Home
Gefen GEF-MOD-32432 video switch
Contents
1. Download Current Configuration Restore Configuration Browse Waming All current settings will be lost SYSTEM CONFIGURATION Allows saving and loading of configuration files This feature allows the current state of the 32x32 Modular Matrix to be saved as a file This file can then be used to restore any previous configuration changes Restore Uploads the selected configuration file to the 32x32 Modular Matrix Download Click this button to download the current configuration to a file 93 RS 232 IP UDP CONTROL O NOTE As of this writing the firmware update procedure is not functional from within the Web interface This feature will be available in a future release of the product The firmware update procedure must be performed using RS 232 See page 98 Browse Update future implementation future implementation Selects the firmware file Updates the 32x32 Modular to be used to upgrade the Matrix with the selected 32x32 Modular Matrix firmware file Set Defaults TCP Teinet Terminal LOGIN SETTINGS Administrator Save Settings UDP Connection SETTINGS Remote UDP IP Address 192 1652206 Remote UDP Port 50021 WEB LOGIN SETTINGS Username Old Password Save Setti ings SYSTEM CONFIGURATION nt Confic tio Firmware Update UI ver 0 3 38 Browse Factory Reset Reboot Reset Click this button to s
2. 1080P PROGRESSIVE SEXIE Modular Matrix GEF MOD 32432 DVI e GEF MOD 324302 DVIELR GEF MOD 324932 DVI1FO GEF MOD 32492 FM10001FO GEF MOD 32432 DPDVI GEF MOD 30450 DPELR GEF MOD 32432 DP1FO User Manual www gefenpro com ASKING FOR ASSISTANCE Technical Support Telephone 818 772 9100 800 545 6900 Fax 818 772 9120 Technical Support Hours 8 00 AM to 5 00 PM Monday through Friday Pacific Time For 24 7 support see the back of the product for the support number Write To Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 www gefenpro com support gefenpro com Notice Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice 32x32 Modular Matrix is a trademark of Gefen LLC All trademarks are the property of their respective companies 2012 Gefen LLC All Rights Reserved All trademarks are the property of their respective companies Rev A1 CONTENTS INTRODUCTION e aa a a 1 EE E Vi E e E EE EE A ni dd dd E TEA 2 Package NC SS ii e E E e E RNE 2 Pre Configured ODlONS amaairos preso READ IC Bos ed DECIDE ais na Pi A a nee 3 EFRON Pane LOVOU Lone assino Saad GE O Sd DU Cara 8 Front Panel Descriptions ccccsntccosesescssaidesdnnccwaantdeviaecozdastdeedacenedantdesseadeahcoteesteasincesddundaecian 9 Back Panel Layo pira ap a 19 Back Panel DESCH WON Siiecescteseseustvetesttes che sece
3. The LED indicator will begin to flash rapidly indicating that the EDID is being recorded After the EDID has been successfully recorded the LED indicator will glow bright green 3 Disconnect the power supply from the Sender module 16 CONNECTING THE 32X32 MODULAR MATRIX 4 Disconnect the Sender module from the display 5 Repeat Steps 1 4 for each Sender module that will be used in the setup 6 Continue with instructions below in order to complete the connection process Connecting the Sender and Receiver Modules 1 Connect each of the included DVI FM 1000 Plus Sender modules directly to each DVI source device aa SS 2 Connect each of the included DVI FM 1000 Plus Receiver modules to each of the DVI inputs on the 32x32 Modular Matrix RECEIVER Zz e OS Continued on next page 17 CONNECTING THE 32X32 MODULAR MATRIX 3 Connect a single strand of SC terminated 50 1254 OM3e multimode fiber optic cable from each SC connector on the Sender module to each associated Receiver module ag to Source multimode fiber optic cable up to 3300 feet 1 kilometer E lt E CE to Matrix SS 4 Once the DVI source is powered the LED indicator indicated by the arrow on the Sender module will glow bright green No external power supply is required Receiver module NOTE If the LED indicator on the Receiver module does not turn Ee on then the SV fiber opti
4. x 19 D 447mm x 266mm x 482mm Shipping Weigh Esso ne eee einir tie ine eke ree eee eet eee eee 44 lbs 20 kg 103 WARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirec
5. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE 105 MA GEF MOD 32432k Rev A1 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefenpro com support gefenpro com D A CE amp BO This product uses UL or CE listed power supplies
6. ipconfig a calca a nara Cu TCP IP settings MAC add 00 1C 91 02 80 2B IP add 192 168 1 205 Net Mask 255 255 255 0 Gateway 192 168 1 1 Web Server Port 80 TCP Terminal Server Port 23 UDP Server Port 21 TCP Terminal password at login is set to OFF UDP Remote IP 192 168 2 206 UDP Remote Port 50021 UDP Access Enabled 49 RS 232 IP UDP CONTROL resetip Command The resetip command sets the current IP configuration to factory default settings Syntax resetip Parameters None Notes A reboot is required after using this command set_http_port Command The set_ http port command specifies the Web server listening port The default port setting is 80 Syntax set http port paraml Parameters param1 Port 0 255 Notes A reboot is required after using this command Example set http port 80 New HTTP port set to 80 50 RS 232 IP UDP CONTROL fset tcp term pass Command The set tcp term pass command sets the TCP terminal password Syntax set tcp term pass paraml param2 param3 Parameters param1 Old password 20 chars max param2 New password 20 chars max param3 New password confirm 20 chars max Notes A reboot is required after using this command Example set tcp term pass Admin reindeer reindeer TCP Terminal password updated to reindeer set_tcp_term_port Command The set_ tcp term port co
7. 100 TI 12 APPENDIX Finally repeat steps 3 through 9 using the MMTX UI version bin file This file updates the Web UI This file is relatively large and this process may take several minutes After the update process is complete the following will be displayed in the terminal window Verify Check sum please wait Download Completed Successfully MMTX UI e 0 3 38 bin Size 498240 Bytes Activate boot loader for UI board Please wait Gefen MMTX Boot Loader v 3 7 Checking program CS in SPI flash Please wait Erasing internal FLASH please wait Writing internal FLASH please wait ssssssssseseseseses Download Completed Successfully KKEKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UI FW version 0 3 38 KEKKKKKKKKKKKKKKKKKKKKK Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959600 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading The firmware update process is complete 101 RACK MOUNT SAFETY INFORMATION Maximum recommended ambient temperature 45 C 104 F Increase the air flow as needed to maintain the recommended temperature inside the rack Do not exceed maximum weight lo
8. 8 A24 D O Oo O O O O O O O O gt D gt gt gt P gt P P P P Pe gt D gt gt PP PDP N O O O O O O A 9 A17 A 0 O O OG O O O O O O gt gt gt P gt P P P P P Pe gt D gt gt FP PDP P oS Cc e O e 59 A10 A26 A11 A27 A13 A29 A 0 O O O O O O O O O O gt D gt FP PDP N O O O O O D gt gt PP PP P P PP P P P _ P D p gt DP P H O O O O O Oo Oo Oo O gt D gt gt gt P gt P P P PP Pe O O D p gt DD Pp P O SO OO O O Oo O O O O O gt D gt gt FP PDP N gt gt P gt P gt P P P P P P PP S O 2 O O O Oo amp O_O O gt gt gt PP P P P P P Pe O Oo O O O O O A14 A30 A14 A30 A 0 O O O O O 6 O O O gt gt gt P gt P P P P PS Pe gt D gt gt PP PDP P S OG O O O O gt D gt gt PP PDP P A15 A31 A15 A31 A 0 O 6 O O OG Oo O O O O O O A16 A32 A16 A32 D gt gt gt Pp P P PP P SP P P D p gt DD P H O O O O co Oo Oo Oo O O O O O O RS 232 IP UDP CONTROL savepreset Command The savepreset command saves the current routing and masking state to a specified preset To restore a saved preset use the callpreset command see page 57 Syntax Savepreset paraml Parameters param1 Preset 1 16 Example savepreset 2 Current routing state is saved to preset set_input_name C
9. 95 Firmware Update Procedures ges ecce sec tetinecvtancebansnacuectiodsdesdeensseatdcdiieiestedeonumebisdniedendeeakelaee 98 RACK MOUNT SAFETY INFORMATION cccccccccsssseeeeceeseeeeeeseeeeceeseeseseseeeeseeeeeeesaes 102 DPECIFICADONS ca ee ee mre eee Rd Rs cd E Se eter E ree perc eee 103 WARRANT scenes ceo ects a SL aaa cee semeecaeenaeeetn 104 MS NIN agai ssa ee ete ances reece A aE EE 105 IMPORTANT OPERATING NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE 32X32 MODULAR MATRIX There is no internal scaling in the 32x32 Modular Matrix All of the attached monitors must be able to display the output resolutions of the source devices For maximum compatibility it is recommended that only one compatible common resolution be used by all of the source devices e Routing features can be accessed using the serial control interface or via Telnet See page 37 74 for more information The 32x32 Modular Matrix has several The Gefen 32x32 Modular Matrix provides several different pre configured packages to suit the needs of your application This User Manual covers all available configurations See page 3 for information on identifying the type of 32x32 Modular Matrix that was purchased A IMPORTANT If the unit is installed in a closed or multi rack assembly do not block the ventilation holes of the enclosure INTRODUCTION Congratulations on your purchase of the 32x32 Modular Matrix Your complete satisf
