Home
Kam XY Laser RBP
Contents
1. INSTRUCTION MANUAL XY Laser Series Pan amp Tilt colour lasers M A N U A L V E R S I O N 2 0 17 07 13 For the latest instruction manual updates and information on the entire Kam range visit www kam co uk Kam products are manufactured by Lamba plc Unit 1 Southfields Road Dunstable Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal Due to continuous product development specifications and appearance are subject to change Copyright Lamba plc 2013 E amp OE Thank you for purchasing this Kam product we are sure that it will serve you for many years to come To optimise the performance of this product please read these operating instructions carefully to familiarise yourself with the basic operations of this unit Please retain them for future reference This unit has been tested at the factory before being shipped to you To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture To prevent a fire hazard do not expose the unit to any naked flame sources Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time When installing the unit please ensure you leave enough space around the unit for ventilation Slots and
2. lt Channel 7 X axis __ Channel 8 Y axis rotation lt s i 000 127 0 359 degrees rotation 128 191 Clockwise rotation SNGRBRIA ARA TOlaNON 192 255 Anti Clockwise rotation 000 127 0 359 degrees rotation 128 191 Clockwise rotation Channel 10 axis rotaion 192 255 Anti Clockwise rotation Pattern list in channel 2 PATTERNS PATTERNS PATTERNS PATTERNS ie Oh LU LI LI B A n lt 144 151 152 159 032 039 160 167 168 175 232 239 1 6 183 240 247 Specifications Mains input AC100V 240V 50Hz 60Hz Fuse 250v 1A slow blow 20mm glass Power consumption 15w Sound to Light music control via internal mic Scanning system 3K stepper motor Scanning angle Pan gt 120 degrees Tilt gt 90 degrees Laser classification Class 3b Laser safety standard en60825 1 2007 Operating tempreture 10 40 degrees C DMX connection 3 pin XLR DMX channels 10 Dimensions see diagram below 180 x 80 x 195mm WxHxD not including bracket Weight 2Kg Laser power RGY 100mW red 40mW green 140mW yellow RBP 100mW red 120mW blue 220mW pink GBC 40mW green 120mW blue 160mW cyan Specifications subject to change without prior notice
3. Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connetion DMX output DMX input ALR mounting sockets rear view XLR mounting plugs rear view 1 Shield 2 Signal 3 Signal Building a serial DMX chain Controller operation operation si Functions Operational Mode When laser is powered on LED monitor on rear panel shows the current operating mode Auto sound adjustment DMX slave Ren test With help of LED control panel it is very easy to set and change the operation of the laser After a setting is saved the new mode information will be shown on the LED mointor at next power on Mode Function Option to choose the operating mode laser Confirmation to confirm all the setting or change of LED control panel Operation Up Down to change operation mode parameter or DMX address N uN ir ejr mu N m Nu SLI t ENTER SLM SLS ENIERK DMX 512 1 R j 3 o eo o FUNC UP DOWN ENTER Auto mode Press the menu button until AuT is displayed In this mode all 3 colours of the laser will be displayed press menu to confirm selection While the auto mode is flashing Use the up and down buttons to scroll through the auto menu Aut1 single colour 1 Aut single colour 2 Au3 single colour 3 Sou 3 colours in sound mode Sou
4. eye From this it follows that larger and faster moving images are safer What is the best way to operate the Laser Make sure the laser projects into a public area at least 3m above the ground level preferably angled into the distance to reduce the amount of close audience scanning and not directly down into the audience Always aim for the least audience scanning particular at close quarters Scanning at a distance will reduce to a minimum the possibility of tte MPE being exceeded _ 3 Meters Avoid direct eye contact with laser beam 4 IMPORTANT 4 For your own safely and full laser safety regulation we do strongly recommend you to take this optional switch CONTROL amp FUNCTION This can be used as an emergengy fail safe And should be connected to the safety interlock plug Contents XY laser unit x1 Safety keys x2 Interlock connectiing plug x1 Remote control x1 Mains power lead x 1 User manual x1 ol ee et a The unit is supplied with a power plug appropriate to its voltage and destination Should any other connections be required they must be carried out with the following configuration L Brown E Green Yellow N Blue FUSE Smmx20mm FUSE F 1 A 250V Cable EU Cable US fo n International Light Blue White Neutral DMX 512 connection between fixtures The fixture is equipped with 3 pin XLR sockets for DMX input and output The sockets are wired in parallel
5. openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating To prevent fire hazard the openings should never be blocked or covered If the unit is powered by the mains always handle the power cable by the plug Never pull out the plug by pulling on the cable Never touch the power cable when your hands are wet as this could cause an electric shock Do not tie a knot in the cable The power cable should be placed such that it is not likely to be stepped on A damaged power cable can cause a fire or give you an electrical shock Check the power cord periodicaly if you ever find that it is damaged replace it before using the unit again Contact your retailer for a replacement The voltage of the available power supply differs according to country or region Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons Caution to prevent the risk of electric shock do not attempt to open the unit No user serviceable parts inside Refer all servicing to qualified service personnel The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions i
