Home

American Weigh Scales SG-300

image

Contents

1. Norcross GA 30092 Made In China to our exact specifications and quality control
2. ALUS American Weigh Scales SG 300 User Manual SG 300 300g x 0 1g Copyright 2012 American Weigh Scales Inc All rights reserved Rev 2 0 SG 300 Manual Thank you for purchasing the American Weigh SG 300 spoon scale Please read all operating instructions carefully before use Scales are precision measuring devices and should always be handled with proper care To ensure years of reliable service keep these simple tips in mind When weighing try to keep your the spoon as level and steady as possible Do not exceed the scale s maximum capacity This scale has integrated overload protection but any overload protection has its limits Avoid exposure to extreme heat or cold Scales perform best at normal room temperature If temperatures have changed dramatically recalibration may be necessary Allow your scale to warm up for 30 60 seconds before performing calibration if available Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avoid using your scale in close proximity to strong radio wave emitting devices such as cordless phones Gently apply all items to be weighed Do not drop items onto the weighing spoon Avoid dropping your scale The warranty does not cover damage due to rough treatment or overload Check the batteries first if you are having any trouble with yo
3. le OFF press and hold the ON TARE key V Changing the Unit of Measure 1 Press the MODE key to change the scales displayed unit of measure 2 If the scale is turned off then back on it will default to the last unit used G 300 g gram oz ounce gt fl oz fluid ounce gt ml milliliter VI Using the Tare Feature Use the Tare feature to re zero the scale if necessary 1 Press the ON TARE key briefly The display will then reset to zero Vil Calibration Initial calibration is performed at the factory Calibration should only be performed by experienced users and only if the scales readings are off on a known weight such as a calibration weight Please note that accuracy will also depend highly on the angle that you hold the scale It should always remain level 1 Place the required calibration weight on the scale and note the displayed value 2 If the displayed value is not within acceptable tolerance see chart on next page adjustment is required Model Acceptable Calibration Recommended Tolerance Weight Accuracy Class SG 300 0 3g 200g OIML M2 Vill Adjustment 1 Press and hold the MODE button to enter calibration mode 2 The display will flash CAL Make sure the spoon is empty and press MODE again 3 The display will flash 200 0g Place a 200g calibration weight in the weighing spoon and keep the scale level and stable 4 The display will flash PASS then re
4. turn to normal weighing Calibration is complete SG 300 Manual IX Troubleshooting Problem Scale will not turn on Solution Check the batteries and battery contacts Problem Displayed weight fluctuates randomly Solution Make sure to hold the scale as still and level as possible when weighing Avoid strong air drafts and vibration sources Problem Displayed weight is inaccurate Solution Perform a calibration adjustment If you are still having trouble contact our warranty department X Error Codes 1 OUTZ Zero point has drifted out of the acceptable range Try to perform a calibration adjustment If the problem persists the load cell may be permanently damaged due to overloading 2 O Ld Overload The maximum capacity has been exceeded Remove the extra weight to avoid permanently damaging the load cell 3 Lo Batteries are low Replace the batteries XI Care and Maintenance 1 The detachable spoons are dishwasher safe 2 To clean the body of the scale use a slightly damp cloth Do not use harsh solvents or abrasives XII Specifications Capacity 0 5g 2 x 1 5V AAA Alkaline Display Dimensions 0 5 x 1 3 in Spoon Sizes 1 5 Tbsp and 3 0 Tbsp Warranty 10 Year Limited Warranty XIII Capacity Readability Charts 300g x 0 1g 10 580z x 0 010z 10 15fl oz x 0 01 fl oz 300ml x 0 1ml SG 300 Manual American Weigh Scales Inc
5. ur scale This simple step can remedy most scale issues Calibration should be checked and adjusted occasionally as part of routine scale maintenance I Part List 1 Scale 2 1 5 Tbsp Weighing Spoon 3 3 0 Tbsp Weighing Spoon 4 AAA Batteries x2 Il Key Description Ll MODE ONTARE 1 Mode Key Changes the displayed unit of measure 2 On Tare Key Turns the scale on Re zeros the scale if pressed briefly Hold to turn off the scale 3 Hold Key Press to hold the weight on the display Ill Battery Installation Proper Battery Installation Low batteries can cause inaccuracies in digital scales If you are experiencing issues with your scale first try new batteries Most times this will solve the problem SG 300 Manual 1 Before using the scale for the first time check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping storage 2 If you are replacing the batteries make sure the positive and negative contacts are properly aligned IV Operation 1 Press the ON TARE key to turn the scale on 2 Once the start up process completes and the scale goes to zero you are ready to weigh 3 Place the quantity to be weighed onto the weighing spoon and hold it level and steady 4 Wait a couple seconds for the display to stabilize before taking a weight reading 5 To turn the sca

Download Pdf Manuals

image

Related Search

Related Contents

輸出産業復活の方途  Samsung 32" professionaalne monitor koos täpse värvide taasesitusega Kasutusjuhend  i.Tech Arrow Lite User Guide i.Tech Arrow Lite  取付説明書 Gフレーム  GUIDE EMPLOI PGP  EUROLITE TC-150 User Manual  Instrucciones - Klein Tools Mexico  Nesco FG-180 mincer  Configuration Note - NFS Professional Services  USER MANUAL  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.