10. DS460 PSUl PSOK Value PSU1 Imon Value PSU2 DS460 PSU2 PSOK Value 2625 mvolt PSU2 Imon Value 496 mV gt 5A Power result mV for all boards Power result mV for BP board 5V 3 3V 1 2V 1 2V 5056 3326 12121 1210 Power result mV for Inputs board 1038 mVolt 519 mV gt 5 A Board 3 3 5 1 2 3 3 1 8V 1 3290 120110 2 3398 120410 3 5126 3388 1810 4 5080 3342 1807 Power result mV for Outputs board Board 1 5 3 3 1 8V 1 5072 3282 1807 2 1009 3342 1815 2 1012 3300 L823 4 5078 330211793 73 f Command RS 232 IP UDP CONTROL The command enables disables the 5V on the specified input WARNING Use caution when applying power to inputs If the source device supplies 5V on the input then enabling the 5V may cause damage to the source and or the 32x32 Modular Matrix Syntax f paraml param2 Parameters param 1 param2 Example E 15 1 Input 1 32 State 0 1 oO Disable 74 RS 232 IP UDP CONTROL Using the Built in Web server The Web GUI is divided into four main pages Routing Status Manage EDID and Configuration Each of these pages is represented by a tab Click on the desired tab to open the its page Each page also has it s own set of tabs which can be accessed When the Web GUI is opened the Routing page tab will be displayed Routing gt gt Routing Tabs Click a tab to open the desired page Routing Status
11. Loading default EDID to all locals Inputs please wait Finished Loading 67 RS 232 IP UDP CONTROL fadefault Command The f adefault command resets the routing and masking to factory default settings This command is similar to the factory reset command except that the TCP IP settings are preserved Syntax fadefault Parameters None Example fadefault Reset to factory default Please wait ROGEING Lalg4 2 pess Unmasked all Outputs Loading default EDID to all locals Inputs please wait Finished Loading fw_upgrade Command The fw upgrade command is used to update the 32x32 Modular Matrix firmware See page 98 for details on using this command Syntax fw upgrade Parameters None Example See page 98 68 RS 232 IP UDP CONTROL help Command The help command displays the list of available RS 232 Telnet commands The help command can also be used to provide help on a specific command Syntax help paraml Parameters param1 Command optional Notes When asking for help on a specific command the character must be included as part of the command Examples help maskout Cmd maskout Mask outputs Syntax maskout paraml param8 amp Paraml 0 All outputs Paraml Param8 1 32 Outputs e g maskout 5 6 7 help Available cmds help ipconfig Sipadd snetmask Ssgateway set http port set tcp term port se
12. Syntax snetmask parami Parameters param1 Net mask Notes A reboot is required after using this command Example snetmask 255 255 255 0 New IP Mask set to 255 255 255 0 55 RS 232 IP UDP CONTROL Huse tcp term pass Command The use_ tcp term pass command enables or disables the login credentials when starting a terminal session Syntax use tcp term pass paraml Parameters param1 State 0 1 o Disable _ O Notes A reboot is required after using this command Example use tcp term pass 1 TCP Terminal password at login is set to ON use_udp_access Command The use udp access command enables or disables UDP access mode Syntax use udp access parami Parameters param1 State 0 1 va menin o Disable i O Notes A reboot is required after using this command Example use udp access 1 UDP Access is set to Enabled 56 RS 232 IP UDP CONTROL callpreset Command The callpreset command restores the specified routing masking preset Syntax callpreset paraml Parameters param1 Preset 1 16 Notes If the specified preset is empty then Empty Set will be returned Examples callpreset 2 Recalling the saved touting state from preset 2 callpreset 3 Recalling the saved touting state from preset 3 Empty Set 57 RS 232 IP UDP CONTROL maskout Command The maskout command masks the specified outpu
13. XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT XPT Monitor name GEFEN XPT SL GEFEN XPT SL PanasonicTVO PanasonicTVO PanasonicTVO PanasonicTVO PanasonicTVO PanasonicTVO GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ GEFEN _ SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL 46 RS 232 IP UDP CONTROL prloedid Command The prloedid command displays the EDID stored in the specified input Syntax fprloedid paraml Parameters param1 Input 1 32 Example prloedid 3 Print the local Input 3 on terminal screen please wait 0x00 OxFF OxFF OxFF OxFF OxFF OxFF 0x00 0x34 0xA9 0xAF 0xA0 0x01 0x01 0x01 0x01 0x00 0x14 0x01 0x03 0x80 0x00 0x00 0x78 OxOA OxDA OxFF 0xA3 0x58 Ox4A OxA2 0x29 0x17 0x49 0x4B 0x00 0x00 0x00 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x02 0x3A 0x80 0x18 0x71 0x38 0x2D 0x40 0x58 0x2C 0x45 0x00 OxBA 0x88 0x21 0x00 0x00 0x1E 0x01 0x1D 0x80 0x18 0x71 0x1C 0x16 0x20 0x58 0x2C 0x25 0x00 OxBA 0x88 0x21 0x00 0x00 0x9E 0x00 0x00 0x00 OxFC 0x00 0x50 0x61 Ox6E 0x61 0x73 Ux6F 0x6E 0x69 0x63 0x54 0x56 0x30 0x0A 0x00 0x00 0x00 OxFD 0x00 0x17 0x3D 0x0F 0x44 0x0F 0x00 0x0A 0x20 0x20 0x20 0x20 0x20 0x20 0x01 0xC7 0x02 0x03 0x2A 0x71 0x49
14. command routes the specified input to the specified outputs Only one input can be specified at a time However up to eight outputs can be specified at a time Do not precede this command with the symbol Syntax r parami param2 param9 Parameters param1 Input 1 sa 32 param2 Output KEES A Notes If param2 0 then the specified input will be routed to all outputs The s command will perform this same function See the next page for details on the s command Examples r1i23789 Input 1 is routed to Outputs 2 3 78 9 E Sb Input 5 is routed to all Outputs 65 RS 232 IP UDP CONTROL s Command The s command routes the specified inputs to all outputs Do not precede this command with the symbol Syntax S parami Parameters param1 Input 1 32 Notes If param1 0 then the matrix is placed in a 1 to 1 routing state This means that Input 1 is routed to Output 1 Input 2 is routed to Output 2 and so on Examples S 2 Input 2 is routed to all Outputs s 0 Routing 1 1 2 72pasa 66 RS 232 IP UDP CONTROL hpdto Cycles the HPD line on the specified output factory_reset Command The factory reset command resets the matrix to factory default settings Syntax factory reset Parameters None Example factory reset IP configuration reset to factory default Reset to factory default Please wait Routing Lady 2 27 aces Unmasked all Outputs
15. or Input Input 3 in this field Click 4 Input 4 the Save Changes 5 button or click the Input 5 Cancel button to 6 Input 6 restore the previous eae name Save Changes cancel Saves the current changes Restores the previous names for each Input and or Output if a change was made 80 RS 232 IP UDP CONTROL Routing gt gt 5V A WARNING Use caution when applying power to inputs If the source device supplies 5V on the input then enabling the 5V may cause damage to the source and or the 32x32 Modular Matrix Refresh Updates the Web page to reflect the new Input and or Output Name cA Ga PRO Routirl Status Manage EDID Configuration R g Preset Names VO Names 5V Refresh Warning Use caution when applying power to Inputs It may damage your equipment LOCK Power 5 VOLT Input Name 5V 1 input 1 16 Input_16 input_31 Input Indicates the number of each Input If the input has 5V enabled it will be highlighted in green as shown Name The current name of each input 5V Click to select the desired Input s Selecting an input does not automatically enable the 5V Use the Set button to enable the 5V 81 LOCK Power Enables disables the power lock state See the RS 232 command tlock fo command on page 70 for more information 32x32 Modular Matrix Log Out ee hs Mar Input 1 Input 2 Input 3 I
16. 0x90 0x05 0x20 0x04 0x03 0x02 0x07 0x06 0x01 0x23 0x09 0x07 0x01 0x73 0x03 0x0C 0x00 0x20 Ux00 0xB8 0x2D 0x2F 0xC0 0x07 0x81 0x49 0x01 OxFE 0x06 0x08 0x00 0x00 0x00 0xE3 0x05 Oz 0x01 0x01 0x1D 0x00 0x72 0x51 0xDO 0x1E 0x20 0x6E 0x28 0x55 0x00 DxBA 0x88 0x21 0x00 0x00 0x1E 0x8C Ox0A 0xD0 0x8A 0x20 0xE0 0x2D 0x10 0x10 0x3E 0x96 0x00 OxBA 0x88 0x21 0x00 0x00 0x18 0x8C 0x0A 0xDO 0x8A 0x20 0xE0 0x2D 0x10 0x10 0x3E 0x96 0x00 0x0B 0x88 0x21 0x00 0x00 0x18 Ox8C 0x0A OxAO 0x14 0x51 OxFO 0x16 0x00 0x26 0x7C 0x43 0x00 OxBA 0x88 0x21 0x00 0x00 0x98 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x76 47 RS 232 IP UDP CONTROL fset bank name Command The set_ bank name command sets the name of the specified EDID bank Syntax set bank name paraml param2 Parameters param1 EDID Bank 1 20 param2 Name 20 chars max Notes Spaces are not permitted when naming EDID banks If a space is required use the underscore character _ Example set bank name 3 Dell 30 Dell 30 16 assigned Lo bank 3 show_bank_name Command The show_bank name command displays the name of the specified EDID bank Syntax show bank name parami Parameters param1 EDID Bank 1 20 Example show bank name 3 Bank 3 Dell 30 48 RS 232 IP UDP CONTROL ipconfig Command The ipconfig command displays all TCP IP settings syntax ipconfig Parameters None Example
17. 2 168 1172 Subnet 255 255 255 0 Gateway 192 166 515254 HTTP Port 80 Telnet Port 23 1 Connect an RS 232 cable from the PC to the 32x32 Modular Matrix Also make sure that an Ethernet cable is connected between the matrix and the network 2 Launch a terminal emulation program e g HyperTerminal and use the RS 232 settings listed on page 37 UDP settings will need to be assigned Consult your network administrator to obtain the proper settings O NOTE Depending upon the network all related IP Telnet and 3 Setthe IP address for the matrix using the sipadd command see page 55 for details 4 Set the subnet mask using the snetmask command see page 55 for details 5 Set the gateway router IP address using the sgateway command see page 53 for details 6 Set the Telnet listening port using the set_ tcp term port command see page 51 for details 7 Setthe HTTP listening port using the set http port command see page 50 for details 8 Power cycle the matrix to reboot and complete all IP setting changes 9 Type the IP address that was specified in step 3 in a web browser to access the Web GUI or use the same IP address to Telnet to the matrix UDP Configuration 1 Set the UDP remote IP address for the matrix using the set_ udp rip command see page 52 for details 2 Setthe UDP listening port for the matrix using the set udp port command see page 52 for details 3 Set the UDP remote port f
