1.        Port 2 Module bay 4       Slot 2  Port 3  for 4 port cards    Module bay 3       Port 4  for 4 port cards    Module bay 4                         The following figure shows the location of the switch bays in the Flex System Enterprise Chassis         O module I O module  O module  O module  bay 1 bay 3 bay 2 bay 4          Figure 8  Location of the switch bays in the Flex System Enterprise Chassis    Flex System x240 Compute Node  E5 2600 v2  27       The following figure shows how two port adapters are connected to switches installed in the chassis           Each line between an I O adapter and a switch is four links          Figure 9  Logical layout of the interconnects between I O adapters and I O modules    Flex System PCle Expansion Node    The x240 supports the attachment of the Flex System PCle Expansion Node  The Flex System PCle  Expansion Node provides the ability to attach additional PCI Express cards such as High IOPS SSD  adatpers  fabric mezzanine cards  and next generation graphics processing units  GPU  to supported  Flex System compute nodes  This capability is ideal for many applications that require high performance  I O  special telecommunications network interfaces  or hardware acceleration using a PCI Express card   The PCle Expansion Node supports up to four PCle 2 0 adapters and two additional Flex System  expansion adapters     Flex System x240 Compute Node  E5 2600 v2  28    The PCle Expansion Node is attached to the x240 as shown in the follo
2.   1x E5 2680 v2 10C 2 8GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    25MB 1866MHz 115W 1866 MHz hot swap Embedded  2 max  8737 84x   1x E5 2690 v2 10C 3 0GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    25MB 1866MHz 130W 1866 MHz hot swap Embedded   2 max  8737 8Dx   2x E5 2690 v2 10C 3 0GHz 16x 16 GB LSI SAS2004   2x 2 5 inch Open     10 GbE 1 used    25MB 1866MHz 130W 1866 MHz hot swap Embedded  2 max  8737 94x   1x E5 2697 v2 12C 2 7GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    30MB 1866MHz 130W 1866 MHz hot swap Embedded   2 max  Models with Flex System CN4022 2 port 10Gb Converged Adapter  8737 1Mx   1x E5 2609 v2 4C 2 5GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    10MB 1333MHz 80W  1333 MHz  hot swap Adapter 2 max  8737 2Mx_   1x E5 2620 v2 6C 2 1GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    15MB 1600MHz 80W 1600 MHz hot swap Adapter 2 max  8737 BMx_   1x E5 2630 v2 6C 2 6GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    15MB 1600MHz 80W 1600 MHz hot swap Adapter 2 max            Processor detail  Processor quantity  model  cores  core speed  L3 cache  memory speed  power TDP rating     The 2 5 inch drive bays can be replaced and expanded with 1 8  solid state drive bays and a ServeRAID M5115    RAID controller to support up to eight 1 8 inch SSDs       Models have the following Ethernet controllers standard   e The x4x models include an Embedded 10Gb Virtual Fabric Ethernet controller  connect
3.   http   ibm com support entry portal     IBM System Storage   Interoperation Center  http   www ibm com systems support storage ssic    Flex System x240 Compute Node  E5 2600 v2     40    Notices    Lenovo may not offer the products  services  or features discussed in this document in all countries  Consult your  local Lenovo representative for information on the products and services currently available in your area  Any  reference to a Lenovo product  program  or service is not intended to state or imply that only that Lenovo product   program  or service may be used  Any functionally equivalent product  program  or service that does not infringe  any Lenovo intellectual property right may be used instead  However  it is the user s responsibility to evaluate and  verify the operation of any other product  program  or service  Lenovo may have patents or pending patent  applications covering subject matter described in this document  The furnishing of this document does not give you  any license to these patents  You can send license inquiries  in writing  to     Lenovo  United States   Inc    1009 Think Place   Building One  Morrisville  NC 27560   U S A    Attention  Lenovo Director of Licensing    LENOVO PROVIDES THIS PUBLICATION    AS IS    WITHOUT WARRANTY OF ANY KIND  EITHER EXPRESS OR  IMPLIED  INCLUDING  BUT NOT LIMITED TO  THE IMPLIED WARRANTIES OF NON INFRINGEMENT   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  Some jurisdictions do not allow disclaimer of  
4.  1       Model 8Dx includes 1x Flex System x240 USB Enablement Kit  1x USB Memory Key for VMware ESXi 5 1  and 1x   Blank USB Memory Key for VMware ESXi Downloads     Flex System x240 Compute Node  E5 2600 v2  9    TopSeller models  The following table lists the available TopSeller models     Table 3  TopSeller models                                              Model Intel Xeon Processor Memory   Disk Disk bayst Disks   10 GbE I O   2 maximum   adapter slots   TopSeller models   North America   8737 E1x   2x E5 2620 v2 6C 2 1GHz 2x 16GB  LSI 2 5    hot swap   Open  2x10Gb  1 2  15MB 1600MHz 80W 1600 MHz   SAS3004    0 2    FCoE    8737 E2x_   2x E5 2640 v2 8C 2 0GHz 4x 16GB  LSI 2 5    hot swap   Open  2x10Gb   1 2  20MB 1600MHz 95W 1600 MHz   SAS3004    0 2    FCoEt   8737 E3x   2x E5 2660 v2 10C 2 2GHz  4x16GB  LSI 2 5    hot swap   Open  2x10Gb  1 2  25MB 1866MHz 95W 1600 MHz   SAS3004    0 2    FCoE    8737 E4x   2x E5 2680 v2 10C 2 8GHz   8x16GB  LSI 2 5    hot swap   Open  2x10Gb  1 2  25MB 1866MHz 115W 1600 MHz   SAS3004   0 2    FCoEt                                          Processor detail  Processor quantity  model  cores  core speed  L3 cache  memory speed  power TDP rating      The 2 5 inch drive bays can be replaced and expanded with 1 8  solid state drive bays and a ServeRAID M5115  RAID controller to support up to eight 1 8 inch SSDs      These models have an onboard 10 GbE controller with two 10 GbE ports plus Virtual Fabric Advanced Software  Upgrade  LOM  
5.  CPU 2    The ServeRAID M5115 controller has the following specifications     Eight internal 6 Gbps SAS SATA ports  PCI Express 3 0 x8 host interface  6 Gbps throughput per port    800 MHz dual core IBM PowerPC   processor with LSI SAS2208 6 Gbps RAID on Chip  ROC   controller    Support for RAID levels 0  1  10  5  50 standard  support for RAID 6 and 60 with optional upgrade  using 90Y4411    Onboard 1 GB data cache  DDR3 running at 1333 MHz  with optional flash backup  MegaRAID  CacheVault technology  as part of the Enablement Kit 90Y4342     Support for SAS and SATA HDDs and SSDs    Support for intermixing SAS and SATA HDDs and SSDs  mixing different types of drives in the same  array  drive group  not recommended    Support for self encrypting drives  SEDs  with MegaRAID SafeStore    Optional support for SSD performance acceleration with MegaRAID FastPath and SSD caching with  MegaRAID CacheCade Pro 2 0  904447     Support for up to 64 virtual drives  up to 128 drive groups  up to 16 virtual drives per one drive group   and up to 32 physical drives per one drive group    Support for logical unit number  LUN  sizes up to 64 TB  Configurable stripe size up to 1 MB   Compliant with Disk Data Format  DDF  configuration on disk  COD   S M A R T  support    MegaRAID Storage Manager management software    Optional add ons to the ServeRAID M5115 controller are RAID 6 support  SSD performance accelerator   and SSD caching enabler  The feature upgrades are as listed in the followin
6.  Compute Node  E5 2600 v2  11    Processor options    The x240 supports the processor options listed in the following table  The server supports one or two  processors  The table also shows which server models have each processor standard  if any     Table 5  Processor options                                                                                              Part Feature code  Intel Xeon processor description Models  number where used  00Y2850   A4P9   A4PW Intel Xeon E5 2603 v2 4C 1 8GHz 10MB 1333MHz 80W     00Y2851   A4PA  A4PX Intel Xeon E5 2609 v2 4C 2 5GHz 10MB 1333MHz 80W 14x  1Mx  00AE510   A4PQ   A4QB Intel Xeon E5 2618L v2 6C 2 0GHz 15MB 1333MHz 50W  EMB       00Y2852   A4PB   A4PY Intel Xeon E5 2620 v2 6C 2 1GHz 15MB 1600MHz 80W 24x  2Mx  22x  00AE513   A4PT   A4QE Intel Xeon E5 2628L v2 8C 2 2GHz 20MB 1600MHz 70W  EMB       00Y2853   A4PC   A4PZ Intel Xeon E5 2630 v2 6C 2 6GHz 15MB 1600MHz 80W B4x  BMx  00Y2864   A4PN   A4Q9 Intel Xeon E5 2630L v2 6C 2 4GHz 15MB 1600MHz 60W     00Y2861   A4PK   A4Q6 Intel Xeon E5 2637 v2 4C 3 5GHz 15MB 1866MHZ 130W     00Y2854   A4PD   A4Q0 Intel Xeon E5 2640 v2 8C 2 0GHz 20MB 1600MHz 95W 34x  3Mx  00Y2862   A4PL   A4Q7 Intel Xeon E5 2643 v2 6C 3 5GHz 25MB 1866MHz 130W     00AE511   A4PR   A4QC Intel Xeon E5 2648L v2 10C 2 0GHz 25MB 1866MHz 70W  EMB       00Y2855   A4PP   A4Q1 Intel Xeon E5 2650 v2 8C 2 6GHz 20MB 1866MHz 95W 44x  4Mx  42x  00Y2865   A4PE   A4QA Intel Xeon E5 2650L v2 10C 1 7GHz 25MB 1600MHz 70W C4x  CMx  
7.  FC5172 2 port 16Gb FC Adapter 2 2 2   69Y1938   A1BM Flex System FC3172 2 port 8Gb FC Adapter 2 2 2   95Y2375   A2N5 Flex System FC3052 2 port 8Gb FC Adapter 2 2 2         For x4x models  where the Embedded 10Gb Virtual Fabric Adapter standard   and for xMx models  where a  CN4022 2 port 10Gb Converged Adapter is standard   only one extra adapter can be installed in the compute node     For adapter to switch compatibility  see the Flex System Interoperability Guide   http   www redbooks ibm com fsig    Flex System x240 Compute Node  E5 2600 v2     31                      PCle SSD adapters    The compute node supports the High IOPS SSD adapters listed in the following table  These adapters are  installed in an attached PCle Expansion Node     Table 20  SSD adapters                                                                                                          Part number Feature Description Maximum  code supported  46C9078 A3J3 365GB High IOPS MLC Mono Adapter  low profile adapter  4  46C9081 A3J4 785GB High IOPS MLC Mono Adapter  low profile adapter  4  81Y4519  5985 640GB High IOPS MLC Duo Adapter  full height adapter  2  81Y4527  A1NB 1 28TB High IOPS MLC Duo Adapter  full height adapter  2  90Y4377 A3DY 1 2TB High IOPS MLC Mono Adapter  low profile adapter  2  90Y4397 A3DZ 2 4TB High IOPS MLC Duo Adapter  full height adapter  2  00AE983 ARYK 1250GB Enterprise Value io3 Flash Adapter for System x 4  00AE986 ARYL 1600GB Enterprise Value io3 FlashAdapter for System 
