Home
PowerBridge TSPBIW-6
Contents
1. Install this product to meet National Electrical Code and or State Local Building Code as to requirements for installing electrical building wire and outlets as a single EXTENSION CIRCUIT without modification or alteration to the building electrical circuit wiring system THIS PRODUCT MUST BE INSTALLED TO A UL CLASSIFIED SINGLE GANG ELECTRICAL JUNCTION BOX TO MEET CODE COMPLIANCY AND TO ASSURE SAFETY gt The supplied non metallic junction boxes may not meet some local code requirements as metal junction boxes may be required for certain installations where it may require Metal Clad or Armored Clad building wire Please read and understand all instructions Follow WARNING and CAUTION labels on the product Use 12 2 or 14 2 Copper Utility CU wire only with this product This product is rated to use with an existing A C outlet 125v grounded circuit only For shock protection do not install this product to a non grounded outlet system Do not install this product near water example near a sink tub shower swimming pool or laundry area Manufacturer is not liable for damages due to improper installation methods not followed herein or as required by national electrical or local building code gt Installation Code Compliancy is the responsibility of user and or installer and not of the Manufacturer or it s agents If you are not skilled with running wires through wall it is strongly recommended that a qualified installation professional should ins
2. ation contained herein covers all details conditions or variations Nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Manufacturer makes no representation of specific warranty beyond the Limited Warranty expressed or implied regarding the information contained herein 2007 11 Ver 4 811
3. g OPODO CECENIA IE HD Products Inc Model TSPBIW TSPBIW 6 In Wall Bridge Extension F m PowerWire connects PowerOUT to PowerlN aOur together not to circuit Safe and Easy to Install ET Code Compliant when installed with i supplied ROMEX or optional MC type In Wall PowerWire PP P YP FowerlN Install behind AV equipment up to 75 from TV plug into surge protector FTI ETL LISTED W CONFORMS TO seus UL STD 514C 3183743 CERTIFIED TO CAN CSA STD C22 2 NO 42 1 or existing outlet Supplied 6 PowerConnect Cord TOOLS REQUIRED 4 Stud Finder Drywall Saw Phillips Flat Blade Wire Stripper Circuit Tester Optional Optional IMPORTANT PRODUCT INFORMATION 100 ALLRA Check with your local building jurisdiction as to permit license or code requirements for installing wire or outlets within a wall Some municipalities require an electrical inspection for any modification of electrical work HD Products recommends all modifications or alterations of existing or new electrical work to be inspected by a licensed electrical inspector THIS PRODUCT IS NOT TO BE INSTALLED DIRECT WIRED CONNECTED OR BRANCHED TO THE BUILDING ELECTRICAL CIRCUIT WIRING SYSTEM INSTALL THIS PRODUCT ONLY AS AN ELECTRICAL EXTENSION PLUG IN DEVICE TO AN EXISTING A C GROUNDED OUTLET TO ENERGIZE A C POWER USING A UL LISTED PLUG IN CORD SET WHEN INSTALLED WITH SPECIFIED CODE COMPLIANT BUILDING ELECTRICAL WIRE gt
4. k B Hook the wire end on the right clockwise side of the screw as shown w DOme Tighten the screws to each wire Check for proper wiring connections as labeled B S CXI wrong way POWER INLET Male Plug DO NOT BEND OR J THE END OF THE WIRES C Insert each of the three wires straight into the WIRE INSERT HOLES located on end of the INLET Each hole aligns with a colored screw around the sides Tighten the screws to each wire Check for proper wiring connections as labeled Push excess electrical wire back through rear opening of the WHITE box Secure both wall plates with color matched screws POWER INLET Plug female end of the POWER CORD onto the male plug of the POWER INLET Plug male plug of the POWER CORD into the existing A C outlet or power surge protector THE SYSTEM IS NOW POWERED NOTE If the supplied POWER CORD is not long enough DO NOT EXTEND THE SUPPLIED CORD with another extension cord Must use 3 prong grounded UL LISTED extension cord DO NOT EXCEED 15 FEET IN LENGTH POWER OUTLET OPTIONAL CHECK FOR PROPER WIRING CONNECTIONS WITH AN OUTLET TESTER The HDTV is now ready to plug in enjoy your wall mounted system W ETL LISTED CONFORMS TO UL STD 514C LPOwWwerBridge CERTIFIED TO CAN CSA STD C22 2 NO 42 1 Model TSPBIW The manufacturer intend to make this manual accurate and complete However no claim that the inform
5. ount Measure height and width of TV to keep the wall plate hidden behind the TV Wall plates can be installed up to 75 feet apart with additional in wall power wire Source Equipment Existing A C Outlet location POWER INLET Wall Plate Male Plug Determine location on the wall near the source equipment or within 60 inches of an existing A C outlet The POWER OUTLET and POWER INLET plates can be installed either vertically or horizontall Determine location on wall ceiling between framing studs with a stud finder Trace a cut line with the supplied cardboard template Level for proper alignment Cut around outside of line using a drywall saw or utility knife CAUTION DO NOT CUT AREA BETWEEN LARGE AND SMALL OPENING Route In Wall PowerWire within wall ceiling between the two larger cutouts Route Audio Video Cables within wall ceiling between the two smaller cutouts Using a screwdriver bend one tab OUT on the backside of the WHITE box Insert PowerWire Allow 4 inches to stick out from the edge of the box strip off 3 inches of the outer sheath of the power wire a Insert the WHITE box into the wall opening Screw in the 2 silver screws to open the wall wings to secure the boxes to the wallboard Use a level for proper alignment POWER OUTLET Female Receptacle A Using the tip of needle nose pliers or the bend hole on a wire stripper bend the wire end into a J shaped hoo
6. tall this product This product does not have built in electronic circuitry for surge protection or A C filtering It is recommended that this product be connected to a quality surge protector power conditioner for equipment protection Limited 2 year Warranty from Manufactures Defects HD Products Inc the Manufacturer it s agents suppliers and affiliates shall not be liable for damages not limited to misuse acts of nature verbal and written expression and improper installation Improper installation is determined such to include not limited to non code compliant installation product modifications alterations adjustments and connections using non code compliant methods and or materials Your TSPBIW has a limited two year product warranty against manufacturer s defects If you have any questions or experience any problems with your product please contact PowerBridge Customer Service Maximum claim liability not to exceed the product purchase price or Manufacturers Suggested Retail Price HD Products Inc PowerBridge 3869 Norwood Drive Littleton CO 80125 USA Customer Service 303 683 2434 x4101 info PowerBridgeSolution com www PowerBridge1 com STEP 1 TV PROJECTOR location POWER OUTLET Wall Plate Female Receptacle Determine where the TV wall mount will be installed on which side above or below the mount will be best suited for the location of the TV power connection and not to interfere with the TV installation on the m
Download Pdf Manuals
Related Search
Related Contents
ED1900 - シチズン・システムズ 5800 Refrigerated Sampler Service Manual Copyright © All rights reserved.
Failed to retrieve file