18. 28 on 20 29 29 on ov 3 90 on ao 31 31 on 31 32 32 on 32 Choci Save Routing Preset 1 Preset_l gt Save Recall Routing Preset 1 Preset 1 Save Routing Preset Saves the current routing state to memory Click the drop down list to select the desired routing preset then click the Save button to save the preset to memory 7 Recall Routing Preset Loads the selected routing state into memory Click the drop down list to select the desired routing preset then click the Recall button to load the preset into memory 78 RS 232 IP UDP CONTROL Routing gt gt Preset Names Refresh Updates the Web page to reflect the new Preset Name 32x32 Modular Matrix Status Manage EDID Configuration Preset Cancel Preset Preset 3 Preset 4 Preset 5 Preset 6 Name Type the desired name of the Preset in this field Click the Save Changes button to save the Preset Name Click the Cancel button to restore the previous name Save Changes Cancel Saves the current changes Restores the previous names for each Preset if a change was made 79 RS 232 IP UDP CONTROL Routing gt gt I O Names Refresh Updates the Web page to reflect the new Input and or Output Name Modular Matrix Input_1 Name Type the desired 2 Input 2 name of each 3 nmt 3 Output
19. Connect both AC power cords from the 32x32 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recommended to connect each power cord to electrical outlets on two separate circuits Power to the Receiver unit is delivered from the power supply in the matrix over the CAT 5e cable using Gefen Power Over Line POL technology The Link indicator will glow bright green to indicate a solid connection between the matrix and the Receiver unit The Power indicator will glow bright blue to indicate that the Receiver unit is being powered If either of these LED indicators are OFF inspect the CAT 5 cable for loose connections or possible defects GEF MOD 32432 DVI1FO 1 Connect up to 32 DVI sources to the DVI inputs on the rear panel of the 32x32 Modular Matrix using DVI cables 2 Connect a single strand of SC terminated 50u OM3e multimode fiber optic cable from each SC connector on the Sender card to each Receiver unit as shown below T a m Multimode Fiber Optic cable Up to 6600 feet 2 kilometers 14 CONNECTING THE 32X32 MODULAR MATRIX 50u OM3e OM3 and 62 54 OM1 multimode fiber optic cable can be used However the maximum extension distance will be dependent upon the type of fiber optic cable used Refer to the table below multimode 50u OM3e 6600 feet 2 kilometers multimode 50u OM3 2000 feet 600 meters multimode 62 5u
20. MATRIX 3 Press the Set button to complete the operation The system will remain in Save Current Preset Mode The front panel LCD screen will indicate that the current routing state has been recalled 30 OPERATING THE 32X32 MODULAR MATRIX Masking Outputs Masking prevents the output device display etc from receiving an output signal instead of powering down the output device The masking process is identical for masking or unmasking outputs 1 Press the Mask button to activate Mask Mode 3 pl 3 The front panel LCD screen will indicate that the 32x32 Modular Matrix is in Mask Mode 31 OPERATING THE 32X32 MODULAR MATRIX 2 Select the Output A1 D8 to be masked 3 Press the Set button to complete the operation fe 4 The front panel LCD screen will indicate that the selected output has been masked 32 OPERATING THE 32X32 MODULAR MATRIX Managing EDID Saving the Downstream EDID data to Local memory 1 Press EDID button once to activate DSTOLO Downstream To Local Mode The front panel LCD display will show the following 2 Press the Output button A1 D8 to select the EDID source OPERATING THE 32X32 MODULAR MATRIX 3 Press any Input button A1 D8 to select the EDID data destination 4 Press the Set button to complete the operation Press the Set button J lo 5 k RM th le i 3 ke 34 OPERATING THE 32X32 MODULAR
21. MATRIX Saving the Default EDID data to Local memory 1 Press the EDID button twice to activate DETOLO Default To Local Mode ny The front panel LCD will display the following 2 Press any Input button s A1 D8 to select the EDID data destination s 35 OPERATING THE 32X32 MODULAR MATRIX 3 Press the Set button to copy the default EDID to the selected Input le ec The front panel LCD will indicate that the EDID is being copied After a few moments the front panel LCD will indicate that the EDID copy process has completed 36 RS 232 IP UDP CONTROL RS 232 Interface 59 43 2 1 RS 232 Controller Matrix o ON QO Oa FPF OO N gt o OA N ODO Oa FF W N gt Only TXD RXD and GND are used RS232 Settings Ba dtate enren ee a aucune AD E 19200 Bata DIS ea a E a DRE ERR e 8 PDE eisiaa a E E A None OP D r a a A RE RE ERR Re EEE RE 1 Fow Control eree E E E E None IMPORTANT When sending RS 232 commands a carriage return must be included at the end of the command A space must be included between the command and the parameter 37 RS 232 IP UDP CONTROL IP Configuration The 32x32 Modular Matrix supports IP based control using Telnet UDP or the built in Web based GUI To set up IP control the network settings for the 32x32 Modular Matrix must be configured via RS 232 The default network settings for the matrix are as follows IP Address 19
22. Manage EDID Configurati Routing Preset Names lO Names 5V 32x32 Modular Matrix outin Status Manage EDID Configuration Routin Preset Names VO Names 5V Output Masks 10 10 LOCK Matrix Locks unlocks the matrix When the Matrix is locked no modifications can be made using the Web GUI Output The port number of the output The blue highlight indicates that the output has been masked See page 83 for more information on masking outputs Input Displays the input that has been routed to the output In the illustration above Input 22 has been routed to Output 1 HPD Indicates the Hot Plug Detect HPD status of the input 75 RS 232 IP UDP CONTROL OUTPUTS Provides information on each Output on the matrix Name Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 FOPT OUT Rome D Notmstea EE masteo O mo E sy E muro ELR OUT gogagopgogagoao Type Displays the type of output card used in slot FOPT OUT Modular Matrix 8 DVI Sender over 1FO GEF DVI 8FO S ELR OUT Modular Matrix 8 DVI Sender over CAT 5 Card GEF DVI 8ELR S DVI OUT Modular Matrix 8 DVI Output Card GEF MOD 8DVI O Output Click to place a check mark in the box and select the desired output Multiple outputs can be selected at a time Name Displays th
23. Matrix to display the current routing state By default all inputs are routed to their respective outputs e g A1 A1 A2 A2 C3 C3 D5 D5 etc 21 q 2 OPERATING THE 32X32 MODULAR MATRIX Routing Sources To change the current routing state press the Set button to activate Routing Mode The front panel LCD will indicate that Routing Mode has been selected Press the desired Output button s from the top two rows of push buttons One or more Output buttons may be selected OPERATING THE 32X32 MODULAR MATRIX 3 Select any Input from the bottom two rows of buttons A1 D8 corresponding to the source to be displayed on the output s 4 Press the Set button again to complete the operation i cc ci te ON e U d d The front panel LCD display will indicate that the routing process is complete 23 OPERATING THE 32X32 MODULAR MATRIX Locking the Matrix Locking the Matrix prevents changes to any of the Matrix settings This feature is useful in case any of the front panel buttons are pressed by accident Locking the Matrix also prevents changes using the IR Remote Control Unit 1 Press the Lock button to activate System Lock Mode ema The front panel LCD screen will display the following while in System Lock Mode 2 Press the Lock button a second time to deactivate System Lock Mode OPERATING THE 32X32 MODULAR MATRIX Using the Cancel button P
24. OM1 660 feet 200 meters Connect the power supply to the 1FO Receiver unit then connect the power supply to an available electrical outlet GEF DVI 1FO R DVI cable DVI display Connect both AC power cords from the matrix to available electrical outlets Connecting both AC power cords will provide power redundancy should one of the power supplies fail It is recommended to connect each AC power cord to separate circuits The Link indicator on the Receiver unit will glow bright green to indicate a connection between the matrix and the Receiver unit If the Link indicator is OFF then inspect the fiber optic cable for loose connections or possible defects The Power indicator will glow bright blue to indicate that the Receiver unit is powered 15 CONNECTING THE 32X32 MODULAR MATRIX GEF MOD 32432 DVIFM10001FO The GEF MOD 32432 FM10001FO package comes with 32 pairs Sender Receiver of DVI FM 1000 Plus fiber optic modules allowing you to connect a DVI source device up to 3300 feet 1 kilometer away from the matrix A IMPORTANT Before using the DVI FM 1000 PLUS fiber optic extenders the Sender module must first be programmed with the EDID from the display sink device Virtual EDID Programming Procedure 1 Power on the DVI display and connect the DVI FM1000 PLUS Sender module directly to the DVI port of the display E 2 Connect the 5V DC power supply to the power receptacle on the Sender module