8.  L3 cache    Chipset Intel C600 series    Memory Up to 24 DIMM sockets  12 DIMMs per processor  using Low Profile  LP  DDR3 DIMMs   RDIMMs  UDIMMs  and LRDIMMs supported  1 5V and low voltage 1 35V DIMMs supported   Support for up to 1600 MHz memory speed depending on the processor  Four memory  channels per processor  3 DIMMs per channel     Memory With LRDIMMs  Up to 768 GB with 24x 32 GB LRDIMMs and two processors    maximums With RDIMMs  Up to 384 GB with 24x 16 GB RDIMMs and two processors    With UDIMMs  Up to 64 GB with 16x 4 GB UDIMMs and two processors    Memory Error correction code  ECC   Chipkill  for x4 based memory DIMMs   memory mirroring  and   protection memory rank sparing    Disk drive bays   Two 2 5  hot swap SAS SATA drive bays supporting SAS  SATA  and SSD drives  Optional  support for up to eight 1 8    SSDs  Up to 12 additional 2 5 inch drive bays with the optional  Storage Expansion Node    Maximum With two 2 5    hot swap drives  Up to 2 TB with 1 TB 2 5  NL SAS HDDs  or up to 2 4 TB with 1 2    TB 2 5  SAS HDDs  or up to 2 TB with 1 TB 2 5  SATA HDDs  or up to 3 2 TB with 1 6 TB 2 5   SATA SSDs  An intermix of SAS and SATA HDDs and SSDs is supported  Alternatively  with  1 8    SSDs and ServeRAID M5115 RAID adapter  up to 6 4 TB with eight 800 GB 1 8    SSDs   Additional storage available with an attached Flex System Storage Expansion Node                       RAID support RAID 0 and 1 with integrated LSI SAS2004 controller  Optional ServeRAID M511
9.  can connect an external USB  optical drive  See http   support lenovo com en documents pd011281 for information about available  external optical drives from Lenovo     Note  The USB port on the compute nodes supply up to 0 5 A at 5 V  For devices that require more  power  an additional power source will be required     Embedded 10Gb Virtual Fabric Adapter    Some models of the x240    those with a model of the form 8737 x4x    include an Embedded 10Gb  Virtual Fabric Adapter  VFA  also known as LAN on Motherboard or LOM  built into the system board   Table 2 lists the models of the x240 include the Embedded 10Gb Virtual Fabric Adapter  Each x240  model that includes the embedded 10Gb VFA also has the Compute Node Fabric Connector installed in  I O connector 1  and physically screwed onto the system board  to provide connectivity to the Enterprise  Chassis midplane  Figure 3 shows the location of the Fabric Connector     The Fabric Connector enables port 1 on the embedded 10Gb VFA to be routed to I O module bay 1 and  port 2 to be routed to I O module bay 2  The Fabric Connector can be unscrewed and removed  if  required  to allow the installation of an I O adapter on I O connector 1     The Embedded 10Gb VFA is based on the Emulex BladeEngine 3R  BE3R   which is a single chip   dual port 10 Gigabit Ethernet  10GbE  Ethernet Controller     These are some of the features of the Embedded 10Gb VFA     PCI Express Gen2 x8 host bus interface   Supports connection to 10 Gb and 1 G
10.  required  and therefore this kit does not have a supercap  This v2 kit provides  support for the latest high performance SSDs     Note  The original ServeRAID M5100 Series Flex System Flash Kit for x240  90Y4341 is not  supported     ServeRAID M5100 Series SSD Expansion Kit for Flex System x240  90Y4391  enables support  for up to four internal 1 8 inch SSDs  This kit includes two air baffles  left and right  which can attach  two 1 8 inch SSD attachment locations and Flex cables for attachment to up to four 1 8 inch SSDs     Note  The SSD Expansion Kit cannot be installed if the USB Enablement Kit  49Y8119  is already  installed as these kits occupy the same location in the server     The following table shows the kits required for each combination of drives  For example  if you plan to  install eight 1 8 inch SSDs  then you will need the M5115 controller  the Flash kit  and the SSD Expansion    kit     Table 10  ServeRAID M5115 hardware kit usage matrix                                                 Desired drive support Components required  Maximum Maximum ServeRAID SSD  number of number of M5115 Enablement Kit Flash Kit v2 Expansion Kit  2 5  drives 1 8  SSDs 90Y4390 90Y4342 47C8808 90Y4391  2 0   gt    Required Required  0 4  front    gt    Required Required  2 4  internal    gt    Required Required Required  0 8  both    gt    Required Required Required                                                                         Flex System x240 Compute Node  E5 2600 v2  1
11.  the DIMMs do not need being identical   In rank sparing  mode  one rank of a DIMM in each populated channel is reserved as spare memory  The size of a rank  varies depending on the DIMMs installed     Flex System x240 Compute Node  E5 2600 v2  15    Internal storage    The x240 server has two 2 5 inch hot swap drive bays accessible from the front of the blade server   Figure 2   These bays connect to the integrated LSI SAS2004 6 Gbps SAS SATA RAID on Chip  ROC     controller   The integrated LSI SAS2004 ROC has the following features     Four port LSI SAS2004 controller with 6 Gbps throughput per port  PCle x4 Gen 2 host interface   Two SAS ports routed internally to the two hot swap drive bays  Supports RAID 0  RAID 1 and RAID 1E    The x240 also supports up to eight 1 8 inch drives with the addition of the ServeRAID M5115 controller  and additional SSD tray hardware  These are described in the next section     Supported drives are listed in the Internal drive options section     ServeRAID M5115 SAS SATA controller    The x240 supports up to eight 1 8 inch solid state drives combined with a ServeRAID M5115 SAS SATA  controller  90Y4390   The M5115 attaches to the I O adapter 1 connector and can be attached even if the  Compute Node Fabric Connector is installed  used to route the Embedded 10Gb Virtual Fabric Adapter to  bays 1 and 2  as discussed in  I O expansion options    The ServeRAID M5115 cannot be installed if an  adapter is installed in I O adapter slot 1     The Se
12. 00 v2  13    The following rules apply when selecting the memory configuration     e Mixing 1 5 V and 1 35 V DIMMs in the same server is supported  In such a case all DIMMs operate at  1 5V     e Mixing of different types of DIMMs  UDIMM   RDIMM and LRDIMM  in the same server is not  supported     e The maximum number of ranks supported per channel is eight     e The maximum quantity of DIMMs that can be installed in the server depends on the number of CPUs   DIMM rank  and operating voltage  as shown in the  Max  qty supported  row in the following table   The shaded cells indicate that the DIMM type supports the maximum number of DIMMs  24 for the  x240     e  All DIMMs in all CPU memory channels operate at the same speed  which is determined as the  lowest value of     e Memory speed supported by specific CPU    e Lowest maximum operating speed for the selected memory configuration that depends on rated  speed  as shown under the  Max  operating speed  section in the following table  The shaded  cells indicate that the speed indicated is the maximum that the DIMM allows     The following two tables  Part 1 and Part 2  show the maximum memory speeds that are achievable  based on the installed DIMMs and the number of DIMMs per channel  The tables also show maximum  memory capacity at any speed supported by the DIMM and maximum memory capacity at rated DIMM  speed  In the tables  cells highlighted with a gray background indicate when the specific combination of  DIMM voltage 
13. 00AE512   A4PS   A4QD Intel Xeon E5 2658 v2 10C 2 4GHz 25MB 1866MHz 95W  EMB       00Y2856   A4PF   A4Q2 Intel Xeon E5 2660 v2 10C 2 2GHz 25MB 1866MHz 95W 54x  5Mx  00Y2863   A4PM   A4Q8 Intel Xeon E5 2667 v2 8C 3 3GHz 25MB 1866MHz 130W       00Y2857   A4PG  A4Q3 Intel Xeon E5 2670 v2 10C 2 5GHz 25MB 1866MHz 115W 64x  6Mx  62x  00Y2858   A4PH   A4Q4 Intel Xeon E5 2680 v2 10C 2 8GHz 25MB 1866MHz 115W 74x  7Mx  72x  00Y2859   A4PJ   A4Q5 Intel Xeon E5 2690 v2 10C 3 0GHz 25MB 1866MHz 130W 84x  8Dx  8Mx  00Y2848   A4P7  A4PU Intel Xeon E5 2695 v2 12C 2 4GHz 30MB 1866MHz 115W     00Y2849   A4P8  A4PV Intel Xeon E5 2697 v2 12C 2 7GHz 30MB 1866MHz 130W 94x  9Mx                                 The first feature code is for processor 1 and second feature code is for processor 2      Use of the Intel Xeon E5 2667 v2 processor in the Flex System x240 Compute Node is limited to 30   C up to 3000  feet  914 m   Above 3000 feet  a de rating of 1   C for every 600 feet  182 m  should be applied  Use of the  ServeRAID M5115 SAS SATA RAID Controller with the E5 2667 v2 processor is not supported  Flex System  configurations using the E5 2667 v2 processor will operate at acoustic levels significantly greater than typical Flex  System levels  and the following noise hazard warning may apply    Notice  Government regulations  such as those prescribed by OSHA or European Community Directives  may govern noise level  exposure in the workplace and may apply to you and your server installation  The 
14. 35 V 1 5V 1 5V   Max quantityt 24 24 24 24 24   Largest DIMM 8 GB 8 GB 16 GB 16 GB 16 GB   Max memory 192 GB 192 GB 384 GB 384 GB 384 GB   capacity   Max memory at None 128 GB None 256 GB 256 GB   rated speed   Maximum operating speed  MHz    One DIMM per 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1866 MHz   channel   Two DIMMs per 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1866 MHz   channel   Three DIMMs per 1066 MHz 1066 MHz 1066 MHz 1333 MHz   1333 MHz     channel 1066 MHz  1066 MHz                                                                 The maximum quantity that is supported is shown for two processors installed  When one processor is installed   the maximum quantity that is supported is half of that shown     00D5044  8 GB  operates at 1066 MHz at three DIMMs per channel  46W0672  16 GB  operates at 1333 MHz at    three DIMMs per channel     00D5028  4 GB  and 00D5040  8 GB  operate at 1066 MHz at three DIMMs per channel  00D5048  16 GB     operates at 1333 MHz at three DIMMs per channel  The following memory protection technologies are supported     ECC   Chipkill  for x4 based memory DIMMs    look for  x4  in the DIMM description   Memory mirroring   Memory sparing    If memory mirroring is used  then DIMMs must be installed in pairs  minimum of one pair per CPU   and  both DIMMs in a pair must be identical in type and size     If memory rank sparing is used  then a minimum of one quad rank DIMM or two single rank or dual rank  DIMMs must be installed per populated channel 
