Home
Vornado 630B air circulator
Contents
1. TD eSHOOtiING Problem Unit fails to power on Airflow is weak or slow Possible Cause and Solution Unit is not plugged in Plug Power Cord into electrical outlet Ensure unit fan speed setting is selected Plug fuse has blown Replace fuse See USER SERVICING INSTRUCTIONS on page 4 Unit is damaged or in need of repair Cease usage and unplug Contact Consumer Service for assistance The outlet is worn or damaged Try another outlet or contact a qualified electrician Unit set to a low speed setting Adjust to a higher speed setting Airflow is blocked Remove obstruction Adjust direction of airflow towards the user English 13 kk ko Whole Room Circulator 5 Year Limited Warranty Term 10 Year Limited Warranty Models 735 745 795 5 Year Limited Warranty All Other Vornado Whole Room Air Circulator Models Vornado Air LLC Vornado warrants to the original consumer or purchaser this Vornado Air Circulator Product is free from defects in material or workmanship for a period of five 5 or ten 10 years from the date of purchase depending on model If any such defect is discovered within the warranty period Vornado at its discretion will repair or replace the Product at no cost Repairs not covered by the warranty or outside the warranty period will require a fee to cover the cost of materials labor handling and shipping This warranty does not apply to defects resulting from abuse of the Produc
2. Home Office Hearth Room Dining Room Average Bedroom Living Room Master Bedroom Family Room Recreation Room Workshop Hobby Room Sunroom Gri Removal WARNING To avoid risk of fire electrical shock or injury to persons unplug Models 533 633 753 Remove the 3 screws located in between the ribs the Air Circulator before removing the grill of the inlet grill at roughly 10 2 and 6 o clock positions Screw locations are indicated by an arrow on the side of air inlet B Do Not remove the 2 screws Models 510 530 610 630 723 733 743 783 735 745 795 Remove on the pivot arms Place the circulator facing you Position your hands at the the screw only necessary on model 530 Depress one of the grill clips A by 10 and 2 o clock positions lift up and back on the outer grill to release the grill placing your thumb against the outside surface of the clip and pressing down clips C If necessary repeat the process against the remaining two clips at ward towards the motor applying slight pressure forward A flathead screw the 5 and 7 o clock positions Replace by lining up the clips with the holes and driver can also be used if the clips are difficult to release Usually by releasing firmly snapping the grill back into place Replace all the screws one clip the grill can be removed If the grill cannot be removed repeat the process on remaining clips Replace by lining up the clips with the holes and firmly snapping the g
3. Airflow Energy Savings Adjustable Height Benefit With multiple speeds any circulation need will be met To turn on unit rotate knob one position clockwise Turn the knob clockwise to decrease airflow Turn coun terclockwise to increase airflow On models equipped with push button speed controls Press Power then select speed Provides movement of air at any angle up stairs down a hallway room to room and everywhere in between Models V102 270 573 673 and 679 provide movement of air in two positions vertically or horizontally Saves energy by maximizing the performance of heating and cooling systems When you use a Vornado Air Circulator you will not have to set your summertime thermostat as low or your wintertime thermostat as high Model 783 and 795 only 28 or 40 heights make this model perfect for out of the way placement behind furniture and office fur nishings The extension tube must be used to achieve the 40 height To shorten the height of the circulator remove the extension tube See the Adjustable Height assembly instructions in the shipping carton Assemb Installing Protective Feet Use the feet to protect floors when using your air circulator on uncarpeted surfaces such as hardwood vinyl or tile The feet are simple to install and will help maintain the whisper quiet operation Cushion Ring Feet Models 723 745 783 and 795 only I The cushion ring feet are packaged separ