25. action is very important to us GefenPRO In the realm of video distribution certain features are invaluable in a commercial or broadcast environment Accommodations such as a build in power supply and flat black rack mount enclosures set GefenPRO apart from our traditional products Complex distribution units allow for professional DVI 3G SDI and HDMI signals to be routed and converted easily and seamlessly while being backed up by a renowned and dependable technical support team Gefen invites you to explore the GefenPRO product line and hopes that you find the solution that fits your needs The Gefen 32x32 Modular Matrix The GefenPRO 32x32 Modular Matrix provides an all in one professional grade solution to route up to 32 DVI sources to any 32 DVI displays with resolutions up to 1920 x 1200 The modular design of this matrix provides the ultimate in flexibility by allowing the use of any combination of DVI ELR or 1FO output modules in any of its four output slots This feature allows the GefenPRO 32x32 Modular Matrix to function as both a Matrix and as an Extender The front panel LCD displays the current routing status and each DVI source is accessible to any display by using the front panel push buttons via the RS 232 interface or through IP Control built in Web server and Telnet Hot swappable dual redundant power supplies allow these matrixes to be used for applications in demanding applications where enhanced reliability ease of
26. ads for the rack Install heavier equipment in the lower part of the rack to maintain stability Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Connect a bonding wire between an approved safety ground and the grounding screw on the chassis 102 SPECIFICATIONS Maximum Pixel ClOCK ccccccceseccceesecceceeeeceseeeeeceseeeceeeseecesseueceesseeeeesaueeesaaeeeees 165 MHz grojb audio cia io o gs RED RR RR DER DDD RIC FED 1 2V p p DVI Input COMME CON Si ccccvesecacectecasedcece cnensncecnndadeetederiaietevens 32 organized into banks of 8 depending upon the type of input card used e DVI 8 DVI I 29 pin female e DisplayPort 8 female Output Connector S si aaccceccosacpsccesssntsdetactcanseseuceaiaszaciacgtasannes 32 organized into banks of 8 depending upon the type of output card used e DVI 8 DVI I 29 pin female e ELR 8 RJ 45 Fiber 8 SC RS 232 serial POR saida LA O OO A T agia DB 9 female Ethernet IP control port assspsaasssiesssiesio nestas Eid na RJ 45 jack 100BaseT Power SUpDIi S ccsccecceeseseeeeeeeeeeeseeeeeseeees 2 100 240V AC dual IEC hot swappable Rack Mountabl6 ca ass cnsinisaieassadasdd cad cessa inasiaa dei nda dias dna inas 6U rack height rack ears included Dimensions W x H X D 17 6 x 10 5
27. ails on the available pre configured options INTRODUCTION Pre Configured Options Before reading this User Manual familiarize yourself with the rear panel of the 32x32 Modular Matrix The 32x32 Modular Matrix can accommodate up to four output cards and four input cards Each card provides eight connectors providing a total of 32 inputs and outputs The 32x32 Modular Matrix is sold pre configured with a combination of input and output cards best suited for the needs of your application We will cover each configuration in the next section First we will identify the location of each input and output card on the matrix i NOTE When a card is not installed it is recommended that a cover plate be installed over the expansion bay to prevent dust and other foreign particles from entering the matrix Matrix Layout The bottom four expansion bays of the matrix only accept input cards The top four expansion bays only accept output cards Each expansion bay on the matrix is identified with a letter A B C and D from top to bottom see next page The inputs and outputs are numbered on each card from left to right Blue LEDs on each card indicate that the card is properly powered Refer to page 10 for detailed information on the rear panel layout Cover plate Power indicator Output bays INTRODUCTION Input bays The following list outlines the available pre configured options Because this User Manual covers i
28. and sets the new IP gateway The gateway must be typed using dot decimal notation The default gateway is 192 168 1 254 Syntax Sgateway paraml Parameters param1 Gateway Notes A reboot is required after using this command Example Sgateway 192 168 1 1 New IP Gateway set to 192 168 1 1 53 RS 232 IP UDP CONTROL show_tcp_term_pass Command The show tcp term pass command displays the current TCP terminal password The default TCP terminal password is Admin Syntax show tcp term pass Parameters None Example show tcp term pass TCP Terminal password reindeer show_user_name Command The Show user name command displays the current TCP terminal user name The default TCP terminal user name is Administrator Syntax show used name Parameters None Example show user name TCP Terminal login Administrator 54 RS 232 IP UDP CONTROL sipadd Command The sipadd command sets the IP address of the matrix The IP address must be typed using dot decimal notation The default IP address for the matrix is 192 168 11 75 Syntax Sipadd parami Parameters param1 IP address Notes A reboot is required after using this command Example sipadd 192 168 2 127 New IP set to 192 168 1 205 snetmask Command The snetmask command sets the IP subnet mask The net mask must be typed using dot decimal notation The default net mask is 255 255 255 0
29. c feature must be enabled on the 32x32 Modular Matrix Refer to the 32x32 Modular Matrix User Manual for details on using this feature 18 CONNECTING THE 32X32 MODULAR MATRIX DisplayPort package options Each DisplayPort package is based on the DVI package options except for the fact that all inputs will be DisplayPort instead of DVI Refer to the connection instructions for the DVI version of each package if needed e GEF MOD 32432 DPDVI based on the GEF MOD 32432 DVI 1 Connect the up to 32 DisplayPort sources to the DisplayPort inputs on the matrix 2 Connection up to 32 displays to the DVI outputs on the matrix using DVI cables 3 Power the matrix GEF MOD 32432 DPELR based on the GEF MOD 32432 DVIELR 1 Connect the up to 32 DisplayPort sources to each DisplayPort input on the matrix 2 Connect a CAT 5e cable or better up to 330 feet 100 meters from each ELR POL jack on the output card to each of the included ELR POL Receiver units 3 Power the matrix Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the Matrix card and the Receiver unit The POL indicators will glow bright amber to indicate that the Receiver unit is being powered GEF MOD 32432 DP1FO based on the GEF MOD 32432 DVI1FO 1 Follow the Virtual EDID Programming Procedure starting on page 16 2 Connect up to 32 DisplayPort sources to the DisplayPort inputs on the matrix 3 Conne
30. ce to the selected input s Cancel Clears all cneck marks from each box 87 RS 232 IP UDP CONTROL 32x32 Modular Matrix Log Out EDID Lock Copy EDID From INPUTS meus wame e000 Source comman 1 input 2 E input 2 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input amp Input 9 Input 10 Input 11 Input 20 input 28 Input 29 Input 30 oon oon fk oO he com cones 10 0000o05o00oq DID Source Output 25 Output 25 Output 25 Output 25 Output 25 Output 25 Output 25 Output 25 EDID Source Checkbox Displays the EDID source used by the Click to select the Input s to where the input In the illustration above the EDID source will be copied Selecting EDID source is Output 25 an input does not automatically copy the EDID source Click the Copy button to EDID Name copy the EDID to the input Displays the name of the EDID Input Indicates the number of each input Name The current name assigned to each input 88 RS 232 IP UDP CONTROL Manage EDID gt gt Bank Names 32x32 Modular Matrix Routing Status Manage EDID Configuration Bank Bank 2 Bank 4 Bank 6 Bank Bank 2 Ba nk 3 Bank 4 Bank 5 Bank amp Bank Bank 8 Bank 9 Save Changes O co OM oo amp amp N Bank Indicates the EDID bank number Name Type the d
31. channels Board SN 981708 FW ver 0 3 8 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading 99 10 APPENDIX Repeat steps 3 through 9 using the MMTX DVIinout version bin file The update process for the Input Output boards may take several minutes After the update process is complete the following will be displayed in the terminal window Verify Check sum please wait Download Completed Successfully MMTX DVIinout e 0 3 8 bin Size 68640 Bytes Activate boot loader for all IN OUT boards Please Warte esea aara d eme ba emd aa ge a ee Finished loading new FW version to all IN OUT boards The system will reboot itself please wait kkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxxkxx kxx xx GEFEN Modular MultiMatrix UI FW version 0 3 38 kkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxxkxxk kxx xxk Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Board 3 Board Type DVI input 8 channels Board SN 954849 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading
32. ct a single strand of SC terminated 50 OM3e multimode fiber optic cable from each SC connector on the Sender module to each Receiver module 50u OM3e OM3 and 62 5u OM1 multimode fiber optic cable can be used However the maximum extension distance is dependent upon the type of fiber optic cable used 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable 2000 feet 600 meters using 50u OM3 multimode fiber optic cable 660 feet 200 meters using 62 5u OM1 multimode fiber optic cable 3 Connect the power supply to the 1FO Receiver unit then connect the power supply to an available electrical outlet 4 Power the matrix 19 OPERATING THE 32X32 MODULAR MATRIX Booting Up Standby Screen The front panel LCD of the 32x32 Modular Matrix is a 16 character 2 line display This display is used to aid in performing routing commands as well as displaying additional system information When the unit is powered on the following screens are displayed After a few moments the standby screen is displayed 20 OPERATING THE 32X32 MODULAR MATRIX Displaying the Current Routing State To display the current routing status of the Matrix press any one of the Input or Output buttons on the front panel In the example above Input A1 is routed to Output A4 Output A5 Output A7 Output A8 Output B1 Output B2 Output B3 Output C3 Output C5 and Output C6 A source does not need to be connected to the
