Home

EK Water Blocks 3831109840665 hardware cooling accessory

image

Contents

1. Installation and mounting manual for EK BAY Res D5 reservoir This product is intended for installation only by expert users Please consult with a qualified technician for installation Improper installation may result in damage to your equipment EK Water Blocks assumes no liability whatsoever expressed or implied for the use of these products nor their installation The following instructions are subject to change without notice Please visit our web site at www ekwb com for updates Before installation of this product please read important notice disclosure and warranty conditions printed on the back of the box The barb hose fittings require only a small amount of force to screw them in otherwise the high flow fittings might break These fittings do not need to be tightened with much force because the liquid seal is made using O rings The use of an algaecide and corrosion inhibitors is always recommended for any liquid cooling system G 3 8 threaded fill port Acrylic front plate POM Acetal reservoir body Vibration Damper MIN MAX indicator EK BAY Res D5 reservoir is only compatible with the Xylem Laing D5 pump Before installation remove main pump motor body from the stock or any other third party pump top Take your Xylem Laing D5 pump Place it according to the picture Do not forget to place the O ring accordingly Use enclosed Allen key to secure the pump with eight 8 M4x16 DIN7380 screws
2. Do not use excessive force when tightening the screws Overtightening the screws will stripp the M4 threads rendering the product useless Placing the O ring M4x16 DIN7380 screw ae ae Gasket OR 60x3 D5 X TOP RING Revision 1 0 Released on 9 of December 2013 This reservoir occupies two 2 5 25 drive bay expansion slots in your computer chassis Free two slots in case they are already occupied with other computer components such as optical or hard disk drives Place the reservoir in your 5 25 drive bay with the front plate facing outwards After completing STEP 6 in this manual secure the reservoir to the drive bay cage using the enclosed eight 8 M3x4 DIN 7985 screws with Philips head screwdriver OUTLET G1 4 threaded port INLET G1 4 threaded port Fill the reservoir through G3 8 threaded fill port marked with arrow and make sure liquid is not spilled over your computer or any electrical devices nearby Run your pump shortly for few seconds couple of times to make sure water floods your tubes and other water cooling components before permanently leaving the pump on Pay attention to the water level in your reservoir Lowest and highest recommendable water levels are indicated on the reservoir s front panel MIN MAX Once done with the filling process please close your EK BAY Res D5 reservoir with G3 8 plug and tighten the seal using enclosed Allen key 6mm Now secure the bay reservoir
3. those expressly set out above and does not cover any claims for consequential loss or damage This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer This warranty is voided if the product comes in contact with aggressive UV additives or other improper liquids REQUIRED TOOLS f gt Y ff a Philips head screwdriver M3x4 DIN 7985 screw G 3 8 threaded fill port MIN MAX indicator It is mandatory to use the correct INLET and OUTLET port Please use the appropriate G1 4 threaded ports as shown on the picture below EK recommends using EK CSQ compression fittings for best water cooling experience EK CSQ compression fittings Revision 1 0 Released on 9 of December 2013
4. with M3x4 DIN 7985 screws mentioned in step 4 VERY IMPORTANT NOTICE Once the installation is completed it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer We recommend a 24 hour leak test prior to powering up the computer Do not test the water block using tap water pressure This will rupture the top of the housing and render the block unusable and will void your warranty While all efforts have been made to provide the most comprehensive tutorial possible EK Water Blocks assumes no liability expressed or implied for any consequential damage s occurring to your equipment as a result of using EK Water Blocks cooling products either due to errors or omissions on our part in the above instructions or due to failure or defect in the EK Water Blocks cooling products WARRANTY Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user During this period products will be repaired or have parts replaced at our discretion provided that I the product is returned to the agent from whom it was purchased II the product has been purchased by an end user and has not used for commercial purposes III the product has not been misused handled carelessly or used in a manner other than in accordance with the instructions provided describing its installation and proper use This warranty does not confer rights other than

Download Pdf Manuals

image

Related Search

Related Contents

consejo - Bernina  Pioneer DEH-P9650MP Stereo System User Manual  Manual: MPT-2 Autotitrator (Man0318-3.0)  LECOASPIRA 690 M0S09377 1Q06:Layout 1.qxd  UPDATE: 2014.06.30「ウイルオフ・Fanパーソナル」  Asrock E3C204-V+  Samsung Galaxy S3 Neo Benutzerhandbuch  ARTIFICES DE DIVERTISSEMENT  Supermicro CSE-SAS-743TQ  Installation & Service Manual  

Copyright © All rights reserved.
Failed to retrieve file