4. a Y VORNADO 24 160 READ AND SAVE THESE IMPORTANT INSTRUCTIONS Whole Room Air Circulator Owner s Guide LEA Y TENGA EN CUENTA ESTAS INSTRUCCIONES IMPORTANTES Gu a del propietario del Circulador de Aire para toda la habitaci n LIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES models VH102 133 160 270 Guide de l utilisateur du ventilateur int gral de piece 360 510 530 533 573 610 630 6331060 073 679 123 203 190 www vornado com 743 745 783 783 795 2 English Designed engineered and supported in Andover Kansas Pensado disenado y respaldado en Andover Kansas Conception mise au point et soutien technique effectu s a Andover au Kansas O www vornado com Questions or comments Prequntas o comentarios Za consumerservice vornado com Questions ou commentaires CoP 800 234 0604 TSS 92T dl da sscian ascii 4 Whole Room Circula to Mica N 6 AS 7 o A Eo E O eee en ere ere A 7 HOW TO SS aiH das 8 E eo reese se Se vada S 9 A sees 12 Cleaning and Maintenance sese esse eee 12 TOUDIESROO A O 13 ME TANG caso o apne erecta ee rere E A anes ee 14 Contents Espanol p 15 Francais p 27 English 3 IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING This appliance has a polarized plug One blade is wider than the other To reduce the risk of electrical shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it st
5. ately in the box To install roll or clip all feet onto the t base and space evenly For balanced support it is recommended to use 4 ring feet Cushion Pads Model 733 and 735 only Use guide marks on base bottom for location 1 Place 4 pads over the 4 edge bends 2 Place 2 pads on each of the curved ends Base Assembly Model 743 only 1 Align the pins A located on each base piece and insert into the holes B on each base piece 2 Align and insert pivot knob C into hole located on the base D 3 Place rubber washer E onto pivot knob Then screw pivot knob into the head of unit F until secure Repeat on opposite side of the base English 7 How lo Use When To Use Saves Energy Year Round Summer Use your Air Circulator with your homes air conditioning system to create brisk comforting air movement This breeze will eliminate stagnant air and remove body heat to make you feel cooler With Vornado Air Circulators you can save money on energy bills by raising your thermostat several degrees and still maintaining the same comfort level Push cool air up stairs Use with central or window air conditioning Spring amp Fall Your Air Circulator can make the indoors as fresh and pleasant as the outdoors Place the Air Circulator near an open window sliding door or French door to take full advantage of mild temperatures and seasonal breezes Even room temperature Circulate fresh outdoor ai
6. desired operation This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada SAVE THESE INSTRUCTIONS English 5 Trust Whole Room Circulation It is said that trust isn t given but earned For decades Vornado has Maximize your cooling efficiency been earning the trust of our customers by offering them only the best Vornado provides the highest level of performance coupled with the highest level of support available Complete satisfaction with no exceptions this is Vornado s promise to you If you are not satisfied for any reason please contact us Knowledgeable representatives are available at 1 800 234 0604 from 7 00 AM to 6 00 PM CST A wealth of additional support is also available online at www vornado com On behalf of myself and the entire staff at our Andover Kansas headquarters thank you for selecting Vornado Sincerely Bill Phillips CEO Vornado Air Typical Fan Vornado Air Circulator A Vornado circulates all the air in the room so everyone is comfortable Air in motion feels cooler than air that is stagnant By providing whole room circulation a Vornado allows you to turn the thermostat up 5 F saving energy and money without sacrificing comfort see it in action e L e VORTEX CIRCULATOR Find our complete product line at www vornado com 6 English Multiple Speeds Q br 7 Directable
7. easing the grill To reattach po sition grill so the logo in the center of the grill is straight and replace the 2 screws CG ri Removal Model 660 The grill on your model will be able to be removed in one of Models V102 270 s Remove the screw located at the 6 o clock position Ro two ways Check the back of unit and follow Instructions A if you do not have tate the grill counter clockwise to unlock and then lift off To reinstall the grill buttons along the side Follow Instructions B if you do have buttons along the position the grill with the logo slightly turned to the left and rotate clockwise side of unit Replace the screw Instruction A Remove the 3 screws as indicated Replace by lining up the holes and replacing all 3 screws securely into place Models 573 673 679 Remove the 8 screws around the perimeter of the frame and lift off To reinstall the grill line up screw holes and replace screws I 4 Instructions B Remove screw on the bottom of head of unit on the left side of the chrome glide bar Depress the 3 buttons D to release the grill Replace by lining up the buttons with the holes and firmly snapping the grill back into place Replace the screw English 11 Remove the Nut 12 English It is possible to r