33. deg 1 3202 my 5064 my 981809 0 03 08 50 C deg 35 deg 1 3334 my 1008 my 1614 my 85 S N Type FAW Ver Tempi Temp2 Connection Power 3 3v Power 5 0v Power 1 8v S N Type FAW Ver Tempi Temp Connection Power 3 3v Power 5 0v Power 1 8v 959793 DP IN 0 03 08 40 C deg 32 C deg 1 1207 mv DP_IN 0 03 08 37 C deg 10 C deg 1 1204 mw 0 my RS 232 IP UDP CONTROL Status gt gt System The Status gt gt System tab provides additional detailed information on the 32x32 Modular Matrix hardware The information presented on this screen is used by Gefen Technical Support for troubleshooting purposes only 32x32 Modular Matrix Log Out SIN mm E FAW Ver me ae MSTemp PTemp Power 3 3v Power 5 0v Core Power IO Power Fans Fans Fans3 86 RS 232 IP UDP CONTROL Manage EDID gt gt Assign EDID Lock Secures the Local EDID and disables the automatic loading after power up See the lock edid command on page 42 for more information Copy EDID From Select the EDID from the drop down list The EDID will be copied from the selected destination to the desired input s Options Default EDID Bank 1 Bank 20 Output 1 Output 32 Copy EDID From Default EDID Check All Places a check mark in all boxes Clear All Clears all check marks from each box Copy Copies the EDID sour
34. didtolo parami Parameters param1 Input Ta 02 Notes If p param1 0 then the downstream EDID is stored in all 32 inputs Example loedidtoba 8 Download EDID bin file 1 cancel 0 Please send EDID bin file Waiting for the file to be sent press a to abort 43 RS 232 IP UDP CONTROL prbaedid Command The prbaedid command displays the EDID stored in the specified EDID bank Syntax prbaedid paraml Parameters param1 Bank 1 20 Example prbaedid 20 Print the Bank EDID 20 on terminal screen 0x00 OxFF OxFF OxFF OxFF OxFF OxFF 0x00 0x10 0xAC 0x35 0x40 0x4C 0x32 0x33 0x32 0x31 0x13 0x01 0x03 0x80 0x41 0x29 0x78 OxEA Ox8F 0x95 OxAD Ox4F 0x32 OxB2 0x25 OxOF 0x50 0x54 OxAS Ox4B 0x00 0x81 0x80 OxA9 0x40 OxD1 0x00 OxD1 0x40 0x71 Ox4F 0x81 0x00 0xB3 0x00 0x01 0x01 0xB0 0x68 0x00 0xA0 OxAO 0x40 0x2E 0x60 0x30 0x20 0x36 0x00 0x81 0x90 0x21 0x00 0x00 Ox1E 0x00 0x00 0x00 OxFF 0x00 0x47 0x35 0x30 0x31 0x48 0x39 0x43 0x32 0x32 0x33 0x32 0x4C 0x0A 0x28 0x3C 0x80 0xA0 0x70 0xBO 0x23 0x40 0x30 0x20 0x36 0x00 0x81 0x91 0x21 0x00 0x00 0x1C 0x00 0x00 0x00 OxFD 0x00 0x31 0x56 0x1D 0x71 0x1C 0x00 Ox0A 0x20 0x20 0x20 0x20 0x20 0x20 0x00 0x41 44 RS 232 IP UDP CONTROL prdsedid Command The prdsedid command displays the specified downstream EDID Syntax prdsedid paraml Parameters param1 Output 502 Example prdsedid 20 Print the Downstream EDID 25 on term
35. display eer param2 EDID bank offset 1 20 Example ediddstoba paraml param2 Loading Downstream EDID 25 to EDID bank 20 please wait Finished Loading ediddstolo Command The ediddstolo command reads the downstream EDID and stores it to a Local EDID Syntax ediddstolo paraml param2 param3 param9 Parameters param1 A downstream display asse param2 param9 Input list 1 ais DZ Notes If param2 0 then the downstream EDID is stored in all 32 inputs Example tediddstolo 25 6 7 Loading Downstream EDID 25 to locals Inputs 6 7 please wait Finished Loading 41 RS 232 IP UDP CONTROL lock_edid Command The lock edid command secures the EDID stored on all inputs This prevents the default EDID from being loaded to all inputs during a power up procedure This feature can be enabled or disabled Syntax lock edid paraml Parameters param1 EDID lock state O 1 o Disable loedidtoba Command The loedidtoba command loads an EDID file and stores it in the specified EDID bank Syntax loedidtoba parami Parameters param1 Bank 1 20 Example loedidtoba 8 Download EDID bin file 1 cancel 0 Please send EDID bin file Waiting for the file to be sent press a to abort 42 RS 232 IP UDP CONTROL loedidtolo Command The loedidtolo command loads an EDID file and stores it in the specified input Syntax loe
36. e rebooted for any changes to take effect MAC Address 00 1 91 02 80 2B IP Address 192 168 1 205 Subnet Gateway HTTP Port TGP Telnet Terminal Port UDP Port 32x32 Modular Matrixk HTTP Port Administrator New Password Confirm New Password Username Old Password SYSTEM CONFIGURATION onfiguration Download 91 RS 232 IP UDP CONTROL TCP Telnet Terminal LOGIN SETTINGS Sets the user name and password for Telnet sessions to the 32x32 Modular Matrix Click the Save Settings button to apply changes Click the Force Password on Connect check box to have the 32x32 Modular Matrix prompt for a password each time a Telnet session is started User Name Administrator Old Password New Password Contin New Password Force Password on Gonnect Remote UDP IP Address 192 168 2206 Remote UDP Port 50021 Enable UDP Access UDP Connection SETTINGS Sets the remote UDP IP Address and Port Click the Save Settings button to apply changes Click the Enable UDP Access check box to 92 RS 232 IP UDP CONTROL WEB LOGIN SETTINGS Sets the user name and password for Web Interface sessions using the 32x32 Modular Matrix Click the Save Settings button to apply changes Username Old Password New Password Operator Confirm New Password
37. e current name of the output The name of each output can be changed See page 80 for details Check All Clear All Check All Places a check mark in each box under the Output column Clear All Clears all check marks from the Output column 76 RS 232 IP UDP CONTROL INPUTS Provides information on each Input on the matrix 32x32 Motclular Matrix Input 1 1 ini Input 2 Er nput3 O 3 Input 4 O 4 ST Input 5 Oo 5 Input 6 6 Input 7 7 Input 8 8 Input 9 Input 10 40 Input 11 O 1 Input 12 12 Input 13 O Route Click this button to route the current input and output selection s Name Displays the current name of the input The name of each input can be changed See page 80 for details Input Click the radio button next to the desired input to be routed Only one input can be selected at a time Type Displays the type of input card used in slot DVI IN Modular Matrix 8 DVI Input Card GEF MOD 8SDVI I DP OUT Modular Matrix 8 DisplayPort Card GEF MOD 8DP 1 7 RS 232 IP UDP CONTROL Legend Provides color coded information on the status of each Input and Output ein PRG 32x32 Modular Matrix Routing Status Manag EDIO Configuration Log Out Routing Preset Names VO Names 5V Output Masks 8535 ggegegeseeesgeeseeeegee Q YN BP 26 on 26 27 on 27 a
38. ected to a grounded electrical socket 12 CONNECTING THE 32X32 MODULAR MATRIX GEF MOD 32432 DVI GEF MOD 32432 DPDVI Connect up to 32 DVI sources to the DVI inputs on the rear panel of the 32x32 Modular Matrix using DVI cables 2 Connect up to 32 DVI displays to the DVI outputs on the rear panel of the 32x32 Modular Matrix 3 Connect both AC power cords from the 32x32 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recommended to connect each power cord to electrical outlets on two separate circuits GEF MOD 32432 DVIELR Connect up to 32 DVI sources to the DVI inputs on the rear panel of the 32x32 Modular Matrix using DVI cables N Connect a CAT 5e cable or better up to 330 feet 100 meters from each ELR POL jack on the Sender card to each of the included ELR POL Receiver units as shown below CAT 5e cable Up to 330 feet 100 meters Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the output card and the Receiver unit The POL indicators will glow bright amber to indicate that the Receiver unit is being powered Continued on next page 13 CONNECTING THE 32X32 MODULAR MATRIX 3 Connect a DVI cable from the DVI Out port on each ELR POL Receiver unit to a DVI display GEF DVI ELRPOL R DVI cable DVI display 4
39. el Descriptions 1 Out 1 32 Connect the output devices to these ports Output banks are shown using the GefenPRO ELR POL Extender GEF DVI 8ELR S the GefenPRO Fiber Optic Extender GEF DVI 1FO S and the Gefen DVI Output Board GEF MOD 8DVI O 2 Power Input Output boards Each Input and Output card has its own power indicator This LED indicator will glow bright blue when the card is properly installed and the power to the 32x32 Modular Matrix is applied 3 Cover Plate In the event that an Output or Input board is not required the cover plate can be installed to prevent foreign particles or objects from entering the system 4 In 1 32 Connect the source devices to each of these ports At the time of this writing only DVI input modules are available 5 RS 232 Serial Port Connects to the RS 232 control device The 32x32 Modular Matrix may be switched remotely using this port See page 37 74 for more information 6 IP UDP Telnet Control Connect the 32x32 Modular Matrix to a network in order to use IP UDP Telnet control 7 IR Connect an IR extender to this IR port 8 Power This LED indicator glows bright blue when the matrix is powered on 9 Power Supply 1 2 Connect the included AC power cords from these receptacle to an available electrical outlet The redundant secondary power cable should be connected to an electrical outlet on a different circuit Each power supply is 110 220V AC 10 Grounding Termina
40. esired name of the EDID bank in this field Click the Save Changes button to save the bank name Click the Cancel button to restore the previous name Save Change Save Changes Cancel Saves the current name Restores the previous names for each EDID change to the EDID bank s bank if a change was made 89 RS 232 IP UDP CONTROL Manage EDID gt gt Upload Download 32x32 Modular Matrix select EDID File to Upload Select Bank Location Select Bank Upload Browse Click this button to upload the EDID Click this button to to the specified bank select the EDID file to be uploaded Select Bank Location Click this drop down list to select the bank Drop down list to where the EDID will be uploaded Click this box to select the EDID that is to be saved Options to a file The EDID file will Bank_1 Bank_20 be saved in binary format bin Options Download Click this button to download the selected EDID to a file Bank 1 Bank 20 Output 1 Output 32 Input 1 Input 32 90 RS 232 IP UDP CONTROL Configuration CHANGE IP SETTINGS Assigns IP address subnet gateway HTTP listening port Telnet port and UDP port The MAC address cannot be changed Click the Save Settings button to apply changes Click the Set Defaults button to restore the factory default IP settings The 32x32 Modular Matrix must b