15. 5 RAID  controller with RAID 0  1  10  5  and 50 support and 1 GB cache  Supports up to eight 1 8    SSDs  with expansion kits  Optional flash backup for cache  RAID 6 60  SSD performance enabler    Optical and No internal bays  use an external USB drive  See   tape bays http   support lenovo com en documents pd011281 for options    Network x4x models  Two 10 Gb Ethernet ports with Embedded 10Gb Virtual Fabric Ethernet   interfaces LAN on motherboard  LOM  controller  Emulex BE3R based  FCoE iSCSI support with Features    on Demand  FoD  upgrade    xMx models  CN4022 2 port 10Gb Converged Adapter standard  Broadcom BCM57840 based   FCoE iSCSI support standard    x2x models  None standard  optional 1Gb or 10GbE adapters           Flex System x240 Compute Node  E5 2600 v2                 Table 1  Standard specifications  part 2                                                        Components Specification   PCI Expansion   Two I O connectors for adapters  PCI Express 3 0 x16 interface  Includes an Expansion   slots Connector  PCle 3 0 x16  to connect an expansion node  such as the PCle Expansion Node   PCle Expansion Node supports two full height PCle adapters  two low profile PCle adapters   and two Flex System I O adapters    Ports USB ports  One external  Two internal for embedded hypervisor with optional USB Enablement  Kit  Console breakout cable port providing local KVM and serial ports  cable standard with  chassis  additional cables optional     Systems UEFI  Integrate
16. 7    The following figure shows how the ServeRAID M5115 and the Enablement Kit are installed in the server  to support two 2 5 inch drives with MegaRAID CacheVault flash cache protection  row 1 of the preceding  table            ServeRAID M5115 controller  90Y4390  with  ServeRAID M5100 Series Enablement Kit  90Y4342                 ServeRAID  M5115  controller    MegaRAID CacheVault Replacement 2 drive  flash cache protection backplane          Figure 4  The ServeRAID M5115 and the Enablement Kit installed    The following figure shows how the ServeRAID M5115 and Flash and SSD Expansion Kits are installed in  the server to support eight 1 8 inch solid state drives  row 4 of the preceding table         ServeRAID M5115 controller  90Y4390  with  ServeRAID M5100 Series Flash Kit v2  47C8808  and  ServeRAID M5100 Series SSD Expansion Kit  90Y4391     ServeRAID  M5115  controller    Eight drives supported     Four internal drives    Four front accessible drives    Flash Kit Replacement SSD Expansion Kit  Four SSDs on  4 drive SSD backplane special air baffles above DIMMs  and drive bays  no CacheVaultflash protection           Figure 5  ServeRAID M5115 with Flash and SSD Expansion Kits installed    Flex System x240 Compute Node  E5 2600 v2  18    The eight SSDs are installed in the following locations     Four in the front of the system in place of the two 2 5 inch drive bays    Two in a tray above one of the memory banks for CPU 1  Two in a tray above one of the memory banks for
17. Adapter 4 2 2       90Y3558   A1RO Flex System CN4054 Virtual Fabric Adapter  SW Upgrade  License  2 2   Feature on Demand to provide FCoE and iSCSI support to the  CN4054R     one license required per adapter        90Y3466   A1QY Flex System EN4132 2 port 10 Gb Ethernet Adapter 2 2 2       1 Gb Ethernet                         49Y7900   A10Y Flex System EN2024 4 port 1 Gb Ethernet Adapter 4 2 2  InfiniBand  90Y3454   A1QZ Flex System IB6132 2 port FDR InfiniBand Adapter 2 2 2                     For x4x models  where the Embedded 10Gb Virtual Fabric Adapter standard   and for xMx models  where a  CN4022 2 port 10Gb Converged Adapter is standard   only one extra adapter can be installed in the compute node     For adapter to switch compatibility  see the Flex System Interoperability Guide   http   www redbooks ibm com fsig    Flex System x240 Compute Node  E5 2600 v2  30    Storage host bus adapters    The following table lists storage HBAs supported by the x240 server  both internally in the compute node  and in the PCle Expansion Node     Table 19  Storage adapters                                                                                           Part Feature Description Number Maximum  number code of ports supported   x240    PEN    Fibre Channel   88Y6370   A1BP Flex System FC5022 2 port 16Gb FC Adapter 2 2 2   95Y2386   A45R Flex System FC5052 2 port 16Gb FC Adapter 2 2 2   95Y2391   A45S Flex System FC5054 4 port 16Gb FC Adapter 4 2 2   69Y1942  A1BQ Flex System
18. D 2  41Y8336 A4FN  3700 400GB SATA 2 5  MLC HS Enterprise SSD 2  41Y8331 A4FL  3700 200GB SATA 2 5  MLC HS Enterprise SSD 2  49Y6195 A4GH 1 6TB SAS 2 5  MLC HS Enterprise SSD 2  49Y6139 A3F0 800GB SAS 2 5  MLC HS Enterprise SSD 2  49Y6134 A3EY 400GB SAS 2 5  MLC HS Enterprise SSD 2  00W1125 A3HR 100GB SATA 2 5  MLC HS Enterprise SSD 2  Solid state drives   Enterprise Value  00AJ000 A4KM  3500 120GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ005 A4KN S3500 240GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ010 A4KP  3500 480GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ015 A4KQ S3500 800GB SATA 2 5  MLC HS Enterprise Value SSD 2  OOFN268 A5U4  3500 1 6TB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ355 A56Z 120GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ360 A570 240GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ365 A571 480GB SATA 2 5  MLC HS Enterprise Value SSD 2  00AJ370 A572 800GB SATA 2 5  MLC HS Enterprise Value SSD 2  Flex System x240 Compute Node  E5 2600 v2  22    The 1 8 inch solid state drives supported are listed in the following table  The use of 1 8 inch drives    requires the ServeRAID M5115 SAS SATA controller as described in the next section     Table 13  Supported 1 8 inch solid state drives                                                                                                    Part number Feature Description Maximum  code supported  Enterprise SSDs  49Y6119 A3AN 200GB SATA 1 8  MLC Enterprise SSD 8  49Y6124 A3AP 400GB SATA 1 8  MLC Enterp
19. EN61000 3 3    CISPR 22  Class A   TUV GS  EN60950 1 IEC 60950 1  EK1 ITB2000     Flex System x240 Compute Node  E5 2600 v2     39    Related publications and links    For more information  see the following resources     Lenovo Press Product Guides for System x servers and options  http   www redbooks ibm com portals systemx  Open amp page pgbycat    US Announcement Letter  http   ibm com common ssi cgi bin ssialias  infotype dd amp subtype ca amp  amp htmlfid 897 ENUS 1 13 198    Flex System x240 Compute Node product page  http   ibm com systems flex compute nodes x86 bto     Flex System Information Center  http   publib  boulder ibm com infocenter flexsys information index jsp    Flex System x240 Compute Node Installation and Service Guide  http   publib boulder ibm com infocenter flexsys information topic com ibm acc 8737 doc printable_doc html    ServerProven for Flex System  http   ibm com systems info x86servers serverproven compat us flexsystems html    ServerProven hardware compatibility page for the x240  http   ibm com systems info x86servers serverproven compat us flex 8737_7863 html    ServerProven compatibility page for operating system support  http   ibm com systems info x86servers serverproven compat us nos flexmatrix shtml    Flex System Interoperability Guide  http   www redbooks ibm com fsig    Configuration and Option Guide  http   www ibm com systems xbc cog     xREF   System x Reference Sheets  http   www redbooks ibm com xref    System x Support Portal
20. SFF G2HS HDD 2   42D0637 5599 300GB 10K 6Gbps SAS 2 5  SFF Slim HS HDD 2   15K SAS hard disk drives   00AJ300 A4VB 600GB 15K 6Gbps SAS 2 5  G2HS HDD 2   81Y9670 A283 300GB 15K 6Gbps SAS 2 5  SFF HS HDD 2   42D0677 5536 146GB 15K 6Gbps SAS 2 5  SFF Slim HS HDD 2   90Y8926 A2XB 146GB 15K 6Gbps SAS 2 5  SFF G2HS HDD 2   10K and 15K Self encyrpting drives  SED    00AD085 A48T 1 2TB 10K 6Gbps SAS 2 5  G2HS SED 2   81Y9662 A3EG 900GB 10K 6Gbps SAS 2 5  SFF G2HS SED 2   90Y8913 A2XF 300GB 10K 6Gbps SAS 2 5  SFF G2HS SED 2   90Y8944 A2ZK 146GB 15K 6Gbps SAS 2 5  SFF G2HS SED 2   NL SAS   81Y9690 A1P3 1TB 7 2K 6Gbps NL SAS 2 5  SFF HS HDD 2   90Y8953 A2XE 500GB 7 2K 6Gbps NL SAS 2 5  SFF G2HS HDD 2   42D0707 5409 500GB 7200 6Gbps NL SAS 2 5  SFF Slim HS HDD 2   NL SATA   81Y9722 A1NX 250GB 7 2K 6Gbps NL SATA 2 5  SFF HS HDD 2   81Y9726 A1NZ 500GB 7 2K 6Gbps NL SATA 2 5  SFF HS HDD 2   81Y9730 A1AV 1TB 7 2K 6Gbps NL SATA 2 5  SFF HS HDD 2   10K and 15K SAS SSD Hybrid drive   00AD102 A4G7 600GB 10K 6Gbps SAS 2 5  G2HS Hybrid 2   Flex System x240 Compute Node  E5 2600 v2  21                                  Table 12  2 5 inch drive options for internal disk storage  Part 2                                                                                                                                                                             Partnumber   Feature   Description Maximum  code supported  Solid state drives   Enterprise  41Y8341 A4FQ  3700 800GB SATA 2 5  MLC HS Enterprise SS
21. Web sites is at your own risk  Any performance data contained herein was  determined in a controlled environment  Therefore  the result obtained in other operating environments may vary  significantly  Some measurements may have been made on development level systems and there is no guarantee  that these measurements will be the same on generally available systems  Furthermore  some measurements may  have been estimated through extrapolation  Actual results may vary  Users of this document should verify the  applicable data for their specific environment        Copyright Lenovo 2013 2015  All rights reserved     Flex System x240 Compute Node  E5 2600 v2  41    This document was created or updated on January 30  2015     Send us your comments in one of the following ways    e Use the online Contact us review form found at   ibm com redbooks   e Send your comments in an e mail to   redbooks us ibm com    This document is available online at http   www ibm com redbooks abstracts tips1090 html      Trademarks    Lenovo  For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in  the United States  other countries  or both  These and other Lenovo trademarked terms are marked on  their first occurrence in this information with the appropriate symbol     or       indicating US registered or  common law trademarks owned by Lenovo at the time this information was published  Such trademarks  may also be registered or common law trademarks in other countri