6. remote in Master Slave mode Set the first unit to REN mode and all other units in SLA The remote will control all units in the DMX chain Remote control The unit can be operated by the supplied remote control Make sure the unit is powered up and working if no lasers are showing press the red power button on the remote A Use this button to place the unit in standby mode when it is not needed To completely turn the unit off remove the power supply The remote control s Auto button C sets the unit to Auto mode see above The Music button B sets the unit to Sound to Light mode The two outer buttons in the second row of the remote D and E control the colour that the unit displays The middle button of the second row F pauses the effect G ABC do not have a function on this unit 1 9 selects pre programmed patterns H returns patterns to the beginning J oO 0 D GD Ti mM Laser Remote Test mode tst When the laser is in test mode this will only display a test image This is for service purposes only Blackout Auto show with all colours Auto show single colour 1 Auto show single colour 2 danilo Auto show single colour 3 Sound activated mode all colours Sound activated single colour 1 Sound activated single colour 2 Sound activated single colour 3 DMX mode Pattern select see chart Colour 1 PRIORE colour Channel 4 colour speed Channel 5 zooming 000 127 100 5 size 128 169 170 209 210 255 Channel 6 Y axis
7. unit the first time to avoid eye injury and to avoid breaking the law Keep this manual in a safe place for future reference Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are used incorrectly Pay close attention to each safety REMARK and WARNING statement in this manual a a A a H ee pe _ p Caution class 3b laser radiation When open avoid exposure to beam Laser radiation avoid exposure To beam class 3b laser product The label indicates the laser beam output aperture For many years there have been serious safety issues with projecting laser beams directly into the audience audience scanning This is where a laser beam or image is projected into the crowd where people can reach and touch the image and also look directly into the laser image One of the most dangerous situations when using a laser is hot spotting or use of single laser beams A single point laser beam can be highly dangerous as this can damage eyesight or cause blindness Hot spotting is where a laser image is projected for example a circle tunnel effect with high intensity lines superimposed on it The laser image should be the same intensity the whole way round the image Here at Kam we put you and your customers safety at the top of our agenda After months of development we have installed the XY laser with unique safety circuitry which allows us to introduce an indu
8. 1 single colour 1sound activated Sou2 single colour 1sound activated Sou3 single colour 1sound activated Pressing enter will select the desired mode DMX 512 1 i 2 o o o FUNG UP DOWN ENTER Adjusting the sound sensitivity Press the menu button until the S menu is displayed Use the up and down buttons to adjust the sensitivity 0 no sound sensitivity 9 maximum sensitivity Press the enter button to confirm your selection FUNC UP DOWN ENTER Connecting laser with DMX Master slave mode use without an external DMX controller Choose 1 unit to be the master unit using the menu button select the desired mode eg Auto or sound activated Connect a 3 pin XLR cable from the DMX output of the master unit to the DMX input of the slave unit continue this to connect all units in the chain using the menu button Select all other units to slave mode SLA press enter to confirm Now all lasers will copy the master unit exactly Note you Kam XY laser has 6 different slave modes SLA SLA5 choosing a different slave mode will add a 2 second delay to the slave units giving a far more versatile laser show Example 1 set the first unit to as master and to the mode required auto sound 2 set 29 SLAVE unit to SLA 1 3 setthe 34 SLAVE unit to SLA 2 This will give slave 2 a 2 second delay before it mimics the movement from the master unit and then SLA 3 will react 2 seconds after the SLA 2 unit giving a staggered lighting di
9. ead to all sorts of adverse consequences It is strongly recommend that you adhere to all Laser audience scan safety advice What is MPE Maximum Permisible Exposure This is maximum amount of laser light that the eye can sustain before damage could start occurring What effects are more suited to audience scanning Effects that include stationary or slow moving beams should be avoided at all times If you can see the beam moving through the path it is taking it is almost certainly too dangerous to project into the audience You should also avoid projecting effects that contain hot spots or dwell points in them Dwell is where extra points are put into certain parts of the effect to help define a sharp corner etc The energy present on these types of effect is not evenly dispersed and the hot spots can be hazardous Smooth flowing effects such as circular tunnels are safer because they maintain a constant speed Additionally if you keep the whole effect panning over the audience it helps to reduce the amount of time the laser beam is in any one person s eyes The XY Laser is designed not to create such hot spot beams that can cause any issue and the integral laser safety cut out circuit will switch the laser off if any of the scanning motors fail or stop working correctly Does scanning an effect at a faster speed make things safer Generally yes because the beam scans past the eye quicker therefore reducing the dose of laser energy into the
