire electrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 70 lbs 31 8 kg and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter Solid State Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades c 1 All wiring must be in accordance with national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Hunter replacement parts Assess ceiling angle Read and Save These Instructions This product conforms to UL Standard 507 WARNINGS CAUTIONS Must be able to secure the fan to building structure or fan rated outlet box 1 2 3 Standard Downrod for ceilings 8 10 feet high Shorter Down
10. w HunterFan com D I S C A R D K E E P Remove the shipping blocks from the motor Save the screws They will be needed for blade iron installation Note Some fans will have a shipping ring instead of shipping blocks Please remove the ring and save the screws Time Saver Tip Get a helper to insert grommets found in the hardware bag into the blades while you re doing the next couple of steps 6 M0043 01 10 22 13 Hunter Fan Company 1 888 830 1326 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings 10 or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for ceilings 8 10 high Option 1 Option 2 Option 3 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe Included pre assembled www HunterFan com 7 M0043 01 10 22 13 Hunter Fan Company KEEP 8 3 8 C U T amp S T R I P not to scale Remove the pre installed setscrew so that the downrod can be inserted Hand tighten the downrod at least 4 5 full turns until it stops The wires can be cut but leave at least 8 extending from the top of the downrod Downrod continued 8 3 8 Tig
11. www HunterFan com 1 888 830 1326 PAG E 7 PAG E 13 PAG E 10 PAG E 5 PAG E 6 30 inches 7 feet PAG E 2 What to Expect with Your Installation Ceiling Bracket Ladder PAG E 3 Tools Needed Wiring Canopy Maintenance amp Cleaning Blades Troubleshooting Downrod Switch Housing Light Kit Preparation Table of Contents PAG E 11 PAG E 12 PAG E 4 Mounting Options PAG E 14 PAG E 16 PAG E 17 Congratulations on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world To register your fan please visit www HunterFan com register Save your receipt for proof of purchase 1 M0043 01 10 22 13 Hunter Fan Company www HunterFan com 1 888 830 1326 M0043 01 10 22 13 Hunter Fan Company 1 888 830 1326 1 888 830 1326 What to Expect with Your Installation Know your wiring If you are unfamiliar with wiring use a qualified electrician You may need a friend to help you Check box to see fan weight Assess location 30 inches from blade tip to nearest wall or obstruction 7 feet from bot

Download Pdf Manuals

image

Related Search

Related Contents

  Parrot RKi8400  Z Series Inverter Split Air Conditioning ECO1850SD  Nintendo 3DS Downloadable Instruction Book  Scarica il manuale del Samsung D100  ステアリング取替説明書及び取扱説明書  IBM SPSS Conjoint 19 - Universidad Complutense de Madrid  自動照明付化粧鏡 化粧鏡  EŒIIËIIVIËSTIËTÜIËIN  Notion de référentiel - pontonniers  