22. actual sound pressure levels in your installation  depend upon a variety of factors  including the number of racks in the installation  the size  materials  and configuration of the  room  the noise levels from other equipment  the room ambient temperature  and employees    location in relation to the equipment   Further  compliance with such government regulations also depends upon a variety of additional factors  including the duration of  employees    exposure and whether employees wear hearing protection  Lenovo recommends that you consult with qualified  experts in this field to determine whether you are in compliance with the applicable regulations      Flex System x240 Compute Node  E5 2600 v2     Memory options    DDR3 memory is compatibility tested and tuned for optimal performance and throughput  Memory  specifications are integrated into the light path diagnostics for immediate system performance feedback  and optimum system uptime  From a service and support standpoint  memory automatically assumes the  system warranty  and Lenovo provides service and support worldwide     The following table lists memory options available for the x240 compute node with E5 2600 v2  processors  DIMMs can be installed one at a time  but for performance reasons  install them in sets of  four  one for each of the four memory channels      Table 6  Memory options for the x240 with E5 2600 v2 processors       Part number   Feature   Description Models  code where used          Registere
23. and number of DIMMs per channel still allows the DIMMs to operate at rated speed     Table 7  Maximum memory speeds  Part 1   UDIMMs and LRDIMMs                                                                       Specification UDIMMs LRDIMMs  Rank Dual rank Quad rank  Part numbers 00D5012  4 GB  46W0761  32 GB   00D5016  8 GB   Rated speed 1600 MHz 1866 MHz  Rated voltage 1 35 V 1 5V  Operating voltage 1 35 V 1 5V 1 5V  Maximum quantity  16 16 24  Largest DIMM 8 GB 8 GB 32 GB  Max memory capacity 128 GB 128 GB 768 GB  Max memory at rated None 128 GB 512 GB  speed  Maximum operating speed  MHz   One DIMM per channel 1333 MHz 1600 MHz 1866 MHz  Two DIMMs per channel 1333 MHz 1600 MHz 1866 MHz  Three DIMMs per channel NSt NSt 1333 MHz            The maximum quantity supported is shown for two processors installed  When one processor is installed  the  maximum quantity supported is half of that shown     NS   Not supported  UDIMMs only support up to 2 DIMMs per channel     Flex System x240 Compute Node  E5 2600 v2  14          Table 8  Maximum memory speeds  Part 2   Single rank and dual rank RDIMMs                                                                                                     Specification RDIMMs   Rank Single rank Dual rank   Part numbers 00D5024  4 GB  00D5044  8 GB  00D5028  4 GB   00D5036  8 GB  46W0672  16 GB  00D5040  8 GB    00D5048  16 GB    Rated speed 1600 MHz 1600 MHz 1866 MHz   Rated voltage 1 35 V 1 35 V 1 5V   Operating voltage 1 35 V 1 5V 1 
24. are listed in the boot menu  which allows you to boot from either device or to set one as a backup in case  the first one gets corrupted     Note  The x240 USB Enablement Kit and USB memory keys are not supported if the SSD Expansion Kit   90Y4391  is already installed  because these kits occupy the same location in the server     Table 22  Virtualization options                                              Part number Feature Description Maximum  code supported  49Y8119 A3A3 x240 USB Enablement Kit 1  41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 2  41Y8300 A2VC USB Memory Key for VMware ESXi 5 0 1  41Y8307 A383 USB Memory Key for VMware ESXi 5 0 Update 1  41Y8311 A2R3 USB Memory Key for VMware ESXi 5 1 1  41Y8382 A4WZ USB Memory Key for VMware ESXi 5 1 Update 1 1  41Y8385 A584 USB Memory Key for VMware ESXi 5 5 1       Flex System x240 Compute Node  E5 2600 v2  34    Light path diagnostics    For quick problem determination when located physically at the server  the x240 offers a three step  guided path     1  The Fault LED on the front panel  2  The light path diagnostics panel  shown in the following figure   3  LEDs next to key components on the system board    The x240 light path diagnostics panel is visible when you remove the server from the chassis  The panel  is located on the top right hand side of the compute node  as shown in the following figure        Figure 11  Location of x240 light path diagnostics panel  To illuminate the light path diagnostic
25. ature enables the SSDs to be  configured as a dedicated cache to help maximize the I O performance for transaction intensive  applications  such as databases and web serving  The feature tracks data storage access patterns  and identifies the most frequently accessed data  The hot data is then automatically stored on the  SSDs that are assigned as a dedicated cache pool on the ServeRAID controller  Part number  90Y4447 is a Feature on Demand license  This feature requires at least one SSD drive be installed     Note  Not all SSDs support SSD Caching Enabler  CacheCade  feature  See  http   ibm com support entry portal docdisplay Indocid MIGR 5094754 for details     Flex System x240 Compute Node  E5 2600 v2     20    Internal drive options    The 2 5  drive bays support SAS or SATA hard disk drives  HDDs  or SATA solid state drives  SSDs    The following table lists the supported 2 5  drive options     Table 12  2 5 inch drive options for internal disk storage  Part 1                                                                                                                                                                                Partnumber   Feature   Description Maximum  code supported   10K SAS hard disk drives   00AD075 A48S 1 2TB 10K 6Gbps SAS 2 5  G2HS HDD 2   81Y9650 A282 900GB 10K 6Gbps SAS 2 5  SFF HS HDD 2   90Y8872 A2XD 600GB 10K 6Gbps SAS 2 5  SFF G2HS HDD 2   49Y2003 5433 600GB 10K 6Gbps SAS 2 5  SFF Slim HS HDD 2   90Y8877 A2XC 300GB 10K 6Gbps SAS 2 5  
26. b Flex System Ethernet switches  Supports multiple virtual NIC  vNIC  functions   TCP IP Offload Engine  TOE enabled    SR IOV capable   RDMA over TCP IP capable   iSCSI and FCoE upgrade offering via FoD    The following table lists the ordering information for the IBM Virtual Fabric Advanced Software Upgrade   LOM   which enables the iSCSI and FCoE support on the Embedded 10Gb Virtual Fabric Adapter     Table 15  Feature on Demand upgrade for FCoE and iSCSI support                                  Part number Feature Description Maximum  code supported  90Y9310 A2TD IBM Virtual Fabric Advanced Software Upgrade  LOM  1       Flex System x240 Compute Node  E5 2600 v2  25    CN4022 2 port 10Gb Converged Adapter    Some models of the x240    those with a model of the form 8737 xMx    include the Flex System CN4022  2 port 10Gb Converged Adapter installed in slot 1  Table 2 lists the models with this adapter standard   These models require that a compatible Ethernet switch be installed in I O module bays 1 and 2 of the  chassis     The features of the CN4022 2 port 10Gb Converged Adapter include the following features     One Broadcom BCM57840 ASIC   Connection to either 1 Gb or 10 Gb data center infrastructure  1 Gb and 10 Gb auto negotiation   PCI Express 3 0 x8 host interface   Full line rate performance   Supports 10 Gb Ethernet  FCoE  and iSCSI out of the box  no Features on Demand upgrade  required    e Supports vNIC   Switch Independent Mode    For details about this adapt
27. d DIMMs  RDIMMs    1866 MHz    00D5048 A3QL   16GB  1x16GB  2Rx4  1 5V  PC3 14900 CL13 ECC DDR3 1866MHz   8Dx  LP RDIMM                      00D5040 A3QJ__  8GB  1x8GB  2Rx8  1 5V  PC3 14900 CL13 ECC DDR3 1866MHz LP   All other 1866 MHz  RDIMM models             00D5028 A3QF   4GB  1x4GB  2Rx8  1 5V  PC3 14900 CL13 ECC DDR3 1866MHz LP  RDIMM          Registered DIMMs  RDIMMs    1600 MHz    46W0672 A3QM_  16GB  1x16GB  2Rx4  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz  LP RDIMM          00D5036   A3QH   8GB  1x8GB  1Rx4  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz   All 1600 MHz  LP RDIMM models       00D5044 A3QK  8GB  1x8GB  2Rx8  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz z  LP RDIMM       00D5024 A3QE  4GB  1x4GB  1Rx4  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz    LP RDIMM       Unbuffered DIMMs  UDIMMs     00D5016 A3QC   8GB  1x8GB  2Rx8  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz J  LP UDIMM          00D5012 A3QB  4GB  1x4GB  2Rx8  1 35V  PC3L 12800 CL11 ECC DDR3 1600MHz    LP UDIMM       Load reduced DIMMs  LRDIMMs     46W0761 A47K       32GB  1x32GB  4Rx4  1 5V  PC3 14900 CL13 ECC DDR3 1866MHz  LP LRDIMM                                                                      The x240 supports Low Profile  LP  DDR3 memory RDIMMs  UDIMMs  and LRDIMMs  The server  supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are  installed  Each processor has four memory channels  and there are three DIMMs per channel     Flex System x240 Compute Node  E5 26
28. d Management Module 2  IMM2  with Renesas SH7757 controller  Predictive   management Failure Analysis  light path diagnostics panel  automatic server restart  remote presence   Support for IBM Flex System Manager     IBM Systems Director and Active Energy Manager   and Lenovo ServerGuide    Security Power on password  administrator s password  Trusted Platform Module 1 2    features   Video Matrox G200eR2 video core with 16 MB video memory integrated into the IMM2  Maximum  resolution is 1600x1200 at 75 Hz with 16 M colors    Limited Three year customer replaceable unit and onsite limited warranty with 9x5 NBD    warranty   Operating Microsoft Windows Server 2008 R2  Red Hat Enterprise Linux 5 and 6  SUSE Linux Enterprise   systems Server 10 and 11  VMware ESX 4  See  Supported operating systems  for details    supported   Service and Optional service upgrades are available through ServicePacs    4 hour or 2 hour response time    support 8 hour fix time  1 year or 2 year warranty extension  remote technical support for hardware and  selected and original equipment manufacturer  OEM  software    Dimensions Width  215 mm  8 5      height 51 mm  2 0      depth 493 mm  19 4        Weight Maximum configuration  6 98 kg  15 4 Ib         The x240 servers are shipped with the following items     e Statement of Limited Warranty  e Important Notices  e Documentation CD that contains the  nstallation and User s Guide    Flex System x240 Compute Node  E5 2600 v2                    Standa