41. et the 32x32 Modular Matrix to Reboot factory default settings Click this button to reboot the 32x32 Modular Matrix 94 APPENDIX Card Removal and Installation Although each 32x32 Modular Matrix is sold pre configured both input and output cards can be removed or added to fit the needs of the application Each module can easily be removed and installed without using any special tools q IMPORTANT Modules are sensitive to Electrostatic Discharge ESD which can damage the module Avoid touching the module contacts or the components on the module Always hold modules by the edges or by the knobs on the front of the module Never slide a module over any surface When installing replacing modules do not install an input module in to an output slot or vice versa This will damage the matrix and void the warranty 1 Power off the matrix 2 Tum the matrix around so that you are facing the back of the unit py STOP Before installing modules and prevent the risk of possible wy electrical shock unplug the AC power cord from back of the matrix 3 Loosen the fastening screws on both sides of the card or cover plate to be removed Each card cover plate has two fastening screws Fo aa cs 95 APPENDIX oF 6 Grab the knobs on both sides of the card between the thumb and index finger and gently pull to remove the card from the matrix as shown on the next page If a cover plate is bei
42. he DVI signal up to 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable OM3 and OM1 fiber are also supported 32 fiber optic Receiver units are included with this package option Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DVI Input Cards 4 Modular Matrix 8 DVI Sender over 1FO Cards 32 DVI Modular Receivers over 1FO 1 Quick Start guide INTRODUCTION GEF MOD 32432 FM10001FO Four input cards Each card contains eight DVI inputs which provides a total of 32 DVI inputs In addition this package option includes 32 DVI FM 1000 Plus Extender Sender Receiver pairs which allows you to connect DVI source devices from up to 1 kilometer away from the matrix Four output cards Each card contains eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend the DVI signal up to 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable OM3 and OM1 fiber are also supported 32 fiber optic Receiver units are included with this package option Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DVI Input Cards 4 Modular Matrix 8 DVI Sender over 1FO Cards 32 DVI Modular Receivers over 1FO 32 DVI FM 1000 Plus Extenders Sender Receiver 1 Quick Start guide GEF MOD 32432 DPDVI Four input cards Each card con
43. inal screen please wait 0x00 OxFF OxFF OXFF OxFF OxFF OxFF 0x00 0x10 OxAC 0x35 0x40 0x4C 0x32 0x33 0x32 0x31 0x13 0x01 0x03 0x80 0x41 0x29 0x78 OxEA O0x8F 0x95 0xAD 0x4F 0x32 0xB2 0x25 Ox0F 0x50 0x54 0xA5 0x4B 0x00 0x81 0x80 OxA9 0x40 0xD1 0x00 0xD1 0x40 0x71 0x4F 0x81 0x00 0xB3 0x00 0x01 0x01 DABO 0x68 0x00 OxAO OxAO 0x40 0x2E 0x60 0x30 0x20 0x36 0x00 0x81 0x90 0x21 0x00 0x00 Ox1E 0x00 0x00 0x00 OxFF 0x00 0x47 0x35 0x30 0x31 0x48 0x39 0x43 0x32 0x32 0x33 0x32 0x4C 0x0A 0x28 0x3C 0x80 0xA0 0x70 OxBO 0x23 0x40 0x30 0x20 0x36 0x00 0x81 0x91 0x21 0x00 0x00 Ox1C 0x00 0x00 0x00 OxFD 0x00 0x31 0x56 0x1D 0x71 0x1C 0x00 0x0A 0x20 0x20 0x20 0x20 0x20 0x20 0x00 0x41 45 predidst Command The predidst command displays the EDID used by each input Syntax predidst Parameters None Example predidst EDID table Input Source 1 Default 2 Default 3 Bank 2 4 Bank 2 5 Bank 2 6 25 7 25 8 Bank 2 9 Bank 2 10 Bank 2 11 Default 12 Default 13 Default 14 Default 15 Default 16 Default 17 Default 18 Default 19 Default 20 Default 21 Default 22 Default 23 Default 24 Default 25 Default 26 Default 27 Default 28 Default 29 Default 30 Default 31 Default 32 Default ID GEN GEN MEI MEI MEI DEL DEL MEI MEI MEI GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN GEN RS 232 IP UDP CONTROL APT APT
44. l Provides a discharge path to ground in case a short circuit occurs between the hot lead of the power supply and the enclosure of the Matrix The grounding wire should be attached from the grounding terminal to an approved ground path Matrix that was purchased the back panel may differ ig NOTE Depending upon the package option of the 32x32 Modular 11 CONNECTING THE 32X32 MODULAR MATRIX Connections Because there are several variations of the 32x32 Modular Matrix we will cover each package option Locate the connection instructions for the package which was purchased The wiring diagram at the bottom of the page provides a general reference for connecting the 32x32 Modular Matrix See the following pages for detailed connection instructions on each package option GEF MOD 392492 DV i sas oona EAEan 13 SERRO SO ADVIE L sai inae Aani aE E ANa 13 GEF MOD 32492 DVITFO sis saia iaeiiai 14 GEP MOD 32432 DV IFW QO0UFO i sccoresecess aesesasteeataatsescinnsesttpnatioweieaiere 16 GEF MOD 392492 DP DV suaas gar sinais E E 19 GEF MOD 3249 A DPELR oriin eia AS DT Ra cus ada 19 GEF MOD 92492 DP IFO raii Aia 19 Wiring Diagram Gefen z 2 e DVI CABLE ME CAT 5 CABLE ME FIBER OPTIC SC SC CABLE DVI Sources 32x32 Modular Matrix GEF DVI ELRPOL R Receivers at o e Up to 32x DVI Displays GEF DVI 1FO R Receivers GEF MOD 32432 WARNING This product should always be conn
45. mmand sets the TCP terminal server listening port The default port setting is 23 Syntax set tcp term port parami Parameters param Port 1 65535 Notes A reboot is required after using this command Example set tcp term port 21 New TCP Terminal port set to 21 51 RS 232 IP UDP CONTROL set_udp_port Command The set udp port command sets the UDP server listening port The default port setting is 21 syntax set udp port parami Parameters param1 Port ao 1 65535 Notes A reboot is required after using this command Example set udp port 56 New UDP server port set to 56 set_udp_rip Command The set_ udp rip command sets the remote UDP listening IP address The IP address must be specified using dot decimal notation The default UDP remote IP address is LOZs DOS 1 255 Syntax set udp rip paraml Parameters param 1 IP Address Notes A reboot is required after using this command Example tset udp rip 192 168 1255 New Remote UDP IP set to 192 168 1 255 52 RS 232 IP UDP CONTROL set_udp_rport Command The tset udp rport command sets the remote UDP listening port The default UDP remote port is 50008 Syntax set udp rport paraml Parameters param Port 1 65535 Notes A reboot is required after using this command Example set udp rport 30 New UDP Remote port set to 30 sgateway Command The sgateway comm
46. new FW 1 cancel O 5 Press the 1 on the computer keyboard to select Download new FW The following will be displayed Please send new FW bin file Waiting for the file to be sent press a to abort 6 In HyperTerminal click Transfer gt Send File 7 Select the firmware file MMTX BP e version bin 8 Select YModem from the Protocol drop down list 9 Click the OK button 98 APPENDIX The firmware update procedure will begin This process should take a couple of minutes and will update the back panel boards After the firmware update is successful the following will be displayed in the terminal program Verify Check sum please wait Download Completed Successfully MMTX BP e 0 3 43 bin Size 50688 Bytes Activate boot loader for BP board Please MALD mama ad cid ad The system will reboot itself please wait KKKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UL FW version 0 3 38 KKKKKKKKKKKKKKKKKKKKKKK Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Board 3 Board Type DVI input 8 channels Board SN 954849 FW ver 0 3 8 Establish connection with Input Board 4 Board Type DVI input 8 channels Board SN 954759 FW ver 0 3 8 Establish connection with Output Board 1 Board Type FO output 8
47. nformation on all available configurations it is important to identify the type of 32x32 Modular Matrix that you have purchased GEF MOD 32432 DVI Four input cards Each card contains eight DVI inputs providing a total of 32 DVI inputs Four output cards Each card contains eight DVI outputs providing a total of 32 DVI outputs Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 cable 2 AC power cords 4 Modular Matrix 8 DVI Input Cards 4 Modular Matrix 8 DVI Output Cards 1 Quick Start guide INTRODUCTION GEF MOD 32432 DVIELR Four input cards Each card contains eight DVI inputs providing a total of 32 DVI inputs Four output cards Each card contains eight ELR POL outputs Each of these ELR POL outputs are connected to a Receiver unit using a CAT 5e cable allowing you to extend the DVI signal up to 330 feet 100 meters 32 ELR POL Receiver units are included with this package option Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DVI Input Cards 4 Modular Matrix 8 DVI Sender over CAT 5 Cards 32 DVI ELR Receivers with POL 1 Quick Start guide GEF MOD 32432 DVI1FO Four input cards Each card contains eight DVI inputs providing a total of 32 DVI inputs Four output cards Each card contains eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend t