10. n the literature accompanying the appliance Select the installation location of your unit carefully Avoid placing it in direct sunlight or locations subject to vibration and excessive dust Do not use the unit where there are extremes in temperature below 41 F 5 C or exceeding 95 F 35 C Unpacking and safety Please unpack your new product carefully Your new product should reach you in perfect condition Please check that no damage has occurred during transit If any damage is found do not operate your unit Please contact the retailer you purchased it from immediately If there is any damage to the mains cable do not use the device Always disconnect the unit from the mains supply when carrying out any cleaning of the unit Manufacturer declarations A A wis E CE In compliance with the following requirements RoHS Directive 2002 95 EU and WEEE Directive 2002 96 EU If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal CE declaration of conformity R amp TTE Directive 1999 5 EU EMC Directive 2004 108 EU Low Voltage Directive 2006 95 EU The declarations are available on application from certification lambaplc com Before putting the devices into operation please observe the respective country specific regulations This manual contains important laser system safety and operation information Read and understand all instructions prior to powering on the laser
11. splay effect Connecting a DMX controller Each XY laser uses 10 DMX channels each DMX channel controls a function on the unit When connecting a DMX controller connect a 3pin XLR lead from the DMX output of your controller to the DMX input of the laser unit To control the laser with a DMX controller the unit will need to have a DMX address assigned to it Press the menu button until the DMX address value is displayed 001 512 Press the up down buttons until 001 is displayed Press the enter button to confirm your selection Note if the DMX address display is flashing this means that a DMX signal is NOT being received by the unit If the display is not flashing a DMX signal is present If more than one XY laser is to be controlled at the same time there are 2 ways to do this 1 ifall XY lasers are to be controlled the same set all units with the same DMX address example 001 2 if individual control of each XY laser is required then each unit will need its own DMX address example set unit 1 to 001 set unit 2 to 011 set unit 3 to 21 and so on adding 10 DMX channels to each unit 3 make sure that all units are at least 10 channels apart and that no channels cross over DMX 512 1 2 3 e e o o FUNC UP DOWN ENTER REN remote control mode Press the menu button until rEN is displayed Press enter to confirm selection The unit is now in remote control function and will operate from the controls on the supplied infrared remote control Using the
12. stry first A laser that can scan the audience providing certain guidelines are followed Our safety circuitry actually monitors the lasers functions by constantly checking the status of the lasers motors diodes and programming It performs this check approximately every 0 3 of a second If any issues are found with any of the components of the laser the unit will automatically shut itself down This will prevent any possible chance of single laser beam pointing in case of failure of the scanner motors Please Note When using any laser it is always best to act on the safe side Never take risks Never modify any laser unit Beware of unwanted reflections The XY laser has a scanning projected scanning angle of 120 degrees by 90 degrees This means that you can audience scan providing you adhere to some simple Laser Safety Rules What does the term audience scanning mean It is when a laser lighting effect is directed into the audience normally to create tunnels or sheets of light that look like 3D objects that the crowd can touch or look towards What are the legal rules of audience scanning In the UK and Europe there is no law that specifically states that it is illegal to audience scan But if a Laser Lighting effect can scan a laser effects into the audience you need to be certain that the MPE is not being exceeded If the MPE is exceeded there is a risk of members of the public sustaining eye injuries caused by the laser which could l
Download Pdf Manuals
Related Search
Related Contents
Utiliser des outils informatiques pour enseigner les mathématiques 軽便シリーズ 軽便壁打型 取扱説明書 rxycq8-20a7y1b_im_4pde327528-1_de MID User Manual Installation- and user manual LCS-KD04 Powermate PMC605000 Portable Generator User Manual ESTACIÓN METEOROLÓGICA Correction for Incorrect Description Notice RL78/G1A Descriptions in QMS® TOPIRAMATE - Fisher Scientific 6700032M User`s Manual Copyright © All rights reserved.