29. d into the Intel Xeon  processor E5 family  This helps to dramatically reduce I O latency and increase overall system  performance     Support for high bandwidth I O adapters  up to two in each x240 Compute Node  Support for 10 Gb  Ethernet  16 Gb Fibre Channel  and FDR InfiniBand     Supports the PCle Expansion Node for support for up to six additional I O adapters     Availability and serviceability    The x240 provides many features to simplify serviceability and increase system uptime     Chipkill  memory mirroring and memory rank sparing for redundancy in the event of a non correctable  memory failure     Tool less cover removal provides easy access to upgrades and serviceable parts  such as CPU   memory  and adapter cards     Hot swap drives supporting integrated RAID 1 redundancy for data protection and greater system  uptime     A light path diagnostics panel and individual light path LEDs to quickly lead the technician to failed  or  failing  components  This simplifies servicing  speeds up problem resolution  and helps improve  system availability     Predictive Failure Analysis  PFA   which detects when system components  such as processors   memory  and hard disk drives  operate outside of standard thresholds and generates pro active alerts  in advance of possible failure  therefore increasing uptime     Solid state drives  SSDs   which offer significantly better reliability than traditional mechanical HDDs  for greater uptime     Built in Integrated Management Mo
30. dule II  IMM2  continuously monitors system parameters  triggers  alerts  and performs recovering actions in case of failures to minimize downtime     Built in diagnostics using Dynamic Systems Analysis  DSA  Preboot speeds up troubleshooting  tasks to reduce service time     Three year customer replaceable unit and onsite limited warranty  next business day 9x5  Optional  service upgrades are available     Manageability and security    Powerful systems management features simplify local and remote management of the x240     Flex System x240 Compute Node  E5 2600 v2     The x240 includes an Integrated Management Module II  IMM2  to monitor server availability and  perform remote management     Integrated industry standard Unified Extensible Firmware Interface  UEFI  enables improved setup   configuration  and updates  and simplifies error handling     Integrated Trusted Platform Module  TPM  1 2 support enables advanced cryptographic functionality   such as digital signatures and remote attestation     Industry standard AES NI support for faster  stronger encryption     Integrates with the IBM   Flex System    Manager for proactive systems management  It offers  comprehensive systems management for the entire Flex System platform that help to increase  up time  reduce costs  and improve productivity through advanced server management capabilities     Fabric Manager simplifies deployment of infrastructure connections by managing network and  storage address assignments     Int
31. e  right  attached to a compute node  left   The ordering information for the Storage Expansion Node is shown in the following table     Table 14  Ordering part number and feature code             Part number Feature code  Description Maximum  supported  68Y8588 A3JF Flex System Storage Expansion Node 1                   The Storage Expansion Node has the following features    e Connects directly to supported compute nodes via a PCle 3 0 interface to the compute node s  expansion connector  See Figure 3    e Support for 12 hot swap 2 5 inch drive  accessible via a sliding tray   e Support for 6 Gbps SAS and SATA drives  both HDDs and SSDs   e Based on an LSI SAS2208 6 Gbps RAID on Chip  ROC  controller    e Supports RAID O  1  5  10  and 50 as standard  JBOD also supported  Optional RAID 6 and 60 with a  Features on Demand upgrade     e Optional 512 MB or 1 GB cache with cache to flash super capacitor offload    Note  The use of the Storage Expansion Node requires that the x240 Compute Node have both  processors installed     For more information  see the Product Guide on the Flex System Storage Expansion Node   http   www redbooks ibm com abstracts tips0914 html Open    Flex System x240 Compute Node  E5 2600 v2  24       Internal tape drives    The server does not support an internal tape drive  However  it can be attached to external tape drives  using Fibre Channel connectivity     Optical drives    The server does not support an internal optical drive option  however  you
32. el Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow  attacks when combined with a supporting operating system     Intel Trusted Execution Technology provides enhanced security through hardware based resistance  to malicious software attacks  allowing an application to run in its own isolated space protected from  all other software running on a system     Energy efficiency    The x240 offers the following energy efficiency features to save energy  reduce operational costs   increase energy availability  and contribute to the green environment     Component sharing design of the Flex System chassis provides ultimate power and cooling savings     The Intel Xeon processor E5 2600 v2 product family offers significantly better performance over the  E5 2600 family while fitting into the same thermal design power  TDP  limits     Intel Intelligent Power Capability powers individual processor elements on and off as needed  to  reduce power draw     Low voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally  constrained data centers and telecommunication environments     Low voltage 1 35 V DDR3 memory RDIMMs consume 15  less energy than 1 5 V DDR3 RDIMMs     Solid state drives  SSDs  consume as much as 80  less power than traditional spinning 2 5 inch  HDDs     The x240 uses hexagonal ventilation holes  a part of IBM Calibrated Vectored Cooling    technology   Hexagonal holes can be grouped more densely t
33. environments  Flex System is scalable and extendable with  multi generation upgrades to protect and maximize IT investments     Flex System x240 Compute Node  E5 2600 v2  1    Key features    The Flex System x240 Compute Node is a high availability  scalable compute node optimized to support  the next generation microprocessor technology and is ideally suited for medium and large businesses   This section describes the key features of the server     Scalability and performance    The x240 offers numerous features to boost performance  improve scalability  and reduce costs     Flex System x240 Compute Node  E5 2600 v2     Improves productivity by offering superior system performance with 12 core processors  up to 2 7  GHz core speeds   10 core processors  up to 3 0 GHz core speeds   8 core processors  up to 3 3  GHz core speeds   6 core and 4 core processors  up to 3 5 GHz core speeds   up to 30 MB of L3  cache  and up to two 8 GT s QPI interconnect links     Supports up to two processors  24 cores  and 48 threads to maximize the concurrent execution of  multithreaded applications     Supports up to 1866 MHz memory speeds   Up to 24 DIMM sockets for maximum scalability and performance   Supports up to 768 GB memory with 24x 32 GB LRDIMMs     Intelligent and adaptive system performance with Intel Turbo Boost Technology 2 0 allows CPU cores  to run at maximum speeds during peak workloads by temporarily going beyond processor TDP     Intel Hyper Threading Technology boosts perfor
34. er  see the Product Guide   http   www redbooks ibm com abstracts tips 1087 html Open    I O expansion options    The x240 has two I O expansion connectors for attaching I O adapter cards  There is a third expansion  connector designed to connect an expansion node such as the PCle Expansion Node  The I O expansion  connectors are a very high density 216 pin PCle connector  Installing I O adapter cards allows the server  to connect with switch modules in the Flex System Enterprise Chassis  Each slot has a PCI Express 3 0  x16 host interface and both slots support the same form factor adapters     The following figure shows the location of the I O expansion connectors                 Figure 7  Location of the I O adapter slots in the Flex System x240 Compute Node    All I O adapters are the same shape and can be used in any available slot   A compatible switch or  pass through module must be installed in the corresponding I O bays in the chassis  as indicated in the  following table  Installing two switches means that all ports of the adapter are enabled  which improves  performance and network availability     Flex System x240 Compute Node  E5 2600 v2  26    Table 16  Adapter to I O bay correspondence                I O adapter slot in the server Port on the adapter Corresponding I O module bay in the chassis  Port 1 Module bay 1  Port 2 Module bay 2   Slot 1       Port 3  for 4 port cards    Module bay 1       Port 4  for 4 port cards    Module bay 2       Port 1 Module bay 3
35. es  A current list of Lenovo trademarks  is available on the Web at http   www lenovo com legal copytrade  html     The following terms are trademarks of Lenovo in the United States  other countries  or both     Flex System     Lenovo    Lenovo logo     ServeRAID     ServerGuide     ServerProven    System x    vNIC       The following terms are trademarks of other companies     Intel  Intel Xeon  Intel logo  Intel Inside logo  and Intel Centrino logo are trademarks or registered  trademarks of Intel Corporation or its subsidiaries in the United States and other countries     Linux is a trademark of Linus Torvalds in the United States  other countries  or both     Microsoft  Windows  and the Windows logo are trademarks of Microsoft Corporation in the United States   other countries  or both     Other company  product  or service names may be trademarks or service marks of others     Flex System x240 Compute Node  E5 2600 v2  42    
36. express or implied warranties in certain transactions  therefore  this statement may not apply to you     This information could include technical inaccuracies or typographical errors  Changes are periodically made to the  information herein  these changes will be incorporated in new editions of the publication  Lenovo may make  improvements and or changes in the product s  and or the program s  described in this publication at any time  without notice     The products described in this document are not intended for use in implantation or other life support applications  where malfunction may result in injury or death to persons  The information contained in this document does not  affect or change Lenovo product specifications or warranties  Nothing in this document shall operate as an express  or implied license or indemnity under the intellectual property rights of Lenovo or third parties  All information  contained in this document was obtained in specific environments and is presented as an illustration  The result  obtained in other operating environments may vary  Lenovo may use or distribute any of the information you supply  in any way it believes appropriate without incurring any obligation to you     Any references in this publication to non Lenovo Web sites are provided for convenience only and do not in any  manner serve as an endorsement of those Web sites  The materials at those Web sites are not part of the materials  for this Lenovo product  and use of those 
