Home
Asrock 2U12L6SC-2TS6 server barebone
Contents
1. Power Connector PWR1 MW BR wlrm rR SGPIO Connector SGPIO1 21 22 Pin Definitions 1 Intelligent Platform Management Bus Header SMB_1 This 4 pin connector PMB SMBDATA provides a communication GND interface between the IPMB_SMBCLK backplane and the 3VSB motherboard It allows 12C_1_PRESENT_N basic monitoring of voltages fans and temperature 2 Mini SAS Connector MINI_SAS1 This connector is used to connect RAID card or L the mini SAS port on the motherboard 3 Debug Connector DEBUG 1 The Debug Connector is used for the firmware upgrade and Debug Bory factory reset GND 4 Power Connector 12V The 4 pin connectors PWRI1 ene provide power to the ae backplane 5V 5 Serial General Purpose scrocx JOO This header supports Input Output Header soa tOlOL eno Serial Link interface SGPIO_1 enn O C4 spataouto for onboard SATA SDATAINO connections BP_S2x1_25 to connect 2 SSDs Front View 2x SAS SATA Hot swap Connectors S _ CON1 Rear View 1 2 3 4 EEE Ir SGPIO1 SAS2 7 Ji DEBUG 1 SAS1 i PWR SMB_1 5 Power Connector PWR1 SGPIO Connector SGPIO1 SAS Connector SAS2 Debug Connector DEBUG SAS Connector SAS1 Din BR wl mle Intelligent Platform Management Bus Header
2. 1 Unscrew the two screws from the sides of the chassis cover 2 Unscrew the two screws from the back side of the chassis cover 3 Press the release tabs to remove the cover from the locked position Press both tabs at the same time 4 Once the top cover is released from the locked position slide the cover outward 5 Lift the top cover off the chassis Installing the Chassis Cover Slide the chassis cover toward the front of the chassis 1 Then latch the cover securely to the chassis 2 Secure the chassis cover with the screws 3 2 Hard Drives The 2U12L6SC chassis supports hot swappable hard drives Removing Hard Drive Trays from the Chassis 1 Press the locking lever latch on the drive tray to unlock the retention lever 2 Rotate the lever out and away from the module bay and pull the hard drive out of the HDD carrier Installing a Hard Drive to the Hard Drive Tray I Place the HDD into the tray with the printed circuit board side facing down Carefully align the mounting holes in the hard drive and the tray Secure the hard drive using the four screws Slide the drive tray into the HDD bay until the drive is fully seated Push in the locking lever to lock the HDD tray into place 10 3 3 System Fan Before replacing the system fan power off the server and unplug the power cord Replacing the System Fan Hold the clip and put the fan module into fan bar Push all the way until it click
3. 2U12L6SC Chapter 1 Introduction Thank you for purchasing 2U12L6SC a reliable barebone system produced under ASRockRack s consistently stringent quality control It delivers excellent performance with robust design conforming to ASRockRack s commitment to quality and endurance Because the hardware specifications might be updated the content of this documentation will be subject to change without notice In case any modifications of this documentation occur the updated version will be available on ASRockRack s website without further notice If you require technical support related to this product please visit our website for specific information about the model you are using ASRockRack s Website www ASRockRack com The illustrations shown in this manual are examples only the actual system may differ slightly 1 1 Package Contents 2U12L6SC 2U Form Factor Power Supply Unit pre installed System Fan pre installed HDD Backplanes x 3 pre installed Chassis Cables Screws x 72 includes 24ea SFF and 48ea LFF User Manual Ai If any items are missing or appear damaged contact your authorized dealer Chapter 2 Chassis Overview This chapter provides diagrams showing the location of important components of the server chassis 2 1 System Components Cover fe Sh Power Supply Units Air Baffle M B Front Controls and Indicators 2 2 System Front View Front
4. OPEN GREEN STABLE Industry Standard Flexible Architecture Less Heat Less Power Consumption Robust Design Quality Parts ASRock Rack Stable and Reliable Solution 2UT2LOSC User Manual Version 1 0 Published August 2013 Copyright 2013 ASRockRack Inc All rights reserved Copyright Notice No part of this documentation may be reproduced transcribed transmitted or translated in any language in any form or by any means except duplication of documentation by the purchaser for backup purpose without written consent of ASRockRack Inc Products and corporate names appearing in this documentation may or may not be registered trademarks or copyrights of their respective companies and are used only for identification or explanation and to the owners benefit without intent to infringe Disclaimer Specifications and information contained in this documentation are furnished for informational use only and subject to change without notice and should not be constructed as a commitment by ASRockRack ASRockRack assumes no responsibility for any errors or omissions that may appear in this documentation With respect to the contents of this documentation ASRockRack does not provide warranty of any kind either expressed or implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpos
5. qualified and certified personnel only to avoid risk of injury from electrical shock or energy hazard Disconnect the power cord from the wall outlet when installing or removing main system components such as the motherboard and power supply unit Place the system on a stable and flat surface Use extreme caution when working with high voltage components When handling parts use a grounded wrist strap designed to prevent static discharge Keep the area around the system clean and clutter free Keep all components and printed circuit boards PCBs in their antistatic bags when not in use Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts Contact Information If you need to contact ASRockRack or want to know more about ASRockRack you re welcome to visit ASRockRack s website at www ASRockRack com or you may contact your dealer for further information ASRockRack Incorporation 6F No 37 Sec 2 Jhongyang S Rd Beitou District Taipei City 112 Taiwan R O C Contents Chapter 1 Introduction 1 1 Package Contents Chapter 2 Chassis Overview 2 1 System Components 2 2 System Front View 2 3 System Rear View Chapter 3 Hardware Installation and Maintenance 3 1 Chassis Cover 3 2 Hard Drives 3 3 System Fan 3 4 Power Supply 3 5 Backplanes 3 6 Add on Card 3 7 Chassis Cables Chapter 4 Backplane Specifications Appendix A Rails Installation 18 26
6. when a jumper cap is placed on these 2 pins yy v Short Open 9 UART Jumper 1 2 UART_SEL Configure the setting of Debug connector for updating firmware by SDB_TX RX 2 3 Default Configure the setting of Debug connector for updating debug console by UART Pin Definitions 1 2 10 11 Power Connector PWRI1 sN PWR2 GND1 PWR3 GND2 PWR4 12V The 4 pin connectors provide power to the backplane 3 4 Mini SAS m m Connector MINI_SAS1 MINI_SAS2 This connector is used to connect RAID card or the mini SAS port on the motherboard 19 20 5 6 7 SMB Connector The SMB SubMiniature SMB_1 version B connector SMB_2 SDA provides a communication SMB_3 GND interface between the a backplane and the 3VSB rant motherboard 8 Debug Connector TE ND The Debug Connector is used DEBUG RX for the firmware upgrade and 3V factory reset 2 5 inch Hard Drive Backplane to connect 4 HDDs BP_S2x2_25 to connect 4 HDDs Front View S _ 5 CON2 Sas CON1 u CON4 CON3 2 x SAS SATA Hot swap Connectors Rear View oh sme saion EEE DEBUG 1 Eh MINI_SAST ASRock BP_S2x2_25 pwRi Intelligent Platform Management Bus Header SMB_1 Mini SAS Connector MINI_SAS1 Debug Connector DEBUGI1
7. you want to use Keep this screw for later use 2 Align the add on card and insert into place Secure each card to the chassis using the screw previously removed 15 16 3 7 Chassis Cables This section lists supported cables for your chassis system 1 Single port SATA Cable Quantity 2 n rer RSE III iF SOO 6 MNG Cable 520mm 100mm _SMB Quantity 1 18 Chapter 4 Backplane Specifications 3 5 inch Hard Drive Backplane to connect 12 HDDs BP_2x20_S3x4 Front View COM ey CON2 ES CON3 CONS eS CONS SS CON7 conog CON CONTI 12 x SAS SATA Hot swap Connectors Rear View con gt SS CONS SS SS con SS ASRock BP_2x20_S 3x4 Power Connector PWR2 Power Connector PWR4 Mini SAS Connector MINI_SAS1 Mini SAS Connector MINI_SAS2 SMB Connector SMB_1 SMB Connector SMB_3 SMB Connector SMB_2 Debug Connector DEBUGI1 OL OINIT DAD WP w rme re UART Jumper UART_SEL1 j i Power Connector PWR1 Power Connector PWR3 Jumper Setup The illustration shows how jumpers are setup When the jumper cap is placed on the pins the jumper is Short If no jumper cap is placed on the pins the jumper is Open The illustration shows a 3 pin jumper whose pin and pin2 are Short
8. Control Panel HO ROC ge aa eS SE US Same Us Sane SS Samer US g gl 33h 2E Pek Sea Jefe Seperate Je Sea Jeo cr E _S _ d O P ae E lO et E dl EE l EE G E l E e 1 System reset button 2 Power LED 3 Power Switch 4 LANI LAN2 Activity LED 5 12 x 3 5 Hot Swap HDD Carriers Status LED Definitions Power LED Status Description Blue System is turned on Off Power off LAN1 LAN2 LED Status Description Green LAN linked off LAN not linked 2 3 System Rear View OOo000000 OOoO00000 Ch i oaoa Po oP 0 0a Po 0 00 DVO KOKO 0 O70 O O CONC Power supply unit 6 x 2 5 Hot Swap HDD Carriers 3 x Low Profile PCI Express slots T O shield depends on the specification of the motherboard 2 3 4 Chapter 3 Hardware Installation and Maintenance This chapter helps you assemble the chassis and install components 3 1 Chassis Cover Removing the Chassis Cover 1 Before removing the top cover power off the server and unplug the power cord 2 The system must be operated with the chassis top cover installed to ensure proper cooling