48. ng removed then loosen the fastening screws on both sides of the cover plate and gently remove the cover plate Locate the grooved metal track on either side of the expansion bay Upper rail Lower rail Carefully position the card between the upper and lower rail on each track and slowly push the card forward 96 APPENDIX 7 Position either hand on both sides of the matrix and firmly push the card with both thumbs until it snaps in place 8 Secure the card by hand tightening the fastening screws Do not overtighten the screws To prevent damage to the screws do not use pliers or other high torque devices Fastening screw A B 97 APPENDIX Firmware Update Procedure The following items are required to update firmware e GefenPRO 32x32 Modular Matrix Computer running Windows XP Terminal emulation program e g HyperTerminal e RS 232 cable do not use a null modem cable Firmware files MMTX BP version bin MMTX DVIinout version bin MMTX UI version bin To begin the update procedure use the 4fw update command The following set of instructions will be using Hyperterminal 1 Power on the matrix 2 Connect an RS 232 cable to the PC and open the terminal program using the following settings Baud rate 19200 Stop bits 1 Data bits 8 Flow control None 3 Type the command fw update 4 The following will be displayed on the terminal screen Download
49. nput 4 Input 5 Input 6 Input 7 Input 6 input 9 Input 10 w i E a E a E a E a Input 17 Input 18 Input 19 Input 20 Input 21 Input 22 Eta Jogos a e RS 232 IP UDP CONTROL 32x32 Modular Matrix Check All Places a check mark in each box under the 5V column Clear All Clears all check marks from the 5V column Set Click this button to enable 5V on the selected input s See the previous page for information on selecting inputs Cancel Restores the previous 5V state for each input if a change was made 5V ON legend If 5V has been enabled on any of the inputs these inputs will be highlighted in green See the previous page for more information 82 RS 232 IP UDP CONTROL Routing gt gt Output Masks Refresh Updates the Web page to reflect the new Input and or Output Name Routirk Status Manage EDID Configuration Se Do on amp io NES 3 LE oo Output Indicates the number of each output If the output has been masked it will be highlighted in blue as shown Name The current name of each output Mask Click to select the desired Output s to be masked Selecting an output does not automatically enable masking The Set button must be used to enable masking To disable masking deselect the desired outputs and press the Set button 83 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Out
50. ommand The set input name command provides the specified input with a name Syntax set input name paraml param2 Parameters param1 Input 1 32 param2 Name 20 chars max Example set input name 17 signal generator signal generator is assigned to input 17 60 RS 232 IP UDP CONTROL set_output_name Command The set output name command provides the specified output with a name Syntax set output name paraml param2 Parameters param1 Output 1 sa 92 param2 Name 20 chars max Example set output name 25 Dell 30 Dell 30 is assigned to output 25 set_preset_name Command The set preset name command provides a name for the specified preset Syntax set preset name parami param2 Parameters param1 Preset 1 16 param2 Name 20 chars max Example set preset name 2 Studiol Studiol is assigned to preset 2 61 RS 232 IP UDP CONTROL show input name Command The show input name command displays the name of the specified input Syntax show input name parami Parameters param1 Input 1 92 Notes If param1 0 then the name of all 32 inputs will be returned Example show input name 17 Input 17 signal generator show_output_name Command The show output name command displays the name of the specified input Syntax show output name parami Parameters param1 Input 1 es 92 Notes If param 0 then the name of all 32
51. or the matrix using the set_ udp rport command see page 53 for details 38 RS 232 IP UDP CONTROL RS 232 Telnet Commands tshow bank name Displays the name of the specified EDID bank edidbatolo Command The edidbatolo command loads the EDID from the specified EDID bank and writes it to the specified input s Syntax edidbatolo paraml param2 param3 param9 Parameters param1 EDID bank offset 1 20 param2 param9 Input list 0 32 Notes If param2 0 then the EDID in the specified bank is copied to all 32 inputs Example tedidbatolo 2 3 6 7 Loading EDID bank 2 to locals Inputs 3 6 7 please wait Finished Loading 39 RS 232 IP UDP CONTROL ediddetolo Command The ediddetolo command stores the default Internal EDID to the specified input s Syntax ediddetolo paraml param2 param3 param9 Parameters param param32 Input list 1 ce 92 Notes If param1 0 then the default EDID will be stored in all 32 inputs Examples ediddetolo 5 6 7 Loading default EDID to locals Inputs 5 6 7 please wait Finished Loading ediddetolo 0 Loading default EDID to all locals Inputs please wait Finished Loading 40 RS 232 IP UDP CONTROL ediddstoba Command The ediddstoba command reads the downstream EDID and stores it to the specified EDID bank Syntax ediddstoba paraml param2 Parameters param1 A downstream
52. outputs will be returned Example show output name 25 Output 25 Dell 30 62 RS 232 IP UDP CONTROL show_preset_name Command The show preset name command displays the name of the specified preset Syntax show preset name parami Parameters param1 Preset 1 16 Example show preset name 2 Preset 2 Studiol unmaskout Command The unmaskout command unmasks the specified outputs Syntax unmaskout paraml param2 param Parameters param1 Output 1 32 Notes If param7 0 then all outputs will be unmasked Example funmaskout 4 5 8 Unmasked Outputs 4 5 8 unmaskout O Unmasked all Outputs 63 RS 232 IP UDP CONTROL m Command The m command displays the current matrix status in tabular form Do not precede this command with the symbol Syntax m Parameters None Example m Show the matrix status in Routing status table tabular form Outputs 0 1 2 3 4 5 6 F7 1 22 2 3 4 5 6 7 8 9 9 10 11 12 13 14 15 16 L7 L7 18 L9 25 17 22 23 24 25 17 26 27 28 29 30 31 32 Masking status table Outputs 0 l 2 3 4 5 6 7 1 A A A A A A A A 9 A A A A A A A A t7 A A A A A A A A 25 A A A A A A A A Monitor HPD status table Outputs 0 1 2 3 4 5 6 7 1 L L L L L L L L 9 L L L L L L L L t7 L L L L L L L L 25 H L L L L L L L 64 RS 232 IP UDP CONTROL r Command The r
53. put 7 Output amp Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 Output 25 Output 26 Output 27 JooDooooooogoDooogonossoaaaoos y RS 232 IP UDP CONTROL 32x32 Modular Matrix Output Masks Check All Places a check mark in each box under the Mask column Clear All Clears all check marks from the Mask column Set Click this button to enable masking on the selected output s See the previous page for information on selecting inputs Cancel Restores the previous masking state for each output if a change was made Masked legend If masking has been enabled on any of the outputs then these outputs will be highlighted in blue 84 RS 232 IP UDP CONTROL Status gt gt In Out The Status gt gt In Out tab provides information on the hardware and firmware of the 32x32 Modular Matrix The OUTPUTS column lists each Output Card that is installed The INPUTS column lists each Input Card that is installed The information presented on this screen is used by Gefen Technical Support for troubleshooting purposes only 32x32 Modular Matrix S N Type FAW Ver Tempi Temp Connection Power 3 3v Power 5 0v Power 1 8v S N Type FAN Ver Tempi Temp Connection Power 3 3v Power 5 0v Power 1 8v 9871708 0 03 08 49 C deg 41C
54. ra CE ANPR ANDREA PA A PP NASE AAAEEERAANSE ERRA 37 RoZa SeS a EE 37 Configuring the IP AG GSS Sc5 ietoctacessacenccseigisgatasertnimslnnslantit ooahstedned anebemtcosbantadedareonmenecons 38 RS 232 Telnet COMMMANGS ics ictessenctanezencexacnatineatancsend aeeaxedbonatnasmornondendshanineatnarnendeneuniens 39 EDID Mapage meN eresien ass cu tn assinei dan nara sanar animadas dia nan ia 39 ZG oj a ile TE i e A A E anne Aerie aie te a eee Sen Ne 49 PO CIE and Masking caranesstvetecosiranctedsnmansaaentteans ano sad evade Ra sae taraaaets 57 BOS NG O E E P E E E TA TA E EE E T 67 Using the Built in Web Server aiii aro iria ta ii ais ad 75 PO UNG EEPE P E AT E A AT A 75 BSa MNI a a AREE E PEE E E E EEEE E EEES T 75 aee E E E E E E E A E E 79 WO NING EENE A E E EET 80 DO AE EE EETA EEE EE AT EE PEE E ETE E E T TANT 81 Droe AS E RD RO E E E A E T 83 CONTENTS ho Ji Es a REI RE O heen iad E RO E A NR IS E A NAT E 85 UN CR aoe acer ce ecevse ee S OCO cutee dE dani Sh rir Rolo A GEC EE 85 SL q etc a RCE GR RG ores eon aed tena RR RR 86 Manage E DID acd rias ind a denaadaceuaniineiines 87 POSSI EET IE IEEE EA TETE A T TAAA IOA AT T 87 Bank NaMe Sesinin E AAEE 89 Upload D wnload seiisiisiceriicrrsii erinnern iaaa earner aasaran 90 Ee DE E AE A AE E T A E A ANA E A A E 91 PE Nyaa ccs ap erect A S a E DES adsl 95 Card Removal and Installation ccccccccccsssseecceeseeceseeseeecseseeeeseuseeecsuseeeeseuseeessaees
55. rd 2 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with Input Board 3 Board Type DVI input 8 channels Board SN 954849 FW ver 0 3 8 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading Downstream EDID 25 to all locals Inputs please Finished Loading 71 RS 232 IP UDP CONTROL show temp Command The show_ temp command displays the temperature of each board within the matrix Syntax show temp Parameters None Example tshow temp Temperature result C deg for UI board 34 Temperature result C deg for BP board sensorl Mindspeed 47 sensor2 power 39 Temperature result C deg for Inputs board Board 1 2 1 42 34 2139 33 3138 oo 4137 35 Temperature result C deg for Outputs board Board 1 2 1 51 43 2153 SS 3 52 38 4147 39 show_ver_data Command The Show ver data command displays the current hardware and firmware version Syntax show ver data Parameters None Example show ver data Firmware Release version 0 3 38 Release date Nov 20 2012 Release time 15 00 38 72 RS 232 IP UDP CONTROL show_voltage Command The show_ voltage command displays the input and output board voltages Syntax show voltage Parameters None Example show voltage ADC UI measurment result VCC CORE 1 8 Value 1845 mVolt PSUL