8. emove the blade should something accidentally get wrapped around the motor shaft First remove the nut from the shaft only necessary on V102 133 270 573 533 633 673 679 743 and 753 models Turn the nut clockwise to loosen Pull the blade straight out from the shaft When replacing the blade can only go on the shaft one way Be certain the flat side of the shaft aligns directly with the cor responding flat side on the blade s socket Push the blade all the way on the shaft until it bottoms out Do not use a hammer as this could result in bearing dam age Reinstall nut on applicable models O e g A C d O g Because your Air Circulator moves a substantial amount of air it will need regular cleaning To avoid risk of fire electrical shock or injury to persons unplug the unit before any cleaning activity The motor is permanently lubricated and requires no oiling To clean motor cap and inlet ribs Use a com mon household vacuum Do not use water to clean these parts of the Air Circulator To clean grill Remove grill See GRILL RE MOVAL instructions and dust or wash with a mild dishwashing soap Do not place grill in the dishwasher The excessive heat can distort the plastic To clean blade Wipe with a damp cloth If your Air Circulator is used in a greasy environment such as a kitchen mild soap or a common household cleaner may be necessary Do not use solvents To clean base Wipe with a damp cloth
9. ence please have your model number and serial number when contact ing Vornado with service inquiries To assure proper handling packages must be clearly marked with the RA number Packages not clearly marked with the RA number may be refused at the receiving dock Please allow 1 2 weeks for repair and return of your Product after the Product is received For your records Staple or attach your original sales receipt to this Owner s Guide Please also write your products s serial number below located on product specs decal Serial No o Product registration available online at www vornado com O 2009 Vornado Air LLC Andover KS 67002 Patent Pending Specifications subject to change without notice Vornado is a trademark owned by Vornado Air LLC www vornado com consumerservice vornado com 800 234 0604 Notes e Vornado Air LLC Vi RN D 415 East 13th Street Andover Kansas 67002 800 234 0604 www vornado com Speak your mind www vornado com reviews Hable con franqueza www vornado com reviews Evaluer ce produit en ligne www vornado com reviews CL3 0071 RK CL7 0071 RK VO1
10. g the cover back into the plug until it is completely closed latches and is flush with the face of the plug Risk of fire Do not re place attachment plug Contains a safety device fuse AFCI LCDI that should not be removed Discard product if the attachment plug is damaged Models 660 amp 270 only Note This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 his device must accept any interference received including interference that may cause un
11. ill does not fit contact a qualified elec trician Do not attempt to defeat this safety feature WARNING To reduce the risk of fire or electrical shock do not use this product with any solid state speed control device To reduce the risk of fire or electric shock and injury to persons do not use ina window This product employs overload protection fuse A blown fuse indi cates an overload or short circuit situation If the fuse blows unplug the product from the outlet Replace the fuse as per the user servicing instructions follow product marking for proper fuse rating and check the product If the replacement fuse blows a short circuit may be present and the product should be discarded or returned to an autho rized service facility for examination and or repair Do unplug your circulator before cleaning Do clean your Vornado Air Circulator regularly Refer to the CLEAN ING instructions provided Never clean the air circulator in any man ner other than as instructed in this manual Do Not use gasoline thinners solvents ammonias or other chemi cals for cleaning Do Not immerse this product in water or allow water to drip into the motor housing Do Not use near furnaces fireplaces stoves or other high temper 4 English ature heat sources Do Not position this product too close to draperies because they may be drawn into the rear grill cutting off airflow Do Not use this product outdoors Do Not use this produc