37. g table  These are all FoD  license upgrades     Table 11  Supported upgrade features             Part number   Feature   Description Maximum  code supported   90Y4410 A2Y1 ServeRAID M5100 Series RAID 6 Upgrade for Flex System 1   90Y4412 A2Y2 ServeRAID M5100 Series Performance Upgrade for Flex System 1     MegaRAID FastPath           90Y4447 A36G ServeRAID M5100 Series SSD Caching Enabler for Flex System 1                 MegaRAID CacheCade Pro 2 0                 Flex System x240 Compute Node  E5 2600 v2  19       These features are described as follows     RAID 6 Upgrade  90Y44 10   Adds support for RAID 6 and RAID 60  This is a Feature on Demand license   Performance Upgrade  90Y4412     The Performance Upgrade for Flex System  implemented using the LSI MegaRAID FastPath  software  provides high performance I O acceleration for SSD based virtual drives by exploiting an  extremely low latency I O path to increase the maximum I O per second  IOPS  capability of the  controller  This feature boosts the performance of applications with a highly random data storage  access pattern  such as transactional databases  Part number 90Y4412 is a Feature on Demand  license     SSD Caching Enabler for traditional hard drives  90Y4447     The SSD Caching Enabler for Flex System  implemented using the LSI MegaRAID CacheCade Pro  2 0  is designed to accelerate the performance of hard disk drive  HDD  arrays with only an  incremental investment in solid state drive  SSD  technology  The fe
38. han round holes  providing more efficient airflow  through the system     Flex System x240 Compute Node  E5 2600 v2     Locations of key components and connectors    Figure 2 shows the front of the server        Two 2 5  hot swap  drive bays              Light path  diagnostics  panel    p LED  Console breakout aiii panel    USB port cable port          Figure 2  Front view of the Flex System x240 Compute Node    Figure 3 shows the locations of key components inside the server        Hot swap drive bay Processor 2 and 12 I O connector 1  backplane memory DIMMs    Fabric Connector       Light path Processor 1 and 12 I O connector 2 Expansion  diagnostics memory DIMMs Connector          Figure 3  Inside view of the Flex System x240 Compute Node    Flex System x240 Compute Node  E5 2600 v2     Standard specifications    The following table lists the standard specifications     Table 1  Standard specifications  part 1        Components    Specification       Models    8737 x2x  8737 x4x  and 8737 xMx  x config    8737 15X  e config         Form factor    Standard width compute node        Chassis support    Flex System Enterprise Chassis                             internal storage    Processor Up to two Intel Xeon processor E5 2600 v2 product family CPUs with 12 cores  up to 2 7 GHz   or ten cores  up to 3 0 GHz  or eight cores  up to 3 3 GHz  or six cores  up to 3 5 GHz  or four  cores  up to 3 5 GHz   Two QPI links up to 8 0 GT s each  Up to 1866 MHz memory speed  Up  to 30 MB
39. hange  5   C hr  41   F hr     Power off     e Temperature  5   45   C  41   113   F   e Relative humidity  8   85   e Maximum dew point  27   C  80 6   F     Storage  non operating      e Temperature  1   60   C  33 8   140   F   e   Altitude  3050 m  10 006 ft    e Relative humidity  5   80    e Maximum dew point  29   C  84 2  F     Shipment  non operating      Temperature   40   60   C   40   140   F   Altitude  10 700 m  35 105 ft   Relative humidity  5   100     e  e  e  e Maximum dew point  29   C  84 2   F     Flex System x240 Compute Node  E5 2600 v2     37    Warranty options    The Flex System x240 Compute Node has a three year on site warranty with 9x5 next business day  terms  Lenovo offers the warranty service upgrades through ServicePac  discussed in this section  The  ServicePac is a series of prepackaged warranty maintenance upgrades and post warranty maintenance  agreements with a well defined scope of services  including service hours  response time  term of service   and service agreement terms and conditions     ServicePac offerings are country specific  That is  each country might have its own service types  service  levels  response times  and terms and conditions  Not all covered types of ServicePac might be available  in a particular country  For more information about ServicePac offerings available in your country  see the  ServicePac Product Selector at https   www 304 ibm com sales gss download spst servicepac     The following table explains warra
40. heVault  unit  which enables MegaRAID CacheVault flash cache protection  This enablement kit replaces the  standard two bay backplane  which is attached via the planar to an onboard controller  with a new  backplane that attaches to an included flex cable to the M5115 controller  It also includes an air  baffle  which also serves as an attachment for the CacheVault unit     MegaRAID CacheVault flash cache protection uses NAND flash memory powered by a  supercapacitor to protect data stored in the controller cache  This module eliminates the need for a  lithium ion battery commonly used to protect DRAM cache memory on PCI RAID controllers  To avoid  the possibility of data loss or corruption during a power or server failure  CacheVault technology  transfers the contents of the DRAM cache to NAND flash using power from the supercapacitor  After  the power is restored to the RAID controller  the saved data is transferred from the NAND flash back  to the DRAM cache  which can then be flushed to disk     Tip  The Enablement Kit is only required if 2 5 inch drives are to be used  If you plan to install four or  eight 1 8 inch SSDs only  then this kit is not required     ServeRAID M5100 Series Flex System Flash Kit v2 for x240  47C8808  enables support for up to  four 1 8 inch SSDs  This kit replaces the standard two bay backplane with a four bay SSD backplane  that attaches to an included flex cable to the M5115 controller  Because only SSDs are supported  a  CacheVault unit is not
41. ions are routed using a   Fabric Connector  The Fabric Connector precludes the use of an I O adapter in I O connector 1   e The xMx models include an Flex System CN4022 2 port 10Gb Converged Adapter in slot 1        Model 8Dx includes 1x Flex System x240 USB Enablement Kit  1x USB Memory Key for VMware ESXi 5 1  and 1x  Blank USB Memory Key for VMware ESXi Downloads     Flex System x240 Compute Node  E5 2600 v2        Table 2  Standard models  Part 2                                                                             Model Intel Xeon Processor Memory Disk Disk bayst Disks   10 GbE   O slots   2 maximum   adapter  8737 3Mx_   1x E5 2640 v2 8C 2 0GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    20MB 1600MHz 95W 1600 MHz hot swap Adapter 2 max  8737 4Mx_   1x E5 2650 v2 8C 2 6GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    20MB 1866MHz 95W 1866 MHz hot swap Adapter 2 max  8737 CMx   1x E5 2650L v2 10C 1 7GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    25MB 1600MHz 70W 1600 MHz hot swap Adapter 2 max  8737 5Mx_   1x E5 2660 v2 10C 2 2GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    25MB 1866MHz 95W 1866 MHz hot swap Adapter 2 max  8737 6Mx_   1x E5 2670 v2 10C 2 5GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    25MB 1866MHz 115W 1866 MHz hot swap Adapter 2 max  8737 7Mx_   1x E5 2680 v2 10C 2 8GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    25MB 1866MHz 115W 1866 MHz hot swap Adapter 2 max  8737 8Mx_   1
42. ith a model number of  the form 8737 x4x or 8737 xDx  have a 10Gb Ethernet controller on the system board  and its ports are  routed to the midplane and switches installed in the chassis via a Compute Note Fabric Connector that  takes the place of an adapter in I O slot 1     Models without the Embedded 10Gb Virtual Fabric Adapter  those with a model number of the form  8737 x2x  do not include any other Ethernet connections to the Enterprise Chassis midplane as standard   Therefore  for those models  an I O adapter must be installed in either I O connector 1 or I O connector 2  to provide network connectivity between the server and the chassis midplane and ultimately to the  network switches     The following table lists the supported network adapters and upgrades  Adapters can be installed in either  slot  However  compatible switches must be installed in the corresponding bays of the chassis  All  adapters can also be installed in the PCle Expansion Node  The  Maximum supported  column indicates  the number of adapter than can be installed in the server and in the PCle Expansion Node  PEN      Table 18  Network adapters       Part Feature   Description Number   Maximum  number   code of ports   supported   x240    PEN        40 Gb Ethernet       90Y3482   ASHK Flex System EN6132 2 port 40Gb Ethernet Adapter 2 2  None       10 Gb Ethernet       88Y5920   A4K3 Flex System CN4022 2 port 10Gb Converged Adapter 2 2 2       00Y3306   A4K2 Flex System CN4054R 10Gb Virtual Fabric 
43. lenovo  i  THOSE fae    Flex System x240 Compute Node  E5 2600 v2     Lenovo Press Product Guide    The Flex System    x240 Compute Node is a high performance server that offers outstanding performance  for virtualization with new levels of CPU performance and memory capacity  and flexible configuration  options  Now available with Intel Xeon E5 2600 v2 processors  the x240 Compute Node is an efficient  server designed to run a broad range of workloads  armed with advanced management capabilities that  allow you to manage your physical and virtual IT resources from a single pane of glass  This Product  Guide describes the Flex System x240 Compute Node     Suggested uses  Database  virtualization  enterprise applications  collaboration email  streaming media   web  HPC  Microsoft RemoteFX  and cloud applications     Figure 1 shows the Flex System x240 Compute Node        Figure 1  The Flex System x240 Compute Node    Did you know     Flex System is a new category of computing that integrates multiple server architectures  networking   storage  and system management capability into a single system that is easy to deploy and manage  Flex  System has full built in virtualization support of servers  storage  and networking to speed provisioning  and increased resiliency  In addition  it supports open industry standards  such as operating systems   networking and storage fabrics  virtualization  and system management protocols  to easily fit within  existing and future data center 