9. SMB_1 23 Pin Definitions 1 Power Connector The 4 pin connectors 12V PWRI1 GND provide power to the back GND1 plane 5V 2 Serial General SCLOCK This header supports Serial Purpose Input Output Header SGPIO_1 Link interface for onboard SATA connections SDATAOUTO SDATAINO 3 5 SAS Connectors These two SAS connectors SAS1 SAS2 I Ia support SAS SATA data SAS_2 SAS_1 E cables for internal storage devices The current SAS2 SATA3 interface allows up to 6 0 Gb s data transfer rate 4 Debug Connector 1 The Debug Connector is used for DEBUGI the firmware upgrade and factory Debug Doty reset GND 24 2U12L6SC 6 Intelligent Platform Management Bus Header SMB_1 IPMB_SMBDATA This 4 pin connector IND IPMB_SMBCLK provides a communication 3VSB 12C_1_PRESENT_N backplane and the interface between the motherboard It allows basic monitoring of voltages fans and temperature 25 26 Rear LED Indicators Status Green Orange Blue Drive Not Present Off Off Off Drive Present No Activity On Off On Drive Present Activity Blinking Off On Locate Identify Off Blinking On Drive Fail Off Off Off Rebuild Blinking Blinking On Front LED Indicators Drive Not Present Off Off Off Off Off Drive Present No Activity Off On Off Off On Drive Present Activity Off O
10. below Optional Accessory Slide Rail Kit Vendor Model name Chenbro 84H341300 002 29
11. e In no event shall ASRockRack its directors officers employees or agents be liable for any indirect special incidental or consequential damages including damages for loss of profits loss of business loss of data interruption of business and the like even if ASRockRack has been advised of the possibility of such damages arising from any defect or error in the documentation or product FE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CALIFORNIA USA ONLY The Lithium battery adopted on this motherboard contains Perchlorate a toxic substance controlled in Perchlorate Best Management Practices BMP regulations passed by the California Legislature When you discard the Lithium battery in California USA please follow the related regulations in advance Perchlorate Material special handling may apply see www dtsc ca gov hazardouswaste perchlorate ASRockRack s Website www ASRockRack com Important Safety Instructions Pay close attention to the following safety instructions before performing any of the operation Basic safety precautions should be followed to protect yourself from harm and the product from damage Operation of the product should be carried out by suitably trained
12. ff Blinking Off On Locate Identify Off Off Off Blink On Drive Fail Off Off Off Off Off Rebuild Off Off Blinking Blinking On PFA Predicted Failure Analysis Off On Off Blinking Off Hotspare Off Off Off Off Off In A Critical Array Off On Off Blinking Off In A Failed Array Off On Off Blinking Off Blink Freq Blink Freq 0 25 s 0 5s Appendix A Rails Installation The rails installation instructions in this manual are example only your actual rail assembly procedure may differ slightly Installing the Rails 1 Pull out the inner rail from rail assembly by pulling the front activating release latch forward 2 Secure the inner rails directly to the sides of the chassis using screws 27 28 3 Each slide is pre attached with front and rear adjustable EIA brackets Loosen the nuts on the both brackets and decide the proper setback distance to the opening then tighten the nuts on the front brackets A V2 4 Extend the rear brackets to where it reaches the rear rack Do not fully tighten rear bracket mounting screws until final adjustment is made Repeat Step 3 amp 4 above for other side of outer slide member 5 Attach the L shaped bracket to the front mounting flange using screws and nylon ring Repeat Step 5 for the other side of slide OO 59 ep CCCOCCCOCOCCOCO A 2U12L6SC Optional Slide Rail Kit The optional slide rail kit is available for you to order as listed
13. s into place 2U12L6SC 3 4 Power Supply Before replacing the power supply power off the server unplug the power cord and disconnect all wiring from the power supply Replacing the Power Supply Redundant 1 Slide the PSU into the power supply module bay until it clicks into place 2 Use six screws to fix whole PSU assembly on the chassis 11 12 3 5 Backplanes Each barebone system supports one 3 5 inch HDD backplane and two 2 5 inch HDD SDD backplanes The Hot Swap SAS SATA backplanes serve as the interface between the motherboard and the HDDs SDDs Before removing and installing backplanes power off the server and unplug the power cord For the specification of backplanes please refer to the Chapter 4 Removing the Backplane 1 Loosen the securing screws on the backplane 2 Lift the backplane up from the chassis 2U12L6SC Installing the Backplane 1 Hold the backplane only by the edges 2 Position the backplane in the server system Align mounting holes of backplane to the standoff on the chassis 3 Secure the backplane with the four screw 13 14 The following diagram shows the location of blackplanes on the server chassis 2U12L6SC 3 6 Add on Card AN Before installing the add on card power off the server and unplug the power cord Installing the Add on Card in the Chassis 1 Remove the screw securing the cover in place for each low profile add on slot
Download Pdf Manuals
Related Search
Related Contents
My Maersk Line Untitled - M Manual de Instalación y Operación STEVAL-IFN003V1 - STMicroelectronics Tripp Lite White USB Sync / Charge Cable with Lightning Connector, 3-ft. (1M) Untitled - Quantuum Informaciones de equipo Mode d`emploi DMK avec IC Capture MODE D`EMPLOI MANUAL English - Alientech Copyright © All rights reserved.