12. r Winter Position your Air Circulator in a place with unobstructed upward air movement Run it only as fast as necessary to lower the heated air from the ceiling but not fast enough to create a draft Or use your Air Circulator with other available heat sources furnace vents wood stoves or baseboard heat ers to circulate their warmth taking full advantage of all available heat in the room Do not point the Air Circulator at open flames Replace cold floor air with warm ceiling air Increase the efficiency of heating sources 8 English Getting Started 1 Position your Air Circulator so the beam of air has an unobstructed path from one side of the room to the other 2 Set speed to medium and allow a few minutes for an airflow pattern to be established Different airflow patterns can be established by changing the location angle and speed of the Air Circulator 3 Adjust the speed accordingly until a desired comfort level is achieved You will quickly determine the precise amount of circula tion required to maintain your personal comfort in a given room for the prevailing temperature and humidity conditions Once you discover the added comfort of air circulation you will use your Vornado Air Circulator season after season Where to Use Air Circulator 100 300 and 500 series 600 series 660 V102 270 and 700 series Ideal Rooms Kitchen Smaller Bedroom Dorm Room Office Cubicle Den
13. rill back into place Replace the screw model 530 only Screw J 530 only o English 9 Model 133 Remove the 4 screws located at the back at the outer most edge of the inlet grill at roughly 2 5 7 and 11 o clock positions releasing the grill To reattach position the grill so the logo in the center of the grill is straight and replace screws Model 160 Remove the 4 screws located in between the ribs of the inlet grill at roughly 12 3 6 and 9 o clock positions releasing the grill To reattach po sition grill so the logo in the center of the grill is straight and replace screws 10 English Model 360 The grill on your model will be able to be removed in one of two ways Check the back of your unit to see how many screws your unit has and follow the appropriate instructions Instruction A s Feel for bumps on back of product close to inlets that help to locate screws at roughly 12 3 6 and 9 o clock positions Remove the 4 screws located at these positions releasing the grill To reattach position grill so the logo in the center of the grill is straight and replace screws OW ZZ Instruction B s Remove the 2 screws located in between the ribs of the inlet grill at roughly 9 and 3 o clock positions rel
14. t modification alteration repair or service of the Product by anyone other than Vornado mishandling improper maintenance commercial use of the Product damages which occur in shipment or are attributed to acts of God REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VORNADO SHALL NOT BE LIABLE FOR ANY INCIDEN TAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential dam ages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights that vary from state to state 14 English For warranty or repair service call 1 800 234 0604 or email consumerservice vornado com to obtain a Return Authorization RA form Please have or include your Products model number and serial number as well as your name address city state zip code and phone number when contacting Vornado for warranty service After receiving the RA form ship your Product to Vornado Air LLC Attn Warranty amp Repair 415 East 13th Street Andover KS 67002 For your conveni
15. t on wet surfaces Do Not use this product in a bathtub or shower Do Not operate any fan with a damaged cord or plug Discard fan or return to an authorized service facility for examination and or repair Do Not carry this product by the cord or use the cord as a handle Do Not attempt to repair or replace parts Do Not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furni ture or appliances Arrange cord away from traffic area and where it will not be tripped over Do use common sense when using this product and or any electri cal appliance User Servicing Instructions Grasp plug and remove from the receptacle or other outlet device Do not unplug by pulling on cord Open fuse cover A by sliding access cover on top of attachment plug towards blades Remove fuse carefully B by gently prying out the ends of the fuse from the recep tacle Risk of fire Replace fuse only with 2 5 Amp 125 Volt fuse IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING Contact Vornado customer service for replacement fuse Phone 1 800 234 0604 email consumerservice vornado com Install replacement fuse C by first placing the end of the fuse into the fuse receptacle which is opposite of the blades of the plug then carefully push in the other end Only push against the metal end of the fuse not the glass center portion Close the fuse access cover D by slidin
Download Pdf Manuals
Related Search
Related Contents
Parasound HALO JC 3 User's Manual ISAN User Guide LauraStar S7a 取扱説明書 - M HCM160b - Version 1.cdr Service Manual TMB11/TS03 DECmagtape system user`s manual Istruzioni per l`uso - Mediatec Informatica Srl. Kramer Electronics 1m, HDMI - HDMI Copyright © All rights reserved.
Failed to retrieve file