44. m  A virtual presence capability comes  standard for remote server management     Remote server management is provided through industry standard interfaces     e   Intelligent Platform Management Interface  IPMI  Version 2 0  e Simple Network Management Protocol  SNMP  Version 3   e Common Information Model  CIM    e Web browser    The server also supports virtual media and remote control features  which provide the following functions     e Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per  pixel  regardless of the system state   e Remotely accessing the server using the keyboard and mouse from a remote client   e Mapping the CD or DVD drive  diskette drive  and USB flash drive on a remote client  and mapping  ISO and diskette image files as virtual drives that are available for use by the server   e Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive   e Capturing blue screen errors    Supported operating systems  The server supports the following operating systems     Microsoft Windows Server 2008 HPC Edition   Microsoft Windows Server 2008 R2   Microsoft Windows Server 2008  Datacenter x64 Edition  Microsoft Windows Server 2008  Enterprise x64 Edition  Microsoft Windows Server 2008  Standard x64 Edition  Microsoft Windows Server 2008  Web x64 Edition  Microsoft Windows Server 2012   Microsoft Windows Server 2012 R2   Red Hat Enterprise Linux 5 Server with Xen x64 Edition  Red Hat Ente
45. mance for multi threaded applications by enabling  simultaneous multi threading within each processor core  up to two threads per core     Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating  system vendors to better utilize the hardware for virtualization workloads     Intel Advanced Vector Extensions  AVX  significantly improve floating point performance for  compute intensive technical and scientific applications compared with Intel Xeon 5600 series  processors     The theoretical maximum memory bandwidth of the Intel Xeon processor E5 family is 51 6 GBps   which is 60  more than in the previous generation of Intel Xeon processors     The use of solid state drives  SSDs  instead of or along with traditional spinning drives  HDDs  can  significantly improve I O performance  An SSD can support up to 100 times more I O operations per  second  IOPS  than a typical HDD     Supports the Storage Expansion Node providing an additional 12 hot swap 2 5 inch drive bays for  local storage     Up to 32 virtual I O ports per compute node with integrated 10 Gb Ethernet ports  offering the choice  of Ethernet  iSCSI  or Fibre Channel over Ethernet  FCoE  connectivity     The x240 offers PCI Express 3 0 I O expansion capabilities that improve the theoretical maximum  bandwidth by 60   8 GT s per link   compared with the previous generation of PCI Express 2 0     With Intel Integrated I O Technology  the PCI Express 3 0 controller is integrate
46. nty service definitions in more detail     Table 24  Warranty service definitions          Term Description  On site A service technician will come to the server s location for equipment repair   repair  OR        24x7x2 hour    A service technician is scheduled to arrive at your customer   s location within two hours after  remote problem determination is completed  We provide 24 hour service  every day  including  Lenovo holidays        24x7x4 hour    A service technician is scheduled to arrive at your customer   s location within four hours after  remote problem determination is completed  We provide 24 hour service  every day  including  Lenovo holidays        9x5x4 hour    A service technician is scheduled to arrive at your customer   s location within four business hours  after remote problem determination is completed  We provide service from 8 00 a m  to 5 00 p m   in the customer s local time zone  Monday through Friday  excluding Lenovo holidays  If after 1 00  p m  it is determined that on site service is required  the customer can expect the service  technician to arrive the morning of the following business day  For noncritical service requests  a  service technician will arrive by the end of the following business day        9x5 next  business day             A service technician is scheduled to arrive at your customer   s location on the business day after we  receive your call  following remote problem determination  We provide service from 8 00 a m  to  5 00 
47. p m  in the customer s local time zone  Monday through Friday  excluding Lenovo holidays              In general  these are the types of ServicePacs     e Warranty and maintenance service upgrades    e One  two  three  four  or five years of 9x5 or 24x7 service coverage  e On site repair from the next business day to four or two hours  e One or two years of warranty extension    e Remote technical support services    One or three years with 24x7 coverage  severity 1  or 9 5 next business day for all severities  Installation and startup support for System x   servers   Remote technical support for System x servers   Software support   Support Line    e Microsoft or Linux software  e VMware  e IBM Systems Director    Flex System x240 Compute Node  E5 2600 v2  38    Regulatory compliance    The server conforms to the following standards     ASHRAE Class A3   FCC   Verified to comply with Part 15 of the FCC Rules Class A  Canada ICES 004  issue 3 Class A   UL IEC 60950 1   CSA C22 2 No  60950 1   NOM 019   Argentina IEC 60950 1   Japan VCCI  Class A   IEC 60950 1  CB Certificate and CB Test Report    China CCC  GB4943    GB9254  Class A    GB17625 1    Taiwan BSMI CNS13438  Class A  CNS14336   Australia New Zealand AS NZS CISPR 22  Class A   Korea KN22  Class A  KN24   Russia GOST ME01  IEC 60950 1  GOST R 51318 22  GOST R  51318 249  GOST R 51317 3 2  GOST R 51317 3 3   IEC 60950 1  CB Certificate and CB Test Report    CE Mark  EN55022 Class A  EN60950 1  EN55024  EN61000 3 2   
48. pter is installed in the PCle Expansion Node  it occupies both full height slots  The  low profile slots and Flex System I O expansion slots can still be used     t  If installed  only this adapter is supported in the system  No other PCle adapters may be installed        Orderable as separate MTM 4765 001 feature 4809  Available via AAS  e config  only     Power supplies    Server power is derived from the power supplies installed in the chassis  There are no server options  regarding power supplies     Flex System x240 Compute Node  E5 2600 v2     33                Integrated virtualization    The x240 supports the ESXi hypervisor on a USB memory key via the x240 USB Enablement Kit  This kit  offers two internal USB ports  The x240 USB Enablement Kit and the supported USB memory keys are  listed in the following table     There are two types of USB keys  preloaded keys or blank keys  Blank keys allow you to download a  Lenovo customized version of ESXi and load it onto the key  Preload keys are shipped with a specific  version of ESXi already loaded  The x240 supports one or two keys installed  but only certain  combinations     Supported combinations   e One preload key   e One blank key   e One preload key and one blank key  e Two blank keys   Unsupported combinations    e Two preload keys    Installing two preloaded keys will prevent ESXi from booting as described in  http   kb vmware com kb 1035107  Having two keys installed provides a backup boot device  both devices  
49. rd models    Table 2 lists the standard models     Table 2  Standard models  Part 1                                                                                                     Model Intel Xeon Processor Memory Disk Disk bayst Disks   10 GbE   O slots   2 maximum   adapter  Models with embedded 10 Gb Virtual Fabric Ethernet  8737 14x   1x E5 2609 v2 4C 2 5GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    10MB 1333MHz 80W  1333 MHz  hot swap Embedded   2 max  8737 24x   1x E5 2620 v2 6C 2 1GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    15MB 1600MHz 80W 1600 MHz hot swap Embedded   2 max  8737 B4x   1x E5 2630 v2 6C 2 6GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    15MB 1600MHz 80W 1600 MHz hot swap Embedded  2 max  8737 34x   1x E5 2640 v2 8C 2 0GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    20MB 1600MHz 95W 1600 MHz hot swap Embedded   2 max  8737 44x   1x E5 2650 v2 8C 2 6GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    20MB 1866MHz 95W 1866 MHz hot swap Embedded  2 max  8737 C4x_   1x E5 2650L v2 10C 1 7GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    25MB 1600MHz 70W 1600 MHz hot swap Embedded   2 max  8737 54x   1x E5 2660 v2 10C 2 2GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    25MB 1866MHz 95W 1866 MHz hot swap Embedded   2 max  8737 64x   1x E5 2670 v2 10C 2 5GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open 10 GbE 1 used    25MB 1866MHz 115W 1866 MHz hot swap Embedded  2 max  8737 74x 
50. rise SSD 8  00W1120 A3HQ 100GB SATA 1 8  MLC Enterprise SSD 8  41Y8366 A4FS  3700 200GB SATA 1 8  MLC Enterprise SSD 8  41Y8371 A4FT S3700 400GB SATA 1 8  MLC Enterprise SSD 8  Enterprise Value SSDs  00AJ040 A4KV  3500 80GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ045 A4KW  3500 240GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ050 A4KX  3500 400GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ455 A58U  3500 800GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ335 A56V 120GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ340 A56W 240GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ345 A56X 480GB SATA 1 8  MLC Enterprise Value SSD 8  00AJ350 A56Y 800GB SATA 1 8  MLC Enterprise Value SSD 8                                        Flex System x240 Compute Node  E5 2600 v2     23    Flex System Storage Expansion Node    The x240 supports the attachment of the Flex System Storage Expansion Node  The Flex System  Storage Expansion Node provides the ability to attach additional 12 hot swap 2 5 inch HDDs or SSDs  locally to the attached compute node  The Storage Expansion Node provides storage capacity for  Network Attach Storage  NAS  workloads  providing flexible storage to match capacity  performance and  reliability needs     Model 8737 HBx includes the Storage Expansion Node as standard as listed in Table 2  All other models  support the SEN as an option     The following figure shows the Flex System Storage Expansion Node attached to a compute node        Figure 6  Flex System Storage Expansion Nod