56. ress the Cancel button while in any mode to return to cancel the current function and display the Standby Mode screen DONRRREA ae The 32x32 Modular Matrix front panel LCD screen as it appears in Standby mode 25 OPERATING THE 32X32 MODULAR MATRIX Cycling between Information Screens Press the Cancel button more than once while in Standby Mode to cycle through each of the information screens q OPERATING THE 32X32 MODULAR MATRIX Saving the current Routing State Set the routing state see page 22 then press the PreSet button twice to activate Preset Mode After pressing the PreSet button once the following will be displayed on the front panel LCD screen Press the PreSet button again The following will be displayed on the front panel LCD screen 27 OPERATING THE 32X32 MODULAR MATRIX 2 Press an Input button A1 D8 to store the current routing state 3 Press the Set button to complete the operation The system will remain in Save Current Preset Mode The front panel LCD screen will indicate that the current routing state has been saved 28 OPERATING THE 32X32 MODULAR MATRIX Recalling a stored Routing State 1 Press the PreSet button once to activate Recall Preset Mode g a The following will be displayed on the front panel LCD screen 2 Press the Input button A1 D8 of the routing state to be recalled 29 OPERATING THE 32X32 MODULAR
57. servicing and zero down time are required How It Works Connect up to 32 DVI source devices using DVI cables to the inputs on the GefenPRO Modular Matrix Connect up to 32 displays via DVI CAT 5 or Fiber Optic cables depending on which output modules are utilized Connect an Ethernet cable from the network to the RJ 45 connector to use the built in Web server or Telnet capability to control routing EDID and other functions Connect an RS 232 cable from a RS 232 control device to control the matrix via RS 232 Connect the IEC connectors of the included AC power cords to the matrix and plug the power cords into available electrical outlets The DVI sources will be routed as selected INTRODUCTION Features Supports resolutions up to 1920 x 1200 e Modular inputs and outputs organized into banks of 8 input or output devices e Advanced EDID management for rapid integration of sources and displays e RS 232 Serial interface for remote control via a computer or automation control system e Front panel LCD display Front panel push buttons for local switching e Built in Web server Telnet and UDP control via IP e Routing states can be stored and recalled at the touch of a button Dual redundant hot swappable power supplies Removable and replaceable fan and filter e Output masking command Standby mode e Power ON OFF switch Rack mountable Package Includes See the information beginning on the next page for det
58. t special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com PRODUCT REGISTRATION Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site 104 LICENSING IwIP is licenced under the BSD licence Copyright c 2001 2004 Swedish Institute of Computer Science All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO
59. t udp port show user name show tcp term pass set tcp term pass fadefault factory reset fw upgrade 69 RS 232 IP UDP CONTROL hpdto Command The hpdto command cycles the HPD line on the specified input This command is the equivalent of performing a physical hot plug disconnecting and reconnecting on the source device Syntax hpdto paraml Parameters param1 Input 1 32 Example hpdto 17 HPD cycle on input 17 lock_fo Command The lock_ fo enables disables the power lock state Enabling this feature will store the 5V status for each input prior to powering down the matrix The 5V state is preserved when the matrix is powered syntax lock fo paraml Parameters param1 State O 1 o Disable O Example lock fo 1 5V on inputs is locked 70 RS 232 IP UDP CONTROL reboot Command The reboot command reboots the matrix This is the equivalent of physically disconnecting and reconnecting the AC power cord to the matrix param must be included as part of the command at all times Syntax xreboot parami Parameters param 1 Constant 10 Example reboot 10 The system will reboot itself please wait KEKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UI FW version 0 3 38 KKKKKKKKKKKKKKKKKKKKKKK Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Boa
60. tains eight DisplayPort inputs providing a total of 32 DisplayPort inputs Four output cards Each card contains eight DVI outputs providing a total of 32 DVI outputs Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DisplayPort Cards 4 Modular Matrix 8 DVI Output Cards 1 Quick Start guide INTRODUCTION GEF MOD 32432 DPELR Four input cards Each card contains eight DisplayPort inputs providing a total of 32 DisplayPort inputs Four output cards Each card contains eight ELR POL outputs Each of these ELR POL outputs are connected to a Receiver unit using a CAT 5e cable allowing you to extend the DisplayPort signal up to 330 feet 100 meters 32 ELR POL Receiver units are included with this package option Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DisplayPort Cards 4 Modular Matrix 8 DVI Sender over CAT 5 Cards 32 DVI ELR Receivers with POL 1 Quick Start guide GEF MOD 32432 DP1FO Four input cards Each card contains eight DisplayPort inputs providing a total of 32 DisplayPort inputs Four output cards Each card contains eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend the DisplayPort signal up to 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable OM3 and OM1 fiber are also suppor
61. tec tense RENE EDELE ECAA 11 CONNECTING THE 32x32 MODULAR MATRIAX ccccccessseeeeeeeeeeaeeneesseeaasseneesanaaeeneeees 12 Oro 0 gls 0 6 eee eee ne eeeete PPS ERR Raro here nee eter ree een eee een nee ee een nee 12 A la io DIAG jo i ProDeR E E PEER RN REDE RR NR ODE RR E RR VI PR 12 DisplayPort package ODO cccccccescectecceeccxacccnctceeeresacdnncceanesaesecpsausbsesiaceteetoeseaididedsacctad 19 OPERATING THE 32x32 MODULAR MATRIA ccccceeesseeeeeeeeeeeseeeeesseeaaeneeesseeaaaeeneess 20 Booting Up Standby Screen asi csncacecestusnsivaventseesuinsanntindsiadienhisiedilsiedend e Send ENEEK EAEN 20 Displaying the current Routing StAle ccccccccsccscasessdcecorcracvancctecndsedsdenscbeosetaasiteeendsecescneses 21 Routing SOU CS isna A a 22 Eee genia a PE E A NE E E E A A E E T asenaten 24 Usmo the Can Ce WOU MON PORCA Ra q RR ra RO RR E 25 Cycling between Information SCreens cccccsssssseeecccecseeeeeeeceeeseeeeeeseauaaeeeeessaeaseeeess 26 Saving the current Routing Ste gastas Etta e waesendesueseudedacasesores 27 Recalling a stored Routing State ccesccccssessseaciesdeiacccratdnessacectangevececidersonetesseeseacsacesaeeie 29 Masking O pio 0 RARA ERRA RR cu N RR RR RPE N e RR 31 ED AAS a a 33 Saving the Downstream EDID to Local memory es 33 Saving the Default EDID to Local memory errar So Roa VIPOONTRO aa casa ace tere canner rc Onda A cada d a idas ada nad 37 RS 232 Inte
62. ted 32 fiber optic Receiver units are included with this package option Package Includes 1 32x32 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 4 Modular Matrix 8 DisplayPort Input Cards 4 Modular Matrix 8 DisplayPort Sender over 1FO Cards 32 DVI Modular Receivers over 1FO 1 Quick Start guide If any of the items from these pre configured packages are missing call Gefen Technical Support between the hours of 8 00 AM and 5 00 PM Monday through Friday Pacific Time INTRODUCTION Front Panel Layout IAL SENTO ZEXTE Hada EOE a ara g A g INTRODUCTION Front Panel Descriptions Mode Buttons These buttons are used to control other features on the product See pages 22 36 for more information Output Buttons 1 32 Used for routing an Input to an Output Each of these buttons represents an Output See page 22 for more information on routing DVI sources Power Indicator This LED indicator will glow red when the power is turned on LCD Display Displays the current routing status of the Matrix and is also used to manage source routing Input Buttons 1 32 Used for routing an Input to an Output Each of these buttons represents an Input See page 22 for more information on routing DVI sources INTRODUCTION Back Panel Layout ALLL DES sS55EERH TT WEBBESGSS so DRA See ip DE A EBREV Gp OL eel TA ME ui aa Se NENmnnaa E 10 INTRODUCTION Back Pan
63. ts Syntax maskout paraml param2 param Parameters param param8 Output ieee Notes If param 0 then all 32 outputs will be masked Examples maskout 2 3 4 Masked Outputs 2 3 4 maskout 0 Masked all Outputs 58 32 prpreset Command RS 232 IP UDP CONTROL The prpreset command displays the current list of presets in tabular form Syntax prpreset Parameters None Example prpreset Preset table Set Outputs 1 M2A2 A17 A18 2 A22 A2 A17 A18 3 1IA0OAO AQAO 4 AOA O AQAA O 5 AOA O AQAO 6 ADA O AQAO 7 AOA O AQAO 8 AQAO AQAO 30 ADA O AQAA O 31 ADA O AQAO 32 ADA O AQAO D gt gt gt PP P P P PP Pe D p gt DD Pp PH O O O O O O O Oo O5 oo O O D gt gt gt FP PDP P gt D gt gt PP PP P P P PSP PS Pe M 5 A21 A 6 A22 A 7 A23 A 8 A24 A 9 A25 M10 A26 M11 A27 A13 A29 O D Oo O O O O O O O O O O PP gt gt PP PP P P P PSP PS Pe O O gt D gt gt FP PDP P A 5 A17 O D gt gt P gt PP P P PP P P PP P O 0 O o O O O O O O o o gt D gt D gt FP PDP P A 6 A22 O D O O O O Oo LC Oo O D gt gt gt PP P P P PP PP Pe O O O O gt D gt gt P PDP P A 7 A23 S O oc O O O gt gt gt gt P P P P P P MN O O O O O A
Download Pdf Manuals