51. rprise Linux 5 Server x64 Edition   Red Hat Enterprise Linux 6 Server x64 Edition   Red Hat Enterprise Linux 7   SUSE Enterprise Linux Server  SLES  12   SUSE LINUX Enterprise Server 11 for AMD64 EM64T  SUSE LINUX Enterprise Server 11 with Xen for AMD64 EM64T  SUSE Linux Enterprise Server 12 with XEN   VMware vSphere 5 0  ESXi    VMware vSphere 5 1  ESXi    VMware vSphere 5 5  ESXi     Note  Support by some of these operating system versions will be after the date of initial availability   Check the ServerProven   website for the latest information about the specific versions and service levels  supported and any other prerequisites   http   www ibm com systems info x86servers serverproven compat us nos matrix shtml    Flex System x240 Compute Node  E5 2600 v2  36    Physical specifications  Dimensions and weight  approximate      Height  56 mm  2 2 in    Depth  492 mm  19 4 in    Width  217 mm  8 6 in   Maximum weight  7 1 kg  15 6 Ib     Shipping dimensions and weight  approximate      Height  197 mm  7 8 in   Depth  603 mm  23 7 in   Width  430 mm  16 9 in   Weight  8 kg  17 6 Ib     Supported environment   The Flex System x240 compute node complies with ASHRAE Class A3 specifications   This is the supported operating environment    Power on    Temperature  5   40   C  41   104   F    Humidity  non condensing   12   C dew point  10 4   F  and 8   85  relative humidity  Maximum dew point  24   C  75   F     Maximum altitude  3048 m  10 000 ft   Maximum rate of temperature c
52. rveRAID M5115 supports combinations of 2 5 inch drives and 1 8 inch solid state drives     Up to two 2 5 inch drives only   Up to four 1 8 inch drives only   Up to two 2 5 inch drives  plus up to four 1 8 inch solid state drives  Up to eight 1 8 inch solid state drives    The ServeRAID M5115 SAS SATA Controller  90Y4390  provides an advanced RAID controller  supporting RAID 0  1  10  5  50  and optional 6 and 60  It includes 1 GB of cache  which can be backed up  to Flash when attached to the supercapacitor included with the optional ServeRAID M5100 Series  Enablement Kit  90Y4342      At least one hardware kit is required with the ServeRAID M5115 controller  and there are three hardware  kits that are supported that enable specific drive support     Table 9  ServeRAID M5115 and hardware kits             Part number Feature   Description Maximum  code supported  90Y4390 A2XW   ServeRAID M5115 SAS SATA Controller for Flex System 1       90Y4342 A2XX ServeRAID M5100 Series Enablement Kit for Flex System x240 1       47C8808 A47D ServeRAID M5100 Series Flex System Flash Kit v2 for x240 1       90Y4391 A2XZ ServeRAID M5100 Series SSD Expansion Kit for Flex System x240 1                               Flex System x240 Compute Node  E5 2600 v2  16    The hardware kits have the following features     ServeRAID M5100 Series Enablement Kit for Flex System x240  90Y4342  enables support for up  to two 2 5    HDDs or SSDs in the hot swap bays in the front of the server  It includes a Cac
53. s LEDs  power off the compute node  slide it out of the chassis  and  press the power button  The power button doubles as the light path diagnostics remind button when the  server is removed from the chassis     The meanings of the LEDs in the light path diagnostics panel are listed in the following table     Table 23  Light path diagnostic panel LEDs  LED Meaning          LP The light path diagnostics panel is operational        S BRD A system board error is detected        MIS A mismatch has occurred between the processors  DIMMs  or HDDs within the configuration as  reported by POST        NMI A non maskable interrupt  NMI  has occurred        TEMP An over temperature condition occurs that was critical enough to shut down the server           MEM A memory fault has occurred  The corresponding DIMM error LEDs on the system board are also lit           ADJ A fault is detected in the adjacent expansion unit  if installed                              Flex System x240 Compute Node  E5 2600 v2  35    Remote management    The server contains an Integrated Management Module II  IMM2   which interfaces with the advanced  management module in the chassis  The combination of these provides advanced service processor  control  monitoring  and an alerting function  If an environmental condition exceeds a threshold or if a  system component fails  LEDs on the system board are lit to help you diagnose the problem  the error is  recorded in the event log  and you are alerted to the proble
54. to enable iSCSI and FCoE    Flex System x240 Compute Node  E5 2600 v2     Chassis support  The x240 is supported in the Flex System Enterprise Chassis     Up to 14 x240 Compute Nodes can be installed in the chassis  however  the actual number that can be  installed in a chassis depends on these factors     e The TDP power rating for the processors that are installed in the x240  e The number of power supplies installed in the chassis   e The capacity of the power supplies installed  2100 W or 2500 W    e The chassis power redundancy policy used  N 1 or N N     The following table provides guidelines about what number of x240 Compute Nodes can be installed  For  more guidance  use the Power Configurator  found at the following website   http   ibm com systems bladecenter resources powerconfig html    In the table   e Green   No restriction to the number of x240 Compute Nodes that are installable  e Yellow   Some bays must be left empty in the chassis    Table 4  Maximum number of x240 Compute Nodes installable based on power supplies installed and  power redundancy policy used       2100 W power supplies installed 2500 W power supplies installed       N 1  N 5   N 1  N 4   N 1  N 3   N N  N 3   N41  N 5   N 1  N 4   N 1  N 3   N N  N 3  x240 TDP   6 power 5 power 5 power 6 power 6 power 5 power 4 power 6 power  rating supplies supplies supplies supplies   supplies supplies supplies supplies                   60 W  70 W  80 W  95 W  115 W  130 W  135 W          Flex System x240
55. wing figure        PCle expansion  node          Figure 10  PCle Expansion Node  The ordering information for the PCle Expansion Node is shown in the following table     Table 17  Ordering part number and feature code                Part number Feature code Description Maximum  supported  81Y8983 A1BV Flex System PCle Expansion Node 1                            The PCle Expansion Node has the following features     e Support for up to four standard PCle 2 0 adapters     e Two PCle 2 0 x16 slots that support full length  full height adapters  e Two PCle 2 0 x8 slots that support half length  low profile adapters    e Support for PCle 3 0 adapters by operating them in PCle 2 0 mode    e Support for one full length  full height double wide adapter  consuming the space of the two  full length  full height adapter slots     e Support for PCle cards with higher power requirements    a single adapter card  up to 225W   or to  two adapters  up to 150W each     e Two Flex System I O expansion connectors for to further expand the I O capability of the attached  compute node     Note  The use of the PCle Expansion Node requires that the x240 Compute Node have both processors  installed     For more information  see the Product Guide on the Flex System PCle Expansion Node   http   www redbooks ibm com abstracts tips0906 html Open    Flex System x240 Compute Node  E5 2600 v2  29             Network adapters    As described in  Embedded 10Gb Virtual Fabric Adapter   certain models  those w
56. x 4  00AE989 ARYM 3200GB Enterprise Value io3 Flash Adapter for System x 4  00AE992 ARYN 6400GB Enterprise Value io3 Flash Adapter for System x 2  00AE995 ARYP 1000GB Enterprise io3 Flash Adapter for System x 4  00AE998 ARYQ 1300GB Enterprise io3 Flash Adapter for System x 4  00JY001 ARYR 2600GB Enterprise io3 Flash Adapter for System x 4  00JY004 ARYS 5200GB Enterprise io3 Flash Adapter for System x 2                     Withdrawn from marketing    For more information about these adapters  see the Lenovo Press Product Guides in the Internal Storage    category     http   www redbooks ibm com portals systemx  Open amp page pg amp cat internalstorage    Flex System x240 Compute Node  E5 2600 v2     32             GPU and Crypto adapters    The compute node supports the GPU and Crypto adapters listed in the following table     Note  These adapters are installed in an attached PCle Expansion Node     Table 21  GPU and Crypto adapters                                                       Partnumber   Feature code   Description Maximum  supported  94Y5960 A1R4 NVIDIA Tesla M2090  full height adapter  1   4702120 A4F1 NVIDIA GRID K1 for Flex System PCle Expansion Node it  4702121 A4F2 NVIDIA GRID K2 for Flex System PCle Expansion Node it  4702119 A4F3 NVIDIA Tesla K20 for Flex System PCle Expansion Node it  47C2137 ASHD NVIDIA Tesla K40 for Flex System PCle Expansion Node it  4702122 A4F4 Intel Xeon Phi 5110P for Flex System PCle Expansion Node it         When this double wide ada
57. x E5 2690 v2 10C 3 0GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    25MB 1866MHz 130W 1866 MHz hot swap Adapter 2 max  8737 9Mx   1x E5 2697 v2 12C 2 7GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open CN4022 1 used    30MB 1866MHz 130W 1866 MHz hot swap Adapter 2 max  Models without networking standard  8737 22x   1x E5 2620 v2 6C 2 1GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open Optional 0 used    15MB 1600MHz 80W 1600 MHz hot swap 2 max  8737 42x   1x E5 2650 v2 8C 2 6GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open Optional 0 used    20MB 1866MHz 95W 1866 MHz hot swap 2 max  8737 62x   1x E5 2670 v2 10C 2 5GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open Optional 0 used    25MB 1866MHz 115W 1866 MHz hot swap 2 max  8737 72x   1x E5 2680 v2 10C 2 8GHz 1x 8 GB LSI SAS2004   2x 2 5 inch Open Optional 0 used    25MB 1866MHz 115W 1866 MHz hot swap 2 max                     Processor detail  Processor quantity  model  cores  core speed  L3 cache  memory speed  power TDP rating      The 2 5 inch drive bays can be replaced and expanded with 1 8  solid state drive bays and a ServeRAID M5115   RAID controller to support up to eight 1 8 inch SSDs      Models have the following Ethernet controllers standard    e The x4x models include an Embedded 10Gb Virtual Fabric Ethernet controller  connections are routed using a  Fabric Connector  The Fabric Connector precludes the use of an I O adapter in I O connector 1    e The xMx models include a Flex System CN4022 2 port 10Gb Converged Adapter in slot
    